LXNAV SmartSense / NMEA2000 Temperature, Air Pressure, Humidity Sensor Manual

Page 1
Page 1 of 13
SmartSENSE
Version 1.00
LXNAV d.o.o. • Kidričeva 24, 3000 Celje, Slovenia • tel +386 592 33 400 fax +386 599 33 522
marine@lxnav.com marine.lxnav.com
Page 2
Page 2 of 13
1 Important Notices 3
1.1 Limited Warranty 3
1.2 Packing Lists 4
2 Technical Data 5
2.1 General specifications 5
2.2 NMEA2000 specifications 5
2.3 Sensors 6
2.3.1 Temperature and humidity sensor specifications 6
2.3.2 Barometric sensor specifications 6
Product specification 7
2.3 NMEA2000 M12 connector pinout 7
3 Device Installation 8 4 Connecting to the SmartSENSE 9
4.1 Connect to the device via Wi-Fi 9
2.4 Home page 9
2.5 Parameters Error! Bookmark not defined.
4.3.4.1 About Error! Bookmark not defined.
4.1 Firmware update 11
5 Supported data 12 6 Revision history 13
Page 3
Page 3 of 13
1 Important Notices
Information in this document is subject to change without notice. LXNAV reserves the right to change or improve their products and to make changes in the content of this material without obligation to notify any person or organization of such changes or improvements.
A Yellow triangle is shown for parts of the manual which should be read very carefully and are important when operating the E500/E700/E900.
Notes with a red triangle describe procedures which are critical and may result in loss of data or any other critical situation.
A bulb icon is shown when a useful hint is provided to the reader.
1.1 Limited Warranty
The SmartSENSE product is warranted to be free from defects in materials or workmanship for two years from the date of purchase. Within this period, LXNAV will, at its sole option, repair or replace any components that fail in normal use. Such repairs or replacement will be made at no charge to the customer for parts and labour, provided that the customer pays for shipping costs. This warranty does not cover failures due to abuse, misuse, accident, or unauthorized alterations or repairs.
THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED OR STATUTORY, INCLUDING ANY LIABILITY ARISING UNDER ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, STATUTORY OR OTHERWISE. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, WHICH MAY VARY FROM STATE TO STATE.
IN NO EVENT SHALL LXNAV BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES, WHETHER RESULTING FROM THE USE, MISUSE, OR INABILITY TO USE THIS PRODUCT OR FROM DEFECTS IN THE PRODUCT. Some states do not allow the exclusion of incidental or consequential damages, so the above limitations may not apply to you. LXNAV retains the exclusive right to repair or replace the unit or software, or to offer a full refund of the purchase price, at its sole discretion. SUCH REMEDY SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY FOR ANY BREACH OF WARRANTY.
To obtain warranty service, contacts your local LXNAV dealer or contact LXNAV directly.
April 2022 © 2022 LXNAV. All rights reserved.
Page 4
Page 4 of 13
1.2 Packing Lists
SmartSENSE unit
Quick Reference Manual
Page 5
Page 5 of 13
2 Technical Data
2.1 General specifications
Parameter
Condition
Min
Typ
Max
Unit
Operating supply voltage
(1)
7
12
32
V
Absolute maximum supply voltage
(2)
Non-operating
-50 36
V
Current consumption
(1)
WIFI Enabled
100
mA
Load equivalent number
WIFI Enabled
1
LEN
Supply protection
-50V
V
Operating temperature
-20
+65
°C
Storage temperature
-40
+85
°C
Recommended humidity
0 95
RH
Weight 100
g
Housing length
95
mm
Housing diameter
24
mm
Ingress Protection
IP66
IP
Note1: Supplied via M12 NMEA2000 connector Note2: Non-operational, voltages outside of this range may permanently damage the device
2.2 NMEA2000 specifications
Parameter
description
Compatibility
NMEA2000 compatible
Bit rate
250kbps
Connection
A coded M12 connector
Note1: Supplied via M12 NMEA2000 connector
Page 6
Page 6 of 13
2.3 Sensors
2.3.1 Temperature and humidity sensor specifications
Parameter
Condition
Min
Max
Unit
Operating input range
0
100
%RH
Relative humidity accuracy
typ. ±2
%RH
Operating input range
-40
+125
°C
Temperature accuracy
Pullup enabled
typ. ±0.5
°C
2.3.2 Barometric sensor specifications
Parameter
Condition
Min
Max
Unit
Operating range
10
1200
hPa
Resolution 0.03
hPa
Accuracy (at 25°C, 750mbar)
±2
hPa
Temperature accuracy
±0.8
°C
Page 7
Page 7 of 13
3 Product specification
2.3 NMEA2000 M12 connector pinout
CAN_L
CAN_H
12V
Ground
NMEA2000 pinout
Male connector (pins)
12V
CAN_L
Ground
Shield
CAN_H
NMEA2000 pinout
Female connector (sockets)
2 1
4
3
5
1 2
3
4
5
Figure 1: NMEA2000 M12 Male connector pinout (view from unit side)
Rubber case
Housing for temperature,
pressure and humidity sensors
Cable 1.2m
M12 connector
NMEA2000
QR Code WiFi
Page 8
Page 8 of 13
4 Information and Installation
General:
The SmartSENSE is an All-in-One device which measures air temperature, barometric pressure, humidity and dew point. The SmartSENSE must be connected to the NMEA2000 network and will provide the measurements via smartphone or any compatible chartplotter.
