Lutron MA-LFQ3-WH Installation Manual

Page 1
English
®
?
ON
OFF
ON
OFF
ON
OFF
P/N 033-211
Fan/Light
Quiet Fan Speed and Incandescent/Halogen Dimmer Multi-Location System
Canopy Module
CM-L300FQ1: 120 V~ 60 Hz
MA-LFQ35M: 120 V~ 60 Hz
Accessory Control
MA-ALFQ35: 120 V~ 60 Hz
Warning: For use with one ceiling paddle fan and light only. Do not use with an
Important Notes
Please read before installing.
1. Caution: To avoid overheating and possible damage to other equipment, do not use to control
receptacles, uorescent or neon lighting xtures, transformer-supplied appliances, solid state fan motors, or exhaust fans. For exhaust fans use Lutron fully variable fan speed controls.
2. Install in accordance with all national and local electrical codes.
3. When no “grounding means” exist within the wallbox then the NEC® 2002, Article 404-9 allows
a wall control without a g rounding connection to be installed as a replacement, as long as a plastic, noncombustible wallplate is used. For this type of installation, cap or remove the green ground wire on the wall control and use an appropriate wallplate such as Lutron’s Claro® series wallplates.
4. The Maestro® dual fan/light control system consists of a Wall Control, a Canopy Module, and
up to two Accessory Controls. All must be installed correctly before attempting to control the fan/light xture. Do not attempt to mix Lutron controls with those from other manufacturers, or mix Lutron controls not labeled for use together.
5. This system is not compatible with fans having a control system built into the motor.
6. Do not paint Wall Control, Canopy Module, or Accessory Control.
7. Maestro Controls are not compatible with standard 3-way/4-way switches.
8. Accessory Controls (MA-ALFQ35) cannot be used individually and must be used in conjunction
with a Maestro Wall Control (MA-LFQ35M) in a 3-way/4-way application.
9. In any 3-way/4-way circuit use only one Wall Control (MA-LFQ35M)with up to 2 Accessory
Controls (MA-ALFQ35).
10. Do not use where total lamp wattage is less than 40W or greater than 300 W.
11. Operate between 32 °F (0 °C) and 104 °F (40 °C) room temperature. For indoor use only.
12. Wall Control and Accessory Controls may feel warm to the touch during normal operation.
13. Recommended wallbox depth is 2.5 in (64 mm) minimum.
14. Clean controls with a soft damp cloth only. Do not use any chemical cleaners.
15. This system cannot be used to change the direction of the fan. To change the fan direction,
stop the fan, and then change the position of the switch located on the body of the fan.
16. To maximize light bulb life, use bulbs recommended for fan or “rough service”use.
17. Do not use pull chains to operate fan/light after installing this system.
18. Canopy Module must be installed within a fan canopy enclosure.
19. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
300 W light / 1 A fan (3.5 A total)
3.5 A (one CM-L300FQ1)
3.5 A
exhaust fan or more than one fan.
One ceiling fan only No exhaust fans
Multigang Installations
When installing more than one control in the same wallbox, it may be necessary to remove all inner side sections prior to wiring (see below). Using pliers, bend side sections up and down until they break off. Repeat for each side section to be removed.Note: Product does not require derating
when side sections are removed.
Do not remove
outside
sections.
Breaking Side Sections
Inside sections are removed from each
control
Side sections are
removed from both
sides of middle control
Operation
Light Level Tap Button
Tap once when lights are off -Lights
brighten smoothly to preset intensity.
Tap once when lights are on -Lights
dim smoothly to off.
Tap twice quickly -Lights brighten
rapidly to full intensity.
Press and hold when lights are on -
Activates delayed fade to off mode. As the tap button is held, the LEDs will begin to ash. The rst ashing LED represents a 10 second fade to OFF. Each additional ashing LED represents an additional 10 seconds of delay before lights fade to OFF (up to 60 seconds of delay).
Fan Speed Tap Button
Tap once when fan is off -Fan
speed increases to preset level.
Tap once when fan is on -Fan
speed slows to off.
Tap twice quickly -Fan speed
increases to full speed.
To replace bulb, remove power by pulling the FASS
For any procedure other than routine bulb
replacement,power must be disconnected at the
Light Level LEDs
Indicate approximate light level
LEDs may not change with each press
Press to increase light level Press to decrease light level
Fan speed LEDs
Indicate exact fan speed
LEDs will change with each press
Press to increase fan speed Press to decrease fan speed
(LEDs not available on Accessory Controls)
FASS TM - Front
Accessible
Service Switch
IMPORTANT NOTICE:
switch out on the Control.
main electrical panel.
