Lutron Electronics N-600, N-1000, N-1500, N-2000, Nova N-600 Installation Instructions Manual

...
Installation Instructions
Please Leave for Occupant
P/N 030-1013
Incandescent Dimmers
N-600, N-1000, N-1500, N-2000
120 V~ 60 Hz
Table Of Contents
Package Contents ................................................. 1
Important Notes ..................................................... 1
Single Unit Installation .......................................... 1
Multigang Installation-
No side Sections Removed ............................ 2
Multigang Installation-
Side Section Removed ................................... 3
Installation Assistance .......................................... 4
Package Contents:
Slider
Mounting
Screws
Wire
Control
Faceplate
Connectors
Important Notes Please Read Before Installation
Lamp Type: Use this product with incandescent
and quartz lamps only--120 V~ 60 Hz. Do not connect to low-voltage lamps or any appliance.
Caution: To avoid overheating and possible damage to other equipment, do not install this product to control receptacles, fl uorescent lighting fi xtures, motor-operated appliances, or transformer supplied appliances.
Short Circuit Check: Check new installation for
short circuits prior to installation of dimmer by using a single pole switch and connecting the appropriate terminals to the hot wire and the lamp with power OFF. Turn power on. If lights do not work, or breaker trips, a short is present. Correct the wiring and check circuit again. Install dimmer only when short is no longer present.
Wire Connectors: Wire connectors provided can be used to join one 10, 12, 14, 16, or 18 AWG (4, 2.5, 1.5, 1, or 0.75 mm2) wire with one or two 12 or 14 AWG (2.5 or 1.5 mm2) wires. Use them with copper wire only.
Switchbox and Location: A single-gang switchbox, 3 in high x 2 in wide x 2 1⁄2 in deep (76 x 5 x 63 mm), will service all individual Nova dimmers. These dimmers are designed to operate in ambient temperatures from 32 °F to 104 °F (0 °C to 40 °C). Allow a minimum space in the wall of 41/2 in (114 mm) above and below the dimmers for proper heat dissipation.
Multigang Installations: A multigang faceplate is available to simplify and improve the appearance of your installation. A multigang mounting frame is provided with each standard multigang faceplate to ensure proper alignment of the dimmers, easy application of the faceplate, and a fl at surface for the installation. Refer to instruction sheet supplied with multigang faceplates.
Single Unit Installation
1. TURN POWER OFF. Control must only be
installed when power is turned OFF. Remove fuse or turn circuit breaker OFF. Damage to product caused by wiring with power on voids warranty.
2. Remove faceplate from dimmer to access
mounting holes. Pull out at top and bottom edges, plate will snap off.
3. Strip insulation from dimmer wires and from
wires in switchbox as follows:
• 1/2 in for 10, 12 and 14 AWG (12 mm for 4, 2.5 and 1.5 mm2) supply wire.
• 5/8 in for 16 and 18 AWG (15 mm for 1 and
0.75 mm2) control wire. 1/2 in or 5/8 in
(12 mm or 15 mm)
4. Using the wire connectors provided:
• Connect the green or bare ground wire on the dimmer to the green or bare copper ground wire in the wallbox. Note: When “no grounding means” exists within the wallbox, then the NEC® 2008, Article 404.9 allows a switch without a grounding connection to be installed as a replacement, as long as a plastic, noncombustible wallplate is used. For this type of installation, cap or remove the green ground wire from the switch and use an appropriate wallplate such as a Nova® series wallplate by Lutron.
• Connect one of the black wires on the dimmer to either one of the wires removed from the switch. Be sure no bare wire is exposed.
• Connect the other black wire on the dimmer to the remaining wire removed from the switch. Be
sure no bare wire is exposed.
Live
120 V~
120 V~
60 Hz
60 Hz
Black
Green or Bare
Ground
Black
Light
Neutral
Lutron and Nova are registered trademarks of Lutron Electronics Co., Inc. © 2008 Lutron Electronics Co., Inc.
1
5. Push wires into switchbox, allowing room for
dimmer backbox to be inserted.
Multigang Installation-
No Side Sections Removed (No Derating Required)
6. Mount dimmer to switchbox using the 2 provided
screws in the center mounting holes (offset mounting holes are for multigang installation). Unit must be mounted vertically.
Ground (Green or Bare)
In multigang installations, several dimmers or controls are grouped horizontally in one ganging switchbox or in a series of connected switchboxes. Multigang faceplates are available to simplify and improve the appearance of this installation. A multigang mounting frame is provided with standard multigang faceplates which ensures proper alignment of dimmers, easy application of the faceplate, and a fl at surface for the installation. Refer to instruction sheet (supplied with multigang faceplate) when using these components. Installation of dimmers without removing side sections allows operation at full capacity (no derating). Follow instructions below. For retrofi t installations side sections can be removed to fi t existing switchboxes. This requires derating and is described in "Multigang Installation - Side Sections Removed" on page 3.
1. Determine the number of switchboxes necessary
by using the Switchbox Requirement Chart (Table A). When ganging any combination of small dimmers (N-600, N-1000) and large dimmers (N-1500, N-2000), keep all small dimmerstogether at one end of the gang and all large dimmers together at the other end of the gang.
Table A. Switchbox Requirement Chart
No Side Sections Removed
Offset Mounting Holes
Center Mounting Holes
7. Snap faceplate on dimmer.
Ta bs
Faceplate
Press plate Until Tabs Snap In
8. Turn power ON. Push slider up to increase light
and down to decrease light. Full "down" position will turn light off.
Number of Small Controls
0 1 2 3 4 5 6
Number of Switchboxes Required
0 0 1 1+1* 4 4+1* 7 7+1* Number 1 1 3 5 6 8 9 11 of Large 2 4 6 7 9 10 12 13 Controls 3 6 8 10 11 13 14 16 4 9 11 12 14 15 17 18
*See item #2
2. When ganging an even number of small
controls use gangable switchboxes with tapped ears. Do not use plaster rings or gangbox covers. One switchbox in addition to the total number of controls is required in order to provide space for faceplates (e.g. 4 dimmers require 5 switchboxes). Place additional switchboxes 3/4 in (19 mm) apart from other switchbox(es) to provide space for faceplate(s).
Four-gang wallbox
3/4 in (19 mm) space (use chase nipple or Lutron P/N “PLUS-ADPTR-3.5”)
Single-gang Wallbox
2
Loading...
+ 2 hidden pages