Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA18036-1299, U.S.A. Made and printed in the U.S.A. 11/10 P/N 033-214 Rev. A
English
Canopy Module
CM-FQ1: 120 V~ 60 Hz
1.0 A fan
MA-FQ4M: 120 V~ 60 Hz
4.0A(up to 4 CM-FQ1)
Accessory Control
MA-AFQ4: 120 V~ 60 Hz
4.0 A
Important Notes
Please read before installing.
1. Caution: To avoid overheating and possible damage to other equipment, do not use to control receptacles, lighting xtures, transformer-supplied appliances, solid state fan motors, or
exhaust fans. For exhaust fans use Lutron fully variable fan speed controls.
2. Install in accordance with all national and local electrical codes.
3. When no “grounding means” exist within the wallbox then the NEC®2002, Ar ticle 404-9 allows
a wall control without a grounding connection to be installed as a replacement, as long as a plastic, noncombustible wallplate is used. For this type of installation, cap or remove the green ground wire on the wall control and use an appropriate wallplate such as Lutron’s Claro®or Satin ColorsTM series wallplates.
4. The Maestro®fan speed control system consists of a Wall Control, one to four Canopy Modules, and up to two Accessory Controls.All must be installed correctly before attempting to control the fans.Do not attempt to mix Lutron controls with those from other manufacturers, or mix Lutron controls not labeled for use together.
5. This system is not compatible with fans having a control system built into the motor.
6. Do not paint Wall Control, Canopy Module, or Accessory Control.
7. MaestroControls are not compatible with standard 3-way/4-way switches.
8. Accessory Controls (MA-AFQ4) cannot be used individually and must be used in conjunction
with a MaestroWall Control (MA-FQ4M) in a 3-way/4-way application.
9. In any 3-way/4-way circuit use only one Wall Control (MA-FQ4M) with up to 2 Accessory Controls (MA-AFQ4).
10. Oper ate between 32°F (0 °C) and 104 °F (40 °C) room temperature. For indoor use only.
11. W all Control and Accessory Controls may feel warm to the touch during nor mal operation.
12. Recommended wallbox depth is 2.5 in (64 mm) minimum.
13. Clean controls with a soft damp cloth only. Do not use any chemical cleaners.
14. This system cannot be used to change the direction of the f an.To change the fan direction,
stop the fan, and then change the position of the switch located on the body of the fan.
15. Do not use pull chains to operate fan(s) after installing this system.
16. Each Canopy Module must be installed within a fan canopy enclosure.
17. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Quiet Fan Speed Control Multi-Location System
®
Fan Speed Control
Warning: For use with one to four ceiling paddle fans only. Do not use with an
exhaust fan.
One to four ceiling fans only No exhaust fans
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encour aged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer
or an experienced radio/TV technician for help.
P/N 033-214
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre­paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES,AND THE IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED TO ONE YEAR FROM PURCHASE.THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR REINST ALLA TION, OR DAMAGE RESULTING FROM MISUSE,ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION.THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES.LUTRON’S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION,DELIVERY,OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE UNIT.
This
warranty gives you specic legal rights, and you may have other rights which vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitation on how long an implied warranty may last, so the above limitations may not apply to you. Lutron, Claro, and Maestro are registered trademarks and FASS and Satin Colors are trademarks of Lutron Electronics Co., Inc. NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts. © 2010 Lutron Electronics Co., Inc.
Operation
Tap Button
Tap once when fan is off -Fan
speed increases to preset level.
Tap once when fan is on -Fan
speed slows to off.
Tap twice quickly -Fan speed
increases to full speed.
LEDs
Indicate exact fan speed
LEDs will change with each press
(LEDs not available on Accessory Controls)
Press to increase fan speed Press to decrease fan speed
FASSTM - Front
Accessible
Service Switch
Multigang Installations
When installing more than one control in the same wallbox, it may be necessary to remove all inner side sections prior to wiring (see below). Using pliers, bend side sections up and down until they break off. Repeat for each side section to be removed. Note: Product does not require derating
when side sections are removed.
