LIGHTS & POWER: (Note all lights fixtures to be wired in series)
1) Identify dry, non-plenum location for IPC. Determine location & orientation of IPC and Break-Out
Modules. Note: Vertical orientation of IPC is best for cooling. Make sure Analog zone inputs are visible and accessible. See page 6 of IPC specifications for optional acceptable orientations.
2) Run wires from the Break-Out Module locations directly to the fixture locations.
3) Mount IPC to board w/ #8 screws or self-tapping screws or in an approved enclosure. Use approved
plenum enclosure if unit is located in plenum.
4) With typical 115Vac input, IPC consumes 2.7 amps. Standard 15 amp breaker can accommodate up
to 4 IPCs and a 20 amp breaker can accommodate up to 5 IPCs. If wiring only 4 or 5 IPCs, consider powering from two separate circuits for redundancy. Note: 115Vac = 2.7 Amps, 240 Vac = 1.1 A & 227 Vac = 1.0 A.
5) Provide service disconnect switch for IPCs if not in close proximity to electrical panel or as required
per code.
6) Provide line-voltage power to IPC and wire as specified on page 7 of IPC installation manual.
(Black to Line, White to Neutral & Green to Ground.)
7) Select Master control or up to 4 zones of analog control. See Analog switch option diagrams.
8) Wire class 2 IPC wires to Break-Out Modules. See Detail B4.09, B4.12, B6.09 or B6.12. (Black is
always Negative.)
9) Wire fixture home runs to the Break-Out Modules. See Detail B4.09, B4.12, B6.09 or B6.12.
(Black is always Negative.)
10) Wire fixtures in series. Wire only two fixtures per channel, typ. See Detail A1 for wiring fixtures in
series.
11) If not using Master zone control, track which fixtures are on which zones on a plan or chart.
Note: For complete and more technical installation instructions refer to the LumaStream Intelligent Power Center Application and Installation Manual included with each unit.
LumaStream.com 2887 22nd Avenue N, Suite D, St. Petersburg, FL 33713 727.827.2805
Rev. - 09.30.12
18/2 MULTICONDUCTOR CABLE
B6
BREAKOUT
MODULE
B3
BREAKOUT
MODULE
B3
BREAKOUT
MODULE
LED LED LED LED LED LED
LED LED LED LED LED LED
LED LED LED LED LED LED
LED LED LED LED LED LED
ZONE4
ZONE3
ZONE2
ZONE1
Low voltage toggle switches and/or 0-10V analog dimmers
VIOLET
VIOLET
GR AY GR AY GR AY GR AY
ZONE 4ZONE 3ZONE 2ZONE 1
Note: For the UP position to be ON, toggle switches must be installed upside down. When switch is closed, LED’s are OFF.
24 LED FIXTURES
AC MAINS
GROUND (GREEN) NEUT (WHITE) LINE (BLACK)
TITLE:
INDEPENDENT ZONE CONTROL USING
SWITCHES AND/OR 0-10V DIMMERS
WIR-ANA-001
REV:DWG #:
B
VIOLET GR AY
0-10V dimmer Leviton # IP710-DLZ Hunt # PS-LED-010
LINE (BLACK)
AC MAINS
GROUND (GREEN) NEUT (WHITE) LINE (BLACK)
TITLE:
MASTER ZONE CONTROL USING
0-10V DIMMER & ON/OFF SWITCH
WIR-ANA-002
REV:DWG #:
B
VIOLET
GR AYVIOLET
1 Common
2 Travelers (Brass Screws)
1
GR AY
3-WAY LOW VOLTAGE
TOGGLE SWITCH
1
2
ZONE 1&2
LOW VOLTAGE TOGGLE
SWITCH OR 0-10V DIMMER
2
TITLE:
MULTIPLE ZONE CONTROL USING
TOGGLE SWITCH OR 0-10V DIMMER
WIR-ANA-003
REV:DWG #:
B
TRINITY #1 TRINITY #2 TRINITY #3 ETC.
