Luxor GM 1192, GM 1193 Technical Data Sheet

Technical Data Sheet
Mixing System GM 1192
Function
The mixing group GM 1192 is a regulation group which combines a number of components in a single device able to maintain a pre-set temperature in the radiant panels circuit of mixed heating systems. The temperature in the panels is kept constant by a regulating valve which mixes hot water coming from the boiler with the low temperature one circulating in the panels. The GM 1192 can be connected directly to Luxor manifolds for radiant panels by means of a G 1” male fitting with
soft seal. This makes the GM 1192 particularly convenient, since it can be kept in stock as a modular component. Moreover, the GM 1192 makes mixed heating systems extremely
flexible, since the regulation group can be adjusted to meet the future requirements of the secondary circuit. It is therefore possible to expand the radiant panels system simply by adding outlets, without temperature or pressure issues downstream of the group.
The GM 1192 can be set both to increase the heating capacity and to balance pressure drops. Finally, thanks to its great regulation capacity, the GM 1192 allows to
make the secondary circuit independent from the primary in case of replacement of important parts of the system, for example when a new boiler with a different operating principle is installed. By means of the bypass circuit, the circulation pump can keep on operating at design conditions.
This type of system can supply a max thermal power of 20 kW with a temperature of the primary circuit of ≥ 70°C.
Technical data
Max. working pressure:
6 bar
Max. differential pressure:
1 bar
Regulation range on the bypass:
0.2 ÷ 0.7 bar
Max. temperature on primary circuit:
80 °C
Max. working temperature on secondary circuit:
70 °C
Temperature adjustment range on secondary circuit:
20 ÷ 65 °C
Thermometer range:
0 ÷ 80 °C
Connections on primary circuit (to boiler):
G 1” female
Connections to secondary manifold:
G 1” male
Adjustment range of therm. head:
20 ÷ 65 °C
Length of capillary:
2 m
Materials
Mixing group
Body:
CW 617 N – DW UNI-EN 12165:2016
Obturator:
CW 614 N – DW UNI-EN 12164:2016
Gaskets:
Peroxide cured EPDM
Steel parts:
Stainless steel
Cap:
RAL9016 white ABS
Copper parts:
Nickel-plated annealed copper
Accessories
Brass parts:
CW 617 N – DW UNI-EN 12165:2016; CW 614 N – DW UNI-EN 12164:2016
Steel parts:
Stainless steel
Gaskets:
Peroxide cured EPDM
Safety valve:
Acetal
Thermostatic head
Head:
RAL9016 white ABS
Sensor:
Liquid
Thermometer
Case and stem:
Galvanised steel
Cover:
Transparent plastic material
Thermometric element:
Bimetallic spiral spring
Surface treatment
Nickel-plating
Dimensional Drawings
GM 1192
Fixed point regulation group for floor heating systems, with pump connection and thermostatic head.
GM 1193
Fixed point regulation group for floor heating systems with pump connection.
Code
Size A B C D E Code
Size A B C D
E
72000050
G1”x130mm
130
120
200
495
G1”
72000052
G1”x130mm
130
120
200
495
G1”
72000055
G1”x180mm
180
120
250
495
G1”
72000057
G1”x180mm
180
120
250
495
G1”
Code
Size F G H L M Code
Size F G H L M 72000050
G1”x130mm
G1”1/2
G1”
M30x1.5
85
32
72000052
G1”x130mm
G1”1/2
G1”
M30x1.5
85
32
72000055
G1”x180mm
G1”1/2
G1”
M30x1.5
85
32
72000057
G1”x180mm
G1”1/2
G1”
M30x1.5
85
32
Construction
1. Thermostatic regulating valve (boiler
delivery) controlled by thermostatic head with remote probe, 0-10V electrothermal head or 3-point or 0­10V electric motor
2. Pump shut-off valve
3. Ball valve for pump interception and balancing of the secondary circuit
4. Probe seat
5. Secondary circuit shut-off valve and safety valve (boiler return)
6. Bypass valve
7. Automatic air vent valve
8. Water fill/drain tap
9. 3-piece union fittings with soft sealing
10. Fitting for circulation pump connection
11. Thermometers
12. Union fittings
13. Safety thermostat seat