Datasheet T7264 Datasheet (Lucent Technologies)

Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver
U-interface 2B1Q transceiver — Range over 18 kft on 26 AWG — ISDN basic-rate 2B+D — Full-duplex, 2-wire operation — 2B1Q four-level line code — Conforms to ANSI North American Standard
T1.601-1992
— Supports NT quiet mode and insertion loss test
mode for maintenance
K2 interface — 2B+D data — 512 kbits/s TDM interface — Frame and superframe markers — Embedded operations channel (eoc) — U-interface M bits and crc results — Device control and status
Other — Single +5 V (±5%) supply — –40 °C to +85 °C — 44-pin PLCC
Power consumption — Operating 275 mW typical — Idle mode 30 mW typical
Analog front end — On-chip line driver for 2.5 V pulses — On-chip balance network
— Sigma-delta A/D converter — Internal 15.36 MHz crystal oscillator — Supports 15.36 MHz external clock input
Digital signal processor — Digital timing recovery (pull range ±250 ppm) — Echo cancellation (linear and nonlinear) — Accommodates distortion from bridged taps — Scrambling/descrambling — crc calculations — Selectable LT or NT operation — Start-up sequencing with timers — Activation/deactivation support — Cold start in 3.5 seconds (typical) — Warm start in 200 ms (typical) — U-frame formatting and decoding

Description

The Lucent Technologies Microelectronics Group T7264 U-Interface 2B1Q Transceiver integrated cir­cuit provides full-duplex, basic-rate (2B+D) integrated services digital network (ISDN) communications on a 2-wire digital subscriber loop at either the LT or NT and conforms to the ANSI North American Standard T1.601-1992. The single +5 V CMOS device is pack­aged in a 44-pin plastic leaded chip carrier (PLCC).
K2
K2 BUS FORMAT, DECODE
DESCRAM.
T7264
SCRAMBLER
SIGNAL
DETECT
AGC
DFE
ECHO
CANCELER
DEC
+
DIG. PLL
2B1Q
ENCODER
A/D
Figure 1. T7264 Simplified Block Diagram
LINE
DRIVER
BALANCE
NETWORK
XTAL OSC.
2-WIRE
2B1Q
U-INTERFACE
15.36 MHz
5-5161
T7264 U-Interface 2B1Q Transceiver
Data Sheet
April 1998
Table of Contents
Contents Page
Features ..........................................................................1
Description .......................................................................1
Pin Information ................................................................3
Functional Overview.........................................................6
Device Interface and Connections....................................7
Analog Device Interface ................................................7
Power Supply Connections............................................8
Clock Operation.............................................................8
Reset Operation.............................................................8
Reset Sequences and Clock Synchronization............8
Reset Time..................................................................9
Idle Mode.....................................................................10
NT Maintenance..........................................................10
K2 Interface Description ................................................11
K2 NT and LT Timing Sources.....................................12
K2 Bits Description......................................................13
K2 Bit Levels................................................................20
U-Interface Description ..................................................21
K2 Functional Description ..............................................22
K2 Framing Bits...........................................................23
K2 eoc and Loopback Response Timing ....................24
K2 Device Status and Control Bits...............................25
The adea Bit................................................................26
The nebe, febe, rfebe, and ccrc Bits............................27
NT or LT Operation ........................................................28
Minimal Example............................................................29
Activation and the K2 Interface ......................................30
Priority .........................................................................31
Applications....................................................................32
Absolute Maximum Ratings ...........................................34
Handling Precautions.....................................................34
Recommended Operating Conditions............................34
Electrical Characteristics ...............................................35
Loop-Range Performance Characteristics .....................36
Timing Characteristics ...................................................37
Switching T est Input/Output Wav eform ..........................38
Outline Diagram .............................................................39
Ordering Information ......................................................39
Appendix A. Questions and Answers ............................40
Introduction..................................................................40
U-Interface...................................................................40
K2 Interface ................................................................46
Miscellaneous ............................................................. 49
Appendix B. Differences Between the T-7264- - -ML,
T-7264- - -ML2 and T-7264A- -ML Devices ...................53
Technology...................................................................53
Standard......................................................................53

List of Figures

Figure 1. T7264 Simplified Block Diagram .......................1
Figure 2. Pin Diagram ......................................................3
Figure 3. Quat Example ...................................................6
Figure 4. Line Interface and Protection ............................7
Figure 5. Recommended Power Supply
Connections ..................................................................8
Figure 6. RESET Figure 7. RESET
Figure 8. K2 Interface Timing .........................................11
Waveform Normal Operation ...............9
Timing for Synchronized Clocks ..........9
Contents Page
Figure 9. K2 Octets ........................................................11
Figure 10. K2 Interface LT and NT .................................12
Figure 11. K2 Interface Frame Format ...........................14
Figure 12. U-Interface Frame and Superframe ..............21
Figure 13. U-Interface Superframe Bit Groups ..............21
Figure 14. K2 Octet Description .....................................22
Figure 15. K2 Functional Description .............................22
Figure 16. K2-to-U Mapping ...........................................23
Figure 17. U-to-K2 Mapping ...........................................24
Figure 18. K2 Response Timing .....................................24
Figure 19. T7264 nebe/febe/crc Block Diagram .............28
Figure 20. Use of rfebe in a Multilink Configuration .......28
Figure 21. State Sequence for DSL Transceiver
Start-Up .......................................................................32
Figure 22. Loop Application ...........................................33
Figure 23. 2-Wire Terminal Application ..........................33
Figure 24. Digital Pair Gain Application .........................33
Figure 25. Timing Diagram Referenced to F ..................37
Figure 26. Timing Diagram Referenced to C ..................37
Figure 27. RESET
Figure 28. Switching Test Waveform ..............................38
Table 1. Pin Functions ......................................................3
Table 2. Pin Descriptions ..................................................4
Table 3. Clock Configuration ............................................6
Table 4. K2 Interface Serial Data Bit Map ......................13
Table 5. B1, B2, D, and S1 Octets (Overview) ...............15
Table 6. B1, B2, D, and S1 Octets (Functions) ...............15
Table 7. UM1 and UM2 Octets—eoc Bits (Overview) ....16
Table 8. UM1 and UM2 Octets—eoc Bits (Functions) ....16
Table 9. UM2 and UM3 Octet—UCS Bits (Overview) ....17
Table 10. UM2 and UM3 Octet—UCS Bits (Functions) ..17
Table 11. DS Octet (Overview)—Device Status .............18
Table 12. DS Octet (Functions)—Device Status ............18
Table 13. DC Octet (Overview) ......................................19
Table 14. DC Octet (Functions) ......................................19
Table 15. K2 Data Out (DO) Bit Levels ...........................20
Table 16. K2 Device Control (DC) Bit Levels ..................20
Table 17. U-Interface Bit Assignment .............................22
Table 18. DC Octet Description (Control) .......................25
Table 19. DS Octet Description (Status) ........................25
Table 20. adea, ldea, and dea Function .........................26
Table 21. MODE0 Pin Functionality ...............................28
Table 22. Minimal Implementation ..................................29
Table 23. Definitions of Signals During Start-Up ............31
Table 24. Power Consumption .......................................35
Table 25. Performance Ratings ......................................35
Table 26. Crystal Characteristics: Fundamental
Mode Crystal ...............................................................35
Table 27. Internal PLL Characteristics ...........................36
Table 28. Digital dc Characteristics (Over Operating
Ranges) ......................................................................36
Table 29. Clock Timing ...................................................37
Table 30. MTC Requirements and Characteristics
(LT Mode) ....................................................................38
Table 31. RESET
Timing Diagram ................................38

List of Tables

Timing................................................ 38
2 Lucent Technologies Inc.
Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver

Pin Information

The U transceiver consists of a single chip composed of an analog front end (which performs the line interfacing and data conversion functions) and a digital signal processor (which performs the algorithm-specific signal pro­cessing, control, and access functions).
K2 INTERFACE
DO
F
RESET
VDDD
6 4 3 2 1 44 43 4254140
7
CDIMTC
GNDD
RCLKEN
VDDA
A
GNDA
GNDA
A
A
A
VDDA
39
Notes: C = crystal oscillator pins. A = analog pins.
FFC
ILOSS
MODE0
MODE1
GNDD
NC
NC
NC
OSYNC
VDDD
8
9
10
11
12
13
14
15
16
17
C
C
18 20 21 22 23 24 25 2619 27 28
C C
X1
VDDO
GNDO
X2
T7264
GNDD
CKOUT
MCLK

Figure 2. Pin Diagram

CKSEL
HIGHZ
SDINP
38
A
A
37
SDINN
A
36
HP
35
A
LON
GNDA
A
34
33
A
VDDA
32
A
LOP
31
A
HN
30
A
VRN
29
A
A
VCM
GNDD
VRP
5-5804(F)

