luxvision LCP-7800 User Manual

1
IMPORTANT NOTICE
This product may malfunction due to electromagnetic waves caused by portable
personal telephones, transceivers, radio-controlled toys, etc. Be sure to avoid having
objects such as, which affect this product, brought near the product.
2
1. Introduction
1.1. Outline of product ....................................................................................................4
1.2. Classifications ...........................................................................................................4
1.3. Standards .................................................................................................................4
1.4. EMC Information ......................................................................................................5
2. Safety Information ..........................................................................................................8
2.1 Introduction .............................................................................................................8
2.2 Safety Symbols .........................................................................................................9
2.3 Environmental factors ............................................................................................. 12
2.4 Safety Precautions .................................................................................................. 14
3. Features
4. Notes for Using the Instrument .................................................................................... 17
5. Configurations ........................................................................................................... 18
5.1 Main Body .............................................................................................................. 18
5.2 Main Body cont. ..................................................................................................... 19
5.3 Accessories ............................................................................................................. 20
6. Installation
6.1 Position of Chart Projector ...................................................................................... 21
6.2 How to obtain correct Letter Size and focus ............................................................ 22
(Zooming Type only) .................................................................................................... 22
7. Input and Use of Program ............................................................................................ 22
3
7.1 How to input user's program .................................................................................. 22
7.2 How to use your stored programs........................................................................... 24
8. Types of Chart .......................................................................................................... 25
9. Maintenance and Repair .......................................................................................... 26
a. Fuse Replacement .................................................................................................. 26
b. Remote Control batteries Replacement ................................................................... 27
c. Cleansing .............................................................................................................. 27
d. Disposal Information .............................................................................................. 28
10. Specifications ........................................................................................................... 29
11. Components List ...................................................................................................... 30
11.1 Standard accessories ........................................................................................... 30
12. Service Information .................................................................................................. 31
4
1. Introduction
1.1. Outline of product
LUXVISION LCP-7800 is an automatic chart projector which provides 41 different charts including red/green, polarized filters, binocular balance test chart, stereoacuity test chart, fixation disparity test chart, fusion test chart and aniseikonia test chart for the eye optometry. Users can select the desired charts instantaneously by cordless remote controller. Charts move quickly and quietly. The customized two programs will help you to perform more convenient and effective examination. This automatic chart project is compatible with LUXVISION digital refractor, CDR series.
1.2. Classifications
- Type of protection against electric shock: Class I Equipment
- Degree of protection against electric shock: No applied parts
- Degree of protection against the ingress of water: Ordinary, IPX0
- Equipment not suitable for use in the presence of a flammable anesthetic mixture
with air or with oxygen or nitrous oxide.
1.3. Standards
LVD: IEC/EN60601-1
EMC: IEC/EN60601-1-2
5
1.4. EMC Information
Table 1:Guidance and manufacturer’s declaration
– electromagnetic emissions
The LCP-7800 is intended for use in the electromagnetic environment specified below. The customer or the user of the LCP-7800 should assure that it is used in such an environment.
Emissions test
Compliance
Electromagnetic
environment
- guidance
RF emissions
CISPR 11
Group
1
The LCP-7800 uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in n earby electronic equipment
RF emissions
CISPR 11
Class
A
The LCP-7800 is suitable for use in all establish ments other than domestic and those directly co nnected to the public low-voltage power supply network that supplies buildings used for domesti c purposes
Harmonic emissions
IEC 61000-3-2
Class
A
Voltage fluctuations/
Flicker emissions IEC 61000-3-3
Complies
Table 2:Guidance and manufacturer’s declaration
– electromagnetic immunity
The LCP-7800 is intended for use in the electromagnetic environment specified below. The customer or the user of the LCP-7800 should assure that it is used in such an environment.
Immunity test
IEC 60601
Test level
Compliance
level
Electromagnetic environment
-
guidance
Electrostatic
Discharge(ESD) IEC 61000-4-2
±6 kV contact
±8 kV air
±6 kV
contact ±8 kV air
Floors should be wood, concrete or
ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%.
Electrical
fast
transient/burst IEC 61000-4-4
±2 kV for power
supply lines
±2 kV for
power supply lines
Mains power quality should be that of
a typical commercial or hospital environment
Surge
IEC 61000-4-5
±1 kV
lines to lines
±2 kV lines to earth
±1 kV
lines
to lines ±2 kV lines to earth
Mains power quality should be that of
a typical commercial or hospital environment.
