LUTZE IP67 DIOSWITCH Operating Instructions Manual

Operating Instructions
IP67 DIOSWITCH
10/100 Base–T with 8 Ports
Part-No. 745569
Version 1.09
02/07/2017
Lütze Transportation GmbH Bruckwiesenstraße 17-19 D-71384 Weinstadt Tel.: +49 (0) 7151 6053-545 Fax: +49 (0) 7151 6053-6545 Sales.Transportation@luetze.de www.luetze-transportation.de
IP67 DIOSWITCH Content
Content
1 Introduction....................................................................................................... 4
2 General Information.......................................................................................... 5
2.1 Symbol Description...................................................................................................................... 5
2.2 Copyright ..................................................................................................................................... 5
2.3 Disclaim of Liability ...................................................................................................................... 5
3 Safety ................................................................................................................. 6
3.1 Content of the Manual ................................................................................................................. 6
3.2 Intended Use ............................................................................................................................... 6
3.3 Recepients................................................................................................................................... 6
3.4 Operating Employees .................................................................................................................. 6
3.5 Responsibility of the Operator ..................................................................................................... 7
3.6 Protective Clothing and Equipment ............................................................................................. 7
3.7 Other Safety Instructions ............................................................................................................. 7
4 Transport and Storing ...................................................................................... 9
5 Scope of Delivery............................................................................................ 10
6 Product Overview ........................................................................................... 11
6.1 The Technology ......................................................................................................................... 12
6.2 Supported Ethernet Functions ................................................................................................... 12
6.3 Possible Applications................................................................................................................. 13
6.4 Diagnostics and LED Displays................................................................................................... 14
7 Technical Data ................................................................................................ 15
7.1 Block Diagram ........................................................................................................................... 17
7.2 Power Supply of the IP67 DIOSWITCH..................................................................................... 18
7.3 Ports of the IP67 DIOSWITCH .................................................................................................. 19
8 Functional Description................................................................................... 20
8.1 General Functions ..................................................................................................................... 20
8.1.1 Behaviour when applying the voltage ........................................................................................ 20
8.1.2 Link Detection ............................................................................................................................ 20
8.1.3 Auto Negotiation ........................................................................................................................ 20
8.1.4 Signal Generation ...................................................................................................................... 20
8.1.5 Auto Crossing ............................................................................................................................ 21
8.2 Specific Functions...................................................................................................................... 22
8.2.1 Link control ................................................................................................................................ 22
8.2.2 Auto Polarity Exchange ............................................................................................................. 22
9 Maintenance .................................................................................................... 23
10 Final Shutdown and Disposal........................................................................ 24
11 Service ............................................................................................................. 25
12 Revision of the Document ............................................................................. 26

1 Introduction

This manual is part of the IP67 DIOSWITCH. It contains important information about the handling and safety. To avoid hazardous situations read the manual before installing the product and using it.
Store the manual at a handy place. If selling, renting or in case of a divestiture pass the manual to the authorize person.
IP67 DIOSWITCH Introduction
4
IP67 DIOSWITCH General Information

2 General Information

2.1 Symbol Description

The manual contains several safety messages. Each safety message contains a defined signal word and a color. The color and the word are referring to an alert level. There are 4 levels. The safety messages point out hazardous situations and give information to avoid those.
Indicates a hazardous situation which, if not avoided will result in death or serious injury.
Indicates a hazardous situation which, if not avoided could result in death or serious injury.
Indicates a hazardous situation which, if not avoided could result in minor or moderate injury.
Is used to address practices not related to personal injury.

2.2 Copyright

This manual is intended for the operator and his staff. It is forbidden to give the content to a third party, to duplicate, exploit or impart it. The Lütze Transportation GmbH has to allow it explicit in writing.
General data, text, images and drawings are copyrighted and are liable to the industrial property right. Contravention can be prosecuting criminally. The named brands and product names in this document are trademarks or registered trademarks by titleholder.