Table 1. Pin Functions

Device Pin Function Type Number of Pins
+5 V Power & Ground (VDD, GND) Power 14 Analog Line Interface (HP, HN, LOP, LON) Analog 4 Voltage Reference (VRP, VRN, VCM) Analog 3 Receiver to A/D Converter (SDINN, SDINP) Analog 2 Clock Related (X1, X2, CKOUT, CKSEL, MCLK, RCLKEN) Digital 6 K2 Interface Connection (MTC, C, DI, DO, F) Digital 5 Device Status & Control (FFC
, HIGHZ, ILOSS, MODE0, MODE1, OSYNC, RESET) Digital 7 Do Not Connect NC 3 Total —44
Lucent Technologies Inc. 3
T7264 U-Interface 2B1Q Transceiver
Data Sheet
April 1998
DDD
D
(continued)
P
I
I
I
P
K2 Transmit Data Input.
terface at 512 kbits/s. Latched on falling edge of C clock.
Master Timing Clock.
except CKOUT in the 15.36 MHz and 7.68 MHz modes are locked to this input clock. In the NT mode (MODE0 = 0), this input is not used.
512 kbits/s K2 Bit Clock Output.
ing edge to rising edge).
K2 Receive Data Output.
terface at 512 kbits/s. Changes on the rising edge of C clock.
8 kHz Clock Output.
(MODE0 = 1), this clock is locked to MTC at 0° phase shift with ±65 ns of jitter (for jitter-free MTC). In NT mode (MODE0 = 0), this clock is derived from the U-interface signal.
+5 V Supply for Digital Circuits. Reset (Active-Low).
the transceiver in reset indefinitely without the need to access the K2 interface. It must be held low for three consecutive F clock periods for active or idle mode or 1.5 ms after power on. After power-on reset or idle mode reset, an additional
1.0 ms is required before the device is fully functional. transceiver control signals, halts loop transmission, clears the transceiver adap­tive filter coefficients, and resets the phase-locked loop. After a reset, the next activation is a cold start. Unlike afrst (software reset via the K2 interface), when this pin is held low, synchronization is lost between F and MTC (LT). After this pin goes high, F and MTC regain synchronization. All output clocks remain func­tional during reset.
Freeze Frequency Control (Active-Low).
clock frequency control (i.e., the internal state variables of the timing recovery remain constant). This control is operative in both LT and NT modes. This pin is latched on the rising edge of every RCLKEN.
Insertion Loss Test (Active-Low).
continuously transmits the sequence SN1. The receiver remains reset. The transceiver performs a reset when this pin returns to its inactive state. latched on the rising edge of F. Leave this pin unconnected or tied to VDD in LT mode.
Mode 0 and 1.
MODE0 Action
0 Configure for chip being used on the NT end of loop. 1 Configure for chip being used on the LT end of loop.
MODE1 Action
0 Disables autoreporting of nebe to febe. 1 Enables autoreporting of nebe to febe.
Ground Supply for Digital Circuits.
Two-pin field selecting chip mode:
Serial data input passing transmit data across K2 in-
8 kHz clock input. In LT mode (MODE0 = 1), all clocks
Synchronized to F. Defines K2 bit period (ris-
Serial data output passing receive data across K2 in-
Defines K2 frame (rising edge to rising edge). In LT mode
Internally connected together.
Asynchronous Schmitt trigger input. This pin maintains
NT ONLY. When enabled, the transmitter
Internally connected together.
Pin Information

Table 2. Pin Descriptions

Pin Symbol Type Name/Function
1 DI I
2 MTC I
3 C O
4 DO O
5 F O
6, 17 V
7
8
9
10, 11 MODE[0:1] I
12, 22,
27, 44
RESET
FFC
ILOSS
GND
RESET
overrides all other
Asynchronous input. Freeze the
ILOSS
is
4 Lucent Technologies Inc.
Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver
Pin Information
Table 2. Pin Descriptions
(continued)
(continued)
Pin Symbol Type Name/Function
13,
14, 15
16
NC
OSYNC
No Connect.
These pins are connected to internal nodes of the device. Make no con-
nection to them.
O
Out of Sync (Active-Low).
Indicates that framing on the loop signal has not been ac­quired (or has been lost). Equivalent to the K2 interface oof bit in the DS octet. Can sink or source 1.6 mA to drive a low-current external LED. Clocked out on the rising edge of C.
18 V
DDO
P/I
+5 V Supply for the Crystal Oscillator.
Ground when driving MCLK with an external
15.36 MHz clock.
HIGHZ
O
P
Ground Supply for Oscillator. Connection #1 for a 15.36 MHz Crystal. Connection #2 for a 15.36 MHz Crystal. Clock Output. Master Clock. Clock Select.
I
High Impedance (Active-Low).
See Table 3.
See Table 3.
See Table 3.
Causes all digital outputs to become 3-stated.
Common-Mode Voltage Reference for the Analog Circuits.
19 GND 20 X1 I 21 X2 I 23 CKOUT O 24 MCLK I 25 CKSEL I 26 28 VCM
capacitor to GNDA as close to this pin and pin 34 as possible.
29 VRP
Positive Voltage Reference for the Analog Circuits.
to GNDA as close to this pin and pin 34 as possible.
30 VRN
Negative Voltage Reference for the Analog Circuits.
to GNDA as close to this pin and pin 34 as possible.
31 HN I
Hybrid Network Connection, Negative Side.
the transformer.
32 LOP O
Line Driver Output Terminal, Positive Side.
former.
33,
DDA
V
P
+5 V Supply for Analog Circuits.
39, 42
34,
GND
A
P
Ground Supply for Analog Circuits.
40, 41
35 LON O
Line Driver Output Terminal, Negative Side.
transformer.
36 HP I
Hybrid Network Connection, Positive Side.
the transformer.
37 SDINN I
Sigma-Delta A/D Converter Input, Negative Side.
capacitor to SDNIP.
38 SDINP I
Sigma-Delta A/D Converter Input, Positive Side.
capacitor to SDNIN.
43 RCLKEN O
80 kHz Receive Baud Clock.
Defines receive baud period (rising edge to rising edge).
Connect via a 0.1 µF
Connect via a 0.1 µF capacitor
Connect via a 0.1 µF capacitor
Connect directly to the negative side of
Connect to the positive side of the trans-
Connect to the negative side of the
Connect directly to the positive side of
Connect via an 820 pF ± 5%
Connect via an 820 pF ± 5%
Lucent Technologies Inc. 5
T7264 U-Interface 2B1Q Transceiver
Data Sheet
April 1998
Pin Information
(continued)
Table 3. Clock Configuration
DDO
V
+5 V +5 V +5 V +5 V
0 V 0 V
* The 10.24 MHz CKOUT is high for one-half of a 15.36 MHz period and low for one 15.36 MHz period. To compensate for the difference be-
tween the phase-locked and free-run frequencies, one-half 15.36 MHz clock periods are occasionally either removed from or added to the low time of the 10.24 MHz period.
MCLK
0 0 1 1
15.36 MHz
15.36 MHz
CKSEL CKOUT
0 1 0 1
0 1
15.36 MHz (free-running)
10.24 MHz (phase-locked)
7.68 MHz (free-running) 3-stated (default)
15.36 MHz (free-running) 3-stated
*

Functional Overview

+3 +1
–1
–3
QUAT
–101+310+111–300–300+111+310–300–101–101+111–101–300+310+310–101+1
BITS
11
5-5162F

Figure 3. Quat Example

The T7264 chip conforms to the T1.601 ANSI North American 1992 Standard for 2B1Q line encoding. The 2B1Q line code provides a four-level pulse amplitude modulation code with no redundancy. Data is grouped into pairs of bits for conversion to quaternary (quat) symbols. Figure 3 abo v e sho ws an example of this cod­ing method.
The analog front end provides the 2B1Q line coder (D/A conversion), pulse shaper, line driver, first-order line balance network, crystal oscillator clock genera­tion, and sigma-delta A/D conversion. The line driver provides pulses which allow the 2.5 V template of the T1.601 specification to be met when connected to the proper transformer and interface circuitry. The A/D con­verter is implemented using a double-loop, sigma-delta modulator.
A crystal oscillator provides the 15.36 MHz master clock for the chip . An on-chip, digital phase-locked loop provides the ability to synchronize the chip clock to the system clock in the LT or to the line clock in the NT.
Provisions are made for using either an on-chip crystal oscillator with an external crystal, or using an external clock source.
The T7264 takes input at the K2 interface and formats this information for the U-interface through a scram­bling algorithm and the addition of synchronization bits for U framing. This data is then transferred to the 2B1Q encoder for transmission over the U loop. Signals com­ing from the U loop are first passed through the sigma­delta A/D converter and then sent for extensive signal processing. The T7264 provides decimation of the sigma-delta output (DEC), linear and nonlinear echo cancellation, automatic gain control (AGC), signal detection, decision feedback equalization (DFE), timing recovery (TR), descrambling, line-code polarity detec­tion, and rate adaption for output onto the K2 interface. The DFE circuit provides the functionality necessary for proper operation on subscriber loops with bridged taps.
6 Lucent Technologies Inc.
Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver
Functional Overview
(continued)
The device provides rapid cold start and warm start op­eration. From a cold start, the device is typically opera­tional within 3.5 s. The device supports activation/ deactivation, and, when properly deactivated, it stores the adaptive filter coefficients such that upon the next activation request, a faster warm start is possible. A warm start typically requires 200 ms for the device to be­come operational.
The T7264 has an on-chip activation/deactivation state machine and timers, and automatically moves from state T0 to T7 (as specified in the T1.601 standard) dur­ing activation. This simplifies the implementation of the T1.601 (Appendix C) state table. The signals from the device control and status octets on the K2 interface pro­vide the control necessary to complete the state table. The activation/deactivation process is controlled over the K2 interface.
The T7264 has a low-power mode which it automatically enters when it is in the idle state. The idle state occurs after deactivation, loss of sync on the U-interface, or re­leasing reset. In the low-power mode, power consump­tion is typically 30 mW.