Breaking Side Sections
?
Technical Assistance
If you have questions concerning the installation or operation of this product, call the Lutron Technical Support Center. Please provide exact model number when calling.
U.S.A. and Canada (24 hrs/7 days): +1.800.523.9466
Other countries 8am – 8pm ET: +1.610.282.3800 México +1.888.235.2910
Fax +1.610.282.1243
http://www.lutron.com
Inside sections are removed from each
control
Side sections are
removed from both
sides of middle control
Do not remove
outside
sections.
Reference Wiring Diagram
Canopy Module
First Fan / Canopy Module
Live
120V~
60Hz
Neutral
White
Black
Yellow (Fan)
Lutron Technical Support Center
1.800.523.9466 24 hrs / 7 days www.lutron.com
ON
OFF
ON
OFF
ON
OFF
Turn OFF power.
Turn power OFF at circuit breaker (or remove fuse).
Canopy Module Installation
Set fan speed.
Set fan(s) to highest speed using pull chains.
Install fan(s).
Install fan(s) according to manufacturer's instructions and check for proper operation.
3
2
1
Important Wiring Information
When making wire connections, follow the recommended strip lengths and combinations for the supplied wire connectors (see wire connector bag).Note: All wire connectors provided are suitable for copper wire only.For aluminum wire, consult an electrician.
Twist wire connector
tight.
Connect Canopy Module(s).
If you have questions about wiring, call the Lutron Technical Support Center at +1.800.523.9466.
Fan
Canopy Module
Switched Live
Black
White
Yellow
Neutral
Canopy Module Wire:
White
Black
Yellow
Connects to:
Neutral wires in the junction box and to fan
Switched Live wire(s) from Wall Control and to additional fan(s)
Fan
5
To junction box
To fixture
Wiring the Canopy Module (CM-FQ1):
Use wire connectors to join wires as indicated below and in the wiring diagram, and to cap any unused wires.
Troubleshooting
Symptom
Fan does not turn ON or no LEDs turn ON.
LEDs on Wall Control cycle rapidly and bottom LED is ON.
LEDs on Wall Control cycle rapidly and second lowest LED is ON.
Fan vibrates or wobbles.
Fan speeds too slow.
Wall Control LEDs respond as expected but fan does not respond properly.
Possible Cause
Front Accessible Service Switch (FASS) on control is pulled out to the OFF position.
Manual switch on fan is off (ex: pull chain).
Breaker is OFF or tr ipped (or fuse blown).
Fan direction switch is between forward and
reverse.
Wiring error, call Lutron Technical Support Center at +1.800.523.9466.
Unit is not activated properly.Activate system as described in Step 15.
Wiring error, call Lutron Technical Support Center at +1.800.523.9466.
Communication error.Check wiring;if error continues, call Lutron Technical Support Center at +1.800.523.9466.
Fan blades not properly balanced.See fan manufacturer's instructions.
Fan pull chain not set to high.
Fan pull chain not set to high.
Wiring error, call Lutron Technical Support
Center at +1.800
.523.9466.
Switched Live
Fan Neutral
Typical Wire Colors
Black White
Disconnect fan.
Remove canopy enclosure from ceiling fan mounting bracket.
Leave any green ground wires connected as directed in fan manufacturer's instructions.
Disconnect fan from remaining wiring in the ceiling.
4
To junction box To junction box
Flush Mount BracketDown Rod Bracket
Mounting bracket
Canopy enclosure
Switched Live to additional fans
Up to 3
Additional
Fans / Canopy
Modules
(up to 4 total)
Wall
Control
Wallbox
Green
Black
Brass
Ground
Brass
See Step 12 for two- and three-location control wiring.
Note: Up to four ceiling fans can be controlled on one circuit.
Follow steps 4–7 for each fan.
Wire Connectors:
Use to join 1.5 or 2.5 mm² (14 or 12 AWG) ground wire to 0.75 mm²
(18 AWG) Wall Control ground wire, and to join 0.75 mm² (18 AWG) Canopy Module wire to 2.5, 1.5, 1.0 or 0.75 mm²
(12, 14, 16 or 18 AWG) wire.
