This addendum applies to the GRAFIK Eye QS Wireless models listed
below, and their associated components.
QSGRJ-3P
QSGRJ-4P
QSGRJ-6P
QSGRK-3PCE
QSGRK-4PCE
QSGRK-6PCE
QSGRJ-6E
QSGRJ-8E
QSGRJ-16E
Contents
Associating GRAFIK Eye QS Wireless Control Units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Associating Wireless Occupancy Sensors and GRAFIK Eye QS Wireless Control Units . . . . . . . . . . . . . . . . . . . . 3
Associating Sivoia® QS Wireless Shades/Drapes and GRAFIK Eye QS Wireless Control Units . . . . . . . . . . . . . . . . 4
Associating PicoTM Wireless Controls and GRAFIK Eye QS Wireless Control Units: Zone Control. . . . . . . . . . . . . . 5
Associating PicoTM Wireless Controls and GRAFIK Eye QS Wireless Control Units: Scene Control. . . . . . . . . . . . . 6
Wireless Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Wireless System Programming
GRAFIK Eye® QS Wireless System Programming 2
GRAFIK Eye QS A
“Talks” to GRAFIK Eye QS B; scene
activation and master (raise/lower)
button presses activated on unit A are
replicated on unit B.
GRAFIK Eye QS B
“Listens” to GRAFIK Eye QS A; unit B
replicates scene activations and master
(raise/lower) button presses on unit A.
When there is more than one GRAFIK Eye QS control unit in a
wireless system, it is often convenient to associate them so that
scene activations and master (raise/lower) button presses carry
over to other associated GRAFIK Eye QS control units.
To associate two GRAFIK Eye QS control units:
1. Begin with the GRAFIK Eye QS control unit that will “talk” (button
presses will be replicated on the other control unit; in the drawing
below this is GRAFIK Eye QS A). Press and hold the top and
bottom scene buttons until the LEDs flash (about
3 seconds).
2. Continue with the GRAFIK Eye QS control unit that will “listen”
(replicate button presses on the other control unit; in the drawing
below this is GRAFIK Eye QS B). Press and hold the top scene
button until the LEDs flash (about 3 seconds).
3. Return to the GRAFIK Eye QS control unit that will “talk” (A). Press
and hold the top and bottom scene buttons until the LEDs stop
flashing (about 3 seconds).
4. It is often desired to repeat the process in reverse so that GRAFIK
Eye QS B talks to GRAFIK Eye QS A.
To disassociate two wireless GRAFIK Eye QS control units:
Simply repeat the association steps, in the same order; press and
hold the bottom scene button on B to disassociate.
Note: The wireless signal has a range of 30 feet (10 m) through
standard construction.
Associating GRAFIK Eye QS Wireless Control Units
On the unit that will “talk”,
press and hold the top and
bottom scene buttons for
3 seconds to begin or end
association or disassociation
with the unit that will “listen”.
On the unit that will “listen”,
press and hold the top scene
button for 3 seconds to
associate, or press and hold
the bottom scene button for 3
seconds to disassociate with
the unit that will “talk”.
Associate
OR
Disassociate
Wireless System Programming
GRAFIK Eye® QS Wireless System Programming 3
Wireless Occupancy Sensor
“Talks” to GRAFIK Eye QS control
unit, activating scenes on the
GRAFIK Eye QS.
Lutron’s wireless Radio Powr SavrTM occupancy and vacancy sensors can
be associated with the GRAFIK Eye QS Wireless to activate scenes when
occupancy or vacancy is detected.
To associate wireless occupancy sensors and
GRAFIK Eye QS control units:
1. Press and hold the “Lights On” and “Lights Off” buttons on the front of
the occupancy/vacancy sensor simultaneously until the lens starts flashing
(about 3 seconds).
2. Press and hold the top scene button of the GRAFIK Eye QS Wireless
control unit until the LEDs flash (about 3 seconds).
3. Return to the occupancy sensor. Press and hold the “Lights On” and
“Lights Off” buttons simultaneously until the lens stops flashing (about 3
seconds).
To disassociate wireless occupancy sensors and
GRAFIK Eye QS control units:
Simply repeat the association steps, in the same order; press and hold the
bottom scene button on the GRAFIK Eye QS to disassociate.
Note: The wireless signal has a range of 30 feet (10 m) through standard
construction.
Associating Wireless Occupancy Sensors and GRAFIK Eye QS Wireless Control Units
On the wireless occupancy
sensor, press and hold the
“Lights On” and “Lights Off”
buttons for 3 seconds to begin or
end association or disassociation
with the GRAFIK Eye QS control
unit.
Note: Pressing the “Lights On”
button initiates the “occupied”
scene programmed on the
GRAFIK Eye QS control unit.
Pressing the “Lights Off” button
initiates the “unoccupied” scene
programmed on the GRAFIK Eye
QS control unit.
Before the GRAFIK Eye QS is
programmed, the “Lights On”
button may not produce an
action. Refer to the Installation
manual for the GRAFIK Eye QS
to program desired scenes.
On the GRAFIK Eye QS
control unit, press and hold
the top scene button for 3
seconds to associate, or
press and hold the bottom
scene button for 3 seconds
to disassociate with the
occupancy sensor.
Associate
OR
Disassociate
GRAFIK Eye QS Control Unit
“Listens” to wireless occupancy sensor,
so that the occupancy sensor activates
scenes on the GRAFIK Eye QS.
Lens