HomeWorks LQSE-4A5-120-DPRO LED+ Phase Adaptive Power Module
1
3691126b 1 05.08.20
PRO LED+ Phase Adaptive Power Module
The DIN Power Module (DPM) family is a group of
modular products for the control of lighting loads and
motor loads.
This document describes the following product:
LQSE-4A5-120-D: 4-Zone DIN Power Module
for phase control dimming
of lighting loads
Features
• PRO LED+ Phase Adaptive Power Modules can be used
in a HomeWorks system using a QSX processor.
• Includes QS link for seamless integration of lights and
controls.
• An auto-detect mode is available to detect and
configure forward-phase or reverse-phase dimming for
incandescent / halogen, electronic / magnetic low-voltage
and neon / cold cathode light sources.
• A locked forward-phase or reverse-phase mode
is available.
• Controls dimmable LED loads. Refer to
www.lutron.com/ledtool for compatibility with dimmable
LED light sources.
• NEMA SSL 7A-2015 compliant for compatibility with
solid state lighting.
• RTISS technology compensates for incoming linevoltage variations such as changes in Root Mean Square
(RMS) voltage, frequency shifts (up to ± 2% change in
frequency /second), harmonics and line noise.
• RTISS-TE technology allows for true instantaneous
voltage compensation for incoming line-voltage
variations. Only operates in reverse-phase when
"voltage-comp." is enabled.
• RTISS-ICM technology is able to withstand high-inrush
LEDs, bulb blowouts, and direct shorts
• Provides air gap off (when all zones are off).
• Integral protection for common temporary over-current
and over-voltage conditions.
LQ SE- 4A5 -120 -D
• LEDs on the module provide diagnostic information.
• Buttons on the module provide override control.
• Manual Override contact closure input (CCI).
• UL
® 924 certified for use with a LUT-ELI emergency
lighting interface.
• Power failure memory automatically returns the
outputs to the levels they were set to prior to a
power outage.
SPECIFICATION SUBMITTALPage
Job Name:
Job Number:
Model Numbers:
®
HomeWorks LQSE-4A5-120-DPRO LED+ Phase Adaptive Power Module
2
3691126b 2 05.08.20
System Example
Contact Closure Input
Adaptive Power
Module
120 V~ Control Power
800 W Adaptive load
500 W Adaptive load
500 W Adaptive load
500 W Adaptive load
HomeWorks
Palladiom
Keypad
HomeWorks
Panel
Power Module
QS Contact
Closure
Interface
GRAFIK
Eye QS
Zn 1
Zn 2Zn 3Zn 4
5 /16 in
4.4 in-lb
8 mm
•
m
0.5 N
CCI
COM
MUX
COM
MUX
0-10 V-
120 V~ 5 A ea
123
50 mA
H
Def
Opt
1
M
2
3
L
4
Input | Entrada
HomeWorks QS
Entrée
LQSE-4T5-120-D
Ta > 65 ˚C
120 V~ 50 / 60 Hz
Prog
lutron.com
HN
Up to 100
QS Link
7 mm
0,28 in
L1
+24
COML2COM
CCI
HomeWorks
HQP7-2
24-36 V- 250 mA SELV NEC® Class 2
lutron.com +1.844.LUTRON1
+44.(0)20.7702.0657
L1: 24 V- 1.0 A L2: 24 V- 1.0 A
m
0,5 N
===LED | DEL
x
TxR
•
V+
V+
4,4 in-lb
MUX
MUX
MUX
MUX
COM
COM
HomeWorks QSX
Processor
1
1
1
1
Sivoia QS
Shade / Drapery
total QS
devices
Notes:
1
See "Output Zone Ratings" in “Specifications” section, for specific load types ratings.
SPECIFICATION SUBMITTALPage
Job Name:
Model Numbers:
Job Number:
®
HomeWorks LQSE-4A5-120-DPRO LED+ Phase Adaptive Power Module
3
3691126b 3 05.08.20
Specifications
Adaptive Power Module
Power
• 120 V~ 50/60 Hz
• 16 A maximum total input current.
• Lightning strike protection meets ANSI/IEEE standard
62.31-1980. Can withstand voltage surges of up to
6000 V and current surges of up to 3000 A.
• Contact Lutron for ungrounded delta feed applications.
Regulatory Approvals
• Lutron Quality Systems registered to ISO 9001.2015
• cULus Listed
• NOM Certified
• ICES-5( B) / NMB-5(B)
• FCC Class B
® 924
• UL
• NEMA SSL 7A-2015
Environment
• See Mounting on page 6 for thermal specifications.
• Relative humidity: less than 90% non-condensing.
• For indoor use only.