2.3 Disclaim of Liability

The manual was written under consideration of the applied standards, regulations and the current state of technology. The content is verified of accuracy. Discrepancies are not excluded. For those discrepancies we disclaim liability. Applicable changes and additional information will be in the next version of the manual.
The Lütze Transportation GmbH does not assume liability for any damages and accidents of following reasons:
Nonobservance of the manual
Untrained and unqualified employees
Non conventional use
Non approved reconstructions and functional modifications of the product
Using non original or non admitted parts or equipment
5

3Safety

3.1 Content of the Manual

Read and follow the manual before using the product the first time. This applies to every person which is getting in touch with the product. Trained employees and experts especially qualified persons which had worked with similar products before have to read and understand the manual.

3.2 Intended Use

Appropriate use includes compliance with the operating instructions.
The DIOSWITCH must only be used for the intended cases provided in the technical documents and only in combination with the third party equipment and components recommended or approved by us.
The fault-free and reliable operation of the product requires proper transport, storage, installation, assembly, operation and maintenance.
A 24 V DC power supply is used for the power supply of the DIOSWITCH.
The operating voltage of 24 V DC is in the category SELV (Safety Extra Low Voltage) or PELV (Protective Extra Low Voltage) and is thus not subject to the EC Low Voltage Directive. The use of other power supplies is not permitted.
IP67 DIOSWITCH Safety

3.3 Recepients

The operating manual addresses planers, project manager and programmers. It also addresses the operating employees which are responsible for the initial operation, the operation and for the maintenance of the products and systems. Regarding the employees three qualification levels are differentiated.

3.4 Operating Employees

Risk of injury by deploying insufficient qualified operating employees.
Inappropriate appoint of not qualified or insufficient personnel can cause property damages and personal injuries. Tasks which apply special procedures should be done by trained and qualified employees or experts, especially electricians.
Trained Employees
The employee was trained by the employer on the task and possible hazardous situations. The employee does not have any technical knowledge.
Experts
The employee has a technical education, knowledge and/or experience in the required field. The employee is capable to do specific operations on and with the product.
Electrically qualified persons
The employee has a technical education in the required field. The employee is capable to do special operations on and with the product.
The different sections of the manual refering to the qualification level of the operating employees.
6

3.5 Responsibility of the Operator

The operator is obligate by the law of occupational safety, if the product is used in a commercial field.
The operator is responsible to train the employees and to inform himself about
the industrial safety regulation.
The operator is responsible that safety, environment protection regulations
and rules for accident prevention are observed.
The operator has to run a risk assessment at the working environment/place
of installation to expose hazards and to alert those.
The manual has to be stored near the product.
The manual has to be obeyed.
The product can just be run in a faultless technical condition.

3.6 Protective Clothing and Equipment

Destroyed parts and malfunction of the product. Inappropriate clothes
can cause electrification and can damage the product. If working with or on the I/O Modules wear special ESD clothing.
IP67 DIOSWITCH Safety
Also follow the instructions and regulations of the employer.

3.7 Other Safety Instructions

The DIOSWITCH corresponds to the state of the art and satisfies the applicable safety conditions and the corresponding, harmonised European standards (EN).
The following are applicable for the user:
relevant accident prevention regulations
EC Directives or other country-specific regulations
generally recognised technical safety rules
general ESD regulations.
The modules must be disconnected from the mains power supply
(unplug mains plug) when installation or maintenance work is performed. Accidents due to electrical voltages can be avoided in this way.
Personal injuries and property damages caused by reconstructions
and modifications of the product. Do not reconstruct or modify the product
if the manufacturer does not allow it explicit in writing.
This is a Class A device. This device can cause radio interference in
residential areas. In this case, the operator can be requested to perform appropriate actions.
7
IP67 DIOSWITCH Safety
If electrical welding work is performed on the frame where electronic
components are installed, all connections to and from these components must be disconnected in advance. It is only in this way that
the modules can be protected from destruction due to compensating currents.
Any kind of faults or other damage must be reported to a responsible person.
Protection and safety devices must not be bypassed or rendered ineffective.
Dismantled safety devices must be reinstalled before starting up again and must be subjected to a functional test.
The modules must be secured against misuse or inadvertent use.
Originally applied warning and information signs, lettering, stickers or similar
must always be observed and maintained in a legible condition.
8
IP67 DIOSWITCH Transport and Storing

4 Transport and Storing

Protect the product against humidity. Store the product in a dry room
between -40 and 85°C.
Make sure that the module is safely packaged for transporting, to
absorbe possible crushes.
9
Loading...
+ 18 hidden pages