Lutron PD-10NXD, PD-3PCL, PD-5NE, PD-6WCL Specification Sheet

®
CasétaR Wireless Load Controls
1
369987a 1 09.09.16
The CasétaR Wireless family of Dimmers and Switches can be controlled directly and remotely when paired with PicoR Remote Controls providing a system that delivers convenience and ease of installation.
CasétaR Wireless Dimmers and Switches use LutronR patented Clear ConnectR RF Technology which enables wireless communication with PicoR Remote Controls and the LutronR Smart Bridge and Smart Bridge PRO.
Features
CasétaR Wireless
In-Wall Switch
CasétaR Wireless
In-Wall Dimmer
• Works with PicoR Remote Control
• Works with the LutronR App (via a Smart Bridge or Smart Bridge PRO)
1
• LutronR patented Clear ConnectR RF Technology works through walls and floors
• Includes Front Accessible Service Switch (FASST) for safe lamp replacement
• Works with LutronR Radio Powr SavrT Occupancy and Vacancy Sensors in standalone applications (sensors do not work with Smart Bridge or Smart Bridge PRO)
CasétaR Wireless
ELV+ Dimmer
CasétaR Wireless
Plug-In Lamp Dimmer
Note: Certain models or load types will require a neutral connection. (see Load Types and Capacity sections)
1
The Lutron® App is required for setup and usage with the Smart Bridge and Smart Bridge PRO. The LutronR App is compatible with iOSR devices version 8.0
or later and AndroidT devices 4.0 or later.
iOS is a registered trademark of Cisco in the U.S. and other countries and is used under license. Android is a trademark of Google Inc.
SPECIFICATION SUBMITTAL Page
Job Name:
Model Numbers:
Job Number:
®
CasétaR Wireless Load Controls
2
369987a 2 09.09.16
Specifications
Regulatory Approvals
• cULus Listed
• NOM Certified
• FCC Approved. Complies with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules
• Industry Canada Certified
• IFTEL Certified
• NEMA 410 (-6ANS, -5WS, -10NXD, and -5NE)
Power
Operating voltage:
• 120 V~ 50/60 Hz: -3PCL, -6WCL, -10NXD, -6ANS,
-5NE
• 120 / 277 V~ 50 / 60 Hz: -5WS-DV
Key Design Features
• Tested to withstand electrostatic discharge without damage or memory loss, in accordance with IEC 61000-4-2.
• Tested to withstand surge voltages without damage or loss of operation, in accordance with IEEE C62.41-1991 Recommended Practice on Surge Voltages in Low-Voltage AC Power Circuits.
• Load controls always operate locally and do not require system control.
• Power failure memory: should power be interrupted, the control will return to its previously set level prior to the interruption when power is restored.
• PD-5WS-DV, PD-6ANS, and PD-10NXD use conventional 3-way wiring.
• Uses LutronR ClaroR Wallplates or designer-style wallplates from other manufacturers. Wallplates are sold separately.
• LutronR ClaroR Wallplates snap on with no visible means of attachment.
1
• Requires a 1-gang U.S. wallbox. 3
1
depth recommended, 2
4 in (57 mm) depth
2 in (89 mm)
minimum.
• Green status LED(s) to indicate load status.
System Communications and Capacity
• CasétaR Wireless In-Wall Switches and Dimmers communicate with PicoR remote controls and the LutronR Smart Bridge/Smart Bridge PRO through Radio Frequency (RF).
• The CasétaR Wireless In-Wall Switches and Dimmers communicate with LutronR Radio Powr SavrT Occupancy and Vacancy
Sensors in a standalone application. Sensors do not work with Smart Bridge or Smart Bridge PRO.
• The CasétaR Wireless In-Wall Switches and Dimmers must be located within 60ft (18m) line-of-sight or 30ft (9m) through walls, of PicoR remote controls and LutronR Smart Bridge devices.
Device limits
• PicoR Remote Controls and Radio Powr SavrT Occupancy Sensors: up to 10devices (total) may be paired to each CasétaR Wireless In-Wall Switch/ Dimmer (with no Smart Bridge installed).
• Smart Bridge or Smart Bridge PRO system: up to 50total wireless devices (CasétaR Wireless Dimmers/ Switches, PicoR Remote Controls, and Shades) are supported per system. Smart Bridge or Smart Bridge PRO counts as one device.
Environment
• Ambient operating temperature: 32°F to 104°F (0°C to 40°C), 0% to 90% humidity, non-condensing. Indoor use only.
• PD-5WS-DV, PD-6ANS, and PD-10NXD can be used with mechanical switch in 3-way applications.
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
®
CasétaR Wireless Load Controls
3
369987a 3 09.09.16
Features
Simple two-wire installation (no neutral wire required)
Capable of dimming loads
Favorite button (user defined one touch light level)
Works with Hi-lumeR 1% 2-Wire LED Drivers (Forward-phase only)
Works with Power Interfaces (PHPM and GRX TVI)
Works with Power Interfaces (PHPM-SW)
No wiring required
PRO Dimmer
PD-10NXD
1
Plug-In
Dimmer
PD-3PCL
In-Wall
Dimmer
PD-6WCL
ELV+
Dimmer
PD-5NE
2-wire Switch
PD-5WS-DV
Neutral
Switch
PD-6ANS
1
In some low-wattage applications the PD-10NXD will require a neutral wire connection.
