Luxibel LX119 User Manual

LX119
SMART HEXA LED PAR 12 X 12 W - RGBWAP LED
LX119
V. 01 – 19/06/2014 2 ©Velleman nv
LX119
V. 01 – 19/06/2014 3 ©Velleman nv
USER MANUAL
1. Introduction
To all residents of the European Union Important environmental information about this product
This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized company for recycling. This device should be returned to your distributor or to a local recycling service. Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for choosing Luxibel®! Please read the manual thoroughly before bringing this device into service. If the device was damaged in transit, don't install or use it and contact your dealer.
2. Safety Instructions
Be very careful during the installation: touching live wires can cause life-threatening electroshocks.
Always disconnect mains power when device not in use or when servicing or maintenance activities are performed. Handle the power cord by the plug only.
Indoor use only. Keep this device away from rain, moisture, splashing and dripping liquids. Never put objects filled with liquids on top of or close to the device.
Keep this device away from children and unauthorized users.
Caution: device heats up during use.
Do not stare directly at the light source, as this may cause
epileptic seizure in sensitive people temporarily loss of sight (flash blindness) permanent (irreversible) eye damage.
There are no user-serviceable parts inside the device. Refer to an authorized dealer for service and/or spare parts.
This is a Safety Class I device. It is therefore essential that the device be earthed. Have a qualified person carry out the electric connection.
Make sure that the available voltage does not exceed the voltage stated in the specifications of this
manual.
Do not crimp the power cord and protect it against damage. Have an authorised dealer replace it if
necessary.
Use an appropriate safety cable to fix the device (e.g. VDLSC7N or VDLSC8N). Install the device at a minimal distance of 0.5 m from flammable and explosive objects or
substances.
Respect a minimum distance of 0.5 m between the device’s light output and any illuminated surface. The maximum ambient temperature is 40 °C. Do not operate the device at higher temperatures.
3. General Guidelines
Refer to the Velleman® Service and Quality Warranty on the last pages of this manual.
Keep this device away from dust and extreme temperatures. Make sure the ventilation openings are clear at all times. For sufficient air circulation, leave at least 1" (± 2.5 cm) in front of the openings.
LX119
V. 01 – 19/06/2014 4 ©Velleman nv
Protect this device from shocks and abuse. Avoid brute force when operating the device.
Familiarise yourself with the functions of the device before actually using it. Do not allow operation
by unqualified people. Any damage that may occur will most probably be due to unprofessional use of the device.
All modifications of the device are forbidden for safety reasons. Damage caused by user modifications
to the device is not covered by the warranty.
Only use the device for its intended purpose. All other uses may lead to short circuits, burns,
electroshocks, lamp explosion, crash, etc. Using the device in an unauthorised way will void the warranty.
Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and
the dealer will not accept responsibility for any ensuing defects or problems.
Mechanical wear and LEDs are not covered by warranty. A qualified technician should install and service this device. Do not switch the device on immediately after it has been exposed to changes in temperature.
Protect the device against damage by leaving it switched off until it has reached room temperature.
This device is designed for professional use on stage, in discos, theatres, etc. The device should only
be used indoors with an alternating current of 240 VAC, 50 Hz.
Lighting effects are not designed for permanent operation: regular operation breaks will prolong their
lives.
Use the original packaging if the device is to be transported. Keep this manual for future reference.
4. Features
DMX control via 3, 4, 6, 8 or 12 channels for simple or advanced controlling
o 3 channel mode: HSV (hue, saturation, value) or HSI (hue, saturation, intensity) o 6 channel mode: RGBWAP o 8 channel mode: dimmer, RGBWAP, shutter o 12 channel mode: dimmer, RGBWAP, shutter, macro, auto, auto speed, dimmer curve
built-in programmes with speed adjustment static colour selection, with white colour temperature pre-setting from 3200 to 10000 K master/slave mode for synchronized operation of multiple units linked in a chain flicker-free operation (400 Hz) clear LCD for easy menu setting
5. Overview
Refer to the illustrations on page 2 of this manual.