Output Zone Ratings
• Each zone has no minimum load requirement.
• When programmed to "auto detect" mode, the unit
starts in reverse-phase and if an incompatible load is
detected, it will convert to forward-phase.
• Internal relay provides an air gap off when all zones
are off.
• One load type per zone.
• Output must not be used to control receptacles. If
controlling plug-in lamps, installation must ensure a
method of preventing non-rated loads being plugged
into the unit. An example is a dedicated receptacle
with an alternate plug load such as a Duplex Dimming
Receptacle (NTR-15-DDTR-WH) and Dimming Lamp
Plug (RP-FDU-10-).
• Output must be directly connected to the load.
• Output breakers or switches must not be used.
• Run a separate neutral for each load circuit.
A common neutral connection is not recommended.
• Unit may be powered by Ground Fault Circuit
Interrupter (GFCI) or Arc Fault Circuit Interrupter (AFCI)
if required. If using a GFCI or an AFCI incorporating
GFCI protection, maximum wire length between the
power module and the load must be less than
100 ft (30 m). Load circuit wiring (from breaker to unit
to load) must be run in its own non-metallic conduit, or
nuisance tripping may occur.
• For applications requiring 0–10 V- control, use Ten
Volt Interface (GRX-TVI) or the LQSE-4T5-120-D.
• For applications requiring higher wattage ratings, use a
power booster (PHPM-PA-120-WH).
• For dimmable loads only. For applications requiring
switching control, use a PHPM-SW-DV-WH interface
or the LQSE-4S8-120-D.
• Works up to the output current rating with all
dimmable LED drivers whose inrush current does
not exceed NEMA410 standards for electronic
ballast / driver.
SPECIFICATION SUBMITTALPage
Job Name:
Job Number:
Model Numbers:
®
HomeWorks LQSE-4A5-120-DPRO LED+ Phase Adaptive Power Module
4
3691126b 4 05.08.20
Specifications (continued)
Output Zone Ratings (continued)
• No Derating is required when using a Lutron panel. See Lutron Specification Submittals 3691055 or 3691106 at
www.lutron.com
No Derating is required if all the conditions below are met:
•
– Calibration point maximum is 158 ºF (70 ºC)
– Room ambient temperature is between 32 ºF and 86 ºF (0 ºC and 30 ºC)
– Panel ambient temperature is between 32 ºF and 122 ºF (0 ºC and 50 ºC)
• 100 W Derating is required on all zones for a single module in a single non-ventilated DIN enclosure if:
– The room ambient temperature is between 86 ºF and 104 ºF (30 ºC and 40 ºC)
• 200 W Derating is required on all zones for multiple row non-ventilated DIN enclosure if:
–
The room ambient temperature is between 86 ºF and 104 ºF (30 ºC and 40 ºC)
A, B
Each zone is rated for the following wattage and load types
Zone 1 Rating Zone 2, 3 and 4 Rating (per zone)
Load Type
No Derating
LED (reverse-phase)
Lutron Hi-lume A-series LTE
LED SSL7A-2015 (forward-phase) E400 W400 W400 W200 W200 W200 W
Incandescent / Halogen, ELV800 W700 W600 W500 W400 W300 W
Neon / Co ld Cathode, MLV
B
F
D
6.6 A5.8 A5 A4.2 A3.3 A2.5 A
4.0 A (20 drivers
maximum)
800 VA (525 WC)700 VA (525 WC)600 VA (450 WC)500 VA (375 WC)400 VA (300 WC)300 VA (225 WC)
100 W
Derating
3.2 A (20 drivers
maximum)
200 W
DeratingNo Derating
2.4 A (20 drivers
maximum)
:
3.0 A (13 drivers
maximum)
100 W
Derating
2.2 A (13 drivers
maximum)
200 W
Derating
1.4 A (13 drivers
maximum)
A
Additional load type options are available in the HomeWorks software suite, some may require an interface. Contact Lutron for details.
B Works with all dimmable LED drivers whose inrush current does not exceed NEMA410 standards for electronic ballast/drivers. Refer to
www.lutron.com/ledtool for specific LED compatibility information and recommended LED light sources.
C Actual lamp wattage.
D
Only use iron core transformers intended for use with an electronic switch or dimmer per Clause 8.3 of IEC / EN 60669-2-1.
E
Complies with SSL7A-2015 when configured in the HomeWorks software suite to LED forward phase with low-end trim set to 10% and high-end trim set
to 90%.
F
Load type must be set to "Hi-lume 1% 2-Wire LTE LED", with low-end trim = 32% and high-end trim = 78%. Setting the proper trim and load type is
necessary to ensure optimal performance and 1% dimming capability.
SPECIFICATION SUBMITTALPage