DESCRIPTION
The heat pump condensing unit is the outdoor part of a versatile
system of heating and air conditioning. It is designed to be custom-matched with one of UPG’s complete line of evaporator
sections, with each serving a specific function. Matching Air
Handlers are available for upflow, downflow, or horizontal applications to provide a complete system. Electric Heaters are
available, if required. Add-on coils are available for use with
upflow, downflow, or horizontal furnaces and air handlers.
WARRANTY
Single Phase Units:
5-year limited parts warranty.
5-year limited compressor warranty.
FEATURES
• QUALITY CONDENSER COILS - The coil is constructed of
copper tubing and enhanced aluminum fins for increased
efficiency and corrosion protection.
• PROTECTED COMPRESSOR - The compressor is internally protected against high pressure, temperature, and
externally by a factory installed high pressure switch. This is
accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protects the
compressor if undesirable operating conditions occur. A liquid line filter-drier further protects the compressor.
• DURABLE FINISH - The cabinet is made of pre-painted
steel. The pre-treated galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted-textured finish insure
less fading when exposed to sunlight.
• LOWER INSTALLED COST - Installation time and costs are
reduced by easy power and control wiring connections.
Available in sweat connect models only. The unit contains
enough refrigerant for matching indoor coils and 15 feet of
interconnecting piping. The small base dimension means
less space is required on the ground or roof.
• TOP DISCHARGE - The warm air from the top mounted fan
is blown up away from the structure and any landscaping.
This allows compact location on multi-unit applications.
• LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise away from the living area.
The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan motor and compressor
operating sounds.
• LOW MAINTENANCE - Long life permanently lubricated
motor-bearings need no annual servicing.
• EASY SERVICE ACCESS - Fully exposed refrigerant connections, and a single panel covering the electrical controls
make for easy servicing of the unit.
• SECURED SERVICE VALVES - Secured re-usable service
valves are provided on both the liquid and vapor sweat connections for ease of evacuating and charging.
• U.L. and C.U.L. listed - approved for outdoor application.
• Agency Listed - U.L. and C.U.L. listed - approved for outdoor application. The unit is certified in accordance with the
Unitary Small Equipment cerification program, which is
based on ARI Standard 210/240.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
445073-LTG-A-0109
B
C
A
Physical and Electrical Data
MODEL
THRD18
S41S1
THRD24
S41S1
THRD30
S41S1
THRD36
S41S1
THRD42
S41S1
THRD48
S41S1
THRD60
S41S1
Unit Supply Voltage208-230V, 1 60Hz
Normal Voltage Range
Compressor Type RecipRecipRecipRecipRecipRecipScroll
Compressor Amps
Rated Load8.39.311.314.715.717.227.5
Locked Rotor434354748884135
Crankcase HeaterYesYesYesYesYesYesNo
Fan Motor AmpsRated Load0.80.80.81.51.51.51.5
Fan Diameter Inches18182224242424
Rated HP1/81/81/81/41/41/41/4
Fan Motor
Nominal RPM107510751075850850850850
Nominal CFM20002000250035003500390023.58
Face Area Sq. Ft.9.39.312.815.715.723.623.6
Coil
Rows Deep 1111112
Fin / Inches18181822222218
Liquid Line Set OD (Field Installed)3/83/83/83/83/83/83/8
Vapor Line Set OD (Field Installed)3/43/43/43/47/87/87/8
Unit Charge (Lbs. - Oz.)
4
5 - 65 - 87 - 87 - 88 - 89 - 113 - 1
Charge Per Foot, Oz.0.620.620.620.620.670.670.67
Operating Weight Lbs.145145176193198248290
1. Rated in accordance with ARI Standard 110, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15
feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
2Johnson Controls Unitary Products
All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request.
1. For applications requiring a TXV use the correct 1TVM* series kit listed above.
2. Approved orifice shipped with outdoor unit.
3. Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224.
4. PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of interconnecting
line tubing.
2. Verify the TXV or orifice and additional charge required for specific evaporator coil in the system using the above table.
3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data Table.
4. For TXV match charge weight needs to be weighed in for specififc coil match and lineset length.
5. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator
+ adder for line set.
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
— = Not applicable.
COOLING
NET MBH
SEEREER
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils
1. Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
** Refer to Quick Selection Chart for specific furnace match-up.
COOLING
NET MBH
SEER
1
EER
4Johnson Controls Unitary Products
COOLING CAPACITY - With Variable Speed Furnaces
UNIT
MODEL
THRD18S41S1
THRD24S41S1
THRD30S41S1
THRD36S41S1
THRD42S41S1
THRD48S41S1
THRD60S41S1
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Variable speed furnaces have B.O.D (Blower on Delay) standard.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no
supplemental electric heat operation.
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.
AIR
HANDLER
13 SEER HP WITH MV - VARIABLE SPEED
13 SEER HP WITH AV - VARIABLE SPEED
1
COIL
MODEL
13 SEER HP WITH F6FP
MBHCOPKWMBHCOPKWSTD
47F17FHSPF
ARI HEATING
2
6Johnson Controls Unitary Products
445073-LTG-A-0109
HEATING PERFORMANCE - Upflow, Downflow, and Horizontal Furnaces and Coils
UNIT
MODEL
COIL
MODEL
1
47F17FHSPF
MBHCOPKWMBHCOPKWSTD
ARI HEATING
60S41S1FC/MC62 56.5 3.48 4.76 35.4 2.42 4.29 8.00
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no
supplemental electric heat operation.
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.
HEATING CAPACITY - With Variable Speed Furnaces (Continued)
UNIT
MODEL
THRD42S41S1
THRD48S41S1
THRD60S41S1
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no
supplemental electric heat operation.
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.