Lynx ADP-215, ADP-12S, ADP-18S, ADP-26, ADP-15 User Manual

...
USER MANUAL
V.12.12
ADP-215
Lynx Pro Audio S.L.
Valencia, Spain - www.lynxproaudio.com - info@lynxproaudio.com
ADP-215
Class D Powered (bi-amplified)
Integrated Digital Processing
Internal temperature control
Electronic protection
High quality components
Online monitoring available
Manufacturer
CB SCHEME, IEC SYSTEM FOR CONFORMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT
CE CERTIFICACTION, EUROPEAN PRODUCT
ADP-215 powered cabinet
LYNX Pro Audio S.L. Calle 7 - Pol. Ind. Picassent E-46220 Picassent (Valencia)
This user manual is property of Lynx Pro Audio S.L. Any reproduction of this manual, by any means is strictly prohibited. Copyright 2012. All rights reserved.
ADP-215
CONTENTS
- SAFETY PRECAUTIONS 5
- CABINET INTRO
SPECIFICATIONS 6 BACK PANEL 7 CONNECTORS AND CONNECTIONS 7
- CONFIGURING THE CABINET DSP OPTIONS
PRESET LIST 9 FIR FILTERS 9 CONFIGURATION PANEL 10 SELECT AND RUN PRESET 10
- ONLINE CONTROL SYSTEM 11
- CONFIGURING ETHERNET 12
- SOFTWARE, RAINBOW
ACOUSTICAL PREDICTION SOFTWARE 18 FEATURES 19
- ACCESSORIES 20
- GUARANTEE 21
ADP-215
Before starting to use this device, please read this instruction manual carefully. Keep these instructions in the place where the equipment will be used and with easy access to them.
- Electrical appliance.
The exclamation mark within a triangle identifies the presence of electricity. Use the system carefully without wet hands or feet. Avoid installing the speaker in wet or excesivelly humid places. Do not place material that contains liquid on or near the unit. Avoid dripping or splashing water or any liquid over the unit. Regularly check the condition of the cables and make sure these are not being walked on or pinched. Connect the speaker to bipolar, earthed mains. The mains plug must be connected to the appropriate protection (fuse or breaker). Connection to any other type of mains could result in an electrical shock and violate local electrical codes. CAUTION: DO NOT CONNECT OR DISCONNECT THE AC POWER CONNECTORS UNDER LOAD.
- Heavy equipment.
Apply back protection when using the system. Avoid loading and unloading at heights.
- Electrical shock risk.
The diagonal mark within a triangle identifies the presence of dangerous voltage. Do not open or handle the interior of the box. These parts are not to be adjusted by the user. For maintenance and/or repair please go to an authorized service centre. In order to reduce the risk of electric shock, disconnect from AC before plug in or unplugging Audio signal cables. Reconnect to AC only if all signal connections are made and secured. Never manipulate the ground type plug provided. The AC mains plugs should always remain accessible for operation. Unplug the loudspeaker during storms or when it’s being used for a long time.
- Hearing damage risk.
These systems can reproduce large quantities of sound pressure which can damage hearing. Take precautions if you are going to be near them for extended amounts of time and do not get too close.
- Hanging – Flying.
Do not hang the cabinets from the handles or from any other part other than the designated hanging point. When flying this system please observe the technical and “Lynx On Stage” software data carefully. Never exceed the maximum safe working loads or ignore the instructions included within this manual. Use Only flying accessories provided by Lynx Pro Audio S.L. Rigging must be always carried out by professionals.
- Delicate Material.
Please ensure no foreign object or water enters the speaker. Only clean the unit with dry cloths. Do not use solvents.
-Overheating – Fire risk.
To reduce the risk of the speaker over heating, avoid direct contact with sunlight. Avoid placing the unit close to heat inducing objects such as radiators. Do not cover the equipment in use and do not block any ventilation openings. Do not put naked flame, such as lighted candles, close or on top of the unit.
- Electromagnetic and interferente emissions.
Avoid placing objects which through electromagnetic waves can damage the unit, such as mobile phones, lap tops, magnetic strip cards etc. This system complies with normatives EN 55103-1 (1)
EN 55103-2 (2) (1) This device may not cause harmful interferences. (2) This device may receive interference including interferences that may cause undesired working.
-IMPORTANT NOTE.
This Equipment must be used in accordance with these instructions and by trained professional personnel only. This equipment should not be used in places with extreme tropical climates. Don’t expose this apparatus to extreme humidity and or temperature values.
5
ADP-215
INTRODUCTION
To facilitate, correct and reliable use of the powered cabinet ADP-215 we have designed this instruction manual. Please read the manual carefully before proceeding to install the system.
Please observe the technical data carefully and do not ignore the instructions included within this manual.
6
* Ethernet connection is optional.
SPECIFICATIONS:
FREQUENCY RANGE 40Hz -20KHz FREQUENCY RESPONSE 45Hz- 18KHz ± 3dB COVERAGE 60º x 50º rotable Horn MAX SPL 140 dB/ 143dB peak 1w@ 1m CROSSOVER 1200 Hz
TRANSDUCERS LF/MF: 2 x 15" Custom Neod. + Nomex Cone
100 mm Voice Coil HF: 1.4" Neod. driver with 72,2 mm Titanium
diaphragm + constant directivity Horn SHAPE Trapezoidal POWER AMPLIFIER 2000W Class D with Switching Power supply
2 channels / 3 power modules
2 x 750W Low/Mid + 500W High DSP Internal Lynx processor DSPB-22® with FIR filters CABINET ADJUSTMENT Back panel LCD screen INTERNAL CONTROLS Temperature sensor / Fan Speed control SIGNAL CONNECTION NEUTRIK connectors XLR Male Input
XLR Female Loop Thru CONTROL CONNECTIONS USB (DSP programming),
ETHERNET* (Online Monitoring System OMS®) AC POWER 230v / 115v selectable. 50/60 Hz 5A AC CONNECTIONS 16A NEUTRIK POWERCON with Looping Output CONSTRUCTION 15 mm Premium Birch plywood FINISH High resistant water-based black paint FRONT DESIGN Black antirust steel grille
DIMENSIONS (H x W x D) 1107 x 489 x 415 mm WEIGHT 52 Kg (114 lbs)
ADP-215
7
CONNECTORS AND CONNECTIONS
1.- SIGNAL INPUT.
2.- SIGNAL LINK.
3.- AC INPUT.
4.- AC LINK (máx. +2 cabinets).
5.- USB.
6.- DSP CONTROL.
7.-ETHERNET (optional)
ADP-215 BACK PANEL.-
XLR AEREAL CONNECTORS
Connect to output
Connect to input
2 Live(+)
3 Live(-)
1 Earth
3 Live(-)
1 Earth 2 Live(+)
1
2
3
4
5
6
7
Loading...