Device Interface and Connections

The T7264 transceiver allows systems to meet the loop-range requirements of ANSI Standard T1.601 when the transceiver is used with the proper peripheral circuitry. Devices achieve better than 10–7 bit error rate over 18 kft of 26 AWG loop cable.

Analog Device Interface

Proper line termination is required, utilizing appropriate interface components, to meet the 2.5 V pulse tem­plate. The output of the T7264 should first pass through a pair of 16.9 Ω resistors and into a 1.5:1 ratio trans­former, such as the Lucent 2754H (or the short-lead version 2754H2). The output of the transformer is cou­pled through a 1.0 pair of 16.9 resistors, and then drives the 135 line.
Surge protection circuitry is necessary on each side of the transformer when the U loop is external to a build­ing. The protection between the 16.9 resistors and the transformer should be a Lucent 521A surge protec­tor or equivalent. A relay may be needed to disconnect the loop plant for local loopback testing. Figure 4 shows a recommended circuit for interfacing the T7264 to the line; however, the specific interface is system depen­dent.
µF capacitor, is passed through a
820 pF ± 5%
LOOPBACK
RELAY
36 32
35 31
GNDA
HP LOP
LON
HN
0.1 µF
1.0 µF 701C
10
2754H
1.5:1
7
6 9
1
5
dc
REMOTE
POWER
SOURCE
16.9 Ω ± 1%
521A
SURGE
PROTECTION
16.9 Ω ± 1%
16.9 Ω ± 7%
SURGE
PROTECTION
16.9 Ω ± 7%
LUCENT
Note: 3000 pF ± 1% capacitors from HP and HN to GNDA may improve operation of the tone decoder in the presence of interfering common-
mode signals.
37 38
SDINN
T7264
A
VRP
VRCM
VRN
GND
29 28 30 24
SDINP
5-5803Fa

Figure 4. Line Interface and Protection

Lucent Technologies Inc. 7
T7264 U-Interface 2B1Q Transceiver
Data Sheet
April 1998
Device Interface and Connections
(continued)

Power Supply Connections

Figure 5 shows a recommended power supply connec­tion. C is a 10 µF capacitor. Each pair of power and ground pins should be decoupled with 0.1 µF and
1.0 µF capacitors. Each of the three leads (VCM, VRP, and VRN) associated with the voltage reference should be decoupled with 0.1 µF capacitors. Place the capaci­tors as close as possible to the power or reference and ground pins which they decouple.

Clock Operation

The master clock for the T7264 may either be internally generated by the on-chip crystal oscillator or supplied by the user via the MCLK pin. In the latter case, V must be grounded. In the LT mode, an on-chip digital phase-locked loop phase locks the F clock to the exter­nally supplied MTC clock, unless FFC is active-low. In NT mode, F synchronizes to the signal received from the LT through the U-interface. If the on-chip crystal os­cillator is used, the crystal must conform to the require­ments given in Table 26.

Reset Operation

The T7264 can be reset via the K2 interface (issuing afrst for three consecutive K2 frames) or via hardware (RESET). The only difference between these two resets is that, in the LT mode, the timing recovery filter is reset
DDO
only by a hardware reset. The RESET
pin can be used to hold the transceiver in reset indefinitely. If a hardware reset is used when the chip is being powered up, RESET must be held low for 1.5 ms; however, if the chip is already powered up, then holding RESET low for three K2 frames is sufficient.
The reset state is terminated, and the chip enters idle mode on the K2 frame following the end of the reset sig­nal.

Reset Sequences and Clock Synchronization

In normal use, a power-on reset can be obtained by connecting a capacitor to the RESET
pin. The internal pull-up resistor, acting with an on-chip Schmitt trigger on this pin, can be used to reset the chip. In this case, the RESET waveform is shown in Figure 6.
When using this reset procedure, the various clocks generated by the transceiver are not synchronized. However, during testing, it can be useful to initialize all the counters of the clock generator so that the various clocks generated by the transceiver can be synchro­nized to the test equipment. The RESET pin can ac­complish this by applying the sequence shown in Figure
7. Furthermore, the RESET pin transitions should align with falling edges of MCLK. If the internal crystal oscil­lator is used, this can be accomplished by configuring CKOUT for 15.36 MHz and ensuring that RESET tran­sitions align with the falling edge of CKOUT. The user should be aware, however, that if this clock synchroni­zation reset sequence is used after a period of normal operation, the phase of the clocks generated by the T7264 (such as F, RCLKEN, C, CKOUT, etc.) may sud­denly change as a result of the clock resynchronization.
TO VDDD (INTERNAL VCXO)
OR GNDD (EXTERNAL MCLK)
+5 V
SYSGND
VDDD 6, 17, 18
C
DIGITAL ANALOG
GND
D
12, 22, 27, 44
VDDO
GNDO 19
VDDA 33, 39, 42
VCM, 28 VRP, 29 VRN, 30
GNDA
(34, 40, 41)
0.1 µF
0.1 µF
0.1 µF
5-5164a

Figure 5. Recommended Power Supply Connections

88 Lucent Technologies Inc.
Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver
Device Interface and Connections (continued)

Reset Time

Reset time depends on the conditions under which the chip is reset. There are three cases to consider:
When the chip is initially powered on, the RESET pin must be held low (below 0.5 V) for 1.5 ms. This allows
1.0 ms for the oscillator start-up and 0.5 ms for the digital reset process. An additional 1.0 ms is needed to allow the analog circuitry to fully power up before the chip becomes fully functional.
When the chip is in the idle mode, a software or hardware reset, applied f or a minimum of three K2 frames, starts
the reset process. As before, the analog circuitry requires an additional 1.0 ms before the chip becomes fully functional.
If the chip is already fully powered up and functional, a software or hardware reset, applied for a minimum of
three K2 frames, is sufficient to complete the reset process.
When the chip is in the reset state, the output of the line driver is at 0 V and the transmit data is also 0 V.
POWER SUPPLY VOLTAGE
4.75 V
1.5 ms MIN
t
RESET PIN
INTERNAL RESET
(AFTER SCHMITT
TRIGGER)
PIN
RESET
F
C
4.75 V
1.0 ms
DEVICE REACHES POWER-ON MODE (FULLY FUNCTIONAL)

Figure 6. RESET Waveform Normal Operation

POWER SUPPLY VOLTAGE
2.5 ms
1 MCLK PERIOD
1
UNDEFINED
UNDEFINED
0 0
1
3 K2
FRAMES
2 MCLK PERIODS
t
5-5165a
NORMAL
RESET
AS IN FIGURE 6
5-5166a

Figure 7. RESET Timing for Synchronized Clocks

Lucent Technologies Inc. 9
T7264 U-Interface 2B1Q Transceiver
Data Sheet
April 1998
Device Interface and Connections
(continued)

Idle Mode

A low-power idle mode is implemented on the T7264 to reduce the power consumption to typically 30 mW when it is not active. All internal coefficients are saved in this idle mode to reduce time for a subsequent start-up. There are three ways that idle mode can be entered:
If the loop is operational, the local deactivation com-
mand (ldea) in the LT mode via the K2 interface causes the deactivation procedure specified in the ANSI standard. At the conclusion of the deactivation procedure, shutdown of the line driver and activation of the tone detector occurs. If no tone is detected within 48 ms, the idle mode is entered. This 48 ms window constitutes the RECEIVE RESET criteria in the ANSI standard.
If a failure condition is encountered (e.g., the loop
never comes up), a procedure similar to deactiv ation is followed. The only difference is the duration of the window, which is set internally by the type of failure condition.
As long as either the afrst (via the K2 interface) or
the RESET pin is active, the transceiver remains in the powerup reset state. At the cessation of the reset condition, the transceiver changes to the idle state.
There are four ways of bringing the device out of the idle mode:
An initiate start-up procedure (istp) command is
received via the K2 interface by the device.
A reset (afrst or external RESET) command is
received by the device.
A tone is detected by the tone detector.
A command to enter any of the test modes (loopback
and insertion loss) is received by the device.
Internal timing ensures that the digital signal processor blocks do not change state during the idle mode-to­powerup process. In addition, the start-up process has been designed to prevent glitches on the line as the driver powers up.