SPECIFICATION SUBMITTAL Page
Job Name:
Model Numbers:
Job Number:
®
CasétaR Wireless Load Controls
4
369987a 4 09.09.16
Load Type and Capacity - Switches
Model Number Description Voltage Load Type Minimum Load
120 V~
277 V~
Incandescent / Halogen
Incandescent / Halogen
25 W 600 W 450 W 350 W
25 W 135 0 W 110 0 W 800 W
Maximum Load
Not Ganged End of Gang Middle of Gang
3
120 V~ MLV 25 W 600 VA /475 W 450 VA / 350 W 350 VA / 275 W
PD-5WS-DV
1
Two -w ire switch
277 V~ MLV 25 W 1350 VA /1075 W 1100 VA / 875 W 800 VA / 625 W
120 V~
120 / 277 V~ LED Use LUT-MLC 120 / 277 V~ Fluorescent U s e LUT- M LC 120 V~ ELV Use LU T- ML C 277 V~ ELV Us e L U T- M L C
General Purpose Fan
Incandescent / Halogen
0.4 A 3 A 3 A 3 A
2
5 A 4 A 3 A
2
5 A 4 A 3 A
2
600 W 450 W 350 W
2
135 0 W 110 0 W 800 W
10 W 720 W 720 W 600 W
MLV 10 W 720 VA 720 VA 60 0 VA
Neutral-wire
PD-6ANS
switch (neutral connection required)
120 V~
Fan 0.1 A 3.6 A 3.6 A 3.6 A
LED 1 bulb 6 A 6 A 5 A Fluorescent 1 ballast 6 A 6 A 5 A ELV 10 W 720 VA 720 VA 600 VA PHPM-SW 1 inter face 3 interfaces 3 interfaces 3 interfaces
1
No neutral wire required.
2
To ensure proper operation of the switch with LED, fluorescent, and ELV loads, a LUT-MLC may be required, especially at lower wattages. If the status LED
on the switch is flashing or solid red in color, a LUT-MLC must be installed. To guarantee best performance, installing a LUT-MLC with these load types regardless of wattage is recommended. Rarely, some load types may still flicker or glow in the off state even with the LUT-MLC installed, in which case a different load may be required or more than one LUT-MLC is required.
3
See “Ganging and Derating” section.
SPECIFICATION SUBMITTAL Page
Job Name:
Model Numbers:
Job Number:
®
CasétaR Wireless Load Controls
5
369987a 5 09.09.16
Load Type and Capacity - Dimmers
Model Number Description Voltage Load Type Minimum Load
10 W with
Incandescent / Halogen
neutral (25 W without neutral)
MLV Halogen 10 W 1000 VA 80 0 VA 600 VA
PD-10NXD
PD-3PCL
Wireless In-Wall Dimmer PRO (neutral connection
120 V~
required for certain load
4
types)
1
Wireless Plug-In Lamp
120 V~
Dimmer
MLV L E D See Application Note #559
CFL/LED (120 V~
3
Rated)
Hi-lumeR 1% 2-Wire LED drivers
Dimmable Ballasts
PHPM-PA/3F and GRX-TVI
4
5
3
1 bulb
1 driver
1 ballast 1000 VA 800 VA 60 0 VA
1 interface 3 interface 3 interface 3 interface
Incandescent / Halogen 10 W 300 W N/A N /A
CFL/LED (120 V~
3
Rated)
1 bulb
3
Incandescent / Halogen 10 W 500 W 400 W 300 W
PD-5NE
Phase Selectable Dimmer (neutral connection required)
120 V~
CFL/LED (120 V~ Rated)
MLV Halogen
3, 6, 7
2, 6, 7
ELV Halogen 10 W 500 W 400 W 300 W
Hi-lumeR 1% 2-Wire LED drivers
Dimmable Ballasts
PHPM-PA/3F and GRX-TVI
6, 7
5, 6, 7
6, 7
3
1 bulb
10 W 400 VA 400 VA 400 VA
1 driver
1 ballast 400 VA 40 0 VA 400 VA
1 interface 3 interfaces 3 interfaces 3 interfaces
ELV LED See Application Note #559
MLV L E D See Application Note #559
Incandescent / Halogen 25 W 600 W 500 W 400 W
CFL/LED (120 V~ Rated)
3
1 bulb
3
PD-6WCL
Wireless In-Wall Dimmer
120 V~
Maximum Load
Not Ganged End of Gang Middle of Gang
1000 W 800 W 600 W
250 W 250 W 250 W
1000 W (13 dr i vers)
800 W (13 dr i vers)
600 W (13 dr i vers)
100 W N/A N/A
250 W 250 W 250 W
400 W (20 drivers)
400 W (20 drivers)
400 W (20 drivers)
150 W 150 W 150 W
1
Cannot be ganged.
2
Need to change load type to MLV. See www.casetawireless.com/change_phase
3
See bulb list at www.lutron.com/led
4
For PD-10NXD, a neutral connection is required for MLV loads, LED drivers, dimmable ballasts, and power modules (PHPM-PA, PHPM-3F, and GRX-TVI).
5
Compatible dimmable ballasts include Tu-WireR, Mark X, and PowerSenseR.
6
These loads are best operated using a forward-phase control. Consult www.lutron.com/bulblist to ensure the appropriate phase for bulb models used.
7
SSL7 compliant when in forward-phase.
PowerSense is a registered trademark of Osram Sylvania.
SPECIFICATION SUBMITTAL Page
Job Name:
Model Numbers:
Job Number:
®
CasétaR Wireless Load Controls
6
369987a 6 09.09.16
Ganging and Derating
When ganging with other Switches/Dimmers in the same wallbox, derating is required. See “Load Type and Capacity” charts.
Do not remove outside fins on ends of ganged Switches/Dimmers
Each Switch/Dimmer has
inside fins removed
Do not remove outside fins on ends of ganged Switches/Dimmers
Each Switch/Dimmer has
inside fins removed
Middle of ganged Switches/Dimmers
have all fins removed
Middle of ganged Switches/Dimmers
have all fins removed