Complete, Easy To Read
TEMP UP MODE
FAN
MODE
TEMP DOWN
BACKLIGHT
RESET
INSTALLATION AND OPERATING INSTRUCTIONS
PSDH121 SERIES
DIGITAL ELECTRONIC HEAT PUMP THERMOSTAT
Easy as
Installs Easily
LUX PRODUCTS CORPORATION • Mt. Laurel, New Jersey 08054, USA 43368
WARNING: Use Energizer®or DURACELL®Alkaline Batteries Only.
Energizer®is a registered trademark of Eveready Battery Company, Inc.
DURACELL®is a registered trademark of The Gillette Company, Inc.
Set TemperatureChoose Heat or Cool
IMPORTANT!
Please read all instructions carefully before
beginning installation and save for future reference.
Before removing any wiring from your existing thermostat, its wires
must be labeled with their terminal designations.
Ignore the color of the wires since they may not comply with any standard.
Thank you for your confidence in our product. To obtain the best results from
your investment, please read this manual and acquaint yourself with your
purchase before installing your new thermostat. Then follow the installation
procedures, one step at a time. This will save you time and minimize the chance
of damaging the thermostat and the systems it controls. These instructions may
contain information beyond that required for your particular installation. Please
save for future reference.
COMPATIBILITY
LUX PSDH121 was designed
for use with single stage heat
pump systems with auxiliary
and/or emergency heat. These
systems are typical known as
2-stage heat one stage cool heat
pump systems.
1–2–3
OPERATING INSTRUCTIONS
●
In the winter, set the system switch to HEAT to control your system while
heating.
●
In the summer, set the switch to COOL to control your system while cooling.
●
Press the TEMPERATURE UP or DOWN key in order to show the
current SET TEMPERATURE.
●
Press TEMPERATURE UP or DOWN keys again until your desired
temperature is displayed. The display will show the current room temperature
again after two seconds.
●
Press the light bulb button to illuminate the display. Adjusting the temperature
will keep the display lit until no button has been pressed for over ten seconds.
●
In spring and fall or when windows are open, you can set the system switch
to OFF.
●
Setting the FAN switch to AUTO automatically runs your system’s fan during
heating and cooling.
●
Setting the FAN switch to ON runs your system’s fan continuously even
without heating or cooling.
●
Setting the Mode switch to EMER (emergency heat) runs your Emergency
heating system rather than the heat pump.
NOTE
The FAN switch works only if your system provides a wire for a thermostat’s “G” terminal.
INSTALLATION
Please read all instructions carefully before beginning installation.
*** Turn off electricity to the appliance before installing or
servicing thermostat or any part of the system. Do not turn
FF
O
electricity back on until work is completed. ***
●
Do not short (jumper) across electric terminals at control on furnace or air
conditioner to test the system. This will damage the thermostat and void
your warranty.
●
All wiring must conform to local codes and ordinances.
●
This thermostat is designed for use with 24 volt systems. The thermostat
should be limited to a maximum of 1.5 amps; higher current may cause
damage to the thermostat. If you are in doubt, call your HVAC contractor.
●
Your thermostat is a precision instrument. Please handle it with care.
CAUTION
FEATURES
●
Slim design may be vertically or horizontally
mounted
●
Large easy to read backlit display
●
Fan switch for system or continuous fan
operation
●
Emergency Heat Switch
●
Simple temperature Up or Down keys will
display and adjust the Set Temperature.
●
Temperature displays in F° or C°
●
Temperature differential SWING settings of
0.25 and 0.5
●
Selectable 2 or 5-Minute Minimum Run/Off time provides short cycle and
compressor protection
TOOLS REQUIRED
●
#1 Phillips screwdriver (small)
●
Drill with 3/16-in. (4.8mm) bit
●
Wire stripper/cutter
THERMOSTAT LOCATION
On replacement installations, mount the new thermostat in place of the old
one unless the conditions listed below suggest otherwise. On new installations,
follow the guidelines listed below.
●
Remember that your PSDH121 may be mounted vertically or horizontally
when determining the optimal location.
●
Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the floor,
and in a room that is used often.
●
Do not install it where there are unusual heating conditions, such as: in direct
sunlight; near a lamp, radio, television, radiator, register, or fireplace; near hot
water pipes in a wall; near a stove on the other side of a wall.
●
Do not locate in unusual cooling conditions, such as: on a wall separating an
unheated room; or in a draft from a stairwell, door, or window.
●
Do not locate in a damp area. This can lead to corrosion that will shorten
thermostat life.
●
Do not locate where air circulation is poor, such as: in a corner or an alcove;
or behind an open door.