Troubleshooting
Symptom
Light or fan does not turn ON or no LEDs turn ON.
Upper LEDs on Wall Control cycle rapidly and bottom LED is ON.
Upper LEDs on Wall Control cycle rapidly and second lowest LED is ON.
Fan vibrates or wobbles.
Light dims in large steps and fan is noisy or does not spin at correct speed.
Light button controls fan and vice-versa.
Fan speeds too slow.
Wall Control LEDs respond as expected but fan and/or light does not respond properly.
Possible Cause
Front Accessible Service Switch (FASS ) on control is pulled out to the OFF position.
Manual switch on fan is off (ex: pull chain).
Light bulb(s) burned out.
Breaker is OFF or tripped (or fuse blown).
Fan direction switch is between forward and
reverse.
Wiring error, call Lutron Technical Support Center at +1.800.523.9466.
Unit is not activated properly. Activate system as described in Step 15.
Wiring error, call Lutron Technical Support Center at +1.800.523.9466.
Communication error. Check wiring; if error continues, call Lutron Technical Support Center at +1.800.523.9466.
Fan blades not properly balanced. See fan manufactur
Fan and light control wires on Canopy Module are reversed.
Fan and light control wires on Canopy Module are reversed.
Fan pull chain not set to high.
Fan and/or light pull chains not set to high/on.
Wiring error, call Lutron Technical Support
Center at +1.800.523.9466.
er's instructions.
Technical Assistance
If you have questions concerning the installation or operation of this product, call the Lutron Technical Support Center. Please provide exact model number when calling.
U.S.A. and Canada (24 hrs/7days): +1.800.523.9466
Other countries 8am – 8pm ET: +1.610.282.3800
Fax +1.610.282.1243
http://www.lutron.com
México +1.888.235.2910
Reference Wiring Diagram
Neutral
White
connected.
Switched Live
Black
Junction box and Canopy
Wallbox
See Step 12 for two- and three-location control wiring.
Live
120 V~
60 Hz
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to
- Consult the dealer or an experienced radio/TV technician for help.
Canopy Module
Control
Wall
Brass
Brass
Black
Red (Light)
Yellow (Fan)
Ceiling Fan and Light
Green
Ground
which the receiver is
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre­paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMO VAL OR REINST ALLATION, OR DAMAGE RESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION.THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES. LUTRON’S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT OF THE UNIT.
This warranty gives you specic legal rights, and you may have other rights which vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitation on how long an implied warranty may last, so the above limitations may not apply to you. Lutron, Claro, and Maestro are registered trademarks and FASS is a trademark of Lutron Electronics Co., Inc. NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts. © 2010 Lutron Electronics Co., Inc.
Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299, U.S.A. Made and printed in the U.S.A. 11/10 P/N 033-211 Rev. A
SHALL NEVER EXCEED THE PURCHASE PRICE
Lutron Technical Support Center
1.800.523.9466 24 hrs / 7 days www.lutron.com
Canopy Module Installation
Install fan.
1
Install fan according to manufacturer's instructions and check for proper operation.
Set fan speed and lights.
2
Set fan to highest speed and turn lights on using pull chains.
If two switches control the fan and light separately, note which controls the light.
Turn OFF power.
3
Turn power OFF at circuit breaker (or remove fuse).
Disconnect fan.
4
Remove canopy enclosure from ceiling fan mounting bracket.
If separate wires from the junction box power the fan and light, tag the wire connected to the light wire.
In Step 5, connect this wire to the black Canopy Module wire.
Leave any green ground wires connected as directed in fan manufacturer's instructions.
Disconnect fan from remaining wiring in the ceiling.
Typical Wire Colors
Fan Light Neutral
If the fan and light do not have separate wires, the xture may have a control system built into the motor and cannot be used with this product.
Important Wiring Information
When making wire connections, follow the recommended strip lengths and combinations for the supplied wire connectors (see wire connector bag).Note: All wire connectors provided are suitable for copper wire only.For aluminum wire, consult an electrician.
