Lutron Electronics LM-8010 Operation Manual

CMM, CFM
Anemometer, Hygrometer Light Meter, Thermometer
Model : LM-8010
Your purchase of this METER marks a step forward for you into the field of precision measurement. Althou
g
h this METER is a complex and delicate instrument, its durable structure will allow many years of use if proper operatin
g
techniques are developed. Please read the followin
g
instructions carefully and always keep this manual within easy reach.
OPERATION MANUAL
TABLE OF CONTENTS
1. FEATURES................................................................1
2. SPECIFICATIONS......................................................2
3. FRONT PANEL DESCRIPTION....................................
.
5
3-1 ON/ESC Button...................................................
.
5
3-2 Hold Button........................................................
.
5
3-3 REC/Enter Button.................................................5
3-4 Unit/Zero/ ( CFM/CMM ) Button........................5
3-5 / / , Lux/Ft-cd, Area-Set Button....................℃℉▲ 5
3-6 Function/ Button.............................................. 5
3-7 Anemometer Sensor............................................5
3-8 Thermocouple Input Socket.................................
.
5
3-9 Humidity Sensor..................................................5
3-10 Li
g
ht Sensor......................................................5
3-11 LCD display.......................................................5
3-12 Battery Compartment / Cover.............................5
3-13 Wristlet.............................................................5
4. MEASURING PROCEDURES........................................6
4-1 AIR VELOCITY MEASUREMENT............................
.
6 4-2 TEMPERATURE MEASUREMENT
(Thermocouple)..................................................6
4-3 RELATIVE HUMIDITY MEASUREMENT...................7
4-4 LIGHT MEASUREMENT........................................
.
7
4-5 AIR FLOW (CFM. CMM) MEASUREMENT................7
5. OTHER FUNCTIONS..................................................9
6. BATTERY REPLACEMENT...........................................10
7. OPTIONAL THERMOCOUPLE PROBE AND
OTHER ACCESSORIES.............................................
.
11
1. FEATURES
* 5 in 1 professional measuring instrument: Anemometer,
Air flow, Hygrometer, Thermometer, and Light meter.
* Tiny bone shape with lightweight and small size case design
are suitable for handling with one hand.
* Wristlet design provides extra protection to the instrument
especially for user one hand operation.
* Low-friction ball bearing mounted wheel design provides
high accuracy at high and low air velocity.
* Exclusive photo diode and color correction filter light sensor,
spectrum meets C.I.E. photopic.
* High precision thin-film capacitance humidity sensor with
fast response to the humidity changes.
* Standard type K (NiCr-NiAl) thermocouple input jack
suitable for all kinds of type K probe.
* Built- in microprocessor circuit assures excellent
performance and accuracy.
* Concise and compact buttons arrangement, easy operation. * Memorize the maximum and minimum value with recall. * / selectable by pressing button on the front panel.℃℉ * Lux/Feet-candle selectable by pressing button on the front
panel.
* Air velocity measuring units selectable by pressing button on
the front panel for five kinds of units.
* Air flow ( CFM. CMM ) measurement can set the desired area
dimension.
* Multi channel display for relative humidity and temperature
measured values or air velocity and temperature measured values at the same time.
* Zero button design makes light meter calibration. * Hold function to freeze the current reading value.
1
2. SPECIFICATIONS
2-1 General Specifications
Display 8 mm LCD display Measurement Anemometer, Humidity, Temperature,
Light, Air flow ( CFM/CMM ). Operating Max. 80% RH. Humidity Operating 0 to 50° C (32 to 122° F) Temperature Over Input Indication of "- - - - " Display Power Supply 006P DC 9V battery (Heavy duty type) Power Approx. DC 6.2 mA Consumption Weight 160g (battery included) Dimension
HWD :
156x60x33 mm
6.14x2.36x1.29 inch Standard Instruction Manual Accessory Optional Carrying case. Accessories Temperature probe ( Please refer to
page 9 ).