NT Maintenance

ANSI T1.601-1992 defines NT quiet mode operation and an insertion loss measurement, and support for these is available from the T7264. Detection of the trig­ger signals is done by other hardware which notifies the system controller, and the system controller then sig­nals the T7264 as needed to do the following:
To enter the quiet mode, the chip is placed in reset.
When an insertion loss measurement is requested,
ILOSS (pin 9) is asserted low. This causes the trans­mitter to continuously send SN1 and places the receiver in reset. When the test is completed or ter­minated, ILOSS is asserted high and the chip is reset. Priority between RESET and ILOSS is described in the Priority section of this document (page 31).
1010 Lucent Technologies Inc.
Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver

K2 Interface Description

The K2 interface consists of five pins on the T7264: the data out (DO), data in (DI), data clock (C), K2 frame sync (F), and master timing clock (MTC). C is a 512 kHz output signal for clocking data into and out of the device with 1 bit per clock cycle. F is an 8 kHz signal indicating the beginning of a K2 frame. MTC is used in LT mode and must be an 8 kHz ± 32 ppm system clock to meet T1.601 requirements.
In LT mode, F is phase-locked to the MTC input through the on-chip digital phase-locked loop. Jitter in MTC is tracked by F at frequencies below 0.5 Hz. MTC jitter at frequencies higher than 0.5 Hz is attenuated by the phase-locked loop (PLL). In the NT mode, the F clock is derived from incoming data from the U loop.
B1 TIME SLOT
C
F
DO
1
2
3
The first bit of a K2 frame begins simultaneously with the rising edge of F. Transitions on DO occur following the rising edge of C, and DI is latched on the falling edge of C. Figure 8 shows the relationship between the C, F, DO, and DI.
The K2 frame consists of eight octets for a total of 64 bits. These bits are transferred synchronously over a 512 kHz interface with a frame rate of 8 kHz or 125 µs. The major purpose of the K2 interface is to provide 2B+D data transfer between other devices and the chip. In addition, there are framing bits (DF), U-interface maintenance and control bits (UM), and device control/status bits (DC/DS).
4
5
6
7
8
DO
DI
DI
1
2 3
4
5
6
7 8
5-5167F

Figure 8. K2 Interface Timing

C
F
B1 B2 DF UM1 UM3 DSUM2All 1s
B1 B2 D UM1 UM3 DCUM2All 1s
5-5158

Figure 9. K2 Octets

Lucent Technologies Inc. 11
T7264 U-Interface 2B1Q Transceiver
Data Sheet
April 1998
K2 Interface Description (continued)
K2 NT and LT Timing Sources
In LT applications, all devices typically derive their tim­ing from the same MTC. Additional logic in the LT, such as a T7270, can provide concentration of multiple K2 in­terfaces onto a single higher-speed highway.
In a PBX application, the U-interface loops can be used as trunks. If more than one incoming U trunk is to be used, additional circuitry may be needed to provide
DO
T7264
MTC F
C DO
DI
INTERFACE
NT
INTERFACE
NT
S/T
T7252A
F
C
DI
4-WIRE S/T-INTERFACE
DO
VDD
F
C
DI
K2 NT1 LOGIC
elastic store, time-slot allocation, and master frame tim­ing to synchronize the K2 interfaces received at each trunk onto a common interface.
In NT1 applications, K2 frame timing is also derived from the received 2B1Q data on the U loop. A T7264 chip can be connected to an S/T-interface device (such as the T7252A) to form an NT1. Figure 10 shows the K2 interface connection in a CO application and NT1 appli­cation. For terminal applications, the derived K2 timing could be the source of all timing within the equipment (if only a single U-interface is needed).
CO SWITCHNT1
2-WIRE U-
2-WIRE U-
LT
LT
T7264
MTC
• • •
T7264
MTC
DO
DO
F
C
DI
TIMING
MASTER
F
C
DI
SYSTEM
F C DI DO
SYSTEM
F C DI DO
K2-TO-
BACK-
PLANE
LOGIC
• • •
K2-TO-
BACK-
PLANE
LOGIC
5-5169

Figure 10. K2 Interface LT and NT

1212 Lucent Technologies Inc.
Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver
K2 Interface Description (continued)

K2 Bits Description

Table 4 summarizes the K2 interface bits which are common to all configurations. The K2 frame consists of eight octets of data. The first three octets contain the 18 bits of 2B+D data. Bits 5—8 of the third octet contain U frame and superframe timing (DF). Octet 4 (S1) is reserved for future use and should always be set to 1. Octets 5, 6, and 7 are directly mapped to the U-inter-

Table 4. K2 Interface Serial Data Bit Map

Bits marked with 1 should always be set to a 1. Bits marked as Rxx are reserved by T1.601 and should be set to a 1.
Time ----------------------------------------------------------->
Symbol Octet Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 8
B1 1 B11 B12 B13 B14 B15 B16 B17 B18 B2 2 B21 B22 B23 B24 B25 B26 B27 B28
D 3 D1 D2 1 1 1 1 1 1 DF 3 D1 D2 1 1 RSF RF TSF TF S1 4 1 1 1 1 1 1 1 1
UM1 5 a1 a2 a3 dm i1 i2 i3 i4 UM2 6 i5 i6 i7 i8 act R1, 5 R1, 6 * UM3 7 R2, 5 * * * * R6, 4 * *
DS 8 nebe xact DC 8 ccrc istp lpbk afrst ldea 1 sksi xpcy
face M (UM) maintenance bits which are transparent to the device, except the adea bit. Octet 8 is for device status (DS) and device control (DC). These bits must be manipulated according to the T1.601 standard to obtain proper system-level operation.
Figure 11 describes the four different K2 interface for­mats for DO and DI at the NT and LT. Tables 5—14 de­scribe the position and meaning of the various bits on the K2 interface. Tables 15 and 16 show the active logic level for these bits, their value during reset/idle, and their value when the transceiver is operational.
1 oof 1 rsksi 1
* Items differ dependent upon NT or LT mode. † Don't care.
Lucent Technologies Inc. 13
T7264 U-Interface 2B1Q Transceiver
K2 Interface Description (continued)
xpc
y
i
sks
1
l
dea
f
t
a
r
l
p
i
s
c
crc aib uoa R R R R
f
R
ade
R R a
eoc
r
s
b
t
6 5 4 3
ebe
2 1
1 c
k
p
4 4 4 4
5
a 6 5
t i
i i i i i i i d a a a
DS
8 7 6 5 4 3 2 1 m
3 2 1
i
r
sks
111
f
o
o
r
1
0
o
t
xac neb
e aib uoa
6
4
R
5
4
R
4
4
R
3
4
R
f
ebe
2
5
R dea
1
6
R
1
5
R
t
c
a
i
8
i
7
i
6
i
5
i
4
i
3
i
2
eoc
i
1
d
m
a
3
a
2
a
1
DC
xpc sks
l
f
a
l i c
f
r
eoc
dea p
s
crc nib s R c n ps2
R ps1
R R a
y i
1
t
r
s
k
b t
p
i
a 6
4
s
o
t
m
ebe
2
5
1
6
1
5 t
c
i
8
i
7
i
6
i
5
i
4
i
3
i
2 1
i d
m
a
3
a
2
a
1
DS
r
sks
1 xac neb
f
i
111
f
o
o
r
0
o
t e
nib
i
s
a 6
4
R c
s
o
t
n
m
ps2
ebe
2
5
R ps1
1
6
R
1
5
R
t
c
a
i
8
i
7
i
6
i
5
i
4
i
3
i
2
eoc
i
1
d
m
a
3
a
2
a
1
Data Sheet
April 1998
12345 678OCTET
B1 B2 D S1 UM1 UM2 UM3 DC
B1 CHANNEL B2 CHANNEL D 11111111111111
DI
DI
LT
AT

Figure 11. K2 Interface Frame Format

S1 UM1 UM2 UM3
DF
B1 B2
11111111
t
f
tsf
r
f
rsf
11
B1 CHANNEL B2 CHANNEL D
AT
NT
DO
S
B1 B2 D UM1 UM2 UM3
S1 UM1 UM2 UM3
11111111
t
f
tsf
r
f
rsf
DF
B1 B2
DO
DO
B1 CHANNEL B2 CHANNEL D 1 1
LT
LT
AT
5-5170
B1 CHANNEL B2 CHANNEL D 11111111111111
DI
DI
AT
NT
NT
14 Lucent Technologies Inc.
Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver
K2 Interface Description (continued)

Table 5. B1, B2, D, and S1 Octets (Overview)

Octet Octet # DO/DI Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 8
B1 1 DO/DI B11 B12 B13 B14 B15 B16 B17 B18 B2 2 DO/DI B21 B22 B23 B24 B25 B26 B27 B28
D 3 DI D1 D2 1 1 1 1 1 1 DF 3 DO D1 D2 1 1 RSF RF TSF TF S1 4 DO/DI 1 1 1 1 1 1 1 1

