Lutron Electronics SL-4112 Operation Manual

auto range + type K Temp. optional Humidity, Light, Anemometer
SOUND LEVEL METER
Model : SL-4112
Y
our purchase of this SOUND LEVEL METER marks a step forward for you into the field o
f
precision measurement.
A
lthough this METER is a complex and delicate instrument, its durable structure will allow many years of use if proper operating techniques are developed. Please read the following instructions carefully and always keep this manual within easy reach.
OPERATION MANUAL
TABLE OF CONTENTS
1. FEATURES...............................................................1
2. SPECIFICATIONS.....................................................2
2-1 Electrical specification for Sound level meter...............2
2-2 Electrical specification for Type K/J thermometer........
.
4
2-3 General specification.................................................4
2-4 Electrical specifications for optional probe EM-900P.....5
3. FRONT PANEL DESCRIPTION....................................8
3-1 Microphone.............................................................
.
8
3-2 Display....................................................................8
3-3 Power Button ( Send Button )...................................8
3-4 Hold Button ( ESC Button ) ......................................8
3-5 REC/Max. Min. Button.............................................. 8
3-6 Mode Button ( Lo
gg
er Button, Enter Button ) ............8
3-7 A/C Wei
g
hting Button ( / Button )......................
.
℃℉ 8
3-8 F/S Button ( Time Wei
g
hting Button ) /Unit Button....8
3-9 PH Button ( Peak Hold Button ) /Settin
g
Button......... 8
3-10 Temperature input socket........................................8
3-11 EM-900P probe input socket....................................
.
8
3-11A Probe lock switch..................................................8
3-12 Screws for battery cover..........................................8
3-13 Tripod Fix Nut.........................................................8
3-14 Stand.....................................................................8
3-15 Battery compartment / Cover...................................8
3-16 AC Output Socket...................................................
.
8
3-17 Sound Calibration VR...............................................8
3-18 RS232 Computer Interface Socket............................8
3-19 DC 9V Power Adapter Input Socket..........................8
4. MEASURING PROCEDURES.......................................9
4-1 Sound level meter..............................................9
4-2 Type K/J thermometer........................................12
4-3 EM-900P ( Humidity, Anemometer, Light ) ..........13
4-4 Data Logger.......................................................14
5. FURTHER SETTING..................................................15
5-1 Thermometer, type K. type J selection.......................
.
16
5-2 Auto power ON/OFF..................................................16
5-3 Chan
g
e the data logger sampling time........................17
5-4 To show the balance data numbers in the memory.....
.
17 5-5 Clear the existin
g
saving data from the memory..........17
5-6 Code enterin
g
for the further calibration usage...........18
6. SIGNAL OUTPUT......................................................18
6-1 AC output..........................................................18
6-2 RS232 computer interface...................................18
7. REPLACEMENT of BATTERY......................................20
8 CALIBRATION OF SOUND LEVEL METER...................
.
20
9. HOW TO SEND THE DATA OUT FROM THE METER....21
10. FREQUENCY WEIGHTING CHARACTERISTICS
OF A & C NETWORKS.............................................
22
11. TIME WEIGHTING (FAST & SLOW)
CHARACTERISTICS.................................................
22
1. FEATURES
* Large LCD display, easy to read. * Frequency and Time weighting meet IEC 61672 class 2. * A, C frequency weighting networks is selected. * Time weighting (Fast & Slow) dynamic characteristic modes. * 0.5" standard microphone head. * AC output for system expansion. * RS232 computer interface. * Auto range & Manual range selection. * Available for external calibration adjustment. * Condenser microphone for high accuracy & long-term stability. * Memory function to store the Max. & Min. value. * Hold and MAX. Hold functions. * Build in type K and type J thermometer. * Optional probe ( EM-900P ) for Humidity/Temp., Light and Anemometer measurement. * DC 1.5 V battery ( UM-4, AAA ) X 6 or DC 9V adapter in. * Operation key used push button. * LCD display for low power consumption & clear read-out even in bright ambient light condition. * Using the durable, long-lasting components, including a strong, light weight ABS-plastic housing case. * Small and light weight design allow one hand operation. * Patent.
1
2. SPECIFICATIONS
2-1 Electrical specification for Sound level mete
r
Function dB ( A & C frequency weighting ), Time
wei
g
hting ( Fast, Slow), Hold, Memory ( Max. & Min. ), Peak hold, AC output, RS232 output.
Meter default Range set to auto range. function Frequency weighting set to A weighting.
Time weighting set to fast.
Measurement 30 - 130 dB. Ran
g
e Resolution 0.1 dB. Range selector
Auto range :
30 to 130 dB.
