![](/html/5a/5abb/5abb21d4a7a3456c1f9f628a5b7a91f0cfe4f786a3e01ccdaeea26cf39e3b335/bg1.png)
SD card real time datalogger, RS232/USB
VIBRATION METER
Model : VB-8206SD
Your purchase of this
VIBRATION METER with
SD CARD DATALOGGE
you into the field of
precision measurement.
Althou
h this METER is a
complex and delicate
instrument, its durable
structure will allow many
years of use if proper
operatin
techniques are
developed. Please read the
followin
instructions
carefully and always keep
this manual within easy
reach.
OPERATION MANUAL
![](/html/5a/5abb/5abb21d4a7a3456c1f9f628a5b7a91f0cfe4f786a3e01ccdaeea26cf39e3b335/bg2.png)
TABLE OF CONTENTS
1. FEATURES............................................................................... 1
2. SPECIFICATIONS..................................................................... 2
3. FRONT PANEL DESCRIPTION.................................................... 8
3-1 Display................................................................................................. 8
3-2 Power Button ( ESC, Backli
ht Button )................................................... 8
3-3 Hold Button ( Function Button, Next Button ).......................................... 8
3-4 REC Button ( Enter Button, Unit Button )...............................................
8
3-5 SET Button ( Button, Time check Button )..........................................
er Button ( Button, Sampling time check Button, Zero Button )▲
Max hold reset Button )........................................................................ 8
3-7 BNC Input Socket.................................................................................
8
3-8 SD Card Socket..................................................................................... 8
3-9 RS-232 Output Terminal........................................................................ 8
3-10 Reset Button......................................................................................
8
3-11 DC 9V Power Adapter Input Socket......................................................
8
3-12 Battery Compartment/Cover................................................................
8
3-13 Battery Cover Screws.......................................................................... 8
3-14 Stand................................................................................................. 8
3-15 Tripod Fix Nut..................................................................................... 8
3-16 Ma
netic base.................................................................................... 8
3-17 Vibration Sensor................................................................................. 8
3-18 Input Socket of Vibration Sensor .........................................................
of Cable................................................................................8
3-20 Sensor Cable......................................................................................
................................................................................... 8
4. MEASURING PROCEDURE......................................................... 9
4-1 Preparation..........................................................................................
9
4-2 Unit selection ( Acc./Velocity/Displacement selection ).............................
10
4-3 Function selection ................................................................................11
4-4 Zero ad
ustment procedures...................................................................12
4-5 Data Hold.............................................................................................13
4-6 Data Record ( Max./ Min. readin
).........................................................13
ht ON/OFF...........................................................................14
5. DATALOGGER..........................................................................14
5-1 Preparation before execute datalo
er function.......................................14
5-2 Auto Datalo
er ( Set sampling time 1 second ).................................≧ 15
er ( Set sampling time = 0 second )..............................16
5-4 Check time information.........................................................................
time information............................................................17
5-6 SD Card Data structure.........................................................................
17
6. Saving data from the SD card to the computer...........................19
7. ADVANCED SETTING................................................................20
7-1 Set clock time ( Year/Month/Date, Hour/Minute/ Second )........................21
7-2 Decimal point of SD card settin
.............................................................22
ement ...............................................................22
7-4 Set beep Sound ON/OFF........................................................................23
7-5 Set samplin
time ................................................................................ 23
7-6 SD memory card format........................................................................
23
8. POWER SUPPLY from DC ADAPTER...........................................
24
9. BATTERY REPLACEMENT..........................................................24
10. SYSTEM RESET......................................................................25
11. RS232 PC serial interface........................................................25
12. CLASSIFICATION RANGES......................................................
27
13. SENSITIVITY RELATIVE according ISO 2954............................
28
14. PATENT.................................................................................29
![](/html/5a/5abb/5abb21d4a7a3456c1f9f628a5b7a91f0cfe4f786a3e01ccdaeea26cf39e3b335/bg3.png)
1. FEATURES
* Applications for industrial vibration monitoring :
All industrial machinery vibrates. The level of vibration is
a useful guide to machine condition. Poor balance,
misalignment & looseness of the structure will cause the
vibration level increase, it is a sure sign that the
maintenance is needed.
* Frequency range 10 Hz - 1 kHz, sensitivity relative meet
ISO 2954.
* Professional vibration meter supply with vibration sensor
& magnetic base, full set.
* Metric & Imperial display unit
* Acceleration, Velocity, Displacement measurement.
* RMS, Max hold, Peak value measurement.
* Max. Hold reset button, Zero button.
* Wide frequency range.
* Data hold button to freeze the desired reading.
* Memory function to record maximum and minimum
reading with recall.
* Separate vibration probe with magnetic base, easy operation.
* Real time SD memory card Datalogger, it Built-in Clock
and Calendar, real time data recorder , sampling time set
from 1 second to 3600 seconds.
