Warning: The Luminaire should only be used complete with its protective shield (cover)
WARNING
To avoid potential unsafe lamp failure, the luminaire should be switched off at least once a week
If cable damaged replace with cable supplied by LUMASCAPE only.
Lumascape Lighting Industries Pty Ltd
38-44 Enterprise Street, Cleveland, QLD 4163, Australia
PO Box 1875, Cleveland D.C., QLD 4163, Australia
T 07 3286 2299
F 07 3286 6599
E sales@lumascape.com.au
W www.lumascape.com.au
DO NOT SHORTEN, INTERFERE OR DISCONNECT CABLE FROM FITTING. WARRANTY WILL BE VOID IF
CABLE ASSEMBLY IS TAMPERED WITH.
100MM
132
(3.93IN)
100-250MM
(3.93-9.84IN)
160MM
(6.3IN)
Locate Fixtures
Site fixture in proximity to cabling.
Use discretion in locating fixtures as
glass can become very hot and may
burn.
FLAT
WASHER
SPRING
WASHER
BRACKET
DOME NUT
Mount Bracket to Fixture
Mount bracket supplied to fixture using
the M10 dome nuts and washers as
shown
2 X 8MM
12MM
o
90
o
30
Mount Fixture
Mount fixture to secure surface.
Orientate fixture as required and
tighten nuts
70MM (2.75IN)
BRACKET TOP VIEW
o
90
o
30
465
Connect Supply
Connect fixture to supply cable according to
local wiring rules.
78
60
45
30
10-15 MIN.
Test Fixture
Test to ensure fixture is operational. Allow to
burn for 10-15 minutes to allow any
moisture in fixture to evaporate.
Seal Fixture
Ensure seal and sealing surface is clean.
Clean glass if necessary. Tighten lid screws
using the 3mm Allen key supplied.
Lumascape recommends tightening in the
above Torque Pattern to 2.5 - 3 N.m.
DO NOT OVER TIGHTEN.
Insert Lamp
Check lamp WATTAGE, VOLTAGE, and
TYPE, and insert into lampholder (refer to
lamp manufacturers documentation for
handling precautions).
Torque Pattern
1
6
4
3
5
2
GIMBAL
LOCKING
SCREW
GIMBAL
ROTATION
LOCKING
SCREW
Adjust Gimbal Position.
Adjust the vertical position of the gimbal to
minimise glare, and tighten locking screw.
Rotate gimbal to desired direction and
tighten locking screw.
Warning: The Luminaire should only be used complete with its protective shield (cover)
To avoid potential unsafe lamp failure, the luminaire should be switched off at least once a week
Lumascape Lighting Industries Pty Ltd
38-44 Enterprise Street, Cleveland, QLD 4163, Australia
PO Box 1875, Cleveland D.C., QLD 4163, Australia
T 07 3286 2299
F 07 3286 6599
E sales@lumascape.com.au
W www.lumascape.com.au
RELAMPING
ACB
6
6
Isolate and Open Fixture
Ensure the fixture is electrically isolated.
Loosen the screws with the Allen Key
provided. If necessary gently lever lid out
with a large screwdriver.
Replace Lamp
Remove old lamp and check condition of
lampholder. Check new lamp WATTAGE,
VOLTAGE and TYPE. Insert new
lamp,(Refer installation instruction 4 over.)
7
Adjust, Aim, Test and Seal
If necessary, readjust and re-aim gimbal
position.
Test and seal fixture as per installation
Instructions through to , over.
68
8
LAMP SOURCE CONVERSION INSTRUCTION
132
Isolate and
Open Fixture
Ensure the fixture is electrically isolated.
Loosen the screws with the Allen Key
provided. If necessary gently lever lid out
with a large screwdriver.
Remove Gimbal
Remove gimbal by loosening the locking
screw and pulling vertically.
45
GUIDE
PINS
GIMBAL
LOCKING
SCREW
GEAR
ASSEMBLY
Remove Gear Assembly
Remove gear assembly by pulling vertically
(Note: Gear assembly may be screwed to
fixture body).
6
6
6
7
8
Insert New Gear Assembly
Align holes in gear tray with Threaded
Guide Pins in base of fixture and insert
fully, fit S/S nuts to retain