Lutron V-1000-IV, V-1000-BL Installation Manual

Page 1
Incandescent Applications
(V-600, V-1000,VETS-1000, VETS-1000-SL, VETS-R, and VETS-A-SL) These controls are for use with incandescent and halogen lamps only, 120 V~ 60 Hz. Do not connect to receptacles, fluorescent fixtures, motor­operated appliances, or transformer-supplied appliances.
Magnetic Low-Voltage (MLV) Applications
(V-600, V-1000,VETS-1000, VETS-1000-SL, VETS-R, and VETS-A-SL) These controls are for use with low-voltage incandescent and halogen lamps only. Use with core and coil (magnetic) low-voltage transformers. Do not con­nect to receptacles, fluorescent fixtures, or motor-operated appliances. Do not attempt to control a solid-state electronic low-voltage transformer. For more information call the
Lutron Technical Support Center
and ask for Application
Note 19:
Guide to Dimming Low-Voltage Lighting
. Operation of a dimmed MLV circuit with all lamps removed or inoperative may result in current flow in excess of normal levels. To avoid possible transformer failure, Lutron strongly recommends the following:
a. Do not operate dimmed MLV circuits without operative lamps in place. b. Replace burned-out bulbs immediately. c. Use transformers with thermal protection or fuse the transformer primary
windings to prevent transformer failure due to overcurrent.
Electronic Low-Voltage (ELV) Applications
(VETN-1000 only) This control is for use with low-voltage incandescent and halogen lamps only. Use with a solid state electronic low-voltage transformer. Do not connect to receptacles, or motor-operated appliances. For more information call the
Lutron Technical Support Center
and ask for Application Note 19:
Guide to
Dimming Low-Voltage Lighting
.
Fluorescent Switching Applications
(VETN-1000, VETS-1000, and VETS-1000-SL only) These controls are for use with electronic fluorescent ballasts only. Some high power factor magnetic fluorescent ballasts with shunt capacitor connection for compact fluorescent lamps may not operate properly with this control. Do not connect to receptacles or motor-operated appliances. For more information contact your ballast manufacturer or the
Lutron Technical Support Center
.
Important Notes
1. Install in accordance with all national and local electrical codes.
2. These controls are designed to operate in ambient temperatures from
32 °F to 104 °F (0 °C to 40 °C).
3. Strip wallbox wires. Important: When making wire connections, follow
the recommended strip lengths and combinations for the supplied wire connectors. Twist wire connector tight making sure that no bare wire is exposed. Note: Wire connectors provided are suitable for copper wire only. For aluminum wire, consult an electrician.
4. Check for short circuits in new installations before wiring controls. With power OFF, use an appropriate switch and connect to line and lamp. Turn the power ON. If breaker trips, a short is present. Correct wiring and check circuit again. Install control only when short is no longer present.
5. Auxiliary Switching: V-600, V-1000, VETS-1000, and VETN-1000 use a VETS-R for auxiliary switching up to 9 additional locations. VETS-1000-SL uses a VETS-A-SL for auxiliary switching up to 4 additional locations. Controls will not work with standard 3-way and 4-way switches.
6. VETN-1000 and VETS-1000-SL require a neutral connection. Their auxil­iaries, VETS-A-SL and VETS-R, do not require a neutral connection.
7. Multiphase applications: Use a separate neutral for each phase containing a control circuit. For more information call the
Lutron Technical Support
Center
and ask for Application Note 17:
Common Neutral Interaction
.
Cleaning Instructions
To clean, wipe with a soft clean damp cloth. DO NOT use any chemical cleaning solutions.
Wiring
If more than one control is to be installed in the same wallbox, review Multigang Installation section (back page) before beginning.
1. Turn power OFF at fusebox or circuit breaker.
Installation Instructions
Please Leave for Occupant
Electronic Tapswitch Dimmers
V-600 120 V~ 60 Hz 600 W Incandescent
120 V~ 60 Hz 600 VA / 450 W MLV
V-1000 120 V~ 60 Hz 1000 W Incandescent
120 V~ 60 Hz 1000 VA / 800 W MLV
Electronic Tapswitches
VETN-1000, VETS-1000, VETS-1000-SL 120 V~ 60 Hz 1000 W
Auxiliary Tapswitch
VETS-R, VETS-A-SL 120 V~ 60 Hz 8.3 A
Small
Large
Wiring
Diagram
Small:
Strip insulation 3/8 in (10 mm) for 14 AWG (1.5 mm
2
) wire.
Strip insulation 1/2 in (13 mm) for 16 AWG (1.0 mm
2
) or
18 AWG (0.75 mm
2
) wire.
Use to join one 14 AWG (1.5 mm
2
) supply wire with one
16 AWG (1.0 mm
2
) or 18 AWG (0.75 mm2) control wire.
