Luxlink RSW-3002 Operating Instructions Manual

WARRANTY
All fiber optic transmission systems, products and accessories manufactured by Liteway, Inc. and it’s subsidiaries are fully tested prior to shipment and are warranted against defective materials and workmanship for a period of five full years from the date of the original shipment. Should a problem occur, a Return Material Authorization Number (RMA) must be obtained from Liteway Inc. at (516) 931-2800 and the item returned to Liteway, Inc. 166 Haverford Road, Hicksville, NY 11801, USA, prepaid. Liteway Inc. will then, at its option repair or replace the defective item.
Liteway, Inc. maximum liability under this warranty is limited to the cost of the defective item only. No contingent liabilities of any kind are either assumed or implied.
Any items returned to Liteway, Inc. that have been misused, abused, damaged, modified, connected or adjusted in any way contrary to the instructions furnished by Liteway, Inc. or repaired by unauthorized personnel will not be covered by this warranty. Any non-warranty repairs required will be quoted at the current rate for such services.
!
CAUTION ! AVOID DIRECT EXPOSURE TO BEAM.
All –5, -7, -8, and -9 Models use laser diodes. These solid-state laser diodes are located in the optical ports of these units. Laser diodes produce invisible radiation that may be harmful to human eyes. Never look directly into the optical port of any fiber optic unit designed to operate with single-mode optical fiber.
NOT FOR LIFE SUPPORT SYSTEMS
Liteway, Inc. does not authorize or warrant any of its products or accessories for use in critical life support systems or applications of any kind.
© Copyright 2017 Liteway, Inc. 122995 Rev D
Important Notices
OPERATING INSTRUCTIONS
LuxLink®
Redundant RF Switch Model RSW-3002
The RSW-3002 is a two input single output automatic switch designed to implement a redundant, fail-safe RF transmission system with any fiber optic system.
Technical Specifications
RF Switch Bandwidth 100 Hz to 1 GHz In/Out Impedance 50 ohms Isolation 50 dB minimum Insertion Loss 1 dB maximum Signal Connectors BNC RF Rx Bandwidth 100 Hz to 750 MHz (indicator only) Rx In Signal Level +13 dBm (3V peak to peak) Rx Hysteresis 2-3 dB Indicator Lights Pwr, Primary, Secondary, Alarm Power & control connectors Temperature Range -35º to +75ºC Alarm Contact Ratings 0.5A 125 VAC 1 ampere 24 VDC Power Requirements 11-24 VAC/DC @150 mA Physical Size (mm) 5.0”(127)L x 1.0” (25.4)W x 3.0”(7)D
All specifications are subject to change without prior notice.
Removable terminal Block
Installation Instructions
The diagram below shows the typical installation of the RSW-3002.
Upon loss of the primary signal, the RSW-3002 will
Automatically switch the remaining secondary (backup) signal Activate the front panel Alarm (Alm) indicator. Sound the Alarm audio alert if enabled. Switch the external relay contacts.
Mode Switch
Setting Function
Pri Forces Primary feed to common output
Auto mode;
If there is no signal on primary feed, but a signal
Auto
Sec Forces Secondary feed to common output
on the secondary feed, the secondary feed is connected to common output. Otherwise, Primary feed connects to common output.
Audio Alert Switch
When enabled, this allows an audible alert if a fault condition is present
122995 Rev D
Indicator Lights
Indicator Lights when
Pwr Proper power is present.
Alrm* One or both input signals are not present
Pri A signal is present at Primary input
Sec A signal is present at Secondary input.
The loss of the RF signal at Input 1 (Primary) has
Fault
* Note that if the Alm indicator is enabled the output for the optional ALM-1000 Alarm Sensing Unit will also be enabled.
occurred and the RF signal at Input 2 (Backup) has been routed to the output.
3 Pin Power Terminal Block Connections
Pin Function
Alarm output for use with optional Alarm Sensing Unit
1
ALM-1000. No other connections should be made to this
terminal 2 +11 to 24 DC or AC Volts input 3 Ground, AC or DC return (Common to Housing)
Be certain to check all connections, settings and voltages before applying power
5 Pin Control Terminal Block Connector Block
Pin Function
Relay contacts (2 Amp dry contact)
1 Normally Open Contact 2 Common Contact 3 Normally Closed Contact
External control of Mode
4 Ground to Force Primary output 5 Ground to Force Secondary output