Manual range :
3 range, 30 to 80 dB, 50 to 100 dB, 80 to 130 dB, 50 dB on each step, with over & under ran
g
e indicating. Frequency 31.5 to 8,000 Hz. Microphone type Electric condenser microphone.
Microphone size Out size, 12.7 mm DIA. ( 0.5 inch). Frequency weighting Characteristics of A & C. network
* A weighting :
The characteristic is simulated as "Human Ear Listing" response. Typical, if making the environmental sound level measurement, always select to A weighting.
* C weighting :
The characteristic is near the "FLAT" response. Typical, it is suitable for checking the noise of machinery (Q.C. check) & knowing the sound pressure level of the tested equipment.
2
Range selector Manual range: 3 ranges ( 30 to 80 dB,
50 to 100 dB, 80 to 130 dB ).
Auto range: 30 - 130 dB. Time weighting Fast - t= 200 ms, Slow - t = 500 ms, ( Fast & Slow ) * "Fast" range is simulated the
human ear response time.
* "Slow" range is easy to get the avg.
values of vibration sound level.
* The "Fast" & "Slow" response
range are designed to meet IEC 61672
class 2 requirement. Calibrator B & K (Bruel & kjaer), MULTIFUCTION
ACOUSTIC CALIBRATOR 4226. Output Signal
* AC output :
AC 0.5 Vrms corresponding to each ran
g
e step.
Out put impedance - 600 ohm.
* RS232 output.
Output terminal
Terminal 1 :
RS232 computer interface terminal, photo couple isolated.
Terminal 2 :
AC output terminal.
Terminal socket size :
3.5 mm dia. phone socket.
Calibration VR Build in external calibration VR, easy to
calibrate on 94 dB level by screw driver.
3
2-2 Electrical specification for Type K/J thermometer
Sensor Reso- Range Accuracy Type lution
Type K 0.1 -50.0 to 1300.0 ± ( 0.4 % + 0.8 )
-50.1 to -199.9 ± ( 0.4 % + 1 )
0.1 -58.0 to 2372.0 ± ( 0.4 % + 1.5 )
-58.1 to -327.8 ± ( 0.4 % + 1.8 )
Type J 0.1 -50.0 to 1100.0 ± ( 0.4 % + 0.8 )
-50.1 to -199.9 ± ( 0.4 % + 1 )
0.1 -58.0 to 2012.0 ± ( 0.4 % + 1.5 )
-58.1 to -327.8 ± ( 0.4 % + 1.8 )
*
Accuracy value is specified for the meter only.
*
Temp. probe ( Type K, TP-01 TP-02A, TP-03. TP-04 ) is the optional accessories.
2-3 General specification
Display 51 mm x 37 mm LCD (Liquid crystal
display), 5 digits with annunciator. Operating Temp. 0 to 50 ( 32 to 122 ).℃℉ Operating Humidity Less than 80% RH. Power Supply DC 1.5 V battery ( UM4, AAA ) x 6 PCs,
or equivalent. Power Approx. DC 12 mA. Consumption Dimension 245 x 68 x 41 mm
( 9.6 x 2.7 x 1.6 inch). Weight 358 g/0.79 LB (including battery).
Accessory Included Instruction Manual ............... 1 PC.
4
Optional
94 dB Sound Calibrator :
Accessories Model : SC-941. SC-942.
Sound wind shield ball
Model : SB-01
RS232 cable ( isolated RS232 cable ) :
Model : UPCB-02.
USB cable
Model : USB-01
Application windows software :
Model : SW-U801-WIN.
Type K Temperature probe :
Model : TP-01 TP-02A, TP-03. TP-04
2-4 Electrical specifications for optional probe EM-900
P
Anemometer
A
. Air velocity
Measure-Range Resolu- Accuracy ment tion
m/S 0.4 - 25.0 m/s 0.1 m/s ± (2% + 0.2 m/s) km/h 1.4 - 90.0 km/h 0.1 km/h ± (2% + 0.8 km/h) mph 0.9 - 55.9 mile/h 0.1 mile/h ± (2% + 0.4 mile/h) knot 0.8 - 48.6 knots 0.1 knots ± (2% + 0.4 knots) FPM 80 - 4930 ft/min 1 ft/min ± (2%+40 ft/min.)
Note:
m/S - meters per second km/h - kilometers per hour FPM - feet per minute knot - nautical miles per hour mph - miles per hour (international knot)
B. Temperature
Measuring Range 0 to 50 /32 to 122 ℃℃℉ ℉ Resolution 0.1 /0.1 ℃℉ Accuracy ± 0.8 /1.5 ℃℉
5
Loading...
+ 17 hidden pages