Failure to isolate power
supply before installation or
maintenance may result in
fire, serious injury, electric
shock, death and may
damage the luminaire.
IP68
Warranty Void if not installed as per installation instructions and in
compliance with the local electrical code.
READ ALL SAFETY INSTRUCTIONS FIRST
› Follow instructions carefully, failure to do so will void
warranty.
› Ensure installation complies with local law and
applicable standards.
› Input voltage range 110-277V AC 50/60Hz.
› Requires Lumascape PowerSync Master LS6540 for
LUMASCAPE NORTH AMERICA 1300 Industrial Road, Unit #19, San Carlos, CA 94070, USA
Phone +1 650 595 5862 | Fax +1 650 595 5820 | Email: info@lumascape.com | www.lumacape.com
Products and specifications are subject to change without notice.
› Never make connections whilst the power is
connected.
› All connections must be kept dry; failure to do so
may result in product reliability issues.
› Ensure mains input power is surge protected.
› Do not make modifications or alter the product.
› Keep luminaire clean and free of debris.
IN0167 181126 CE UL
1 / 7
Erden
torque order
E8
LS3080
General Assembly
To prevent condensation, ensure
luminaire is acclimatized (at same
temperature as environment) before
installation.
Aiming Luminaire
B
INSTALLATION INSTRUCTIONS
INGROUND / INGRADE
LED UPLIGHT
Cover Screw(s)
Tighten in the following torque pattern to seal luminaire.
Luminaire Cover
After aiming luminaire at target seal luminaire using the cover.
Align the cover screws and the screw holes in the luminaire body
with the corresponding threaded holes in the pre-installation kit.
Be sure to tighten cover screws as per the torque pattern shown
above.
USA I Australia I Asia I Middle East I Europe
1
6
4
D
3
5
2
C
A
A
Aim Mark
Point in the direction of the target to be lit.,
B
Rotation Lock Screw
Tighten to lock gimbal rotation.
C
Tilt Adjustment Screw
Turn to adjust tilt of gimbal.
Temporary Cover
Keep on pre-instalation kit
in order to avoid concrete
and debris from entering
the cavity. Remove when
ready to installl luminaire.
Ensure all Sealing Surfaces are Clean
1
D
Luminaire Body
Slide into pre-installation kit and secure to mounting collar using
cover and cover screws.
Luminaire Cable / Hookup Wire
Terminate in accordance to local wiring rules.
Make sure to properly isolate data wire if not used.
See diagram below for conductor colour and designation.
Mounting Collar
Ensure final installation surface is completely flush with top
face of the blockout.
Mounting Brackets
Screw mounting brackets to collar to arrest any movement.
Gravel
Use gravel which allows good drainage around luminaire.
2
Ensure all sealing surfaces
are clean and free of
concrete, dirt, debris or any
3
other foreign matter. Sealing
Surfaces include.
1
Entire Rubber Lid Seal
2
Luminaire Flange
3
Luminaire Lid Uderside
Poured Concrete
Foam Plug
Use as a temporary barrier
when concrete is poured
around pre-installation kit.
Remove before installing
luminaire to allow for
adequate drainage.
LUMASCAPE NORTH AMERICA 1300 Industrial Road, Unit #19, San Carlos, CA 94070, USA
Phone +1 650 595 5862 | Fax +1 650 595 5820 | Email: info@lumascape.com | www.lumacape.com
Products and specifications are subject to change without notice.
Wiring Details
CE Color CodeUL / ETL Color Code Designation
Green / Yellow GreenEarth / Ground
Brown
Blue
Black
* Data wire must be appropriately insulated if not connected.
Operating voltage on this wire is 24 V. Incorrect wiring will
damage luminaire and void warranty. Do not Hi-Pot test.
Bootlace ferrules must be ued on all wires when
connecting in terminal blocks.
BlackActive / Live
WhiteNeutral
GreyData *
IN0167 181126 CE UL
L
N
2 / 7
Erden
E8
LS3080
Installation Preparation
WARNING
INSTALLATION INSTRUCTIONS
INGROUND / INGRADE
LED UPLIGHT
USA I Australia I Asia I Middle East I Europe
› The luminaire should only be used complete with its
protective shield (cover).
› Keep electronics free from dirt and moisture.
