The CasétaR Wireless family of Dimmers and
Switches can be controlled directly and remotely
when paired with PicoR Remote Controls providing
a system that delivers convenience and ease of
installation.
CasétaR Wireless Dimmers and Switches use
LutronR patented Clear ConnectR RF Technology
which enables wireless communication with PicoR
Remote Controls and the LutronR Smart Bridge and
Smart Bridge PRO.
Features
CasétaR Wireless
In-Wall Switch
CasétaR Wireless
In-Wall Dimmer
• Works with PicoR Remote Control
• Works with the LutronR App (via a Smart Bridge or
Smart Bridge PRO)
1
• LutronR patented Clear ConnectR RF Technology
works through walls and floors
• Includes Front Accessible Service Switch (FASST)
for safe lamp replacement
• Works with LutronR Radio Powr SavrT Occupancy
and Vacancy Sensors in standalone applications
(sensors do not work with Smart Bridge or Smart
Bridge PRO)
CasétaR Wireless
ELV+ Dimmer
CasétaR Wireless
Plug-In Lamp Dimmer
Note: Certain models or load types will require a neutral connection. (see Load Types and Capacity sections)
1
The Lutron® App is required for setup and usage with the Smart Bridge and Smart Bridge PRO. The LutronR App is compatible with iOSR devices version 8.0
or later and AndroidT devices 4.0 or later.
iOS is a registered trademark of Cisco in the U.S. and other countries and is used under license.
Android is a trademark of Google Inc.
SPECIFICATION SUBMITTALPage
Job Name:
Model Numbers:
Job Number:
®
CasétaR WirelessLoad Controls
2
369987a 2 09.09.16
Specifications
Regulatory Approvals
• cULus Listed
• NOM Certified
• FCC Approved. Complies with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules
• Industry Canada Certified
• IFTEL Certified
• NEMA 410 (-6ANS, -5WS, -10NXD, and -5NE)
Power
Operating voltage:
• 120 V~ 50/60 Hz: -3PCL, -6WCL, -10NXD, -6ANS,
-5NE
• 120 / 277 V~ 50 / 60 Hz: -5WS-DV
Key Design Features
• Tested to withstand electrostatic discharge without
damage or memory loss, in accordance with
IEC 61000-4-2.
• Tested to withstand surge voltages without damage
or loss of operation, in accordance with IEEE
C62.41-1991 Recommended Practice on Surge
Voltages in Low-Voltage AC Power Circuits.
• Load controls always operate locally and do not
require system control.
• Power failure memory: should power be interrupted,
the control will return to its previously set level prior
to the interruption when power is restored.
• PD-5WS-DV, PD-6ANS, and PD-10NXD use
conventional 3-way wiring.
• Uses LutronR ClaroR Wallplates or designer-style
wallplates from other manufacturers. Wallplates are
sold separately.
• LutronR ClaroR Wallplates snap on with no visible
means of attachment.
1
• Requires a 1-gang U.S. wallbox. 3
1
depth recommended, 2
⁄4 in (57 mm) depth
⁄2 in (89 mm)
minimum.
• Green status LED(s) to indicate load status.
System Communications and Capacity
• CasétaR Wireless In-Wall Switches and Dimmers
communicate with PicoR remote controls and the
LutronR Smart Bridge/Smart Bridge PRO through
Radio Frequency (RF).
• The CasétaR Wireless In-Wall Switches and Dimmers
communicate with LutronR Radio Powr SavrT
Occupancy and Vacancy
Sensors in a standalone
application. Sensors do not work with Smart Bridge
or Smart Bridge PRO.
• The CasétaR Wireless In-Wall Switches and Dimmers
must be located within 60ft (18m) line-of-sight or
30ft (9m) through walls, of PicoR remote controls
and LutronR Smart Bridge devices.
Device limits
• PicoR Remote Controls and Radio Powr SavrT
Occupancy Sensors: up to 10devices (total) may
be paired to each CasétaR Wireless In-Wall Switch/
Dimmer (with no Smart Bridge installed).