VIOLET
GR AY
LOW VOLTAGE TOGGLE SWITCH
AND/OR 0-10V DIMMER
TITLE:
MULTIPLE TRINITY MASTER CONTROL
USING TOGGLE SWITCH AND/OR 0-10V DIMMER
REV:DWG #:
WIR-ANA-004
B
4 Inch Recessed New
3. Remove Junction Box cover.
Remove appropriate knock
-
out
4. Re-conne
ct LED light source to
housing
. Connect
RED to RED,
Construction LED Luminaire
Installation Instructions
OWNER/USER RESPONSIBILITIES: It is the responsibility of the contractor, installer, buyer, owner and user to install, maintain and operate this
luminaire in accordance with all applicable laws, building codes, regulations and local Electrical Safety Authority requirements. This product is only to be installed by a qualified person.
WARNING
Shut OFF power at fuse box or circuit breaker before installation.
Turn power OFF before inspection or removal of LED light source.
Installation:
1. Pull on LED Trim Ring in direction shown to remove LED light
source from housing. Flip open one lever on each Wire Lever Nut to disconnect wires.
and insert strain relief (not supplied) into hole. Flip open Wire Lever Nut. Connect Class 2 constant current source: Connect +Ve to RED. Connect –Ve to BLACK, by inserting stripped wire into Wire Lever Nut. Close lever. OBSERVE
CORRECT POLARITY. Failure to do so will damage LED light source. Replace Junction Box cover.
2. Extend bar hangers to fit between joists. Bar hanger foot aligns
with bottom of joist. Hammer pre-installed nails into joists. When installing in drywall, cut 4-1/2” hole. If necessary, adjust fixture for ceiling thickness by loosening hex screws then re­tighten.
BLACK to BLACK. OBSERVE CORRECT POLARITY. Failure to do so will damage LED light source. Compress Flat Spring Clips with fingers and insert into housing opening. Press upwards until trim ring is flush against the ceiling.
LumaStream, Inc. 2887 22nd Ave. N Saint Petersburg, FL 33713 T: 1-727-827-2805 Page 1 of 1
Disclaimer: LumaStream Inc. reserves the right to make changes without further notice to any products herein to improve reliability, function, or design. LumaStream does not assume any liability arising out of the application or use of any product described herein; neither does it convey any license under its patent rights, nor the rights of others.
info@lumastream.com
www.lumaStream.com
©2012 LumaStream, Inc.
All Rights Reserved
Doc No: 4.0 RI Installation
Revision: Feb-22-2012
4 Inch Recessed Re-Model
3. Pass junction box up into hole in ceiling
.
Retract clips into
4. Re-connect LED light source to
housing
. Connect
RED to RED,
LED Luminaire
Installation Instructions
OWNER/USER RESPONSIBILITIES: It is the responsibility of the contractor, installer, buyer, owner and user to install, maintain and operate this
luminaire in accordance with all applicable laws, building codes, regulations and local Electrical Safety Authority requirements. This product is only to be installed by a qualified person.
WARNING
Shut OFF power at fuse box or circuit breaker before installation.
Turn power OFF before inspection or removal of LED light source.
Installation:
1. Pull on LED Trim Ring in direction shown to remove LED light
source from housing. Flip open one lever on each Wire Lever Nut to disconnect wires.
housing and insert housing into ceiling. Press clips outwards to hold housing in place. To remove from ceiling, pull clips down and back into housing
2. Cut 4-3/8” hole in ceiling. Pull Class 2 wiring through hole in
ceiling. Remove Junction Box cover. Remove appropriate knock-out and insert strain relief (not supplied) into hole. Flip open Wire Lever Nut. Connect Class 2 constant current source: Connect +Ve to RED. Connect –Ve to BLACK, by inserting stripped wire into Wire Lever Nut. Close lever. OBSERVE
CORRECT POLARITY. Failure to do so will damage LED light source. Replace Junction Box cover.
BLACK to BLACK. OBSERVE CORRECT POLARITY. Failure to do so will damage LED light source. Compress Flat Spring Clips
with fingers and insert into housing opening. Press upwards until trim ring is flush against the ceiling.
LumaStream, Inc. 2887 22nd Ave. N Saint Petersburg, FL 33713 T: 1-727-827-2805 Page 1 of 1
Disclaimer: LumaStream Inc. reserves the right to make changes without further notice to any products herein to improve reliability, function, or design. LumaStream does not assume any liability arising out of the application or use of any product described herein; neither does it convey any license under its patent rights, nor the rights of others.
info@lumastream.com
www.lumaStream.com
©2012 LumaStream, Inc.
All Rights Reserved
Doc No: 4.0 RC Installation
Revision: Feb-22-2012
Loading...