› Luminaires can become very hot. Use discretion in
placement.
› No power tools to be used.
Component Overview
Connection Type ‘84’
› Do not shorten or interfere with cable assembly.
› Warranty will be void if cable assembly is tampered
with.
› Do not overtighten lid screws.
› Do not apply downward force on the lid of luminaire.
LUMASCAPE NORTH AMERICA 1300 Industrial Road, Unit #19, San Carlos, CA 94070, USA
Phone +1 650 595 5862 | Fax +1 650 595 5820 | Email: info@lumascape.com | www.lumacape.com
Products and specifications are subject to change without notice.
17.7” (450 mm)
19.4” (494 mm)
3 / 7
IN0167 181126 CE UL
Erden
To Lumascape luminaire
To next
luminaire
From
PowerSync
TM
Master
Neutral - Blue
Earth - Green / Yellow
Data - Black
Line - Brown
INSTALLATION INSTRUCTIONS
E8
LS3080
INGROUND / INGRADE
LED UPLIGHT
USA I Australia I Asia I Middle East I Europe
Network Topology
LS3080 Dimming
Junction box, or
other approved
DMX In
110-240 V
50/60 Hz
110-240 V
50/60 Hz
Junction BoxJunction Box Termination
When no data injector
is in use (non-dimming
applications), isolate data
wire.
wiring device.
LS6540
PowerSync™
Data Injector
Loop to next PowerSync™
Data Injector
LS6540
PowerSync™
Data Injector
6’ (1.8 m) max
Australia | Asia | Middle East | Europe
Up to 45 luminaires per run
Max run length 492 ft (150 m).
Consult voltage drop and
run length tables for specific
limitations.
To Lumascape luminaire
For last luminaire in the
circuit, install terminating
resistor in parallel across
the data wire and earth
wire.
Neutral - Blue
Earth - Green / Yellow
Data - Black
Line - Brown
From
Master
TM
PowerSync
Trunk cable and junction box supplied by othersTrunk cable and junction box supplied by others
LUMASCAPE NORTH AMERICA 1300 Industrial Road, Unit #19, San Carlos, CA 94070, USA
Phone +1 650 595 5862 | Fax +1 650 595 5820 | Email: info@lumascape.com | www.lumacape.com
Products and specifications are subject to change without notice.
When no data injector
is in use (non-dimming
applications), isolate data
wire.
3.3kΩ / 2W
Fit 3.3kΩ, 2 Watt
terminator resistor
(LS6406) between
earth and data wires.
Two LS6406 have
been supplied with the
LS6540 PowerSync
master for this purpose.
TM
IN0167 181126 CE UL
4 / 7
Erden
INSTALLATION INSTRUCTIONS
E8
LS3080
INGROUND / INGRADE
LED UPLIGHT
USA I Australia I Asia I Middle East I Europe
Network Topology
LS3080 Dimming
Junction box, or
other approved
DMX In
120-277 V
50/60 Hz
120-277 V
50/60 Hz
Junction BoxJunction Box Termination
When no data injector
is in use (non-dimming
applications), isolate data
wire.
wiring device.
LS6540
PowerSync™
Data Injector
Loop to next PowerSync™
Data Injector
LS6540
PowerSync™
Data Injector
To Lumascape luminaire
6’ (1.8 m) max
Neutral - White
Earth - Green / Yellow
Data - Grey
Line - Black
Up to 45 luminaires per run
Max run length 492 ft (150 m).
Consult voltage drop and
run length tables for specific
limitations.
Always observe NEC branch
circuit current limitations.
To Lumascape luminaire
North America
For last luminaire in the
circuit, install terminating
resistor in parallel across
the data wire and earth
wire.
Neutral - White
Earth - Green / Yellow
Data - Grey
Line - Black
From
Master
TM
PowerSync
Trunk cable supplied by othersTrunk cable supplied by others
To next
luminaire
From
PowerSync
Master
TM
LS3080 Non-Dimming
Junction box, or
other approved
wiring device.
6’ (1.8 m) max
When no data injector
is in use (non-dimming
applications), isolate data
wire.
LUMASCAPE NORTH AMERICA 1300 Industrial Road, Unit #19, San Carlos, CA 94070, USA
Phone +1 650 595 5862 | Fax +1 650 595 5820 | Email: info@lumascape.com | www.lumacape.com
Products and specifications are subject to change without notice.
