Lumiscope 1092 User Manual

Blood Pressure Monitor
Instruction Manual
2
Model Number 1092
ID #06/00
YEAR
LIMITED W
ARRANTY
TABLE OF CONTENTS
Identification of Parts
Battery Installation/Replacement
Attaching the Wrist Cuff and Posture During . . . . . . . . . . . . . . . 4
Measurement
Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Subsequent Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Automatic Power-off Function
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
. . . . . . . . . . . . . . . . . . . . . . . . 4
. . . . . . . . . . . . . . . . . . . . . . . . . . 6
Memory Recall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Memory Clear Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Description of Display Marks . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Warranty . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . 10
Identification of Parts
ts
3
4
Battery Installation/Replacement
To use the unit, you must install batteries.
Open battery cover as illustrated. Install or replace two new batteries, making
sure the polarities (+ and -) on the battery match the polarities on the case.
• Replace battery cover.
• If the Low Battery indicator “ “ appears on the display, both batteries must be replaced.
“AAA” alkaline batteries or equivalent are suit­able for this blood pressure meter.
Attaching the Wrist Cuff and Posture During Measurement
• The blood pressure is measured at the wrist. Therefore, rolling up the sleeve is no longer necessary.
Wrap the wrist cuf
f around your left wrist with
the display panel on the inside of the wrist.
Pull the wrist cuff to fit wrist size and fasten velcro.
Wrist circumference: 5.4-7.8 in.
Rest left elbow on a table so that the cuff is at heart level. Relax the lower arm across the table and remain still. Perform measurements in either a seated or reclining posture with the left palm turned upward.
1/2 inch
Measurement
NOTE: Unit measures on inflation.
To start the measurement
Press the “Power/Start” switch.
The heart symbol will flash and the buzzer will
sound for 1 second. When the unit completes the preparations for measurement, the buzzer will sound three more times.
If batteries are weak, “” mark will not appear.
Pr
essurization and measuring begin.
When a pulse is detected, the pressure value
moves to the lower side of the display
. At this time
the “” mark flashes and buzzer beeps.
Once the blood-pressure measurement has stabi-
lized, pressurization is discontinued and the air in the cuff is automatically let out.
• The buzzer sounds for about 2 seconds, and the
high and low blood pressure are r
espectively dis
-
5
played one above the other.
Unless an error is generated, the measurement results are automatically stored in memory (Up to 7 sets of results can be stored ). When there are already 7 sets of results in memory, the oldest one is automatically erased and overwritten with the newest.
Blood pressure values and pulse rate are alternately displayed. The unit will continue to display the measurement until power is turned off.
Turn Power off Press the “Power/Start” switch to turn off.
NOTE: To discontinue a measurement for any reason, press the
“Power/Start” switch. This causes the “wrist cuff” to rapidly deflate.
Automatic Power OFF Function
If the unit is left on after measurement, an “Automatic Power­OFF Function” turns the power off after approximately 3 minutes. To continue with another measurement press the “Power/Start” switch to turn the unit on.
6
Subsequent Measurement
When a measurement needs to be made again, the time
between 2 measur
ements must be at least 10 minutes.
Memory Recall
You can r
ecall stored data by pressing the “Memory Recall” switch at any time, EXCEPT while taking a measurement.
Up to 7 sets of measurement results can be stored in memory. Memory cell No. 1 is always used to store the newest set of results.
When pressing the “Memory Recall” switch, the memory cell number is displayed. The stor
ed measurement results (systolic/diastolic blood pres­sure) are then displayed.
If the “Memory Recall” switch is pr
essed again, the prior measurements are displayed in the order they were taken.
Memory Clear Function
While the memory data to be cleared is indicated and the “Memory recall” switch is pressed for 3 seconds, the buzzer will beep and the memory data is clear
ed.
7
8
Description of Display Marks
Pulse could not be measured.
Repeat the measure­ment without moving the arm.
DISPLAY MARK CONDITION/CAUSE
CORRECTIVE ACTION
Pulse could not be measured accurately.
The cuff was inflated to more than 280 mmHg.
Pressurization is not pos­sible. The wrist cuff was not wrapped properly.
Exhaust the air from the cuff.
The arm moved during measurement.
Batteries are weak.
There is a problem with the device.
There is a problem with the unit.
After rewrapping the cuff, repeat measure­ment.
After rewrapping the cuff, conduct the measurement without moving.
Repeat the measure­ment without moving the arm.
Replace the batteries.
Return to Lumiscope service Department.
Return to Lumiscope
Service Department.
9
Switch Inflation Exhaust Rated Voltage Power Source Power Consumption Battery Life Automatic Power-Off Memory Function Dimension Weight
LCD
LCD Indication
Accuracy
Operating Environment Storage Environment
Temperatur
e
Humidity
T
emperature
Humidity
Measurement Range
Measuring Principle Measurement Localization Cuff Wrist Circumference Range
Model No.
1092
View Size Digit Size
Marks
Systolic blood pressure: 3 digits Diastolic blood pressure:
3 digits
Pulse rate: 3 digits
Measuring Battery
1.44(H) x .904(W)in (36(H) x 22.6(W)mm) .44(H) x .22(W)in (11(H) x 5.5(W)mm) Power/Start switch, Memory recall switch Automatic Inflation by Internal Pump Electromagnetic Valve 3 VDC 2 “AAA” Size Batteries
1.0W Approx. 400 times (180mmHg, 1time/day, 22°C) Approx. 3 min. Seven Memories Function
2.8(H) x 2.68(W) x 1.16(T)in (70(H) x 67(W) x 29(T)mm) Approx. 3.5 oz. (100g) 50 to 104°F (10 to 40°C) 30 to 85%RH
-4 to 140°F (-20 to 60°C) 10 to 95%RH
Pressure Pulse Pressure Pulse Pressure Pulse Rate
Oscillometric Method Left Wrist Soft Cuff
5.4 to 7.8 in. (13.5 to 19.5cm) 0 to 280 mmHg 40 to 180 Pulses/min. ±3 mmHg ±5% of r
eading
Alternatively
Specifications
CAUTION:
1. Measurement of blood pressure may not be possible for someone with a weak pulse or cardiac arrhythmia.
2. This product is not intended to be used in the diagnosis or treatment of disease.
3. If you have high blood pressure and/or other cardiovascular conditions or diseases, this device should be used in consultation with your doctor
.
4. Consult your doctor if you have questions about your blood pressure or pulse.
5. Specifications are subject to change without notice due to impr
ovements in performance.