1
mounting bracket
7 control panel
2
locking nut
8 safety cable attachments
3
DMX input (5-pole XLR)
9 power input (powerCON)
4
DMX input (3-pole XLR)
10
power output (powerCON)
5
DMX output (5-pole XLR)
11
ground point
6
DMX output (3-pole XLR)
12
fuse holder
6. Installation
Choose a suitable mounting spot. Mount the device in the desired angle using the included bracket. Connect the power cord to the mains. Disconnect after use.
Mounting the Device
Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable
norms.
The carrying construction must be able to support 10 times the weight of the device for 1 hour
LX119
V. 01 – 19/06/2014 5 ©Velleman nv
without deforming.
The installation must always be secured with a secondary attachment e.g. a safety cable. Never stand directly below the device when it is being mounted, removed or serviced. Have a
qualified technician check the device once a year and once before you bring it into service.
Install the device in a location with few passers-by that is inaccessible to unauthorised persons. Overhead mounting requires extensive experience: calculating workload limits, determining the
installation material to be used… Have the material and the device itself checked regularly. Do not
attempt to install the device yourself if you lack these qualifications as improper installation may result in injuries.
For truss mounting, use an appropriate clamp (not incl.) and fit an M10 bolt through the centre of the
(folded) bracket.
Adjust the desired inclination angle via the mounting bracket and tighten the bracket screws. Make sure there is no flammable material within a 0.5 m radius of the device. Have a qualified electrician carry out the electric connection. Connect the device to the mains with the power plug. All devices must be powered directly off a
grounded switched circuit. Do not connect to a dimmer pack.
The device has a power output [10] to supply power to another device. When connecting several
devices in a daisy chain via this output, make sure that the total current does not exceed the power line’s nominal current. Use power cables with an adequate section.
The installation has to be approved by an expert before the device is taken into service.
DMX-512 Connection
When applicable, connect an XLR cable to the female XLR output of a controller (not incl.) and the
other side to the male XLR input [3 or 4] of the device. Multiple devices can be linked through serial linking. The linking cable should be a dual core, screened cable with XLR input and output connectors.
Maximum recommended serial data link distance is 500 meters (1640 ft). Maximum recommended
number of devices on a serial data link is 32 devices.
A DMX terminator is recommended for installations where the DMX cable has to run a long distance
or is in an electrically noisy environment (e.g. discos). The terminator prevents corruption of the digital control signal by electrical noise. The DMX terminator is simply an XLR plug with a 120 Ω resistor between pins 2 and 3, which is then plugged into the XLR output socket [5 or 6] of the last device in the chain.
7. Operation
The device can be used in the following modes:
stand-alone mode master/slave with a DMX512 controller.
7.1 Control Panel
Access the control panel functions using the four panel buttons located directly underneath the display [7]. From left to right:
Button
Function
MENU
access the menu return to a previous menu option
UP
scroll through the menu options in ascending order increase value
DOWN
scroll through the menu options in descending order decrease value
ENTER
select menu option store the current menu or option within the menu
LX119
V. 01 – 19/06/2014 6 ©Velleman nv
7.2 Auto Mode
If no DMX control signal is present at the DMX input [3 or 4], the unit independently runs through its show programme (if the blackout mode is switched off).
1. Press MENU until <AUTO> appears on the display. Press ENTER to confirm.
2. Select one of the auto programmes (programme 0-4) with UP or DOWN. Press ENTER to confirm.
3. Set the running speed (0-100 %) with UP or DOWN. Press ENTER to save the setting.
IMPORTANT: The auto programmes 0-4 are fully pre-programmed and will not be altered by changes.
Instead, the <MANU C> mode allows combining the colours RGBWAP (red, green, blue, white, amber, purple).
1. Press MENU until <STATIC> appears on the display. Press ENTER to confirm.
2. Select <MANU C> with UP or DOWN and press ENTER to confirm.
3. Select the colour (RGBWAP) with UP or DOWN and press ENTER to confirm.
4. Set the value (000-255) with UP or DOWN. Press ENTER to save the setting.
5. Press MENU to go back.
7.3 Static Mode
This unit has the ability to accept custom static colour settings.
1. Press MENU until <STATIC> appears on the display. Press ENTER to confirm.
2. Select <FIXT C> with UP or DOWN and press ENTER to confirm.
3. Select the colour with UP or DOWN and press ENTER to confirm.
4. Press MENU to go back.
7.4 Master/Slave Mode
This mode allows you to link up several units together without using a controller. Choose the first in the chain to function as master unit; other connected units will work as slave units with the same effect.