2
2-2 Electrical Specification ( 23 ±5 )
Measurement Range Resolution
Air velocity ft/min 80 to 5,910 ft/min 1 ft/min
m/s 0.4 to 30.0 m/s 0.1 m/s km/h 1.4 to 108.0 km/h 0.1 km/h MPH 0.9 to 67.0 mile/h 0.1 MPH knots 0.8 to 58.3 knots 0.1 knots Temperature 32 to 122 0.1 ℉ ( thermister) 0 to 50 0.1 ℃
Measurement Range Resolution
Air flow CMM 54,000 CMM 0.001 to 1
cube meter/min CMM CFM 1,908,400 CFM 0.001 to 100 cube feet/min CFM
Measurement Range Resolution
Humidity % RH 10 to 95 %RH 0.1 %RH
Temperature 32 to 122 0.1 ℉ ( thermister) 0 to 50 0.1 ℃
Measurement Range Resolution
Light Lux 0 to 2,200 Lux 1 Lux
1,800 to 20,000 Lux10 Lux
* auto range
Ft-cd 0 to 204.0 Ft-cd 0.1 Ft-cd
170 to 1,860 Ft-cd 1 Ft-cd
Measurement Range Resolution
Temperature ( Type K ) -148 to 2,372 0.1 ℉
-100 to 1,300 0.1
3
Measurement Range Accuracy
Air velocity 80 to 5,910 ft/min
0.4 to 30.0 m/s 20 m/s : ± 3% F.S.
1.4 to 108.0 km/h > 20 m/s : ± 4% F.S.
0.9 to 67.0 mile/h
0.8 to 58.3 knots 32 to 122 ±2.5 0 to 50 ±1.2
Remark : ft/min : feet per minute MPH : miles per hour m/s : meters per second knots : nautical miles per hour km/h : kilometers per hour Ft-cd : feet candle
Measurement Range Accuracy
Humidity 10 to 95 %RH
< 70% RH :
±4 %RH
70% RH :
: ± ( 4%rdg + 1.2 %RH ) 32 to 122 ±2.5 0 to 50 ±1.2
Measurement Range Accureacy
Light 0 to 20,000 Lux ± 5% rdg ± 8 dgt
0 to 1,860 Ft-cd
Measurement Range Accuracy
Temperature -148 to 2,372 ± (1% rdg + 2 ) ( Type K ) -100 to 1,300 ± (1% rdg + 1 )
Measurement Area setting
CMM 0.001 to 30.000 meter square CFM 0.01 to 322.92 feet square
4
3. FRONT PANEL DESCRIPTION
Fig. 1
3-1 ON/ESC Button 3-6 Function/ Button 3-2 Hold Button 3-7 Anemometer Sensor 3-3 REC/Enter Button 3-8 Thermocouple Input Socket
3-4 Unit/Zero/
3-9 Humidity Sensor ( CFM/CMM ) Button. 3-10 Light Sensor 3-5 / /℃℉▲ 3-11 LCD display Lux/Ft-cd 3-12 Battery Compartment / Cover Area-set Button 3-13 Wristlet
5
4. MEASURING PROCEDURE
4-1 Air Velocity Measurement
1) Power on the instrument by pressing the " ON Button "
( 3-1, Fig. 1 ).
2) Select the Anemometer function by pressing " Function
Button " ( 3-6, Fig. 1 ).
3) Press the " Unit/Zero Button " ( 3-4, Fig. 1 ) to select
unit that you want and then face the " Anemometer Sensor " ( 3-7, Fig. 1 ) to the source of wind.
4) Allow time for the reading to become stable and note the
value indicated. From a practical point of view the velocity may fluctuate.
4-2 Temperature Measurement ( Thermocouple )
1) Power on the instrument by pressing the " ON Button "
( 3-1, Fig. 1 )..
2) Plug a type K thermocouple probe in the " Thermocouple
Input Socket " ( 3-8, Fig. 1 ).
3) Select the Temperature function by pressing " Function
Button " ( 3-6, Fig. 1 )
4) Press the " / Button " ( 3-5, Fig. 1 ) to select or unit.℃℉ 5 Contact the Thermocouple Sensor Head with measuring
object and the reading value will be displayed on the LCD display.
Measuring Consideration of Temperature Measurement ( Thermocouple )
* Please make sure the polarity is correct when you plug a
thermocouple probe in the Temp. input socket.
6
* The temperature difference between thermocouple
probe and thermometer will cause an inaccurate measuring result. Therefore, for the best measuring and accuracy performance, whenever change a probe or plug a new probe, thermal equivalent between probe plug and meter's input socket is a necessary condition. Thermal equivalent procedure may take few minutes and apply only when the probe has been exposed to an ambient temperature different from the meter.
4-3 Humidity & Ambient Temperature Measurement
1) Power on the instrument by pressing the " ON Button "
(3-1, Fig. 1).
2) Select the Relative Humidity function by pressing
" Function Button " ( 3-6, Fig. 1 ).
3) At the mean time the reading value of relative humidity
and temperature will be displayed on the LCD display.
4) When the meter is applied in a new environment, a few
minutes are required to reach a stable condition.
4-4 Light Measurement
1) Power on the instrument by pressing the " ON Button "
( 3-1, Fig. 1 ).