Wire Connectors:
Use to join 14 or 12 AWG (1.5 or 2.5 mm²) ground wire to 18 AWG (0.75 mm²) Wall Control ground wire, and to join 18 AWG (0.75 mm²) Canopy Module wire to 12 to 18 AWG (2.5 to 0.75 mm²) wire.
Connect Canopy Module.
5
If you have questions about wiring, call the Lutron Technical Support Center at +1.800.523.9466.
To junction box
Switched Live
Canopy
Neutral
Module
To fixture
Black Black with White stripe or Blue White
To junction box To junction box
Mounting bracket
Canopy enclosure
Flush Mount BracketDown Rod Bracket
Wiring the Canopy Module (CM-L300FQ1):
Use wire connectors to join wires as indicated below
Black
Fan
Light
White
Yellow
Red
and in the wiring diagram, and to cap any unused wires.
Canopy Module Wire:
White
Black
Yellow
Red
Connects to:
Neutral wires in the junction box and to fan
Switched Live wire from Wall Control
Fan
Light
Twist wire connector
tight.
Page 2
Lutron Technical Support Center 1.800.523.9466 24 hrs / 7 days www.lutron.com
ON
OFF
ON
OFF
ON
OFF
Insert Canopy Module.
6
6a - Down Rod Bracket
Do not install Canopy Module in ceiling.
Slide Canopy Module into the ceiling fan mounting bracket.
To junction box
6b - Flush Mount Bracket
Do not install Canopy Module in ceiling.
Attach Canopy Module to bracket with a cable tie.
Ensure cable tie does not come in contact with moving motor parts.
Install cable tie through notches on Canopy Module. Pull tight and clip excess.
To junction box
Notch
Cable tie
Control Installation
Remove original wallplate and switch.
8
Remove the wallplate and switch mounting screws.
Carefully remove switches from wall (do not remove wires).
Danger: Verify power to each switch is OFF before proceeding.
Identify the circuit type.
9
9a - Single-Location control
One switch controlling a fan/light fixture.
This switch will be a single-pole. The switch will have insulated wires connected to two screws of the same color plus a green ground screw.
Ground (Bare Copper or Green Wire)
9b - Two-Location control
Two switches controlling a fan/light fixture.
Note: Screw placement may be different on your switch.
Ground (Bare Copper or Green Wire)
Different colored screw (Common)
Tagged wire
Both switches will be 3-way.Each switch will have insulated wires connected to three screws plus a green ground screw. One of these wires is connected to a screw of a different color (not green) or labeled COMMON. TAG this wire on both switches to identify when wiring.
Important Wiring Information
Trim or strip wallbox wires to the length indicated by the strip gauge on the back of the control
Push-in Terminals: Insert wires fully. NOTE: Push-in terminals are for use with 14 AWG (1.5 mm²) solid copper wire only. DO NOT use stranded or twisted wire.
OR
Screw Terminals:Tighten securely. Screw terminals are for use with
12 or 14 AWG (2.5 or 1.5 mm²) solid copper wire only. DO NOT use stranded or twisted wire.
Connect Control(s).
12
For installations involving more than one control in a wallbox, refer to Multigang Installations before beginning.
Only one Wall Control (MA-LFQ35M) can be used with up to 2 Accessory Controls (MA-ALFQ35).
12a - Single-Location control
Wall Control
Brass screws
Black screw
Green wire
Reference Wiring Diagram
Wall Control
Ground
Wiring the Wall Control (MA-LFQ35M):
Connect either of the wires removed from the switch to the black screw terminal on the Wall Control.
Connect the remaining wire removed from the switch to one of the brass screw terminals on the Wall Control.
Tighten the remaining brass screw terminal on the Wall Control. It is not used in a single-pole circuit.
Use wire connectors to connect the green ground wire on the Wall Control to the bare copper or green ground wire in the wallbox (see Important Note 3), and to cap any unused wires.
12c - Three-Location control
One location will be replaced with a Wall Control (MA-LFQ35M) and the other two with Accessory Controls (MA-ALFQ35).
Wall Control or
Accessory Control
Green wire
Tagged wires
Ground
Brass screws
Black screw
Reference Wiring Diagram
Wall Control or
Accessory Control
Br ssarBssa Brass
Live
Black
120 V~
60 Hz
13
Green
Ground
Wallbox
Mount Control(s) to wallbox.
Form wires carefully into the wallbox, mount and align the Control(s).
Install wallplate(s).