1. Press MENU until <M&S> appears on the display. Press ENTER to confirm.
2. According the master or slave unit, select <MASTER> or <SLAVE> with UP or DOWN and press
ENTER to confirm.
3. Select the desired programme (see 7.3 Auto Mode).
4. Use standard DMX cables to daisy chain your units together via the DMX connections [3 or 4 + 5 or
6] on the rear of each unit. We suggest using a terminator on the last unit for longer cable runs (see 7.10 Construction of the DMX Termination).
7.5 Linking
Several units may be interconnected in order to control all further slave units to the same effect as the master unit.
1. Connect the DMX output [5 or 6] of the master unit to the DMX input [3 or 4] of the first slave unit
using an appropriate cable with XLR connector.
2. Connect the DMX output [5 or 6] of the first slave unit to the DMX input [3 or 4] of the next slave
unit using an appropriate cable with XLR connector, until all units are connected in a chain.
7.6 DMX Configuration
This device is equipped with different DMX configurations.
1. Press MENU until <CHANNEL> appears on the display. Press ENTER to confirm.
2. Select the desired DMX configuration (6ch, 8ch, 12ch, HSV or HSI) with UP or DOWN and press
ENTER to confirm.
3. Refer to chapter 7.11 DMX Value per Channel to set each channel.
7.7 DMX Mode
1. Press MENU until <ADDRESS> appears on the display. Press ENTER to confirm.
2. Select the desired value (001-512) with UP or DOWN (hold UP or DOWN pressed to scroll rapidly)
and press ENTER to confirm.
3. Press MENU to go back.
All DMX-controlled devices need a digital start address so that the correct device responds to the
signals. This digital start address is the channel number from which the device starts to “listen” to
the DMX controller. The same starting address can be used for a whole group of devices or an individual address can be set for every device.
LX119
V. 01 – 19/06/2014 7 ©Velleman nv
When all devices have the same address, all the units will “listen” to the control signal on one
particular channel. In other words: changing the settings of one channel will affect all devices
simultaneously. If you set individual addresses, each device will “listen” to a separate channel
number. Changing the settings of one channel will only affect the device in question.
Example of a configuration with 8 channels:
number of
channels
start address
(example)
DMX address
occupied
next possible start address
for unit n°1
next possible start address
for unit n°2
next possible start address
for unit n°3
8
33
33-40
41
49
57
DMX address 33
DMX address 41
DMX address 49
DMX address 57
DMX512 controller
7.8 Connection of the DMX Line
When applicable, connect an XLR cable to the female XLR output of a controller (not incl.) and the
other side to the male XLR input [3 or 4] of the device. Multiple devices can be linked through serial linking. The linking cable shall be a dual core, screened cable with XLR input and output connectors.
Maximum recommended serial data link distance is 500 meters (1640 ft). Maximum recommended
number of devices on a serial data link is 32 devices.
