![](/html/b1/b1d7/b1d7dd643f2d8c7335f701f52648e8a1d92077881c0578ab6f1eaca7445795f7/bg1.png)
Type K/J /T/E/R/S, Pt 100 ohm
4 channels. T1, T2, T3, T4, T1-T2
SD card real time Data Recorder, RS232/USB
4 CHANNELS THERMOMETER
Model : TM-947SD
Your purchase of this 4
CHANNELS
HERMOMETER with
SD CARD DATA
RECORDER marks a
step forward for you
into the field of
precision measurement.
Although this METER is
a complex and delicate
instrument, its durable
structure will allow
many years of use if
proper operating
techniques are
developed. Please read
the following
instructions carefully
and always keep this
manual within easy
reach.
OPERATION MANUAL
![](/html/b1/b1d7/b1d7dd643f2d8c7335f701f52648e8a1d92077881c0578ab6f1eaca7445795f7/bg2.png)
TABLE OF CONTENTS
1. FEATURES.............................................................................1
2. SPECIFICATIONS...................................................................2
3. FRONT PANEL DESCRIPTION..................................................6
3-1 Display............................................................................6
3-2 Power Button ( ESC, Backli
ht Button )..............................6
3-3 Hold Button ( Next Button )..............................................6
3-4 REC Button ( Enter Button ).............................................6
3-5 Type Button ( Button, L Button )...................................▲ 6
3-6 T1-T2 Button ( Button, R Button ).................................▼ 6
3-7 SET Button ( Time check Button )....................................
er Button ( OFFSET Button, Sampling time check Butto6
3-9 T1,T2,T3,T4 input socket ( Type K, Type J ).......................6
3-10 PT1 input socket ( Pt 100 ohm ).....................................6
3-11 PT2 input socket ( Pt 100 ohm ).....................................6
3-12 RS-232 output terminal..................................................
6
3-13 DC 9V adapter socket.....................................................6
3-14 Tripod Fix Nut................................................................6
3-15 Battery Cover Screws.....................................................
6
3-16 Battery compartment/Cover............................................6
3-17 Stand............................................................................6
3-18 SD card socket...............................................................6
4. MEASURING PROCEDURE.......................................................7
4-1 Type K measurement.......................................................7
4-2 Type J/T/E/R/S measurement...........................................7
4-3 Pt 100 ohm measurement................................................
8
4-4 T1-T2 measurement.........................................................8
4-5 Data Hold........................................................................9
4-6 Data Record ( Max./ Min. readin
)....................................9
4-7 LCD Backli
ht ON/OFF......................................................10
5. DATALOGGER........................................................................10
5-1 Preparation before execute datalo
er function..................10
5-2 Auto Datalo
er ( Set sampling time 1 second )............≧ 11
er ( Set sampling time = 0 second ).........12
5-4 Check time information....................................................
time information.......................................13
5-6 SD Card Data structure.....................................................13
6. Savin
data from the SD card to the computer.........................14
7. ADVANCED SETTING.............................................................
15
7-1 Set clock time ( Year/Month/Date, Hour/Minute/ Second )...16
7-2 Decimal point of SD card settin
........................................17
ement ..........................................17
7-4 Set beeper Sound ON/OFF................................................18
7-5 Select the temperature unit to or ............................℃℉ 18
7-6 Set samplin
time ........................................................... 19
7-7 SD memory card format...................................................
19
8. POWER SUPPLY from DC ADAPTER.........................................
20
9. BATTERY REPLACEMENT........................................................20
10. RS232 PC serial interface......................................................20
11. OFFSET ADJUSTMENT..........................................................22
12. Optional Type K Temp. probe...............................................
24
12. PATENT..............................................................................
![](/html/b1/b1d7/b1d7dd643f2d8c7335f701f52648e8a1d92077881c0578ab6f1eaca7445795f7/bg3.png)
1. FEATURES
* Type K/J/T/E/R/S, Pt 100 ohm, measurement with 4 display.
* Show 4 channels display on the LCD at the same time.
* Type K : -100 to 1300 .℃
* Type J : -100 to 1200 .℃
* Pt 100 ohm : -199.9 to 850.0 .℃
* / , 0.1 degree/1 degree.℃℉
* 4 channels ( T1, T2, T3, T4 ), T1-T2.
* Microcomputer circuit provides intelligent function
and high accuracy.
* Offset adjustment for the Type K/J/T/E/R/S measurement.
* Offset adjustment for the Pt 100 measurement.
* Measuring unit can select to or .℃℉
* Real time SD memory card Datalogger, it Built-in Clock
and Calendar, real time data recorder, sampling time set
from 1 second to 3600 seconds.
