MANUAL LYM 1.0 T
TECHNOLOGY AND COMPONENTS
Ÿ
Ÿ SMT constructional technique:
Ÿ High quality printed circuit, both in terms of materials used and of circuit design, full of
devices that aim to minimize noise and loss of power and to avoid internal wiring
Ÿ TRIPATH TA2024C chip
Ÿ Two-stage output filters designed to reduce noise to meet 'Class D' criteria and
electromagnetic interference emissions
Ÿ Stabilized voltage regulator equipped with high performance capacitor which is necessary to
meet the energy requirements during peaks of acoustic power.
Ÿ High performance capacitor (10000μF) positioned at the power circuit output.
Ÿ Low noise polypropylene capacitor in the TA2024C chip input circuits
Ÿ Overload LED for excellent music listening. This indicator light comes on when the user pushes
the volume beyond the TA2024C chip's capacities, i.e. beyond the distortion threshold. The
listener can thus reduce the volume until the LED turns off and guarantee listening without
any noticeable distortion. If this LED stays on and the amplifier goes silent, it indicates an
accidental short circuit at the output terminals or that the TA2024C chip has overheated;
should this happen, just turn off, remove the cause and turn on again. If it turns out that the
chip has overheated, you need to turn off and wait until its temperature has dropped to below
105°C before turning it on again.
Ÿ Power supply. A 16/19Vdc, at least 50W switching power supply is recommended (supplied
optionally). This type of power supply can easily be bought (power supply for Notebook, jack
size 2.5x5.5 mm.). The amplifier's internal regulator aims to stabilize the voltage at 13.68V
and to eliminate the typical ripple of this type of power supply. Furthermore, the internal
regulator also avoids malfunctions provoked by (short term) increases in power supply
voltage. In any case, it is possible to use a classical linear power supply set between 16 and
19Vdc.
Ÿ Protective diode positioned at the power input to avoid internal malfunctions caused by
power supply polarity inversions.
Class D Amplification (commercial identification “Class-T” property of TRIPATH).
MANUAL LYM 1.0 T
PAGE 3PAGE 6
ELECTRICAL CHARACTERISTICS
External power supply: 16Vdc /19Vdc 2.2A (minimum), Power Jack 2.5x5.5mm ( + central).
Internal power supply: 13.68Vdc, Ripple + Noise: 100uV
Input impedance: 12KOhm
Input sensitivity: 1Vp @ Pmax (Audiophile Quality Sound). See workshop tests.
Passband: 10Hz- 20 KHz
Maximum load power: 2x17W @ 4 Ohm, 2x12.8W @ 6 Ohm, 2x10.4W @ 8 Ohm,
RMS values of power measured at frequency of 1KHz.
Protection: Short circuit (over-current), Heat (over-temperature).
Outputs: BTL configuration (Bridge Tied Load).
Inputs: AUX1 and AUX2, both with sensitivity of 1Vp.
Current: - Max Output Power (4 Ohm): 11.5 Watt/channel at 2.4 A, for
distortion-free listening.
- Zero Output Power (Volume at zero): 140 mA
- Stand-by Power (Amplifier off): 9 mA
Note: The values quoted above were measured with an external power voltage of 19 Vdc.
Dimensions: 192mm x 139mm x 61mm (case + dial + connectors)
Weight: 550g
CERTIFICATE OF GUARANTEE
Your Lym 1.0T is guaranteed for 3 years*!
The guarantee is valid from the date on the purchase receipt
The relevant serial number, which is also displayed inside the amplifier, is unique.
Your Lym 1.0T serial number
Regarding any malfunction, contact us directly at: info@lymaudio.it
“GUARANTEE” means the free repair or replacement of components or parts of the device that are recognized, by
Lysis-May S.r.l., to be faulty in manufacture or in materials employed
Sending and return of the device is at customer's expense
The guarantee does not cover damage due to negligence, incorrect usage or installation, not conforming to the
warnings in the instruction manual, lightning, overloading and overvoltage, insufficient or irregular power supply,
or damage that occurs during transport to or from the customer.
Lysis-May S.r.l. declines any responsibility for any damage that can, directly or indirectly, result to people, things
or animals as a consequence of improper use of the device.
Modifications to the device during the guarantee period annuls said guarantee.