Lutron Technical Support Center 1.800.523.9466 24 hrs / 7 days www.lutron.com
Cable tie
6b - Flush Mount Bracket
Do not install Canopy Module in ceiling.
Attach Canopy Module to bracket with a cable tie.
Ensure cable tie does not come in contact with moving motor parts.
Install cable tie through notches on Canopy Module. Pull tight and clip excess.
To junction box
6a - Down Rod Bracket
Do not install Canopy Module in ceiling.
Slide Canopy Module into the ceiling fan mounting bracket.
To junction box
Remove original wallplate and switch.
Remove the wallplate and switch mounting screws.
Carefully remove switches from wall (do not remove wires).
Attach canopy.
Control Installation
7
8
7b - Flush Mount Bracket
Check all wire connections.
Tuck the wires into the junction box and/or bracket.
Ensure wires and/or wire connectors do not come in contact with moving motor parts.
Attach the canopy enclosure to the fan mounting bracket, taking care not to pinch any wires.
To junction box
To junction box
7a - Down Rod Bracket
Check all wire connections.
Tuck the wires into the junction box and/or canopy enclosure.
Attach the canopy enclosure to the fan mounting bracket, taking care not to pinch any wires.
Danger: Verify power to each switch is OFF before proceeding.
Important Note:
Your wall switch may have two wires attached to the same screw (see illustrations below for examples).Tape these two wires together before disconnecting.When wiring, connect wires to new Controls the same way they were connected to the switch.
Identify switch wires.
10
One wire in the push-in terminal and one to the screw.
One continuous wire to the screw.
Disconnect switch wires.
Connect Control(s).
For installations involving more than one control in a wallbox, refer to Multigang Installations before beginning.
Only one Wall Control (MA-FQ4M) can be used with up to 2 Accessory Controls (MA-AFQ4).
Ground
Green wire
Black screw
Wall Control
Brass screws
Important Wiring Information
Trim or strip wallbox wires to the length indicated by the strip gauge on the back of the control
OR
12
11
Screw Terminals: Turn screws to loosen.
Push-in Terminals: Insert screwdriver. Pull wire out.
Looped Wire: Turn screw to loosen.
Wiring the Wall Control (MA-FQ4M):
Connect either of the wires removed from the switch
to the blackscrew terminal on the Wall Control.
Connect the remaining wire removed from the switch
to one of the brass screw terminals on the Wall Control.
Tighten the remaining brassscrew terminal on the
Wall Control. It is not used in a single-pole circuit.
Use wire connectors to connect the green ground wire on the Wall Control to the bare copperor green ground wire in the wallbox (see Important Note 3), and to cap any unused wires.
Mount Control(s) to wallbox.
Form wires carefully into the wallbox, mount and align the Control(s).
Install wallplate(s).
Caution: Do not overtighten mounting screws.
13
Align control and tighten screws.
Start screws.
Insert Canopy Module.
6
15
16
ON
OFF
ON
OFF
ON
OFF
Turn ON power.
Do not turn on power until Wall Control, Accessory Control(s) and Canopy Module(s) have been installed and wired.
Turn power ON at circuit breaker (or replace fuse).
Recommended - Disconnect pull chains.
Disconnect pull chain extensions to prevent fan speed from being adjusted at the fan(s).
Activate system.
Pull out the Front Accessible Service Switch (FASS ) at the bottom of the Wall Control, wait 10 seconds, then push it back in.
The LEDs will cycle for up to 30 seconds.
If installing more than one Wall Control/Canopy Module system,
activate one at a time with FASS pushed in on all other systems.
Accessory Controls do not require activation.
14
Identify the circuit type.
One switch controlling the fan(s).
This switch will be a single-pole.The switch will have insulated wires connected to two screws of the same color plus a green ground screw.
Ground (Bare Copper or Green Wire)
Two switches controlling the fan(s).