• Smart Bridge or Smart Bridge PRO system: up to
50total wireless devices (CasétaR Wireless Dimmers/
Switches, PicoR Remote Controls, and Shades) are
supported per system. Smart Bridge or Smart Bridge
PRO counts as one device.
Environment
• Ambient operating temperature: 32°F to 104°F
(0°C to 40°C), 0% to 90% humidity,
non-condensing. Indoor use only.
• PD-5WS-DV, PD-6ANS, and PD-10NXD can be used
with mechanical switch in 3-way applications.
SPECIFICATION SUBMITTALPage
Job Name:
Job Number:
Model Numbers:
®
CasétaR WirelessLoad Controls
3
369987a 3 09.09.16
Features
Simple two-wire installation (no neutral
wire required)
Capable of dimming loads
Favorite button (user defined one touch
light level)
Works with Hi-lumeR 1% 2-Wire LED
Drivers (Forward-phase only)
Works with Power Interfaces (PHPM and
GRX TVI)
Works with Power Interfaces (PHPM-SW)
No wiring required
PRO Dimmer
PD-10NXD
1
√
Plug-In
Dimmer
PD-3PCL
In-Wall
Dimmer
PD-6WCL
ELV+
Dimmer
PD-5NE
√√
2-wire Switch
PD-5WS-DV
√√√√
√
√√√√
√√
√
Neutral
Switch
PD-6ANS
√
1
In some low-wattage applications the PD-10NXD will require a neutral wire connection.
SPECIFICATION SUBMITTALPage
Job Name:
Model Numbers:
Job Number:
®
CasétaR WirelessLoad Controls
4
369987a 4 09.09.16
Load Type and Capacity - Switches
Model NumberDescription VoltageLoad TypeMinimum Load
120 V~
277 V~
Incandescent /
Halogen
Incandescent /
Halogen
25 W600 W450 W350 W
25 W135 0 W110 0 W800 W
Maximum Load
Not GangedEnd of GangMiddle of Gang
3
120 V~MLV25 W600 VA /475 W450 VA / 350 W 350 VA / 275 W
PD-5WS-DV
1
Two -w ire
switch
277 V~MLV25 W1350 VA /1075 W 1100 VA / 875 W 800 VA / 625 W
120 V~
120 / 277 V~ LEDUse LUT-MLC
120 / 277 V~ FluorescentU s e LUT- M LC
120 V~ELVUse LU T- ML C
277 V~ELVUs e L U T- M L C
General
Purpose Fan
Incandescent /
Halogen
0.4 A3 A3 A3 A
2
5 A4 A3 A
2
5 A4 A3 A
2
600 W450 W350 W
2
135 0 W110 0 W800 W
10 W720 W720 W600 W
MLV10 W720 VA720 VA60 0 VA
Neutral-wire
PD-6ANS
switch
(neutral
connection
required)
120 V~
Fan0.1 A3.6 A3.6 A3.6 A
LED1 bulb6 A6 A5 A
Fluorescent1 ballast6 A6 A5 A
ELV10 W720 VA720 VA600 VA
PHPM-SW1 inter face3 interfaces3 interfaces3 interfaces
1
No neutral wire required.
2
To ensure proper operation of the switch with LED, fluorescent, and ELV loads, a LUT-MLC may be required, especially at lower wattages. If the status LED
on the switch is flashing or solid red in color, a LUT-MLC must be installed. To guarantee best performance, installing a LUT-MLC with these load types
regardless of wattage is recommended. Rarely, some load types may still flicker or glow in the off state even with the LUT-MLC installed, in which case a
different load may be required or more than one LUT-MLC is required.
3
See “Ganging and Derating” section.
SPECIFICATION SUBMITTALPage
Job Name:
Model Numbers:
Job Number:
®
CasétaR WirelessLoad Controls
5
369987a 5 09.09.16
Load Type and Capacity - Dimmers
Model NumberDescriptionVoltage Load TypeMinimum Load
When using controls without a mechanical 3-way switch, cap the blue terminal. Do not connect the blue wire to any other wiring or to ground.