●
Do not install the unit until all construction work and painting has been
completed.
1© COPYRIGHT 2004 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED
Read instructions carefully before removing any wiring from existing thermostat. Wires
J3J4 J2 J1
JUMPER POSITIONS
(FOR REFERENCE ONLY
NOT SHOWN TO SCALE)
CLOSE
5 min
F
Horizontal
Swing=0.5
OPEN
2 min
C
Vertical
Swing=0.25
J1
J2
J3
J4
must be labeled before they are removed. When removing wires from their terminals,
ignore the color of the wires since they may not comply with any standard.
Y
REMOVING THE OLD THERMOSTAT
W
1. Switch electricity to the furnace and air conditioner OFF; then
proceed with the following steps.
2. Remove cover from old thermostat. Most are snap-on types and
simply pull off. Some have locking screws on the side. These must
be loosened.
3. Note the letters printed near the terminals. Attach labels (enclosed) to each wire
for identification. Label and remove wires one at a time. Make sure the wires do
not fall back inside the wall.
4. Loosen all screws on the old thermostat and remove it from the wall.
MOUNTING THE PSDH121 ON THE WALL
1. Decide whether the thermostat will be mounted vertically or horizontally.
CAUTION
Be careful not to drop the unit or disturb electronic parts.
CAUTION
Y
W
4. Cup the thermostat with one hand behind the
thermostats display. Separate the unit from its base
plate using the tabs protruding from its body with
the other hand.
ATTACHING WIRES
Y
W
2. Strip insulation 3/8 in. (9.5mm) from wire ends and
R
clean off any corrosion.
3. Fill wall opening with non-combustible insulation to
prevent drafts from affecting the thermostat.
TAB
BASE
GCRW2OBYE
TERMINALS
NOTE
If you are mounting the base to a
soft material like plasterboard or if
you are using the old mounting
holes, the screws may not hold.
Drill a 3/16-in. (4.8mm) hole at
each screw location, and insert the
plastic anchors provided.
Then mount the base as
described below.
5. Route the wires through the large hole in the base plate by the
terminal block. Hold the base against the wall, with the wires
coming through. Position the base for best appearance (to hide
any marks from an old thermostat). The terminal block should be
either to the right of or below the routing hole. Attach the base to
the wall with the two screws provided.
PLEASE REVIEW THE WIRING DIAGRAMS IN THE NEXT COLUMN
FOR PROPER TERMINAL CONNECTION
Do not allow wires to touch each other or parts on thermostat. Terminated wires must
CAUTION
be trapped between black spacer and brass terminal. Securely tighten all eight electrical
INSTALLATION OPTIONS
There are four options which are set by a group of numbered jumpers on the
rear of the units circuit board. They are:
J1: The minimum run time jumper J1 sets the minimum length of time that the
thermostat must remain with Heat or Cool either on or off before it will
automatically switch to the alternate On or Off state. This feature prevents short
cycling, and provides compressor protection for cooling units. Choices are 2 or 5
minutes.
J2: The temperature format: jumper selects whether your thermostat displays
temperatures in Celsius or Fahrenheit.
J3: This Jumper determines whether the display will be horizontally or vertically
oriented.
J4: This Jumper controls the “swing” or temperature variation in the home. Using
the smaller number results in more stable temperature, while the wider setting is
provided as a more energy efficient alternative. Users of force hot water systems
may find the 0.25 setting more comfortable.
The table at left is printed on the
circuit board. To change a jumper
position. The closed or shorted
position is that which covers both a
jumpers pins. To prevent its loss, a
jumper may be placed over one pin
only for the open positions. After
settings have been changed, press
the small-unmarked RESET button on the front of the thermostat for the changes
to take effect.
INSTALL BATTERIES
For detailed instruction, see BATTERIES/MAINTENANCE to install batteries at
this time.
●
Turn the power back on to your heating and/or air conditioning system.
●
Verify that the system and its fan are operating properly. When set to a high
temperature, the heating system should provide warm air after a short time.
Likewise, a cooling system should provide cool air after a short time. Usually sound
from the furnace and air conditioning units can be heard while they are running.
The rush of moving air should be heard within a short time after either has been
started.
●
The Installation is now complete.
terminal screws.
CALIBRATION
Your thermostat is carefully calibrated at the factory, and will measure
temperature to within ±1°. However, you can adjust the reading of your
thermostat:
●
Slide the MODE switch to OFF.
●
Press and hold the Up and Down buttons until the display shows a single digit
between +5F°(+3C°) and -5F°(-3C°).
●
Then the Up or Down buttons may be used to adjust the reading.
●
The display will return to normal operation after 4 seconds without an
adjustment.