7.9 Construction of the DMX Termination
A DMX terminator is recommended for installations where the DMX cable has to run a long distance
or is in an electrically noisy environment (e.g. discos). The terminator prevents corruption of the digital control signal by electrical noise. The DMX terminator is simply an XLR plug with a 120 Ω resistor between pins 2 and 3, which is then plugged into the XLR output socket of the last device in the chain
7.10 DMX Value per Channel
HSV mode:
channel
from
to
description
1
000
255
hue
2
000
255
saturation
3
000
255
value (brightness)
HSI mode:
channel
from
to
description
1
000
255
hue 2 000
255
saturation
3
000
255
intensity
LX119
V. 01 – 19/06/2014 8 ©Velleman nv
6-channel mode:
channel
from
to
description
1
000
255
red 0-100 %
2
000
255
green 0-100 %
3
000
255
blue 0-100 %
4
000
255
amber 0-100 %
5
000
255
white 0-100 %
6
000
255
purple 0-100 %
8-channel mode:
channel
from
to
description
1
000
255
dimmer 0-100 %
2
000
255
red 0-100 %
3
000
255
green 0-100 %
4
000
255
blue 0-100 %
5
000
255
amber 0-100 %
6
000
255
white 0-100 %
7
000
255
purple 0-100 %
8
000
10
no function
011
255
strobe slow-fast
12-channel mode:
channel
from
to
description
1
000
255
dimmer 0-100 %
2
000
255
red 0-100 %
3
000
255
green 0-100 %
4
000
255
blue 0-100 %
5
000
255
amber 0-100 %
6
000
255
white 0-100 %
7
000
255
purple 0-100 %
8
000
10
no function
011
255
strobe slow-fast
9
000
10
no function
011
30
red 100 % / green 0-100 % / blue 0 %
031
50
red 100-0 % / green 100 % / blue 0 %
051
70
red 0 % / green 100 % / blue 0-100 %
071
90
red 0 % / green 100-0 % / blue 100 %
091
110
red 0-100 % / green 0 % / blue 100 %
111
130
red 100 % / green 0 % / blue 100-0 %
131
150
red 100 % / green 0-100 % / blue 0-100 %
151
170
red 100-0 % / green 100-0 % / blue 100 %
171
200
red 100 % / green 100 % / blue 100 % / white 100 %
201
205
colour temperature 1
206
210
colour temperature 2
211
215
colour temperature 3
216
220
colour temperature 4
221
225
colour temperature 5
226
230
colour temperature 6
231
235
colour temperature 7
236
240
colour temperature 8
241
245
colour temperature 9
246
250
colour temperature 10
251
255
colour temperature 11
LX119
V. 01 – 19/06/2014 9 ©Velleman nv
10
000
10
no function
011
60
auto programme 1
061
120
auto programme 2
121
180
auto programme 3
181
240
auto programme 4
241
255
auto programme 0 (auto 1-4)
11
000
255
auto speed slow-fast
12
000
51
preset dimmer speed from control panel
052
101
dimmer speed mode off
102
152
dimmer speed mode 1 (fast)
153
203
dimmer speed mode 2 (middle)
204
255
dimmer speed mode 3 (slow)
7.11 White Balance
Enter this option to adjust the white balance.
1. Press MENU until <WHITE BALANCE> appears on the display. Press ENTER to confirm.
2. Select the colour (R, G or B) with UP or DOWN and press ENTER to confirm.
3. Set the value (000-255) with UP or DOWN. Press ENTER to save the setting.
4. Press MENU to go back.
7.12 Fixture Settings and Information
Dimmer
Selection of the dimming curve.
1. Press MENU until <DIM MODE> appears on the display. Press ENTER to confirm.
2. Select the dimming curve (off, DIM1, DIM2 or DIM3) with UP or DOWN and press ENTER to confirm.
3. Press MENU to go back.
BackLite
Activation of the display backlight.
1. Press MENU until <BACKLITE> appears on the display. Press ENTER to confirm.
2. Select the activation time (on, 10s, 20s or 30s) with UP or DOWN and press ENTER to confirm.
3. Press MENU to go back.
Auto Test
Start the automatic test function to check if the device is working properly.
1. Press MENU until <INFO> appears on the display. Press ENTER to confirm.
2. Select <AUTO> with UP or DOWN.
3. Press ENTER to confirm and to start the automatic testing.
FixHours
Shows the device’s working hours.
1. Press MENU until <INFO> appears on the display. Press ENTER to confirm.
2. Select <FIXHOURS> with UP or DOWN and press ENTER to confirm.
3. Press MENU to go back.
Version
Shows the device’s firmware version.
1. Press MENU until <INFO> appears on the display. Press ENTER to confirm.
2. Select <VERSION> with UP or DOWN and press ENTER to confirm.
3. Press MENU to go back.
Temp
Shows the device’s working temperature.
1. Press MENU until <TEMP> appears on the display. Press ENTER to confirm.
2. Press MENU to go back.
LX119
V. 01 – 19/06/2014 10 ©Velleman nv
8. Cleaning and Maintenance
All screws should be tightened and free of corrosion. The housing, the lenses, the mounting supports and the installation location (e.g. ceiling, suspension,
trussing) should not be deformed, modified or tampered with; e.g. do not drill extra holes in mounting supports, do not change the location of the connections…
Mechanically moving parts must not show any signs of wear and tear. The electric power supply cables must not show any damage. Have a qualified technician maintain
the device.
