Lumiscope 2214 User Manual

Fast Read
y
Dual Scale Digital Thermometer
With Soft Flexible Tip
Please read carefully before using ID# ACT05/03
________________________________________________________________ FEATURES
The Lumiscope 2214 Fast Read Dual Scale Digital Thermometer with Soft Flexible Tip accuratel measures temperature 6 times quicker then most digital thermometers. The compact, lightweight design is durable and waterproof and features an easy-to-read display-ideal for use by the whole family.
________________________________________________________________ PARTS DESCRIPTION
Display Window
Flexible Probe
________________________________________________________________ CHANGING FROM ºC TO ºF
To change from ºC to ºF or vice versa-while the thermometer is OFF, press the on/off button once then immediately press and hold the on/off button again until the mode changes.
________________________________________________________________ HOW TO USE
To ensure an accurate temperature reading, avoid eating, drinking any liquids, exercising, bathing or smoking for 15 minutes before taking a measurement.
1. Disinfect the thermometer probe with ethyl (rubbing) alcohol. Place a probe cover over the tip of the thermometer. Press the on/off button. The display will show (or ) followed by . If appears instead, the thermometer has malfunctioned and must be repaired or replaced.
2. The display will now read (or ) with a blinking ºF (or ºC) and the unit is now ready for measurement. Place the probe in the desired measurement location (oral, under arm, rectal).
3. Once the ºF (or ºC) has stopped blinking, the peak temperature has been reached and a beeper will sound for approx. 4 seconds.
4. After reading the measurement, turn the thermometer off, dispose of the used probe cover and clean the thermometer. If the thermometer is accidentally left on, it will automatically shut off after 10 minutes.
5. Children should always be supervised by an adult during the measurement process. After use, the thermometer should be stored in a safe place, out of the reach of children.
NOTE: If the measured temperature is higher or lower than the thermometer’s measuring range, the
display will read (or ) or (or ).
NOTE: Using a probe cover may result in a 0.2ºF (0.1ºC) difference from actual temperature.
________________________________________________________________ RELIABLE METHODS TO MEASURE TEMPERATURE
ORAL USE (approx. 10-20 seconds) Place the probe tip well under the tongue. The mouth should remain closed during measurement to ensure an accurate temperature reading. Do not bend or bite the probe while it is in the mouth. A normal temperature by this method is 98.6ºF (37ºC).
UNDER ARM USE (approx. 15-25 seconds) Wipe the armpit with a dry towel. Place the probe tip under the armpit and keep the arm firmly pressed against the body during measurement to ensure an accurate temperature reading. A normal temperature by this method is 97.6ºF (36.7ºC).
RECTAL USE (approx. 10-15 seconds) If your doctor recommends a rectal temperature, place a probe cover over the tip of the thermometer and lubricate the probe with a water-soluble jelly for easier insertion. Do not use petroleum jelly. Gently insert the tip of the probe NO MORE than 1/2 inch into the rectum. STOP if you meet any resistance. Hold the thermometer in place during measurement to ensure an accurate temperature reading. A normal temperature by this method is 99.6ºF (37.6ºC).
REMEMBER: Temperature readings vary from person to person and thermometer to thermometer. Find your normal temperature and watch for changes. If you compare readings between two thermometers, it is possible to have two different readings even if both thermometers are within their accuracy ranges.
Battery Cover
On/Off Button
Fast Read
Dual Scale Digital Thermometer
With Soft Flexible Tip
________________________________________________________________ LAST TEMPERATURE RECALL
While the thermometer is OFF, press and hold the on/off button for approx. 2 seconds. The last temperature measured will be displayed along with the letter “M” under the degree (º) sign.
_______________________________________________________________ CLEANING INSTRUCTIONS
Clean the thermometer by washing with soap and warm water or rubbing alcohol. Do not use thinners or chemical solvents to clean. Wipe dry with a soft cloth. Do not boil or clean the probe in the dishwasher, this will cause the unit to malfunction and will void the warranty.
________________________________________________________________ BATTERY REPLACEMENT
1. When the symbol appears the battery needs to be replaced.
2. Slide the battery cover off in the direction shown. Use a toothpick or insulated probe to remove the battery. Do not use any kind of sharp metal object to remove the battery.
3. Place a new 1.5V battery in the chamber. Insert the battery with the positive (-) side up and the negative (+) side down (facing the LCD display).
4. Slide the battery cover back onto the unit and make sure it is secure.
WARNING: Dispose of old battery properly, out of the reach of children. Swallowing the battery may be
________________________________________________________________ PRECAUTIONS
1. Prolonged high fever requires medical attention especially for young children. Contact your physician.
2. Do not drop the unit or expose to heavy shock. The unit is not shock proof.
3. Do not store the unit in direct sunlight, high temperatures, high humidity or dusty areas.
4. Do not use the thermometer if it operates erratically or if the display malfunctions.
5. Keep out of the reach of children.
6. Clean the thermometer probe before storing.
7. Do not attempt to disassemble the unit except to replace the battery.
8. If the thermometer has been stored in below-freezing temperatures, allow the thermometer to warm
________________________________________________________________ SPECIFICATIONS
Measuring Range: 90.0ºF ~ 111.9ºF (32.0ºC ~ 43.9ºC) Accuracy: ±0.2ºF (±0.1ºC) Power Supply: 1 Button Battery 1.5V, LR41, AG3 or similar Weight/Dimensions: appox. 13g / 133.5mm x 22mm x 11.5mm Ambient Operating Temperature: 50ºF ~113ºF (10ºC ~ 45ºC) Safe-Test Alarm / Multi-Recalled Memory / Beeper
_____________________________________________________________________________________
Distributed by
fatal. If the battery is swallowed, contact hospital immediately to have it removed. Do not dispose of the battery in a fire, it may explode.
naturally to room temperature before using.
3
2
1
4
5
Lumiscope
www.lumiscope.net
1-800-672-8293
Made and Printed in China