* Manual datalogger is available ( set the sampling
time to 0 second ), during execute the manual datalogger
function, it can set the different position ( location ) No.
( position 1 to position 99 ).
* Innovation and easy operation, computer is not need to
setup extra software, after execute datalogger, just take
away the SD card from the meter and plug in the SD card
into the computer, it can down load the all the measured
value with the time information ( year/month/date/
hour/minute/second ) to the Excel directly, thenuser can
make the further data or graphic analysis by themselves.
* SD card capacity : 1 GB to 16 GB.
* LCD with green light backlight, easy reading.
* Can default auto power off or manual power off.
* Data hold, record max. and min. reading.
* Microcomputer circuit, high accuracy.
* Power by UM3/AA ( 1.5 V ) x 6 batteries or DC 9V adapter.
* RS232/USB PC COMPUTER interface.
* Heavy duty & compact housing case.
1
![](/html/b1/b1d7/b1d7dd643f2d8c7335f701f52648e8a1d92077881c0578ab6f1eaca7445795f7/bg4.png)
2. SPECIFICATIONS
2-1 General Specifications
Circuit Custom one-chip of microprocessor LSI
circuit.
Display LCD size : 52 mm x 38 mm
LCD with green backlight ( ON/OFF ).
Channels T1, T2, T3, T4, T1-T2.
Sensor type Type K thermocouple probe.
Type J/T/E/R/S thermocouple probe.
PT 100 ohm probe
*
Cooperate with an 0.00385 alpha
coefficient, meet DIN IEC 751.
Resolution 0.1/1, 0.1/1 .℃℃ ℉ ℉
Datalogger Auto 1 second to 3600 seconds
Sampling Time
@ Sampling time can set to 1 second,
Setting range
but memory data may loss.
Manual Push the data logger button
once will save data one time.
@ Set the sampling time to
0 second.
@ Manual mode, can also select the
1 to 99 position ( Location ) no.
Memory Card SD memory card. 1 GB to 16 GB.
Advanced * Set clock time ( Year/Month/Date,
setting Hour/Minute/ Second )
* Decimal point of SD card setting
* Auto power OFF management
* Set beep Sound ON/OFF
* Set temperature unit to or ℃℉
* Set sampling time
* SD memory card Format
2
![](/html/b1/b1d7/b1d7dd643f2d8c7335f701f52648e8a1d92077881c0578ab6f1eaca7445795f7/bg5.png)
Temperature Automatic temp. compensation for the
Compensation type K/J/T/E/R/S thermometer.
Linear Linear Compensation for the full range.
Compensation
Offset Available for Type K/J/T/E/R/S and
Adjustment Pt 100 ohm.
Probe Input Type K/J/T/E/R/S
Socket 2 pin thermocouple socket.
Pt 100 ohm : Ear phone socket.
Over Indication Show " - - - - ".
Data Hold Freeze the display reading.
Memory Recall Maximum & Minimum value.
Sampling Time Approx. 1 second.
of Display
Data Output RS 232/USB PC computer interface.
* Connect the optional RS232 cable
UPCB-02 will get the RS232 plug.
* Connect the optional USB cable
USB-01 will get the USB plug.
Power off Auto shut off saves battery life or
manual off by push button.
Operating 0 to 50 .℃
Temperature
Operating Less than 85% R.H.
Humidity
Power Supply
*
Alkaline or heavy duty DC 1.5 V battery
( UM3, AA ) x 6 PCs, or equivalent.
*
DC 9V adapter input. ( AC/DC power
adapter is optional ).
3
![](/html/b1/b1d7/b1d7dd643f2d8c7335f701f52648e8a1d92077881c0578ab6f1eaca7445795f7/bg6.png)
Power Current Normal operation ( w/o SD card save
data and LCD Backlight is OFF) :
Approx. DC 8.5 mA.
When SD card save the data but and
LCD Backlight is OFF) :
Approx. DC 30 mA.
* AIf LCD backlight on, the power
consumption will increase approx.
14 mA.
Weight 278 g/0.61 LB ( meter only ).
Dimension 177 x 68 x 45 mm
(7.0 x 2.7x 1.9 inch)
Accessories * Instruction manual......................1 PC
Included
Optional * Type K thermocouple probe.
Accessories TP-01, TP-02A. TP-03, TP-04, TP-05.
* Pt 100 ohm probe, TP-101.
* SD Card ( 1 GB )
* SD Card ( 2 GB )
* USB cable, USB-01.
* RS232 cable, UPCB-02.
* Data Acquisition software,
SW-U801-WIN., SW-E802.
* AC to DC 9V adapter.