Table 6. B1, B2, D, and S1 Octets (Functions)

Octet Bit # Symbol Name/Function
B1 1—8 B11—B18 B1 Octet. The B1 octet is used for transferring basic access channel B1. B11 is the
first bit of the B1 octet sent or received.
B2 1—8 B21—B28 B2 Octet. The B2 octet is used for transferring basic access channel B2. B21 is the
first bit of the B2 octet sent or received.
D 1—2 D1, D2 D Octet. The two D-channel bits are transmitted in the first 2 bits of the D octet. D1
is the first bit of the D pair sent or received.
DF 5 RSF Receive Superframing. 12.5% duty cycle at an 83.333 Hz rate (12 ms).
0—Last 84 K2 frames of the superframe. 0 to 1—Marks the first K2 frame of 2B+D data. Corresponds to the first 2B+D data
of the U superframe.
1—First 12 K2 frames and during reset state up to point T6 or T7.
DF 6 RF Receive Framing. 50% duty cycle at a 666.66 Hz rate (1.5 ms).
0—Last six K2 frames of the U frame. 0 to 1—Marks every 12th K2 frame of 2B+D data.
Corresponds to the first 2B+D data of the U frame.
1—First six K2 frames and during reset state up to point T6 or T7.
DF 7 TSF Transmit Superframing. 12.5% duty cycle at an 83.333 Hz rate (12 ms).
0—Last 84 K2 frames of the superframe 0 to 1—Marks the first K2 frame of 2B+D data.
Corresponds to the first 2B+D data of the U superframe.
1—First 12 K2 frames and during reset state up to point T6 or T7.
DF 8 TF Transmit Framing. 50% duty cycle at a 666.66 Hz rate (1.5 ms).
0—Last six K2 frames of the U frame. 0 to 1—Marks every 12th K2 frame of 2B+D data.
Corresponds to the first 2B+D data of the U frame.
1—First six K2 frames and during reset state up to point T6 or T7.
S1 1—8 S11—S18 S1 Octet. All bits of the S1 octet are set to 1.
Lucent Technologies Inc. 15
T7264 U-Interface 2B1Q Transceiver
Data Sheet
April 1998
K2 Interface Description (continued)

Table 7. UM1 and UM2 Octets—eoc Bits (Overview)

Octet Octet # DO/DI Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 8
UM1 5 DO/DI a1 a2 a3 dm i1 i2 i3 i4 UM2 6 DO/DI i5 i6 i7 i8 See next page.

Table 8. UM1 and UM2 Octets—eoc Bits (Functions)

Additional details on eoc bits can be found in T1.601.
Octet Bit # Symbol Name/Function
UM1, 2 1—8, 1—4 eoc eoc Bits. The eoc bits are passed transparently from the U-interface to the
K2 interface and from the K2 to the U-interface. The transceiver maintains the eoc information at the K2 interface until a new block of eoc information is available.
UM1 1—3 a1—a3 eoc Address.
000—NT address. 001—LT to NT intermediate address. 010—110—LT to NT, decrement address and pass on. 001—101—NT to LT, increment address and pass on. 111—Broadcast address.
UM1 4 dm Data or Message Indicator.
0—Data. 1—Message.
UM1, 2 5—8, 1—4 i1—i4,
i5—i8
Information. eoc channel message information.
01010000—Operate 2B+D loopback. 01010001—Operate B1 channel loopback. 01010010—Operate B2 channel loopback. 01010011—Request corrupt crc. 01010100—Notify of corrupted crc. 11111111—Return to normal. 00000000—Hold state.
10101010—Unable to comply. Refer to T1.601 for codes which are reserved, nonstandard, or internal net­work use.
16 Lucent Technologies Inc.
Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver
K2 Interface Description (continued)

Table 9. UM2 and UM3 Octet—UCS Bits (Overview)

Octet Octet # DO/DI Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 8
UM2 6 DOLT/[DINT] See previous page. act R1, 5 R1, 6 ps1 UM2 6 DONT/[DILT] See previous page. act R1, 5 R1, 6 [a]dea UM3 7 DOLT/[DINT] R2, 5 [r]febe ps2 ntm cso R6, 4 sai nib UM3 7 DONT/[DILT] R2, 5 [r]febe R3, 4 R4, 4 R5, 4 R6, 4 uoa aib

Table 10. UM2 and UM3 Octet—UCS Bits (Functions)

Octet Bit # Symbol Name/Function
UM2 5 act Activation. Passed transparently from the K2 to the U-interface and from the U to the
K2 except during a start-up when it is forced to a 0 on the K2.
0—Pending activation. 1—Ready to transmit information.
UM2 6, 7 Rx, y Reserved Bits. Passed transparently from the K2 to the U-interface and from the U
to the K2. Transmit should always be set to a 1.
UM2 8 ps1
(DOLT/
DINT)
UM2 8 [a]dea
(DONT/
DILT)
UM3 1, 6 Rx, y Reserved Bits. Passed transparently from the K2 to the U-interface and from the U
UM3 2 [r]febe [Receive] Far-End Block Error. If the MODE1 = 1, rfebe is ANDed with nebe and the
UM3 3 ps2
(DOLT/
DINT)
UM3 4 ntm
(DO
DINT)
Power Status #1. Passed transparently from the K2 to the U-interface at the NT and from the U to the K2 at the LT.
0—Primary power out. 1—Primary power is normal.
When both ps1 and ps2 are 0, this indicates a dying gasp. [AND with] Deactivate. In LT mode, this bit is used in conjunction with the ldea bit
from the K2, then passed to the U-interface as the transmitted dea bit. In NT mode, this bit is passed transparently from the U to the K2 interface. Allows deactivation warning to the far-end NT without deactivating the local transceiver.
0—Deactivation warning. 1—Normal.
to the K2 interface. Transmit should always be set to a 1.
result is sent out as the U-interface febe bit. If the MODE1 = 0, rfebe is passed trans­parently from the K2 (DOLT/DINT) to the U-interface febe bit. For either setting of MODE1, the febe bit is passed transparently from the U-interface to the K2 interface.
0—Error indication passed to the originator. 1—No error, or feature is not utilized.
Power Status #2. Passed transparently from the K2 to the U-interface at the NT and from the U to the K2 at the LT.
0—Secondary power out. 1—Secondary power normal.
When both ps1 and ps2 are 0, this indicates a dying gasp. NT Test Mode. Passed transparently from the K2 to the U-interface at the NT and
LT/
from the U to the K2 at the LT.
0—The NT is currently in a test mode. 1—Normal.
Lucent Technologies Inc. 17
T7264 U-Interface 2B1Q Transceiver
K2 Interface Description (continued)
Table 10. UM2 and UM3 Octet—UCS Bits (Functions) (continued)
Octet Bit # Symbol Name/Function
UM3 5 cso
(DOLT/
DINT)
UM3 3, 4,
5
UM3 7 sai
UM3 7 uoa
UM3 8 nib
UM3 8 aib
Rx, y
(DONT/DILT)
(DINT/ DOLT)
(DILT/
DONT)
(DINT/ DOLT)
(DILT/
DONT)
Cold Start Only. Passed transparently from the K2 to the U-interface at the NT and from the U to the K2 at the LT.
0—Cold and warm start capability. 1—Cold start only.
Reserved Bits. Passed transparently from the K2 to the U-interface (DILT) and from the U to the K2 interface (DONT). Transmit should always set to a 1.
S/T-Interface Activity Indicator. Passed transparently from the K2 to the U-inter­face at the NT and from the U to the K2 interface at the LT.
0—No activity at the S/T-interface. 1—Activity (INFO1 or INFO3) at S/T-interface.
U-Interface Only Activation. Passed transparently from the K2 to the U-interface at the LT and from the U to the K2 interface at the NT.
0—Request S/T deactivation at the NT. 1—Allow S/T activation at the NT.
Network Indicator Bit. Passed transparently from the K2 to the U-interface at the NT and from the U to the K2 interface at the LT. Reserved for network use. Normally set to 1 in customer premises equipment.
Alarm Indication Bit. Passed transparently from the K2 to U-interface at the LT and from the U to the K2 interface at the NT.
0—Failure of intermediate 2B+D transparent element. 1—Transmission path is established between NT and local exchange.
Data Sheet
April 1998

Table 11. DS Octet (Overview)—Device Status

Octet Octet # DO/DI Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 8
DS 8 DO nebe xact 1 oof 1 rsksi 1

Table 12. DS Octet (Functions)—Device Status

Octet Bit # Symbol Name/Function
DS 1 nebe Near-End Block Error.
0—crc error detected in previously received U frame. 1—Normal.
DS 2 xact Transceiver Active.
0—Transceiver in reset state. 0 to 1—Detection of a tone or istp = 0. 1—Transceiver active.
1 to 0—On reset, 480 ms after loss of sync or deactivation. DS 3 Undefined. May be either a 1 or a 0. DS 4, 6, 8 Reserved. In normal operation, these bits are 1. DS 5 oof Out of Frame.
0—Out of frame.
1 to 0—Initiates the 480 ms loss of synchronization timer.
1—Normal. DS 7 rsksi Reflected System-to-K2. This bit reflects the value of the sksi bit received over the
K2 interface.
18 Lucent Technologies Inc.
Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver
K2 Interface Description (continued)