The device requires no maintenance; calibration of the digital sensors has been performed by the manufacturer.
Connecting to the NMEA2000:
The SmartSENSE must be connected and powered up by the NMEA2000 network. Once performing, the device will start reporting the measurements and display them on any compatible chartplotter, smartphone, tablet or computer.
Mounting position:
When installing, choosing the right spot is important. To ensure accurate readings make sure to choose an area well-ventilated away from wet surfaces. Do not place the sensor in an area where it may be flooded. Do not place the sensor in direct sunlight during peak hours, as this could affect its data. Heating sources causes errors when measuring humidity and temperature. Avoid areas where the SmartSENSE sensors can be exposed to unintentional impact. To prevent the sensor from being heated by the vessel itself, minimize the area of contact between the sensor housing and other surfaces. To isolate the sensor housing from metal surfaces or surfaces that can be heated from within or other parts of the vessel use low thermal conductivity materials.
Page 9
Page 9 of 13
3 Connecting to the SmartSENSE
Configuration can be performed via QR code & Wi-Fi with any Smartphone or tablet. Measurements are readable by any compatible NMEA2000 chartplotter.
3.1 Connect to the device via Wi-Fi
The SmartSENSE has an integrated Wi-Fi hotspot which allows you to connect to it with any smartphone, tablet or computer. Joining the device network can be done via scanning the QR code or by entering the password from the label of the SmartSENSE unit.
Configuration via QR code scan :
Use the camera on your smartphone or tablet and scan the QR code. Join the SmartSENSE Wi-Fi network. Once connected, a new popup webpage will open automatically. If not, quit the camera app on your smartphone and open your browser, the configuration webpage will automatically be displayed.
Manual configuration:
Search the device in the list of available Wi-Fi networks and fill the password from label on SmartSENSE unit. Open a new page and access to the configuration page: http://config.smartsense.com/home
Once connected to the network, you will have access to the home page.
4.1 Home page
The home page displays current weather data and configured sensor data.
Outside air temperature
Pressure
Humidity
Dew point
The monitoring air temperature, humidity and barometric pressure are shown into individual screen to get precise information about current status and history based on the configured tracking intervals.
Page 10
Page 10 of 13
4.2 Settings
Tracking
Tracking interval configuration
5 minutes
15 minutes
30 minutes
1 hour
2 hours
4 hours
The battery will last according to the tracking intervals. Fast recharge is powered by the NMEA network.
Units
Temperature source configuration:
Celsius (°C)
Fahrenheit (°F)
Kelvin (K)
Pressure
Millibars (mbar)
Hectopascals (hPa)
Millimetres of mercury (mmHg)
Inches of mercury (inHg)
Time & date
Time format
24 hours
12 hours
Date format
DD.MM.YYYY
MM/DD/YYYY
YYYY/MM/DD
Home page
Top value / Primary and Secondary chart value
Outside air temperature
Pressure
Humidity
Dew point
Page 11
Page 11 of 13
5 Info page
5.1 General information
The info page shows the general information about SmartSENSE device:
Firmware version,
Firmware build time
Device time
5.2 Firmware update
Download the latest firmware from your smartphone directly from the LXNAV web site. Follow the below instruction to proceed to the firmware update.
1. Select the file.
2. Select the downloaded firmware file (normally it is downloaded into downloads folder)
3. Press UPLOAD
4. When upload is COMPLETED, press UPDATE
5. Wait a minute and device will be updated with new firmware.
Page 12
Page 12 of 13
6 Supported data
NMEA 2000 compliant PGN List NMEA 2000 PGN (Receive)
BAROMETER PGNS RX 129029 - GNSS Position Data
BAROMETER PGNS TX
130310 - Environmental Parameters 1 130311 - Environmental Parameters 2 130314 - Actual Pressure
HUMIDITY PGNS RX 129029 - GNSS Position Data
HUMIDITY PGNS TX 130310 - Environmental Parameters 1 130311 - Environmental Parameters 2 130312 - Temperature 130316 - Temperature, Extended Range 130313 - Humidity
Page 13
Page 13 of 13
7 Revision history
Date
Revision
Description
May 2023
1
Initial release of this manual
Loading...