2
A LUT-MLC ensures proper function when LED, fluorescent, or ELV loads are used. Install the LUT-MLC inside a load fixture or in a separate junction box
within the circuit.
3
The red wire must be connected to the load and the black wire must be connected to Line/Hot. The switch will not work if the wires are reversed.
Ground
(continued on next page…)
SPECIFICATION SUBMITTALPage
Job Name:
Model Numbers:
Job Number:
®
CasétaR WirelessLoad Controls
11
369987a 11 09.09.16
Wiring Diagrams - Switches (cont.)
3-Way Installation (with mechanical switch)
Option 1
PD-5WS-DV (Load-side)
Location 2
Location 1
Brass
Line/Hot
120 / 277 V~
50/60 Hz
Neutral
Black
PD-5WS-DV (Line-side)
Location 1Location 2
Line/Hot
120 / 277 V~
50/60 Hz
Neutral
Black
Mechanical
PD-5WS-DV
Switch
1
Brass
Jumper
wire
Ground
Blue
1
Black
Green
Ground
Black
Brass
Jumper wire
PD-5WS-DV
Mechanical
Switch
1
Green
Ground
Brass
1
Black
Ground
Blue
Black
Load
Load
LU T- M LC
LU T- M LC
2
2
1
Location of Caséta® Wireless In-Wall Switch and mechanical switch may be reversed.
2
A LUT-MLC ensures proper function when LED, fluorescent, or ELV loads are used. Install the LUT-MLC inside a load fixture or in a separate junction box within the circuit.
SPECIFICATION SUBMITTALPage
Job Name:
Model Numbers:
Job Number:
(continued on next page…)
®
CasétaR WirelessLoad Controls
12
369987a 12 09.09.16
Wiring Diagrams - Switches (cont.)
3-Way Installation (with mechanical switch)
Option 1 (cont.)
PD-6ANS (Load-side)
Location 1
Location 2
Line/Hot
120 V~ 50/60 Hz
Neutral
PD-6ANS (Line-side)
Line/Hot
120 V~
50/60 Hz
Brass
Black
Location 1
Black
Mechanical
1
Switch
PD-6ANS
Brass
Jumper
wire
Ground
Blue
1
Red
GreenWhite
Blue
BlackRed
PD-6ANS
1
GreenWhite
Ground
3
Load
Location 2
Brass
3
Mechanical
Switch
Jumper wire
1
Ground
Brass
Black
Load
Neutral
1
Location of Caséta® Wireless In-Wall Switch and mechanical switch may be reversed.
2
A LUT-MLC ensures proper function when LED, fluorescent, or ELV loads are used. Install the LUT-MLC inside a load fixture or in a separate junction box within the circuit.
3
The red wire must be connected to the load and the black wire must be connected to Line/Hot. The switch will not work if the wires are reversed.
Ground
SPECIFICATION SUBMITTALPage
Job Name:
Model Numbers:
Job Number:
®
CasétaR WirelessLoad Controls
13
369987a 13 09.09.16
Wiring Diagrams - Switches (cont.)
3-Way Installation (with PicoR remote controls)
Option 2: PJ2-2B-xx and wallbox mounting adapters (PICO-WBX-ADAPT)
PD-5WS-DV
Location 1
Location 2
Line/Hot
120 / 277 V~ 50/60 Hz
Neutral
PD-6ANS
Line/Hot
Black
Pico
®
Remote
Control and
Wallbox
Mounting
3
Adapter
Tra v e l e r s
Location 1Location 2
Black
Pico®
Remote
Control and
Wallbox
Mounting
3
Adapter
Tra v e l e r s
Black
PD-5WS-DV
Black
PD-6ANS
Green
Ground
Blue
Black
Blue
Red
1
Load
1
4
LU T- M LC
2
120 V~ 50/60 Hz
Neutral
1
When using controls without mechanical 3-way switch, cap the blue terminal. Do not connect the blue wire to any other wiring or to ground.