Table 13. DC Octet (Overview)

Octet Octet # DO/DI Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 8
DC 8 DI ccrc istp lpbk afrst ldea 1 sksi xpcy

Table 14. DC Octet (Functions)

Octet Bit # Symbol Name/Function
DC 1 ccrc Corrupt Cyclic Redundancy Check. This bit is used to corrupt the crc information
transmitted by the transceiver to the U-interface.
0—Corrupt crc generation as long as bit is low. 1—Generate correct crc (normal).
DC 2 istp Initiate Start-Up. This bit is used to notify the transceiver of an activation request.
Should be set to a 1 during loopback. If xact = 1, istp is ignored; if xact = 0:
0—Initiate start-up (activation request). 1—Reset state (transceiver inactive).
DC 3 lpbk Local Loopback.
0—Loopback.
1—Normal. Loop back the complete 160 kbits/s U-interface bit stream at the analog output. Loop­back turns off echo canceler and reconfigures the descrambler. Device should be re­set and line disconnected before loopback test; istp should be set to a 1 during loopback.
DC 4 afrst Adaptive Filter Reset.
0—Normal.
1—Reset. 2B+D and UM set equal to 1 on DO. Reset halts loop transmission and clears the transceiver's adaptive filter coefficients, overriding all other transceiver control sig­nals. This provides the same functionality as the RESET pin on the T7264, except F to MTC synchronization (LT) is not lost.
DC 5 ldea Local Deactivation.
0 — Normal.
1 — Deactivate. DO 2B+D and UM set equal to 1. Upon receiving ldea = 1 from the system device, the transceiver will save adaptive fil­ter coefficients. In the LT, the device sends three or four U superframes of dea = 0, then ceases transmission and enters the idle state. In the NT, the device deactivates upon signal loss and enters the idle state. In the NT, ldea should be set before the loss of signal (on second dea = 0) and held until xact goes low for proper deactivation.
DC 6 Reserved. For normal operation, this bit must be set to 1. DC 7 sksi System-to-K2. This bit may be set high or low without affecting the state of the trans-
ceiver. sksi is reflected back from the T7264 across the K2 interface by means of the rsksi bit.
DC 8 xpcy Transparency.
0—Transparent 2B+D.
1—LT mode 2B+D = 0 transmitted across the U-interface.
1—NT mode 2B+D = 1 transmitted across the U-interface. This bit only affects the data transmitted on the U-interface. The U-to-K2 interface al­ways remains transparent after start-up.
Lucent Technologies Inc. 19
T7264 U-Interface 2B1Q Transceiver
Data Sheet
April 1998
K2 Interface Description (continued)

K2 Bit Levels

Table 15. K2 Data Out (DO) Bit Levels

(+) Active = 1 (T) Transparent (–) Active = 0 (P) Pulsing
Bit Name Description True Level Reset/Idle Operational
U-Interface Related
B1, B2 ISDN 64 kbits/s B1, B2 Octet 1 T
D ISDN 16 kbits/s D Bits 1 T
RSF, TSF Receive/Transmit Superframe + 1 P
RF, TF Receive/Transmit Frame + 1 P
UM Bits
eoc eoc addr, d/m, and info bits + 1 T
act Activate + 0 1
dea Deactivate 1 1
ps1, ps2 Primary/Sec. Power Status + 1 1
febe Far-end Block Error 1 1
ntm NT in Test Mode 1 1 cso Cold Start Only + 1 0 or 1
sai S/T Activity Indicator + 1 1
uoa U Only Activation 1 1
nib Network Indicator Bit 1 1 aib Alarm Indication Bit 1 1
R Reserved 1 1
DS Bits
nebe Near-end Bit Error 1 1
xact Transceiver Active + 0 1
oof Out of Frame 0 1

Table 16. K2 Device Control (DC) Bit Levels

(+) Active = 1 (x) Either 1 or 0 (–) Active = 0
Bit Name Description True Level Reset/Idle Operational
ccrc Corrupt the Outgoing crc x 1
istp Initiate Start-up 1 0 then x
lpbk Loopback 1 1 afrst Reset + 1 then x 0 ldea Local Deactivate + 1 then x 0 xpcy Transparency 1 0
20 Lucent Technologies Inc.
Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver

U-Interface Description

Data is transmitted over the U-interface in 240-bit groups called U frames. Each U frame consists of an 18-bit syn­chronization word (ISW or SW), 12 blocks of 2B+D data (216 bits), and six overhead bits (M). A U-interface super­frame consists of eight U frames grouped together. The beginning of a U superframe is indicated by the inverted sync word (ISW). The six overhead bits from each of the eight U frames, when taken together, form the 48 M bits. The following diagram shows how U frames, superframes, and M bits are mapped.
U-FRAME SPAN = 1.5 ms
ISW[18] M[6]
U1 U2 U3 U4 U5 U6 U7 U8
(2B+D) X 12 [216 bits]
U-SUPERFRAME SPAN = 12 ms
U-INTERFACE M BITS [48]
5-5171

Figure 12. U-Interface Frame and Superframe

Of the 48 M bits, 24 bits form the embedded operations channel (eoc) for sending messages from the LT to the NT and responses from the NT to the LT. There are two eoc messages per superframe with 12 bits per eoc message (eoc1 and eoc2). Another 12 bits serve as control and status bits (UCS). The last 12 bits form the cyclic redun­dancy check (crc) which is calculated over the 2B+D data and the M4 bits of the previous superframe. Figure 13 shows the different groups of bits in the superframe.
BIT #
FRAME # Sync 12(2B+D) M1 M2 M3 M4 M5 M6
1 2 3 4
1—18 19—234 235 236 237 238 239 240
ISW
SW
eoc1
2B+D
CONTROL & STATUS (UCS)
5 6 7 8
eoc2
crc
5-5172

Figure 13. U-Interface Superframe Bit Groups

Lucent Technologies Inc. 21
T7264 U-Interface 2B1Q Transceiver
Data Sheet
April 1998
U-Interface Description (continued)

Table 17. U-Interface Bit Assignment

Bit # 1—18 19—234 235 236 237 238 239 240
Frame # Sync 12(2B+D) M1 M2 M3 M4 M5 M6
1 ISW 2B+D eoca1 eoca2 eoca3 act R1, 5 R1, 6 2 SW 2B+D eocdm eoci1 eoci2 dea (ps1)* R2, 5 febe 3 SW 2B+D eoci3 eoci4 eoci5 R3, 4 (ps2)* crc1 crc2 4 SW 2B+D eoci6 eoci7 eoci8 R4, 4 (ntm)* crc3 crc4 5 SW 2B+D eoca1 eoca2 eoca3 R5, 4 (cso)* crc5 crc6 6 SW 2B+D eocdm eoci1 eoci2 R6, 4 crc7 crc8 7 SW 2B+D eoci3 eoci4 eoci5 uoa (sai)* crc9 crc10 8 SW 2B+D eoci6 eoci7 eoci8 aib (nib)* crc11 crc12
* LT(NT). Values in parentheses () indicate meaning at the NT.

K2 Functional Description

The K2 interface provides the mechanism f or transf erring data and control inf ormation between the system and the T7264. A K2 frame consists of eight DO octets and eight DI octets which occur every 125 µs (every frame sync). Figure 14 shows the K2 frame structure.
TIME (125 µs)
DO
DI
B1 B2 D UM1 UM2 UM3 DC B1 B2 D UM1 UM2 UM3 DS
1s DF
S1 S1
eoc
UCS
5-5173

Figure 14. K2 Octet Description

Figure 15 shows the points of origination and destination of bits on the K2 and U-interfaces at the LT and NT.
K2 K2
DC - ccrc, afrst, istp, lpbk, xpcy, ldea
UM2, 3 - adea, act, rfebe, uoa, nib UM1, 2 - eoc(12) B1/B2/D - R(9)
B1/B2/D - R(6) UM1, 2 - eoc(12) UM2, 3 - ps1, act, febe, ps2, ntm, cso, sai, nib
DI
DO
T7264
LT
2B1Q
2-WIRE
U-
INTERFACE
T7264
NT
DF - RSF, RF, TSF, TF DS - nebe, xact, wstrt, oof
UM2, 3 - dea, act, febe, uoa, aib UM1, 2 - eoc (12) B1/B2/D - R (9)
DO
B1/B2/D - R(6)
DI
UM1, 2 - eoc(12) UM2, 3 - ps1, act, rfebe, ps2, ntm, cso, sai, nib
DF - RSF, RF, TSF, TF DS - nebe, xact, wstrt, oof
DC - ccrc, afrst, istp, lpbk, xpcy, ldea
5-5174