Both switches will be 3-way.Each switch will have insulated wires connected to three screws plus a green ground screw.One of these wires is connected to a screw of a different color (not green) or labeled COMMON. TAG this wire on both switches to identify when wiring.
Tagged wire
Different colored screw (Common)
Ground (Bare Copper or Green Wire)
Three switches controlling the fan(s).
Two switches will be 3-way and one will be a 4-way.TAG the two 3-way switches as in the Two-Location diagram above.The 4-way switch will have insulated wires connected to four screws plus a green ground screw.TAG two insulated wires which are connected to same colored screws.
Tagged wires
Note:Screw placement may be different on your switch.
Same colored screw (or marked IN or OUT)
Ground (Bare Copper or Green Wire)
9c - Three-Location control
9b - Two-Location control
9a - Single-Location control
12a - Single-Location control
12b - Two-Location control
Live
120V~ 60Hz
Neutral
Canopy Module and Fan Fixture
Green
Ground
Wallbox
Wall Control
Reference Wiring Diagram
One location will be replaced with a Wall Control (MA-FQ4M) and the other with an Accessory Control (MA-AFQ4).
Ground
Tag
Green wire
Wiring the Wall Control and Accessory Control:
Connect the tagged wire removed from the switch to
the blackscrew terminal on the Control.
Connect one of the remaining wires removed from the
switch to one of the brassscrew terminals on the Control.
Connect the remaining wire removed from the switch
to the remaining brass screw terminal on the Control.
Use wire connectors to connect the green ground wire on the Control to the bare copper or green ground wire in the wallbox (see Important Note 3), and to cap any unused wires.
Live
120V~ 60Hz
Black
Green
Green
Ground
Ground
Wallbox
Wall Control or
Accessory Control
Wall Control or
Accessory Control
Wallbox
Reference Wiring Diagram
12c - Three-Location control
One location will be replaced with a Wall Control (MA-FQ4M) and the other two with Accessory Controls (MA-AFQ4).
Replace the 4-way switch Note: 4-way switch may be replaced with either a Wall
Control or an Accessory Control
Connect both of the tagged wires removed from the
4-way switch to the blackscrew terminal on the Control (one wire to the screw and the other to the push-in terminal).
Connect one of the remaining wires removed from the
switch to one of the brassscrew terminals on the Control.
Connect the remaining wire removed from the switch
to the remaining brass screw terminal on the Control.
Use wire connectors to connect the green ground wire on the Control to the bare copper or green ground wire in the wallbox (see Important Note 3), and
to cap any unused wires.
Replace the two 3-way switches
Follow Step 12b - Two-Location control.
Ground
Tagged wires
Green wire
Live
120V~ 60Hz
Brass
Brass
Black
Black
Green
Green
Ground
Ground
Wallbox
Wall Control or
Accessory Control
Wall Control or
Accessory Control
Wall Control or
Accessory Control
Wallbox
Green
Ground
Wallbox
Reference Wiring Diagram
9
Wall Control and
Accessory Control
Wall Control or
Accessory Control
Brass
Br ssarBssa
Black
Brass
Brass
Brass
Black
Black
Brass
Brass
Brass Black
Brass
Black screw
Brass screws
Black screw
Brass screws
Notch
Note:Screw placement may be different on your switch.
Warning: Fan(s) will return to
full speed when power is restored.Clean up any tools or ladders near the fan(s) rst.
Canopy Module and Fan Fixture
Up to 4 Canopy Modules and Fans
Neutral
Canopy Module and Fan Fixture
Canopy Module and Fan Fixture
Up to 4 Canopy Modules and Fans
Neutral
Canopy Module and Fan Fixture
Canopy Module and Fan Fixture
Up to 4 Canopy Modules and Fans
Push-in Terminals:Insert wires fully. NOTE: Push-in terminals are for use with 14 AWG (1.5 mm²) solid copper wire only. DO NOT use stranded or twisted wire.
Screw Terminals: Tighten securely. Screw terminals are for use with 12 or 14 AWG (2.5 or 1.5 mm²) solid copper wire only. DO NOT use stranded or twisted wire.