2
A LUT-MLC ensures proper function when LED, fluorescent, or ELV loads are used. Install the LUT-MLC inside a load fixture or in a separate junction box
within the circuit.
3
The mechanical switch will need to be removed so the PicoR Remote Control can be installed.
4
The red wire must be connected to the load and the black wire must be connected to Line/Hot. The switch will not work if the wires are reversed.
GreenWhite
Ground
Load
(continued on next page…)
SPECIFICATION SUBMITTALPage
Job Name:
Model Numbers:
Job Number:
®
CasétaR WirelessLoad Controls
14
369987a 14 09.09.16
Wiring Diagrams - Switches (cont.)
Multi-location Installation (3 or more switches control the load)
With Pico
PD-5WS-DV
® remote controls (PJ2-2B-xx) and wallbox mounting adapters (PICO-WBX-ADAPT)
Location 1Location 2Location 3
Line/Hot
120 / 277 V~
50/60 Hz
Neutral
PD-6ANS
Line/Hot
Black
Pico®
Remote
Control and
Wallbox
Mounting
3
Adapter
Tra v e l e r s
Pico®
Remote
Control and
Wallbox
Mounting
Adapter
Location 1Location 2
Black
Pico®
Remote
Control and
Wallbox
Mounting
3
Adapter
Tra v e l e r s
Pico®
Remote
Control and
Wallbox
Mounting
Adapter
Black
1
Tra v e l e r s
Blue
PD-5WS-DV
3
Green
Black
Load
LU T- M LC
2
Ground
Location 3
Black
1
Tra v e l e r s
PD-6ANS
3
Blue
Red
4
120 V~ 50/60 Hz
Neutral
1
When using controls without mechanical 3-way switch, cap the blue terminal. Do not connect the blue wire to any other wiring or to ground.
2
A LUT-MLC ensures proper function when LED, fluorescent, or ELV loads are used. Install the LUT-MLC inside a load fixture or in a separate junction box
within the circuit.
3
The mechanical switch will need to be removed so the PicoR Remote Control can be installed.
4
The red wire must be connected to the load and the black wire must be connected to Line/Hot. The switch will not work if the wires are reversed.
GreenWhite
Ground
SPECIFICATION SUBMITTALPage
Job Name:
Model Numbers:
Job Number:
Load
®
CasétaR WirelessLoad Controls
15
369987a 15 09.09.16
Wiring Diagrams - Dimmers
Single Location Installation
PD-10NXD or PD-5NE
1, 5
Blue
In-Wall
Line / Hot
Black
Dimmer
Red
120 V~
50 / 60 Hz
Neutral
PD-6WCL
Line / Hot
120 V~
50 / 60 Hz
Neutral
3,4
White
In-Wall
BlackBlack
Dimmer
Green
Ground
Green
Ground
Load
Load
1
When using controls without mechanical 3-way switch, cap the blue terminal. Do not connect the blue wire to any other wiring or to ground.
2
Location of CasétaR Wireless In-Wall Dimmer PRO and mechanical switch may be reversed.
3
For PD-10NXD only, neutral connection optional except for MLV loads, LED drivers, and power modules (PHPM-PA, PHPM-3F, and GRX-TVI).
4
For PD-5NE, neutral is required.
5
Blue wire is only present on the PD-10NXD model.
SPECIFICATION SUBMITTALPage
Job Name:
Model Numbers:
Job Number:
®
CasétaR WirelessLoad Controls
16
369987a 16 09.09.16
Wiring Diagrams - Dimmers (cont.)