Figure 15. K2 Functional Description

22 Lucent Technologies Inc.
Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver
K2 Functional Description (continued)
The U superframe and the K2 superframe both occur once every 12 ms. The U frame consists of 240 bits, with eight U frames per superframe, transferred at a data rate of 160 kbits/s. The K2 superframe consists of 96 K2 frames transferred at a data rate of 512 kbits/s.
In mapping the K2 to U, the bloc ks of 2B+D data, which occur once every K2 frame, are accumulated within the T7264 and are output in groups of twelve blocks per U frame onto the U-interface. The last 6 bits of the D octet and the S1 octet are unused on DI. While every K2 frame has bits allocated for eoc messages, only two messages per U superframe are needed. K2 frame number 11 (K11) provides the data for the first eoc message on the U-interface, and K2 frame K59 pro­vides the data for the second eoc message. The other 94 K2 frames are unused. Ev ery K2 frame also has bits allocated for UCS data; however, only a single set of UCS data is needed in a U superframe. K2 frame num­ber K11 provides the UCS data while the other 95 K2 frames are unused. The crc is automatically generated by the T7264 and presented to the U-interface. The DC octet is used to transfer control data to the T7264 and is sampled every K2 frame.
In mapping the U to K2, the 2B+D data, which occur in groups of 216 bits (12 times [2B+D]), are accumulated within the T7264 and output as one 2B+D block per K2 frame. The last 4 bits of the D octet provide indication
onto the K2 interface about when data transferred on the K2 interface corresponds to data transferred on the U-interface for both transmit and receive. The eoc bits are collected by the T7264 and changed on the K2 interface twice per superframe on K2 frames K47 (held until K94) and K95 (held until K46). The UCS bits are collected by the T7264 and changed on the K2 inter­face once per superframe on K2 frame K95 (held until K94). The DS octet is used to transfer device status from the T7264 to the K2 interface. The crc is automat­ically calculated in the T7264, and a single bit (nebe) in the DS octet provides indication of a crc error.

K2 Framing Bits

The four DF bits (the last 4 bits of the D octet on DO) indicate when the 2B+D data from the K2 interface and U-interface correspond. A system can monitor these signals to determine when the T7264 is transmitting or receiving specific data. RSF and TSF mark the first frame (K0) of a superframe. RF and TF add resolution in identifying the start of each U frame (every twelfth K2 frame). Figure 16 shows when eoc and UCS data is transferred to and from the K2 interface. It also indi­cates the occurrence of the RSF, TSF, RF, and TF bits. Notice that the DI and DO superframes are not aligned, and therefore RSF and TSF occur at different times.
RSF
RF
. . .
DO
K0 K1 K12 K47 K59 K60
RSF, RF
DI
2 K2
FRAMES
IN NT
K6 K94
TSF
TF
K0 K1 K12 K47 K59 K60
TSF, TF
K11 K48
. . .
. . .
K6 K94
. . .
NEW
eoc
K11 K48
. . .
eoc & UCS
MUST BE VALID
. . .
RF RFRF
. . .
TF TF TF
. . . K95
NEW eoc
& UCS
. . .
eoc
MUST BE VALID
. . . K95
5-5175

Figure 16. K2-to-U Mapping

Lucent Technologies Inc. 23
T7264 U-Interface 2B1Q Transceiver
Data Sheet
April 1998
K2 Functional Description (continued)
Figure 17 shows how the U-interface bits are grouped into eoc1, eoc2, UCS, and crc bits. It also shows how these bit groups are mapped from the U-interface to the K2 interface.
BIT #
FRAME # SYNC
1 2
3 4 5 6 7 8
* The U-inverted sync word (ISW) is mapped to the K2 interface as the receive superframe (RSF) bit and the transmit superframe (TSF) bit. The
occurrence of these bits defines the first K2 frame.
1—18 19—234
12(2B+D)
ISW*
U - SW K - RF, TF OUTPUT K0, K12, K24, . . . K84
U - 2B+D K - B1, B2, D
K0, K1, . . . K95
235 236 237 238 239 240
U - CONTROL & STATUS (UCS)
U - eoc1 K - UM1 & UM2 (#1—4) INPUT K11 OUTPUT K47—K94
U - eoc2 K - UM1 & UM2 (#1—4) INPUT K59 OUTPUT K95—K46
K - UM2 (#5—8) & UM3 INPUT K11 OUTPUT K95—K94
U - crc K - OUTPUT DS - #1 (nebe) K - INPUT DC - #1 (ccrc)
M6M5M4M3M2M1
5-5176

Figure 17. U-to-K2 Mapping

K2 eoc and Loopback Response Timing

Each U frame contains 12 2B+D data blocks. These blocks are jitter accommodated and synchronized within the T7264 and output on the K2 interface. This introduces delay between the U-interface and the K2 interface. The re­ceive and transmit framing on the U-interface do not occur at the same time. The ANSI standard specifies that the delay from U input to U output in the NT is 0.75 ms (6 K2 frames). The relationship between the K2 frame sync and the U-interface frame can change each time the device frames up.
The timing delay from receive to transmit affects the eoc timing as follows: The eoc is made available on the K2 interface at DO K2 frames K47 and K95, and it is sampled on DI K2 frames K59 and K11. This 11-frame difference plus the two-frame delay discussed above allows a total of 13 K2 frames (1625 µs) for the system to process the eoc information and respond. Thus, the system is guaranteed to have at least 1625 µs to respond to an eoc mes­sage. Figure 18 shows the received and transmitted K2 frame in the NT.
RECEIVED K2 FRAMES AT NT
& UCS
K95
2 K2
FRAMES
. . .
. . . . . . . . . . . . . . . . . .
1625 µs
K95
TRANSMITTED K2 FRAMES AT NT
K47 . . . . . .
NEW eocNEW eoc
K11. . . K59. . .K0
. . . . . . . . .
SAMPLE eoc & UCS
1625 µs
. . .
. . .. . .
. . .
SAMPLE eoc
5-5177

Figure 18. K2 Response Timing

24 Lucent Technologies Inc.
Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver
K2 Functional Description (continued)

K2 Device Status and Control Bits

The T7264 device status bits are transmitted over the K2 interface in the DS octet. The status information includes the nebe, xact, and oof bits which are used to determine the status of the line interface and to control the activate/deactivate state machine.
The T7264 device control bits are transmitted over the K2 interface in the DC octet. The control information includes the ccrc, istp, lpbk, afrst, ldea, and xpcy bits which provide the control necessary to implement the activation/deactivation state machine.
Tables 18 and 19 show how the DC bits are sampled and when the DS bits are available . Note that a Y in the column marked Hyst (hysteresis) indicates that the vali­dation occurs on both entry and exit from the condition. An N in the Hyst column indicates that the validation occurs only on entry into that condition. For validation, a signal must be present for three consecutive K2 frames.
In LT mode, setting the ldea (local deactivation) bit causes the transceiver to send 3 or 4 superframes of dea = 0 across the U-interface, save the adaptive filter coefficients, and cease transmission.
In the NT mode, the ldea bit is used to ensure that the transceiver is capable of a warm start on the next acti­vation; however, the transceiver must be given advance warning prior to loss of signal. This should be done by filtering dea = 0 for two superframe occur­rences prior to setting ldea = 1. This causes the trans­ceiver to freeze echo canceler coefficients. The transceiver then either deactivates upon detection of loss of signal or resumes training the echo canceler if ldea = 0 is received instead of detecting loss of signal.
In both LT and NT modes, the lpbk (local loopback) bit is used to request a local loopback within the trans­ceiver from the K2 input (DI) to the K2 output (DO). During loopback, the transceiver turns off the echo canceler (disables the canceler output from the summing node) and reconfigures the descrambler. To perform loopback, set afrst = 1 and lpbk = 1, discon­nect the U-interface metallic connection to the loop plant, then set afrst = 0 and lpbk = 0. Loopback has become valid when oof = 1. In order to terminate the loopback, set afrst = 1 and lpbk = 1. Reconnect the loop plant, then set afrst = 0. During the entire loop­back test, istp = 1 and xpcy may be either 0 or 1.

Table 18. DC Octet Description (Control)

Control (DC) Description Hyst Timing
ccrc bit Corrupt crc N Sample K2 frames 9, 10, 11 for three consecutive ccrc = true K2
frames. Continues to corrupt until the condition goes away.
istp Initiate Start-up N Sample for three consecutive K2 frames to validate.
ldea Local Deactivate Y Sample for three consecutive K2 frames to validate.
xpcy Transparency Y Sample for three consecutive K2 frames to validate.
afrst Reset Y Sample for three consecutive K2 frames to validate. lpbk Loopback Y Sample for three consecutive K2 frames to validate.