Disconnect the device from the mains prior to maintenance activities. Let the device cool down. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents. Do not immerse the device in any liquid. There are no user-serviceable parts, apart from the fuse. Contact your dealer for spare parts if necessary.
Replacing the Fuse
Only replace the fuse by a fuse of the same type and rating.
1. Before replacing the fuse, unplug the mains lead.
2. Unscrew the fuse holder [12] with an appropriate screwdriver.
3. Remove the old fuse and install the new fuse in the fuse holder.
4. Place the fuse holder back in the housing and tighten it.
9. Technical Specifications
power supply
100-240 VAC 50/60 Hz
power consumption
180 W
IP rate
IP44
LEDs
12 x 12 W RGBWAP high-power LED
beam angle
25°
field angle
34°
dimensions
298 x 240 x 273 mm
weight
4.5 kg
Use this device with original accessories only. Velleman nv cannot be held responsible in the event of damage or injury resulting from (incorrect) use of this device. For more info concerning this product and the latest version of this manual, please visit our website www.luxibel.com. The information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE The copyright to this manual is owned by Velleman nv. All worldwide rights reserved. No part
of this manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise without the prior written consent of the copyright holder.
Velleman® Service an d Qua lity Wa rr an ty
Since its foundation in 1972, Velleman® acquired extensive experience in the electronics world and curren tly di stri b utes its pro ducts in ov er 85 cou ntrie s.
All our prod ucts fulfil strict quality requirements and legal stipulations in the EU. In order to ensure the quality, our products regularly go through an extra quality check, both by an internal quality department and by specialized external organisations. If, all precautionary measures notwithstanding, problems should occur, please make appeal to our warranty (see guarantee conditions).
General Warranty Conditions Concerning Consumer Products (for EU):
• All consumer products are subject to a 24-month warranty on production flaws and defective material as from the original date of purchase.
• Velleman® can decide to replace an article with an equivalent article, or to refund the retail value totally or partially when the complaint is valid and a free repair or replacement of the article is impossible, or if the expenses are out of proportion.
You will be delivered a replacing article or a refund at the value of 100% of the purchase price in case of a flaw occurred in the first year after the d ate of purchase and delivery, or a re plac in g ar t icle at 50% of the pur chase price or a refund at the value of 50% of the retail value in case of a flaw occurred in the second year after the date of purchase and delivery.
• No t c ov e red by w a rranty:
- all direct or indirect damage caused after delivery to the article (e.g. by oxidation, shocks, falls, dust, dirt, humidity...), and by the article, as well as its contents (e.g. data loss), compens ation for loss of profits;
- consumable goods, parts or accessories that are subject to an aging process during normal use, such as batteries (rechargea ble, non-rechargeable, built-in or replaceable), lamps, rubber par ts, dr ive belts. .. (u nl im ited lis t);
- flaws resulting from fire, water damage, lightning, accident, natural disaste r, etc.…;
- flaws caused deliberately, negligently or resul ti ng f ro m im pr ope r ha n dl in g, ne g li gent maintenance, abusive use or use contrary to the manufacturer’s instructions;
- damage caused by a commercial, professional or collective use of the article (the warranty validity will b e reduced to six (6) months when the article is used professionally);
- damage resulting from an inappropriate packing and shipping of the article;
- all damage caused by modification, repair or alteration performed by a third party without writ te n permis sio n by Ve l le ma n ®.
• Articles to be repaired must be delivered to your Velleman® dealer, solidly packed (preferably in the original packaging), and be completed with the original receipt of purchase and a clear flaw description.
• Hint: In order to save on cost and time, please reread the manual and check if the flaw is caused by obvious causes prior to presenting the article for repair. Note that returning a non­defective article can also involve handling costs.
• Repairs occurring after warranty expiration are subject to shipping costs.
• The above conditions are without prejudice to all commercial warranties.
The above enumeration is subject to modification according to the article (see art icl e ’s manual ) .
Made in PRC
Imported by Velleman nv
Legen Heirweg 33, 9890 Gavere, Belgium
www.velleman.eu
Loading...