* Hard carrying case, CA-06.
* Soft carrying case, CA-05A.
2-2 Electrical Specifications (23±5 )℃
PT 100 ohm
Resolution Range Accuracy
0.1 ℃ -199.9 to 850.0 ℃ ± ( 0.4 % + 1 )℃
0.1 ℉ -327.0 to 999.9 ℉ ± ( 0.4 % + 1.8 )℉
1 ℉ 1000 to 1562 ℉ ± ( 0.4 % + 2 )℉
*
Pt 100 ohm probe TP-101 is the optional accessory.
4
![](/html/b1/b1d7/b1d7dd643f2d8c7335f701f52648e8a1d92077881c0578ab6f1eaca7445795f7/bg7.png)
Type K/J/T/E/R/S
Sensor Resolution Range Accuracy
Type
ype K 0.1 ℃ -50.1 to -100.0 ℃ ± ( 0.4 % + 1 )℃
-50.0 to 999.9 ℃ ± ( 0.4 % + 0.5 )℃
1 ℃ 1000 to 1300 ℃ ± ( 0.4 % + 1 )℃
0.1 ℉ -58.1 to -148.0 ℉ ± ( 0.4 % + 1.8 )℉
-58.0 to 999.9 ℉ ± ( 0.4 % + 1 )℉
1 ℉ 1000 to 2372 ℉ ± ( 0.4 % + 2 )℉
ype J 0.1 ℃ -50.1 to -100.0 ℃ ± ( 0.4 % + 1 )℃
-50.0 to 999.9 ℃ ± ( 0.4 % + 0.5 )℃
1 ℃ 1000 to 1150 ℃ ± ( 0.4 % + 1 )℃
0.1 ℉ -58.1 to -148.0 ℉ ± ( 0.4 % + 1.8 )℉
-58.0 to 999.9 ℉ ± ( 0.4 % + 1 )℉
1 ℉ 1000 to 2102 ℉ ± ( 0.4 % + 2 )℉
ype T 0.1 ℃ -50.1 to -100.0 ℃ ± ( 0.4 % + 1 )℃
-50.0 to 400.0 ℃ ± ( 0.4 % + 0.5 )℃
0.1 ℉ -58.1 to -148.0 ℉ ± ( 0.4 % + 1.8 )℉
-58.0 to 752.0 ℉ ± ( 0.4 % + 1 )℉
ype E 0.1 ℃ -50.1 to -100.0 ℃ ± ( 0.4 % + 1 )℃
-50.0 to 900.0 ℃ ± ( 0.4 % + 0.5 )℃
0.1 ℉ -58.1 to -148.0 ℉ ± ( 0.4 % + 1.8 )℉
-58.0 to 999.9 ℉ ± ( 0.4 % + 1 )℉
1 ℉ 1000 to 1652 ℉ ± ( 0.4 % + 2 )℉
ype R 1 ℃ 0 to 1700 ℃ ± ( 0.5 % + 3 )℃
1 ℉ 32 to 3092 ℉ ± ( 0.5 % + 5 )℉
ype S 1 ℃ 0 to 1500 ℃ ± ( 0.5 % + 3 )℃
1 ℉ 32 to 2732 ℉ ± ( 0.5 % + 5 )℉
Remark :
a. Accuracy value is specified for the meter only.
b. Accuracy is tested under the meter's environment temperature
within 23 ± 5 .℃
c. Linearity Correction :
Memorize the thermocouple's curve into the intelligent CPU
circuit,
@ Above specification tests under the environment RF Field Strength
less than 3 V/M & frequency less than 30 MHz only.
5
![](/html/b1/b1d7/b1d7dd643f2d8c7335f701f52648e8a1d92077881c0578ab6f1eaca7445795f7/bg8.png)
3. FRONT PANEL DESCRIPTION
Fig. 1
3-1 Display.
3-2 Power Button ( ESC, Backlight Button )
3-3 Hold Button ( Next Button )
3-4 REC Button ( Enter Button )
3-5 Type Button ( Button, L Button )▲
3-6 T1-T2 Button ( Button, R Button )▼
3-7 SET Button ( Time check Button )
3-8 Logger Button ( OFFSET Button, Sampling time check Button)
3-9 T1,T2,T3,T4 input socket ( Type K, Type J )
3-10 PT1 input socket ( Pt 100 ohm )
3-11 PT2 input socket ( Pt 100 ohm )
3-12 RS-232 output terminal
3-13 DC 9V adapter socket
3-14 Tripod Fix Nut
3-15 Battery Cover Screws
3-16 Battery compartment/Cover
3-17 Stand
3-18 SD card socket
6