3.3kΩ / 2W
Fit 3.3kΩ, 2 Watt
terminator resistor
(LS6406) between
earth and data wires.
Two LS6406 have
been supplied with the
LS6540 PowerSync
master for this purpose.
Observe NEC branch circuit
current limitations.
TM
5 / 7
IN0167 181126 CE UL
Erden
gravel
hole
10.3”
Ø262mm
finished surface
19.4”
(494mm)
INSTALLATION INSTRUCTIONS
E8
LS3080
INGROUND / INGRADE
LED UPLIGHT
USA I Australia I Asia I Middle East I Europe
Installation
Step 1
Layout luminaire locations as required.
Use discretion in placement as
luminaire may become hot and could
burn. Luminaire cavity should be
as shown. Ensure gravel or similar
medium forms the bottom of the cavity
to allow drainage.
Note: Always check luminaire lable for
correct supply details and lamp type if
applicable.
Step 2
Position and use screws to attach
brackets at the bottom of the mounting
collar before concrete is poured.
IP68
Step 3
Fit sleeve, collar and cover plate.
• Fit sleeve and collar over foam
plug.
• Ensure enough cable is in the
cavity to connect to luminaire.
• Position top surface of the
mounting collar to be flush with
final surface level.
• Screw cover plate to mounting
collar.
• Ensure ample depth for fitting.
Step 5Step 6Step 4
Pour concrete. Check that the top
surface of the mounting collar is flush
with the finished surface level.
LUMASCAPE NORTH AMERICA 1300 Industrial Road, Unit #19, San Carlos, CA 94070, USA
Phone +1 650 595 5862 | Fax +1 650 595 5820 | Email: info@lumascape.com | www.lumacape.com
Products and specifications are subject to change without notice.
When ready to install luminaire;
• Destroy foam plug and assemble
luminaire.
• Remove cover plate, glass and
seal.
Minimum length of
cable protruding
from the ground to
be 100mm.
Factory
supplied
anti-leach
cable
Connect cable / hookup wire in
accordance with local wiring rules.
IMPORTANT: Power supply must
be isolated prior to connection or
disconnection of cables. Failure to do
so will result in damage to the luminaire
components.
6 / 7
IN0167 181126 CE UL
Erden
360°
20°
360°
20°
360°
20°
Air gap
torque order
torque order
1
2
6
5
3
4
INSTALLATION INSTRUCTIONS
E8
LS3080
INGROUND / INGRADE
LED UPLIGHT
USA I Australia I Asia I Middle East I Europe
Installation cont...
Ensure that luminaire is acclimatized.
Remove moisture sachet from packet
supplied with lid assembly, remove
gimbal from luminaire body and drop
the sachet in the base of luminaire
body.
To prevent condensation, ensure
luminaire is acclimatized (at same
temperature as environment) before
installation. Do not remove sachet
from sealed packaging at this stage.
Step 8Step 7
Rotate gimbal until Aiming Mark is
targeted as desired.
Adjust gimbal tilt angle by rotating Tilt
Adjust screw with Allen key supplied.
360°
20°
Step 10Step 11
Lay lid partially over luminaire to allow
a gap for any moisture present to
evaporate prior to sealing. Connect to
supply and allow to burn for 2 hours.
IMPORTANT: Do not energise without
partially covering gimbal.
Alternatively, using heat gun set at
100°C, heat the inside of luminaire
at a distance of 300mm away for 10
minutes.
LUMASCAPE NORTH AMERICA 1300 Industrial Road, Unit #19, San Carlos, CA 94070, USA
Phone +1 650 595 5862 | Fax +1 650 595 5820 | Email: info@lumascape.com | www.lumacape.com
Products and specifications are subject to change without notice.
2 hours
Seal immediately after de-energising.
Ensure seal and sealing surface is
clean. Clean glass if necessary. Tighten
lid screws using the 3mm allen key
supplied. Ensure seal/sealing surface
is free from debris. Lumascape
recommends tightening using the
torque pattern below.
Do not overtighten screws, 3Nm max.
1
6
4
2
3
5
7 / 7
IN0167 181126 CE UL
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.