Multi-Location Installation
With PicoR remote controls (PJ2-XX-XX) and wallbox mounting adapters (PICO-WBX-ADAPT)
PD-10NXD and PD-5NE
Location 1Location 2Location 3
Black
Black
Line / Hot
120 V~
50 / 60 Hz
Neutral
PD-6WCL
Line / Hot
120 V~
50 / 60 Hz
Neutral
PicoR
remote
control &
wallbox
mounting
adapter
Black
PicoR
remote
control &
wallbox
mounting
adapter
Travelers
Travelers
PicoR
remote
control &
wallbox
mounting
adapter
PicoR
remote
control &
wallbox
mounting
adapter
Travelers
Travelers
White
3,4
Dimmer
Black
In-Wall
In-Wall
Dimmer
Blue
Red
Green
Ground
Black
Green
1, 5
Load
Load
Ground
1
When using controls without mechanical 3-way switch, cap the blue terminal. Do not connect the blue wire to any other wiring or to ground.
2
Location of CasétaR Wireless In-Wall Dimmer PRO and mechanical switch may be reversed.
3
For PD-10NXD only, neutral connection optional except for MLV loads, LED drivers, and power modules (PHPM-PA, PHPM-3F, and GRX-TVI).
4
For PD-5NE, neutral is required.
5
Blue wire is only present on the PD-10NXD model.
SPECIFICATION SUBMITTALPage
Job Name:
Job Number:
Model Numbers:
®
CasétaR WirelessLoad Controls
L/H
N
DH
17
369987a 17 09.09.16
Wiring Diagrams - Dimmers (cont.)
3-Way Installation
With mechanical switch
PD-10NXD
Line/Hot
120 V~
50/60 Hz
Location 1
Brass
Mechanical
Switch
Black
Ground
Brass
2
Jumper wire
(included)
Location 2
Black
3
White
In-Wall
Dimmer
2
Green
Blue
Red
Load
Neutral
Installation with PHPM - Neutral required
PD-10NXD and PD-5NE
Location 1
Red
Line/Hot
Black
120 V~
60 Hz
Neutral
White
In-Wall
Dimmer
Blue
Green
Ground
1, 5
Ground
4
PHPM
Ground
Control Neutral
Zone In
Load
1
When using controls without mechanical 3-way switch, cap the blue terminal. Do not connect the blue wire to any other wiring or to ground.
2
Location of In-Wall Dimmer and mechanical switch may be reversed.
3
Neutral connection optional except for MLV loads, LED drivers, and power modules (PHPM-PA, PHPM-3F, and GRX-TVI).
4
See LutronR P/Ns 369356 and 369355 for additional wiring diagrams.
5
Blue wire is only present on the PD-10NXD model.
Job Name:
SPECIFICATION SUBMITTALPage
Model Numbers:
Job Number:
®
CasétaR WirelessLoad Controls
L
2
/H
2
100-277 V~
18
369987a 18 09.09.16
Wiring Diagrams - Dimmers (cont.)
Installation with GRX-TVI - Neutral required
PD-10NXD and PD-5NE
Location 1
Red
1
GR X-TVI
Line/Hot
Black
120 V~
60 Hz
Neutral
Neutral 2
White
In-Wall
Dimmer
Blue
Green
Ground
2
Ground
Installation with Hi-lumeR 1% 2-wire LED Drivers - Neutral required
PD-10NXD and PD-5NE
Line/Hot
Neutral
Black
White
Red
In-Wall
Dimmer
Blue 2
Green
Ground
White
Black
Hi-lumeR 1%
2-wire LED
Driver
Red
Black with White
Stripes
LED Light
Engine
Note: For more information on Hi-lumeR 1% 2-wire LED Drivers, see www.lutron.com
1
See LutronR P/N 369247 for additional wiring diagrams.
2
Blue wire is only present on the PD-10NXD model.
SPECIFICATION SUBMITTALPage
Job Name:
Model Numbers:
Job Number:
®
CasétaR WirelessLoad Controls
19
369987a 19 09.09.16
Colors and Finishes
Gloss Finishes
White
WH
Black
BL
Ivory
IV
Light Almond
LA
Due to printing limitations, colors and finishes shown
cannot be guaranteed to perfectly match actual
product colors.
Job Name:
Job Number:
SPECIFICATION SUBMITTALPage
Model Numbers:
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.