![](/html/9b/9bdb/9bdbe93f5be1a4a6e96284bbb47d6d114c7d82142efd440bda021ce75107b341/bg1.png)
Fast Read
Digital Thermometer
INSTRUCTIONS FOR USE MODEL 2210
Please read carefully before using ID# ACT01/04
______________________________________________________
FEATURES
The Lumiscope 2210 Fast Read Digital Thermometer accurately measures temperature 6 times quicker then most digital
thermometers. The compact, lightweight design is durable and waterproof and features an easy-to-read display-ideal for use by
the whole family.
__________________________________________________________
PARTS DESCRIPTION
Display Window
Probe
On/Off Button
Battery Cover
________________________________________________________
HOW TO USE
To ensure an accurate temperature reading, avoid eating, drinking any liquids, exercising, bathing or smoking for 15 minutes
before taking a measurement.
1. Disinfect the thermometer probe with ethyl (rubbing) alcohol. Place a probe cover over the tip of the thermometer. Press the
on/off button. The display will show 188.8ºF followed by “ok”. If “Err” appears instead, the thermometer has malfunctioned
and must be repaired or replaced.
2. The display will now read Lo with a blinking ºF and the unit is now ready for measurement. Place the probe in the desired
measurement location (oral, under arm, rectal).
3. Once the ºF has stopped blinking, the peak temperature has been reached.
4. After reading the measurement, turn the thermometer off, dispose of the used probe cover and clean the thermometer. If the
thermometer is accidentally left on, it will automatically shut off after 10 minutes.
5. Children should always be supervised by an adult during the measurement process. After use, the thermometer should be
stored in a safe place, out of the reach of children.
NOTE: If the measured temperature is higher or lower then the thermometer’s measuring range, the display will read HiºF or Loº.
NOTE: Using a probe cover may result in a 0.2 ºF difference from actual temperature.
________________________________________________________
RELIABLE METHODS TO MEASURE TEMPERATURE
ORAL USE (approx. 10-20 seconds)
Place the probe tip well under the tongue. The mouth should remain closed during measurement to ensure an accurate
temperature reading. Do not bend or bite the probe while it is in the mouth. A normal temperature by this method is 98.6ºF.
UNDER ARM USE (approx. 15-25 seconds)
Wipe the armpit with a dry towel. Place the probe tip under the armpit and keep the arm firmly pressed against the body during
measurement to ensure an accurate temperature reading. A normal temperature by this method is 97.6ºF.
RECTAL USE (approx. 10-15 seconds)
If your doctor recommends a rectal temperature, place a probe cover over the tip of the thermometer and lubricate the probe with
a water-soluble jelly for easier insertion. Do not use petroleum jelly. Gently insert the tip of the probe NO MORE than 1/2 inch
into the rectum. STOP if you meet any resistance. Hold the thermometer in place during measurement to ensure an accurate
temperature reading. A normal temperature by this method is 99.6ºF.
REMEMBER: Temperature readings vary from person to person and thermometer to thermometer. Find your normal
temperature and watch for changes. If you compare readings between two thermometers, it is possible to have two different
readings even if both thermometers are within their accuracy ranges.
______________________________________________________
LAST TEMPERATURE RECALL
While the thermometer is OFF, press and hold the on/off button for approx. 2 seconds. The last temperature measured will be
displayed along with the letter “M” under the degree (º) sign for approx. 3 seconds.
______________________________________________________
CLEANING INSTRUCTIONS
Clean the thermometer by washing with soap and warm water or rubbing alcohol. Do not use thinners or chemical solvents to
clean. Wipe dry with a soft cloth. Do not boil or clean the probe in the dishwasher, this will cause the unit to malfunction and will
void the warranty.
3
4
2
1
5
__________________________________________________________
BATTERY REPLACEMENT
1. When the “ ” symbol appears, the battery needs to be replaced.
2. Slide the battery cover off in the direction shown. Use a toothpick or insulated probe to remove the battery. Do not use any
kind of sharp metal object to remove the battery.
3. Place a new 1.5Vbattery in the chamber. Insert the battery with the positive (+) side down and the negative (-) side up (facing
the LCD display).
4. Slide the battery cover back onto the unit and make sure it is secure.
WARNING: Dispose of old battery properly, out of the reach of children. Swallowing the battery may be fatal. If the battery is
swallowed, contact hospital immediately to have it removed. Do not dispose of the battery in a fire, it may explode.
![](/html/9b/9bdb/9bdbe93f5be1a4a6e96284bbb47d6d114c7d82142efd440bda021ce75107b341/bg2.png)
Fast Read
Digital Thermometer
INSTRUCTIONS FOR USE MODEL 2210
__________________________________________________________
PRECAUTIONS
1. Prolonged high fever requires medical attention especially for young children. Contact your physician.
2. Do not drop the unit or expose to heavy shock. The unit is not shock proof.
3. Do not store the unit in direct sunlight, high temperatures, high humidity or dusty areas.
4. Do not use the thermometer if it operates erratically or if the display malfunctions.
5. Keep out of the reach of children.
6. Clean the thermometer probe before storing.
7. Do not attempt to disassemble the unit except to replace the battery.
8. If the thermometer has been stored in below-freezing temperatures, allow the thermometer to warm naturally to room
temperature before using.
__________________________________________________________
SPECIFICATIONS
Measuring Range: 78.0ºF~ 111.9ºF
90.0ºF~ 111.9ºF
Accuracy: ±0.2ºF
Power Supply: 1 Button Battery 1.5V, LR41, AG3 or similar
Weight/Dimensions: appox. 12g / 130mm x 21.8mm x 12.3mm
Ambient Operating Temp. 50ºF~113ºF
Safe-Test Alarm/Memory/Beeper
__________________________________________________________
Distibuted by
The Lumiscope Co., Inc.
www.lumiscope.net
1-800-672-8293