* Manual datalogger is available ( set the sampling
time to 0 ), during execute the manual datalogger
function, it can set the different position ( location ) No.
( position 1 to position 99 ).
* Innovation and easy operation, computer is not need
to setup extra software, after execute datalogger, just
take away the SD card from the meter and plug in the
SD card into the computer, it can down load the all the
measured value with the time information (
year/month/date/ hour/minute/second ) to the Excel
directly, then user can make the further data or graphic
analysis by themselves.
1
![](/html/5a/5abb/5abb21d4a7a3456c1f9f628a5b7a91f0cfe4f786a3e01ccdaeea26cf39e3b335/bg4.png)
* SD card capacity : 1 GB to 16 GB.
* LCD with green light backlight, easy reading.
* Can default auto power off or manual power off.
* Data hold, record max. and min. reading.
* Microcomputer circuit, high accuracy.
* Power by UM3/AA ( 1.5 V ) x 6 batteries or DC 9V adapter.
* RS232/USB PC COMPUTER interface.
2. SPECIFICATIONS
2-1 General Specifications
Circuit Custom one-chip of microprocessor LSI
circuit.
Display LCD size : 52 mm x 38 mm
LCD with green backlight ( ON/OFF ).
Measurement Velocity, Acceleration, Displacement
Function
Acceleration, Velocity :
RMS, Peak, Max Hold.
Displacement :
p-p ( peak-peak ), Max Hold p-p.
Unit
Measurement Metric Imperial
Acceleration meter/s^2, g ft/s^2,
Velocity mm/s, cm/s inch/s
Displacement mm inch
Frequency 10 Hz to 1 KHz
range
* Sensitivity relative during the
the frequency range meet ISO 2954
Refer to table 1, page 28
Circuit Exclusive microcomputer circuit.
Peak
Acceleration, Velocity :
Measurement To measure and update the peak
value.
Displacement :
To measure and update the peak to
peak ( p-p ) value.
2
![](/html/5a/5abb/5abb21d4a7a3456c1f9f628a5b7a91f0cfe4f786a3e01ccdaeea26cf39e3b335/bg5.png)
Max Hold
Acceleration, Velocity :
Measurement To measure and update the max. peak
value.
Displacement :
To measure and update the max.
peak to peak ( p-p ) value.
Zero Button Under Acceleration ( RMS ) measurement,
sensor motionless , press Logger Button
( 3-6, Fig. 1 ) > 5 seconds.
Max. Hold Reset Under Max. hold measurement, press
Button Logger Button ( 3-6, Fig. 1 ) > 5 seconds.
Datalogger Auto 1 second to 3600 seconds
Sampling Time
@ Sampling time can set to 1 second,
Setting range
but memory data may loss.
Manual Push the data logger button
once will save data one time.
@ Set the sampling time to
0 second.
@ Manual mode, can also select the
1 to 99 position ( Location ) no.
Memory Card SD memory card 1 GB to 16 GB.
Advanced * Set clock time ( Year/Month/Date,
setting Hour/Minute/ Second )
* Decimal point of SD card setting
* Auto power OFF management
* Set beep Sound ON/OFF
* Set sampling time
* SD memory card Format
Data error no. 0.1 % no. of total saved data typically.≦
Data Hold Freeze the display reading.
* Only available for the RMS function.
Memory Recall Maximum & Minimum value.
* Only available for the RMS function.
3
![](/html/5a/5abb/5abb21d4a7a3456c1f9f628a5b7a91f0cfe4f786a3e01ccdaeea26cf39e3b335/bg6.png)
Data Output RS 232/USB PC computer interface.
* Connect the optional RS232 cable
UPCB-02 will get the RS232 plug.
* Connect the optional USB cable
USB-01 will get the USB plug.
Sampling Time Approx. 1 second.
of Display
Operating 0 to 50 .℃
Temperature Less than 85% R.H.
and Humidity
Power Supply
*
Alkaline or heavy duty DC 1.5 V battery
( UM3, AA ) x 6 PCs, or equivalent.
*
DC 9V adapter input. ( AC/DC power
adapter is optional ).
Power Current Normal operation ( w/o SD card save
data and LCD Backlight is OFF) :
Approx. DC 15 mA.
When SD card save the data and LCD
Backlight is OFF) :
Approx. DC 36 mA.
Weight
Meter :
515 g/ 1.13 LB.
Probe with cable and magnetic base :
99 g/0,22 LB
Dimension
Meter :
203 x 76 x 38 mm
Vibration sensor probe:
Round 16 mm Dia. x 37 mm.
Cable length : 1.2 meter.
Accessories * Instruction manual........................1 PC
Included * Hrad carrying case, CA-06.............1 PC
* Vibration sensor with cable...........