Large:
Strip insulation 1/2 in (13 mm) for 10 AWG (6 mm
2
),
12 AWG (2.5 mm
2
), or 14 AWG (1.5 mm2) wire.
Strip insulation 5/8 in (16 mm) for 16 AWG (1.0 mm
2
)or
18 AWG (0.75 mm
2
) wire.
Use to join one or two 12 AWG (2.5 mm
2
)or
14 AWG (1.5 mm
2
) supply wires with one 10 AWG (6 mm2),
12 AWG (2.5 mm
2
), 14 AWG (1.5 mm2), 16 AWG (1.0 mm2), or
18 AWG (0.75 mm
2
) control wire.
Model Number
V-600, V-1000, VETS-1000 Single-Pole 1
Multi-Location 3
VETS-R Multi-Location 3, 5 VETS-1000-SL Single-Pole 2
Multi-Location 4 VETS-A-SL Multi-Location 4 VETN-1000 Single-Pole 2
Multi-Location 5
2. Remove faceplate from control to access mounting holes. Pull from top of faceplate to remove.
3. Wire control per appropriate wiring diagram (see next page) using wire connectors provided. Dots on diagrams represent wire connectors and color names refer to the wire color on the control.
Warning: Verify that power is OFF before proceeding. Failure to turn power OFF could cause death or serious injury.
P/N 030-1021
ON
ON
ON
OFF
OFF
OFF
Page 2
Wiring Diagram 1
Wiring Diagram 2
Wiring Diagram 3
Wiring Diagram 4
Line-Side Control Wiring Diagram
Line-Side Control Wiring Diagram
Load-Side Control Wiring Diagram
Load-Side Control Wiring Diagram
Live
Red
Green
120 V 60 Hz
Blue Blue Blue
Green
Green
Black
Black
Black
Load
Red Red
Neutral
Up to four VETS-A-SL units
Up to four VETS-A-SL units
Up to nine VETS-R units
Up to nine VETS-R units
Additional
VETS-R
Additional
VETS-R
VETS-R
Live
Red
Green
Cap off blue wire
Ground
120 V 60 Hz
Blue
Black
Load
Neutral
V-600, V-1000,
VETS-1000
V-600, V-1000,
VETS-1000
V-600, V-1000,
VETS-1000
Live
Black Black Black
Green Green Green
120 V 60 Hz
Blue
Blue Blue
Red
Red Red
Load
Neutral
VETS-R
VETS-A-SL
Additional
VETS-A-SL
Live
Red Red Red
Green Green Green
120 V 60 Hz
Blue Blue
Blue
Cap off blue wire
Black
White
Orange Orange
Black Black
Load
Neutral
VETS-1000-SL
VETS-1000-SL
Additional
VETS-A-SL
Live
Black Black Black
Green Green Green
120 V~ 60 Hz
Orange Orange
White
Cap off blue wire
Red
Blue
Blue Blue
Red Red
Load
Neutral
VETS-A-SL
Wiring Diagram 5
Line-Side Control Wiring Diagram
Load-Side Control Wiring Diagram
Up to four VETS-R units
Up to four VETS-R units
VETS-R
Additional
VETS-R
Live
Red Red Red
Green Green Green
120 V 60 Hz
Blue Blue
Blue
Cap off blue wire
Black
White
Orange Orange
Black Black
Load
Neutral
VETN-1000
VETN-1000
Additional
VETS-R
Live
Black
Black
Black
Green Green Green
120 V~ 60 Hz
Orange Orange
White
Cap off blue wire
Red
Blue
Blue Blue
Red Red
Load
Neutral
VETS-R
Live
Red
Green
Cap off blue wire
120 V 60 Hz
Blue
Black
White
Load
Neutral
VETN-1000 VETS-1000-SL
2
Page 3
Mounting Instructions
1. Push wires into wallbox, allowing room for control backbox to be inserted. Do not pinch wires between wallbox and control.
2. Mount control to wallbox using screws provided.
3. Replace the Faceplate.
4. Turn power on.
Operation
Electronic Tapswitch Dimmers
Push button in center of dimmer to turn lights on and off. Raise slider to increase light intensity. Lower slider to decrease light intensity.
Electronic Tapswitches
Push button in center of Tapswitch to turn lights on and off.
Electronic Tapswitches with Status Light
Push button in center of Tapswitch to turn lights on and off. The status light will be lit when the circuit is on. The status light will turn off when the circuit is off.
For routine lamp replacement, power may be conveniently disconnected from fixtures by pulling the clear
FASS
(Front-Accessible Service Switch) so OFF is visible (see below). For any procedure other than routine lamp replacement, power must be disconnected at the main electrical panel. The
FASS
switch
must be returned to the up (on) position in order to operate lights.
