SPLIT-SYSTEM AIR CONDITIONERS
16 SEER – R-410A
MODELS:
AL6B024 THRU 060
(2 THRU 5 NOMINAL TONS)
Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at
www.upgnet.com and www.luxaire.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY
Standard 5-year limited parts warranty.
10-year limited compressor warranty.
Premium System Warranty - Limited lifetime compressor
when matched with an approved Johnson Controls Unitary
Products premium furnace and coil or premium air handler.
Extended 10-year limited parts warranty when product is
registered online within 90 days of purchase for replacement or closing for new home construction.
LISTED
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
567177-LTG-D-1211
DESCRIPTION
The 16 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available for
typical applications, this climate system is supported with
accessories and documents to serve specific functions.
FEATURES
• Superior Coil Protection – A decorative, stamped metal coil
guard completely protects coil from debris and other large
damaging material.
• Isolated Compressor Compartment – A molded composite
bulkhead isolates the compressor from the rest of the unit,
reducing sound and vibration.
• Protected Compressors – Each compressor is protected
against abnormal pressures by an internal pressure relief
valve and factory installed high and low pressure controls.
Additional protection against moisture and debri s is provided
by factory installed liquid line filter driers.
• Environmentally Friendly Refrigerant – Next generation
refrigerant R-410A delivers environmentally friendly performance with zero ozone depletion.
• Durable Finish – Automotive quality finish provides the ultimate protection from harmful U.V. rays and rust creep,
ensuring long-lasting, high quality appearance. A powderpaint topcoat is applied over a baked-on primer, using a galvanized, zinc coated steel base material. The result is a finish that has been proven in testing to provide 33% greater
durability than conventional powder-coat finishes.
• Lower Installed Cost – Designed to provide enhanced
installability by featuring a slide-down control compartment
and angled service valves to reduce overall installation time
and cost.
• Low Operating Sound Levels – A fan design boasting technology adapted from aeronautic and defense engineering
provides for whisper quiet operation by allowing airflow to
flow smoothly and efficiently across the fan tips.
• Filter-Drier – A factory installed, solid core liquid line filterdrier filters harmful debris and moisture from the system.
• Easy Service Access – A full end, full service, access panel
with handle makes for easy entry to internal components.
• Composite Base - Strong and durable composite base pan
resists rust and corrosion while it helps reduce vibrations and
noise.
TM
• SilentDrive
wing fan, composite base pan, isolated compressor compartment, and single-stage compressor to reduce overall sound
to a mere whisper.
• Low RPM fan motor - Helps to reduce airflow noise.
• Communications Capable – Requiring only a simple 4-wire
installation, the communicating capability enables the use of
the Touch Screen Communicating Control, allowing real time
visibility of system operation and the use of diagnostic features, while still maintaining the ability to function with a traditional thermostat.
• Agency Listed - U.L. and C.U.L. listed - approved for outdoor application. The unit is certified in accordance with the
Unitary Small Equipment certification program, which is
based on AHRI Standard 210/240.
System - Features combination of swept-
567177-LTG-D-1211
VAPOR
LIQUID
2-3/8
3-1/8
6-1/2
C
A
B
PHYSICAL AND ELECTRICAL DATA
MODELAL6B024F3(C) AL6B030F3(C) AL6B036F3(C) AL6B042F3(C)AL6B048F3(C) AL6B060F3(C)
Unit Supply Voltage208-230V, 1 60Hz
Multi-Stage CompressorNo No No No No No
Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll
Compressor Amps
Rated Load13.414.117.317.921.121.4
Locked Rotor58.373.096.7112106135
Crankcase HeaterNo No No No No No
Factory External Discharge MufflerNoNoNoNoNoNo
Factory External Check ValveNoNoNoNoNoNo
HS Kit Required with TXV
4
NoNoNoNoNoNo
Fan Motor AmpsRated Load0.50.51.31.31.32.8
Fan Diameter Inches222222222424
Rated HP1/151/151/41/41/41/3
Fan Motor
Nominal RPM850850850850850917
Nominal CFM202020453240330038003900
Face Area Sq. Ft.14.1013.9716.1219.3422.8222.82
Coil
Rows Deep111111
Fins / Inch232323232323
Liquid Line Set OD (Field Installed)3/8 3/8 3/8 3/8 3/8 3/8
Vapor Line Set OD (Field Installed)3/4 3/4 3/4 7/8 7/8 1-1/8
Unit Charge (Lbs. - Oz.)
5
3 - 124 - 65 - 06 - 46 - 56 -14
Charge Per Foot, Oz.0.620.620.620.670.670.75
Operating Weight Lbs.159166192209225235
1. Rated in accordance with ANSI/AHRI Standard 110-2002, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model.
5. The Unit Charge is correct for the outdoor unit, matched indoor coil, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet,
add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
187 to 252
All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request.
2Johnson Controls Unitary Products
Unit
Model
Dimensions
(Inches)
ABCLiquidVapor
Refrigerant Connection
Service Valve Size
02429-1/23731
03633-1/23731
04239-1/23731
3/8”
04839-1/24234
06039-1/242347/8” *
* Expander fitting required for 1-1/8” line set.
3/4”03029-1/23731
7/8”
567177-LTG-D-1211
System Charge for Various Matched Systems
Outdoor Unit AL6B024F3(C) AL6B030F3(C) AL6B036F3(C) AL6B042F3(C) AL6B048F3(C) AL6B060F3(C)
Approved System Thermal Expansion Valve
Indoor Coil
AHE24B9–––––
AHE30B90––––
AHE36C1560–––
AHE42D–933– –
AHE48D–13774–
AHE60D––121294
AHP3090––––
AHP36–60–––
AHP42––0–––
AHP48–––74–
AHP60–––74–
AHR24B9–––– –
AHR30B–0––– –
AHR36B–60–– –
AHR42C––33––
AHR48D–––74–
AHR60D–––1294
AV*361560–––
AV*48––774–
AV*60–––740
AHX244–––––
AHX30120––––
AHX361560–––
AHX42––33––
AHX48––774–
AHX60––121294
F6FP03090––––
F6FP03690––––
F6FP042–933––
F6FP048–13774–
F6FP060––121294
F4FV060––774–
FC/MC/PC3290––––
FC/MC/PC3590––––
FC/MC/PC371560–––
FC/MC/PC4315600––
FC/MC/PC48–9330–
FC/MC/PC60–137740
FC/MC62––121294
FC64––18181511
HD48––330–
HD60––774–
UC48–93–0–
UC60–13774–
Some of the combinations shown in the above System Charge table require Advanced Main Air Circulating Fan indoor product. For approved coil
only matches, please see the “COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils” table.
FOOTNOTES:
1. For applications requiring a TXV use S1-1TVM*** series kit.
2. Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit S1-2FD06700224.
3. PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.
4. Refer to Cooling Performance Data tables for actual performance for specified system matches.
5. A TXV kit must be used with these coils to obtain system performance.
Note: If a TXV is factory installed on the coil, it must be replaced with the listed TXV.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator, and 15 feet of interconnecting
2. Verify the TXV and additional charge required for specific evaporator coil in the system using the above table.
3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data Table.
4. For TXV matches requiring additional charge, the refrigerant needs to be weighed in for specific coil match and lineset length.
5. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + charge adder for
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and AHRI Standard 210/240.
Cooling MBH based on 8°F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95 °F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
— = Not applicable.
MA Modular Air Handlers use Coil Only Ratings.
COOLING
NET MBH
SEEREER
6Johnson Controls Unitary Products
567177-LTG-D-1211
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Coil Only Ratings)