2) Select the Light Measurement function by pressing the
" Function Button " ( 3-6, Fig. 1 ) until the light value is displayed. The light display digits are oriented 180° from the other function displays for easy exposure and output reading of the light sensor.
3) Press the " Lux/Ft-cd Button " ( 3-5, Fig. 1 ) to
select measuring unit " Lux " or " Ft-cd ".
7
Zero Offset Adjustment of Light Function :
* For best results zero the light sensor prior to use in a
dark environment. Placing the light sensor end of the meter under a desktop or flat surface so as to block any light can accomplish this. Then press the " Unit/Zero Button " ( 3-4, fig. 1 ) to set the meter indication to zero.
* Zero point can drift due to environment temperature
and battery power change as well as for other reasons. It is recommended that the zero be checked frequently using the above procedure.
* Zero adjustment only can be executed if the lmeasurement
Light value 20 Lux.
4-5 AIR FLOW (CFM. CMM) MEASUREMENT
1) Power on the instrument by pressing the " ON
Button " (3-1, Fig. 1).
2) Select the Air Flow function by pressing
" Function Button " ( 3-6, Fig. 1 ) until the display show unit of CMM or CMM.
* Air flow unit " CFM " or " CMM " can be select by
pressing the " CFM/CMM Button " ( 3-4, Fig. 1 )
* Area size can be set by by pressing the " Area-Set
Button " ( 3-5, Fig. 1 ), then use the
Button ( 3-5, Fig. 1 ) Button ( 3-6, Fig. 1 )
Button ( 3-4, Fig. 1 )
to select the desired area size.
8
* For the CMM measurement, the area size is " meter square ",
the lower display will show " m-2 ". For the CMM, the area setting size is from 0.001 to 30.000 meter square.
* For the CFM measurement, the area size is " feet square ",
the lower display will show " F-2 ". For the CMM, the area setting size is from 0.01 to 322.92 feet square.
4) Use the hand to hold the meter,
face the " Anemometer Sensor " ( 3-7, Fig. 1 ) to the measured wind. In the same time the air flow value ( CMM, CFM ) will show on the LCD display.
5. OTHER FUNCTIONS
5-1 Hold Function
Whenever press the " Hold Button (3-2, Fig. 1) " will freeze the current reading value with a "HOLD" symbol on the display.
5-2 Data Record Function
1) The Data Record function records & displays the maximum
and minimum reading values. Start the Data Record function by pressing the " REC Button " ( 3-3, Fig. 1 ) once. There will be a " REC " symbol on the display.
9
2) With the REC symbol on the display :
(a) Press the " REC Button " ( 3-3, Fig. 1 ) once and the " Max " symbol along with the maximum value will appear on the display. (b) Press the " REC Button " again, the " Min " symbol along with the minimum value will appear on the display. (c) To exit the memory record function, press the " REC Button " continuously for at least 2 seconds. The display will revert to the current reading. (d) Clear the Max./Min. value recorded by pressing the " Hold Button " ( 3-2, Fig. 1 ) once. Previous recorded Max./Min. value will be given up and then revert to the REC. function keep on recording.
5-3 Auto Power Off Disable
In order to prolong the battery life, the instrument has "Auto Power Off " function. The meter will switch off automatically if no buttons are pressed for around 10 minutes.
6. BATTERY REPLACEMENT
1)
When the LCD display shows " " symbol, it is necessary
to replace the battery. However measurement may still be made for several hours after the low battery indicator appears.
2) Open the " Battery Compartment / Cover " ( 3-12, Fig. 1) and
remove the battery.
3) Install a 9V battery (Alkaline or Heavy duty type) and then
reinstate the cover.
10
7. OPTIONAL TEMPERATURE PROBE AND OTHER ACCESSORIES
Thermocouple Probe (Type K) TP-01 * Measuring Range : -40 to 250
( -40 to 482 ) * Max. short-term operating temperature: * It's an ultra fast response naked-bead
thermocouple suitable for many general
Thermocouple Probe purpose application. (Type K) TP-02A * Measuring Range : -50 to 900
( -50 to 1650 )
Thermocouple Probe * Dimension: 10cm tube, 3.2 mm Dia. (Type K) TP-03 * Measuring Range : -50 to 1200
( -50 to 2200 )
Thermocouple Probe * Dimension: 10cm tube, 8 mm Dia. (Type K) TP-04 * Measuring Range : -50 to 400
* surface Temp.
( -50 to 752 )
probe.
* Size :
Temp. sensing head - 15 mm Dia.
Carrying case Probe length - 12 mm. CA-52A * High quality carrying case with sash.
11
0701-LM-8010