READ THESE INSTRUCTIONS
THOROUGHLY BEFORE
INSTALLATION KEEP THESE
INSTRUCTIONS FOR
FUTURE REFERENCE.
IMPORTANT:
This product must be installed
by a qualifi ed electrician or
competent person, and in
accordance with current building
and IET wiring regulations.
BOX CONTENTS
This lighting xture has been properly
packed to avoid damage during
transit. Before commencing with the
installation carefully inspect the
luminaire to con rm there is no
damage. DO NOT INSTALL if any
damage has occurred to the xture
or any of its components:
• Light Fitting
• Instruction Manual
• LED Driver
TOOLS REQUIRED
• Screwdriver
Wraysbury
600 x 600
Panel
1
NL
LIVE = Brown
NEUTRAL = Blue
4
INSTALLATION INSTRUCTIONS
on
off
2
CAUTION
Do not hot plug when live.
5
IP40
3
36W Panel
50,000
120º
3000K 4000K 6000K
on
off
Flicker
Free
Hours
Wraysbury
5 YR
Warranty
PLEASE READ THESE INSTRUCTIONS
BEFORE INSTALLATION.
WARNING: Risk of electric shock! Isolate
the mains power before proceeding.
• Turn off the mains power before performing
inspections, installation, or removal
• Verify that the supply voltage is correct by
comparing it with the luminaire label information
• It is the installers responsibility to ensure installation
is suitable for the total load of the luminaire(s). The
supply cable, fuses/circuit brakers must be correctly
rated for the electrical load and considering for any
transient inrush currents that may occur
• Do not perform insulation strength or resistance
tests on installed luminarie(s) connected
1. Using a suitable terminal connector or
junction box, connect the LED driver to the
mains supply as shown
2. Connect the LED driver to the panel using the
Twist-N-Lock jack connector
3. CCT models only: Select the desired colour
temperature using the in-line switch
4. Fit the panel into desired location
5. Re-connect the mains supply
Panel
• Cable
Manby Business Park, Manby, Lincolnshire, LN11 8UT
Lumineux is a B&T Associates Ltd company.
Technical Helpline: +44 (0)1507 328031
www.lumineux.co.uk

DISPOSAL
The light source of this unit is not
replaceable; when the light source
reaches its end of life the whole
luminaire shall be replaced.
Disposal of Electronic Equipment
WEEE Directive 2002/96/EC This
product falls within the scope of
the Waste Electrical & Electronic
Equipment Directive (WEEE), which
means the product should not be
disposed of as normal household
waste. Please recycle where
facilities exist or check with your
Local Authority.
RoHS – All components and
materials used in this product are
RoHS 2002/95/EC compliant.
Specications may change from
time to time. The information
contained in this leaet is for
guidance only and should not be
considered as always accurate
and should be treated as
not representative.
WARRANTY
This luminaire is warranted for a
period of 5 years from the date of
purchase. The backup battery
pack in the emergency version
is warranted for a period of 12
months. The warranty could be
invalidated should the light tting
not be installed according to these
instructions, outside the scope of
the specication or the product
has been altered or tampered with
in any way. Please see website for
terms and conditions.
PRODUCT TEMP SPECIFICATION
Standard 0 to +40ºC
Emergency 0 to +30ºC
Wraysbury 600 x 600 Panel
WRAYSBURY DIMENSIONS
Part No. Description Watts L (mm) W (mm) D (mm)
430057 Wraysbury 600x600 TP(b) 36W 595 595 38
430059 Wraysbury 600x600 TP(b) 36W 595 595 38
430115
Wraysbury 600x600
TP(a) 3CCT
36W 595 595 38
L (mm)
Installation Engineers Contact Details: Luminaire Reference / Location
Name:
Luminaire Details: Full Recharge Duration 24 Hours Emergency Duration 3 Hours Lamp Type LED
Tel:
ROUTINE TEST RECORD
Type Test
Signed Date Signed Date Signed Date Signed Date Signed Date
Functional 1
Functional 2
Functional 3
Functional 4
Functional 5
Functional 6
Functional 7
Functional 8
Functional 9
Functional 10
Functional 11
3hr Duration 12
Year 1 Year 2 Year 3 Year 4 Year 5
D (mm)W (mm)
Wiring instructions for units equipped
an with EMERGENCY function
Emergency lighting luminaries must be installed and
maintained in accordance with the emergency lighting
standard BS 5266-1
1. The installation of an emergency tting MUST BE
CONNECTED AS SHOWN in diagrams below.
2. For the emergency unit to operate correctly the permanent
live feed must not be interrupted. Note: Ensure no lighting
controls are on the permanent Live feed, such as PIR’s or
SWITCHES, failing to observe this will reduce the batteries
lifetime of the emergency pack considerably.
3. After switching on an emergency equipped unit, the LED
indicator should illuminate this is to indicate battery
charging.
4. Should power to an emergency equipped unit be
disrupted or isolated, the indicating LED will switch off,
triggering the emergency function illuminating the LED’s
5. The backup battery must be charged for 24 hours before
a full duration test.
Light
Light
If the LED Driver & Downlight jack leads do not match the gender as in
diagram, please use provided gender changing leads to correct.
Revision 2
Technical Helpline: +44 (0)1507 328031