6
Voltage dips, short
interruptions and voltage variations on power supply input lines IEC 61000-4-11
<5%
U
T
(>95% dip in UT) For 0,5 cycle 40% U
T
(60% dip in UT) For 5 cycle 70% U
T
(30% dip in UT) For 25 cycle <5% U
T
(>95% dip in UT) For 5 cycle
<5%
U
T
(>95% dip in UT) For 0,5 cycle 40% U
T
(60% dip in
UT)
For 5 cycle 70% U
T
(30% dip in
UT)
For 25 cycle <5% U
T
(>95% dip in UT) For 5 cycle
Mains power quality should be that of a typical commercial or hospital environment. If the user of LCP-7800 requires continued operation during power mains interruptions, it is recommended that the LCP-7800 be powered from an uninterruptible power supply or a battery.
Power frequency (5
0/60Hz) magnetic fi eld IEC 61000-4-8
3A/m
3A/m
Power frequency magnetic fields sho
uld be at levels characteristic of a ty pical location in a typical commercial or hospital environment
Note: U
T
is the a.c. mains
voltage prior to application of the test level.
Table 3: Guidance and manufacturer’s declaration
– electromagnetic immunity
The LCP-7800 is intended for use in the electromagnetic environment specified below. The customer or the user of the LCP-7800 should assure that it is used in such an environment.
Immunity test
IEC 60601 test level
Compliance
level
Electromagnetic environment
-
guidance
Conducted RF IEC 61000-4-6
Radiated RF IEC 61000-4-3
3 Vrms 150 kHz to 80MHz
3 Vrms 80MHz to 2.5GHz
3V
3V/m
Portable and mobile RF communications
equipment should be used no closer to any part of the SYSTEM, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.
Recommended separation distance
P
V
d ]
5.3
[1=
P
E
d ]
5.3
[1= 80MHz to 800MHz
7
P
E
d ]
7
[1= 800MHz to 2.5GHz
Where P is the maximum output power rating of the transmitter in watts(W) according to the transmitter manufacturer and d is the recommended separation distance in metres (m).
Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey, should be less than the compliance level in each frequency range.
Interference may occur in the vicinity of equipment marked wigh the following symbol:
Recommended separation distances between portable and mobile RF communications equipment
and the LCP-7800
The LCP-7800 is intended for use in an electromagnetic environment in which radiated RF disturbances
are controlled. The customer or the user of the LCP-7800 can help prevent electromagnetic interference
by maintaining a minimum distance between portable and mobile RF communications equipment
( transmitters ) and the LCP-7800 as recommended below, according to the maximum output power of
the communications equipment.
Rated maximum
output power of
transmitter
W
Separation distance according to frequency of transmitter
m
150kHz to 80 MHz
P
V
d ]
5.3
[1=
8
0MHz to 800MHz
P
E
d ]
5.3
[1=
8
00MHz to 2.5GHz
P
E
d ]
7
[1=
0.01 0.12 0.12 0.23
0.1 0.38 0.38 0.73
1 1.2 1.2 2.3
10 3.8 3.8 7.3
100 12 12 23
8
2. Safety Information
2.1 Introduction
Safety is everyone’s responsibility. The safe use of this equipment is largely dependent upon the installer, user, operator, and maintainer. It is imperative that personnel study and become familiar with this entire manual before attempting to install, use, clean, service or adjust this equipment and any associated accessories. It is paramount that the instructions contained in this manual are fully understood and followed to enhance safety to the patient and the user/operator. It is for this reason that the following safety notices have been placed appropriately within the text of this manual to highlight safety related information or information requiring special emphasis. All users, operators, and maintainers must be familiar with and pay particular attention to all Warnings and Cautions incorporated herein.
WARNING
"Warning” indicates the presence of a hazard that could result in severe personal injury, death or substantial property damage if ignored.
CAUTION
“Caution” indicates the presence of a hazard that could result in minor injury, or property damaged if ignored.
NOTE
This is used to emphasize essential information. Be sure to read this information to avoid operating the device incorrectly.
!!!!
!!!!
9
2.2 Safety Symbols
The International Electrotechnical Commission (IEC) has established a set of symbols for medical electronic equipment, which classify a connection or warn of any potential hazards. The classifications and symbols are shown below.
ON
When the switch points to this symbol, power is being supplied to the device.
OFF
When the switch points to this symbol, power is not being
supplied to the device.
Input
Indicates the Input port.
Output
Indicates the output port.
Caution, Consult accompanying documents.
Consult instructions for use
Protective Earth Connection
Alternating Current
10
E
uropean Conformity
Dispose of Electrical and Electronic Equipment Correctly
D
ate of manufacture
Manufacturer
A
uthorized Representative in the European
Community
S
erial Number
Temperature Limitation
Humidity Limitation
Atmospheric Pressure Limitation
11
This side up
Fragile , handle with care
Do not use hand hooks
Keep Dry
Stacking Limit by Number
Loading...
+ 25 hidden pages