FASS
Switch Location
Wallbox
Control Mounting Screws
Adapter Mounting Screws
Control
Faceplate Adapter
Button
Faceplate
System On System Off
3
O
FF
Wallbox
Mini-Slider
Mini-Slider
Control
Faceplate Adapter
Button
Faceplate
To groove in right side of faceplate adapter
Feet
To groove in right side of faceplate adapter
Rectangular slot
Notched lever
protruding from yoke
Notched arm
Rectangular slot
Right side of faceplate adapter
To left side of faceplate adapter
Mini-slider attached to notched lever
Component Assembly (V-600, V-1000)
1. Make sure that the faceplate adapter is correctly mounted to the control. (Observe the UP arrows on the faceplate adapter and make sure that the FASSTM switch is in the lower right corner.)
2. Hold the mini-slider so that the two feet face right and the notched arm faces left. Fit the feet into the groove on the right side of the faceplate adapter and fit the arm into the notched slider in the control. Slide the mini-slider up and down to make sure it slides smoothly.
3. To mount the button, hold it so that the name LUTRON appears in the lower left corner. Fit the plastic slider on the left side of the button into the left groove of the faceplate adapter. Push the two legs on the right side of the button gently into the slot in the control. The button should fit loosely but not fall out.
4. Mount the faceplate to the control.
Component Assembly VETN-1000, VETS-1000-SL, VETS-A-SL, VETS-1000, VETS-R
ON
OFF
ON
OFF
ON
OFF
Page 4
0123456
0 0123456 1 1345678 2 35678910 3 5789101112 4 7 9 10 11 12 13 14
V-600 S 600 W / VA 500 W / VA 400 W / VA V-1000 S 1000 W / VA 900 W / VA 700 W / VA VETN-1000 S 1000 W / VA 800 W / VA 650 W / VA VETS-1000 S 1000 W / VA 800 W / VA 650 W / VA VETS-1000-SL S 1000 W / VA 800 W / VA 650 W / VA VETS-R S 8.3 A * * VETS-A-SL S 8.3 A * *
* When ganging an even number of small controls with side sections intact
and there are no large controls, use gangable 3 x 2 in (76 x 51 mm) wall­boxes. Space an additional wallbox 3/4 in (19 mm) apart from the other wallboxes. A 3/4 in (19 mm) chase nipple is recommended as a spacer between wallboxes.
Example: Wallbox arrangement required for ganging 4 small controls with no side sections removed.
Multigang Installation
Multiple controls can be installed in a common gangable wallbox or a series of interconnected wallboxes for a clean, consolidated appear­ance. Lutron multigang faceplates are available to complete the installation. Refer to instruction sheet supplied with the multigang faceplate for installation. For new installations, controls can be ganged without removing side sections. However, to reduce the size of the multigang installation or to fit existing wallboxes, inner side sections must be removed. Because side sections are designed to dissipate heat, removing them requires derating the capacity of the control. Note: When ganging any combination of small and large controls, place all small controls on one end of the gang and all large controls on the other. Use the chart below to determine the size and rating of each control.
Control Size and Rating Chart
Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299 U.S.A. Made and printed in U.S.A. 8/08 P/N 030-1021 Rev. A
Do not remove outer side sections.
Remove inner side sections (shaded) only.
Single-gang wallbox
3/4 in (19 mm) space (use chase nipple or Lutron P/N “PLUS-ADPTR-3.5”)
Four-gang wallbox
Remove inner side sections from controls. Using pliers, bend side sections up and down until they break off.
Number of Large Controls
Number of Small Controls
No Fins Broken (No Side Sections Removed)
(Capacity reduction not required)
Wallbox Requirement Chart
0123456
0 0 1 1+1* 4 4+1* 7 7+1* 1 13568911 2 4 6 7 9 10 12 13 3 6 8 10 11 13 14 16 4 9111214151718
Number of Small Controls
Number of Large Controls
Model
Control Size No Sides
Removed
1 Side
Removed
2 Sides
Removed
Fins Broken (Side Sections Removed)
(Capacity reduction required)
Wallbox Requirement Chart
* No derating required for VETS-R and VETS-A-SL
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WAR­RANTY OF MERCHANTABILITY IS LIMITED TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR DAMAGE RESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES. LUTRON’S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE UNIT.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential dam­ages, or limitation on how long an implied warranty may last, so the above limitations may not apply to you.
This product may be covered by one or more of the following U.S. patents: 4,954,768; 5,637,930; and corresponding foreign patents. Lutron and Vareo are registered trademarks and FASS is a trademark of Lutron Electronics Co., Inc.
© 2008 Lutron Electronics Co., Inc.
Worldwide Technical and Sales Assistance
For questions concerning the installation or operation of these products, call the Lutron Technical Support Center. Please provide the exact model number when calling.
1.800.523.9466 (U.S.A., Canada, and the Caribbean) Other Countries call +1.610.282.3800 Fax +1.610.282.6311 Visit our web site at www.lutron.com