1 PC
* Magnetic base..............................1 PC
Optional SD Card ( 2 G )
Accessories AC to DC 9V adapter.
USB cable, USB-01.
RS232 cable, UPCB-02.
Data Acquisition software,SW-U801-WIN.
4
![](/html/5a/5abb/5abb21d4a7a3456c1f9f628a5b7a91f0cfe4f786a3e01ccdaeea26cf39e3b335/bg7.png)
2-2 Electrical Specifications (23±5 )℃
Acceleration ( RMS, Peak, Max Hold )
Unit m/s^2
Range 0.5 to 199.9 m/s^2
Resolution 0.1 m/s^2
Accuracy ± ( 5 % + 2 d ) reading
@ 160 Hz, 80 Hz, 23 ± 5 ℃
Calibration 50 m/S^2 ( 160 Hz )
Point
Unit g
@ 1 g = 9.8 m/s^2
Range 0.05 to 20.39 G
Resolution 0.01 G
Accuracy ± ( 5 % + 2 d ) reading
@ 160 Hz, 80 Hz, 23 ± 5 ℃
Calibration 50 m/S^2 ( 160 Hz )
Point
Unit ft/s^2
Range 2 to 656 ft/s^2
Resolution 1 ft/s^2
Accuracy ± ( 5 % + 2 d ) reading
@ 160 Hz, 80 Hz, 23 ± 5 ℃
Calibration 50 m/S^2 ( 160 Hz )
Point
Remark :
RMS : To measure the true RMS value.
Peak : To measure and update the peak value.
Max. Hold : To measure and update the max. peak value.
5
![](/html/5a/5abb/5abb21d4a7a3456c1f9f628a5b7a91f0cfe4f786a3e01ccdaeea26cf39e3b335/bg8.png)
Velocity ( RMS, Peak, Max Hold )
Unit mm/s
Range 0.5 to 199.9 mm/s
Resolution 0. 1 mm/s
Accuracy ± ( 5 % + 2 d ) reading
@ 160 Hz, 80 Hz, 23 ± 5 ℃
Calibration 50 mm/s ( 160 Hz )
Point
Unit cm/s
Range 0.05 to 19.99 cm/s
Resolution 0. 01 cm/s
Accuracy ± ( 5 % + 2 d ) reading
@ 160 Hz, 80 Hz, 23 ± 5 ℃
Calibration 50 mm/s ( 160 Hz )
Point
Unit inch/s
Range 0.02 to 7.87 inch/s
Resolution 0.01 inch/s
Accuracy ± ( 5 % + 2 d ) reading
@ 160 Hz, 80 Hz, 23 ± 5 ℃
Calibration 50 mm/s ( 160 Hz )
Point
Remark :
RMS : To measure the true RMS value.
Peak : To measure and update the peak value.
Max. Hold : To measure and update the max. peak value.
6
![](/html/5a/5abb/5abb21d4a7a3456c1f9f628a5b7a91f0cfe4f786a3e01ccdaeea26cf39e3b335/bg9.png)
Displacement ( p-p, Max Hold p-p )
Unit mm
Range 1.999 mm
Resolution 0.001 mm
Accuracy ± ( 5 % + 2 d ) reading
@ 160 Hz, 80 Hz, 23 ± 5 ℃
Calibration 0.141 mm ( 160 Hz )
Point
Unit inch
Range 0.078 inch
Resolution 0.001 inch
Accuracy ± ( 5 % + 2 d ) reading
@ 160 Hz, 80 Hz, 23 ± 5 ℃
Calibration 0.141 mm ( 160 Hz )
Point
Remark :
p-p :
To measure the Peak to Peak value.
Max. Hold p-p :
To measure and update the max. Peak to Peak value.
@ Above specification tests under the environment RF Field Strength
less than 3 V/M & frequency less than 30 MHz only.
7
![](/html/5a/5abb/5abb21d4a7a3456c1f9f628a5b7a91f0cfe4f786a3e01ccdaeea26cf39e3b335/bga.png)
3. FRONT PANEL DESCRIPTION
3-1 Display
3-2 Power Button ( ESC, Backlight Button
3-3 Hold Button ( Function Button, Next Button
3-4 REC Button ( Enter Button, Unit Button
3-5 SET Button ( Button, Time check Button
▼
3-6 Logger Button ( Button, Sampling time check Button, Zero Button, ▲
Max
3-7 BNC Input Socket
3-8 SD Car
3-9 RS-232 Output Termina
3-10 Reset Button
3-11 DC 9V Power Adapter Input Socket
3-12 Battery Compartment
Cover
3-13 Battery Cover Screws
3-14 Stan
3-15 Tripod Fix Nut
3-16 Ma
netic Base
3-17 Vibration Sensor
3-18 Input Soc
et of Vibration Sensor
3-19 Mini Plug of Cable
3-20 Sensor Ca