Wall Control or
Accessory Control
Brass Brass
Black
Green
Wallbox
Ground
Replace the 4-way switch Note: 4-way switch may be replaced with either a Wall
Control or an Accessory Control
Connect both of the tagged wires removed from the 4-way switch to the black screw terminal on the Control (one wire to the screw and the other to the push-in terminal).
Connect one of the remaining wires removed from the switch to one of the brass screw terminals on the Control.
Connect the remaining wire removed from the switch to the remaining brass screw terminal on the Control.
Use wire connectors to connect the green ground wire on the Control to the bare copper or green ground wire in the wallbox (see Important Note 3), and to cap any
unused wires.
Replace the two 3-way switches
Follow Step 12b - Two-Location control.
Wall Control or
Accessory Control
Wallbox
Brass
Black
Green
Ground
Canopy Module
and Fan/Light
Fixture
Neutral
Attach canopy.
7
7a - Down Rod Bracket
Check all wire connections.
Tuck the wires into the junction box and/or canopy enclosure.
Attach the canopy enclosure to the fan mounting bracket, taking care not to pinch any wires.
To junction box
7b - Flush Mount Bracket
Check all wire connections.
Tuck the wires into the junction box and/or bracket.
Ensure wires and/or wire connectors do not come in contact with moving motor parts.
Attach the canopy enclosure to the fan mounting bracket, taking care not to pinch any wires.
To junction box
9c - Three-Location control
Three switches controlling a fan/light fixture.
Note: Screw placement may be different on your switch.
Same colored screw (or marked IN or OUT)
10
Ground (Bare Copper or Green Wire)
Tagged wires
Identify switch wires.
If two switches control the fan and light separately, tag the wires connected to the light switch.In Step 12, connect these wires to the Wall Control.
Important Note:
Your wall switch may have two wires attached to the same screw (see illustrations below for examples).Tape these two wires together before disconnecting.When wiring, connect wires to new Controls the same way they were connected to the switch.
One wire in the push-in terminal and one to the screw.
Disconnect switch wires.
11
Two switches will be 3-way and one will be a 4-way. TAG the two 3-way switches as in the Two-Location diagram above. The 4-way switch will have insulated wires connected to four screws plus a green ground screw. TAG two insulated wires which are connected to same colored screws.
One continuous wire to the screw.
Brass
Live
120 V~
60 Hz
Brass Black
Wallbox
Green
Ground
Canopy Module
and Fan/Light
Fixture
Neutral
12b - Two-Location control
One location will be replaced with a Wall Control (MA-LFQ35M) and the other with an Accessory Control (MA-ALFQ35).
Wall Control and
Accessory Control
Brass screws
Tag
Black screw
Green wire
Reference Wiring Diagram
Wall Control or
Accessory Control
Ground
Wiring the Wall Control and Accessory Control:
Connect the tagged wire removed from the switch to the blackscrew terminal on the Control.
Connect one of the remaining wires removed from the switch to one of the brass screw terminals on the Control.
Connect the remaining wire removed from the switch to the remaining brass screw terminal on the Control.
Use wire connectors to connect the green ground wire on the Control to the bare copper or green ground wire in the wallbox (see Important Note 3), and to cap any unused wires.
Wall Control or
Accessory Control
Caution: Do not overtighten
Start screws.
Turn ON power.
14
Do not turn on power until Wall Control, Accessory Control(s) and Canopy Module have been installed and wired.
Turn power ON at circuit breaker (or replace fuse).
mounting screws.
Warning: Fan will return to full speed when power is restored. Clean up any tools or ladders near the fan first.
Activate system.
15
Pull out the Front Accessible Service Switch (FASS ) at the bottom of the Wall Control, wait 10 seconds, then push it back in.
The LEDs will cycle for up to 30 seconds.
If installing more than one Wall Control/Canopy Module system,
activate one at a time with FASS pushed in on all other systems.
Accessory Controls do not require activation.
Align control and tighten screws.
Brass Brass
Live
Black
Black
120 V~
Screw Terminals: Turn screws to loosen.
Push-in Terminals: Insert screwdriver. Pull wire out.
Looped Wire: Turn screw to loosen.
60 Hz
Wallbox
Green
Ground
Brass Brass
Black
Wallbox
Green
Ground
Canopy Module
and Fan/Light
Fixture
Neutral
Recommended - Disconnect pull chains.
16
Disconnect pull chain extensions to prevent light and fan speeds from being adjusted at the fan.
Loading...