Table 19. DS Octet Description (Status)

Status (DS) Description Timing
nebe Near-end Block Error Presented to K2 interface on frame K95 to K94.
xact Transceiver Active Presented to K2 interface as it occurs.
oof Out of Sync Presented to K2 interface as it occurs.
Lucent Technologies Inc. 25
T7264 U-Interface 2B1Q Transceiver
Data Sheet
April 1998
K2 Functional Description (continued)

The adea Bit

The adea bit is only available when the MODE0 pin is set to 1 (LT mode). Setting adea = 0 causes the LT to set dea = 0 on the U-interface without deactivating itself. By contrast, setting ldea = 1 at the LT causes the LT to set dea = 0 on the U-interface, save adaptive filter coefficients, and deactivate itself after sending dea = 0 for three consec­utive U superframes.
In loop configurations with multiple U-interfaces, as shown in T1.601, adea is used to propagate dea = 0 beyond the local link (the link between the LT in an ISDN serving switch to the next NT downstream-type element of the loop) and can be used to deactivate a nonlocal link without deactivating the local link.
Table 20 shows the effects of the adea and ldea bits at the LT.

Table 20. adea, ldea, and dea Function

adea at LT ldea at LT Action
0 0 dea = 0 is sent downstream, but no local deactivation occurs. X 1 dea = 0 is sent downstream for 3 or 4 superframes, echo canceler coefficients are
frozen, and transmission ceases.
1 0 dea = 1 is sent downstream (normal operation).
26 Lucent Technologies Inc.
Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver
K2 Functional Description (continued)

The nebe, febe, rfebe, and ccrc Bits

Errors in the received 12-bit crc from the U-interface are indicated via the nebe (near-end block error) bit. The nebe bit is a local status bit that is set to 0 each time a crc error is detected. Errors in transmitted crc can be forced by setting the ccrc (corrupt crc) bit low. Because the crc error detection and corruption is handled via the nebe and ccrc bits, there is no need to have direct control or access to the 12 crc bits via the K2 interface.
Normally, the T7264 automatically reflects the nebe bit back to the far end as the ANSI-defined febe (far-end block error) bit. The MODE1 pin (pin 11) and rfebe bit can be used to alter the interaction between nebe and febe as shown in Figure 19. Normally, MODE1 and rfebe are HIGH, so febe is the direct result of the current state of nebe. Now rfebe can be directly used to control the state of febe.
The intended application for rfebe and MODE1 is one having multiple U links as shown in T1.601-1992, Figure E1. In this application, a performance monitoring approach called path performance monitoring can be used. This treats all links between the NT and LT as one complete link, or path. Thus, any febes or nebes that occur at an intermediate element should be propagated to an endpoint. In this way, the febe and nebe counts at the endpoints represent the performance of the system as a whole.
Figure 20 shows how a multilink system with one inter­mediate element (IE) could use MODE1, rfebe, nebe, febe, and ccrc to propagate crc errors to the endpoints. For simplicity, this figure represents only one direction of propagation of nebe and febe, namely nebes propa­gated toward the LT and febes propagated toward the NT. This circuitry would be duplicated in the opposite direction to form a complete system. At the endpoints, MODE1 = 1 and rfebe = 1, so nebe and febe behave normally. At IE, MODE1 = 0 so that rfebe, rather than nebe, controls the state of febe toward the far end. For clarity, the effect of MODE1 is shown as a coil control for an SPDT relay that selects either nebe or V upper input to the AND gate.
First, consider the case of a nebe occurring at the IE's LT-mode T7264. This means that a crc error occurred from NT to IE. The IE's K2 interface logic connects nebe directly to the ccrc bit of the NT-mode T7264 to force a ccrc error toward the LT. This will now show up as a nebe at the LT, effectively propagating nebe from IE to LT.
Now, at the LT, the nebe is reflected back toward the IE as a febe. At the IE, the K2 interface logic connects febe directly to the rfebe bit of the LT-mode T7264. This generates a febe from IE to NT, completing the path for the original crc error. Thus, the result of an error from NT to IE is a nebe reported at the LT and a febe report­ed at the NT. This illustrates how the two links and the IE are treated as a single entity from a performance monitoring standpoint.
CC as the
Lucent Technologies Inc. 27
T7264 U-Interface 2B1Q Transceiver
K2 Functional Description (continued)
Data Sheet
April 1998
2B+D+M
ccrc febe
K2 INTERFACE
NT
T7264 (NT)
crc
GENERATOR
crc
CHECKER
T7264 PIN #11
nebe
MODE1 rfebe

Figure 19. T7264 nebe/febe/crc Block Diagram

INTERMEDIATE ELEMENT
U-
INTER-
FACE
febe
T7264 (LT)
crc
CHECKER
nebe
rfebe
+V
K2 INTERFACE
LOGIC
2B+D+M
MODE1 = 0
T7264 (NT)
crc
GENERATOR
ccrc
febe
Figure 20. Use of rfebe in a Multilink Configuration
febe
U-
INTER-
FACE
febe
U-INTERFACE
LT
T7264 (LT)
crc
CHECKER
+V
rfebe
5-5178a
2B+D+M
nebe
MODE1 = 1 rfebe = 1
5-5179a

NT or LT Operation

The MODE0 pin determines whether the device is being used in an LT system as the originator of the U-interface signals or in the NT mode as the terminator of the U-interface signal. Table 21 is provided as a reference to show the different functions of the chip in NT and LT modes.

Table 21. MODE0 Pin Functionality

LT (MODE0 = 1) NT (MODE0 = 0)
U-interface timing derived from MTC K2 timing derived from the U-interface Transmit adea AND ldea for dea, uoa, aib Transmit ps1, ps2, ntm, cso, sai, nib U transmit-to-receive timing dependent upon line delay U transmit-to-receive timing fixed at 0.75 ms ldea stops transmission Loss of signal stops transmission LT scrambling algorithm NT scrambling algorithm LT start-up timing NT start-up timing TL tone generation TN tone generation TN tone recognition TL tone recognition
28 Lucent Technologies Inc.
Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver

Minimal Example

The simplest application of the T7264 in an NT1 is to assume only cold starts and always return an unable-to-com­ply for the eoc message. In this situation, the K2 interface signals are configured as shown in Table 22.

Table 22. Minimal Implementation

Note that this is only an example and not a valid T1.601 configuration. However, it could be useful for laboratory testing.
Bit Name Description Minimal State Description
B1, B2 ISDN 64 kbits/s B1, B2 Octet T Transparent
D ISDN 16 kbits/s D Bits T Transparent
Data In
a Address 000 NT Address
dm Data or Message 1 Message
i Information 10101010 Unable to Comply
act Activation INFO3 Transceiver Active
ps1, ps2 Primary/Sec. Power Status 1 Always True
rfebe Received Far-end Bit Error 1 Not Applicable
ntm NT in Test Mode 1 Never Used
cso Cold Start Only 1 Always Cold Start
R Reserved 1 Never Used
Data Out
dea Deactivation 1 Ignore ccrc Corrupt the Outgoing crc 1 Never Used
istp Initiate Start-up 0 Always Starting
lpbk Loopback 1 Never Used afrst Reset (Adaptive Filter Reset) 0 Never Used—RESET Pin Used ldea Local Deactivation 0 Never Used—Always Active
xpcy Transparency NOT act Received K2 act Bit
Lucent Technologies Inc. 29
T7264 U-Interface 2B1Q Transceiver
Data Sheet
April 1998

Activation and the K2 Interface

The signal definitions and start-up states (Table 23 and Figure 21) of the U-interface during activation are as re­quired by T1.601. The T7264 handles these details au­tomatically upon assertion of istp on the K2 interface or detection of a tone on the U-interface. Still, for some us­ers it is useful to know what is happening at the K2 in­terface during the start-up sequence and how the system should be reacting. The following is an explana­tion of what happens during a typical start-up sequence. For simplification, it is assumed that the uoa and sai bits, defined in T1.601-1992, are held at 1 during start­up.
1. From RESET to T6
At each end, xact changes from 0 to 1 to indicate that an activation request has been issued at the near end (via istp) or a wake-up tone has been detected from the far end and the transceiver is beginning the start-up se­quence. All other K2 bits are held in their reset state by the transceiver in the U-to-K2 direction at both the NT and the LT (see Table 15 for these RESET values). In the K2-to-U direction, the 2B+D and U overhead bits are internally overwritten by the transceivers. These bits should be initialized by the system to reflect their de­sired state at the time transparency is achieved. Table 23 lists the values of the overwritten U bits at various stages of activation.
2. At T6
At the NT, oof goes high causing 2B+D transparency from the U to the K2 interface at the NT transceiver. Note that the NT always frames up before the LT, due to the structure of the transceiver start-up algorithms. Before T6, the NT transceiver was forcing 2B+D data on the K2 interface to all 1s. After this, the 2B+D bits on the K2 interface contain whatever is being received at the NT's U-interface on the 2B+D channels from T4 until transparency is established (see Table 23 and Figure 21, signal SL2).
M bits in the downstream direction become transparent over the entire link. Prior to this, the NT transceiver was forcing all M bits to 1 in the downstream (U-to-K2) direc­tion, except act, which was being forced to 0. In the downstream direction (K2-to-U) at the LT, M bits are al­ready being passed transparently and have been since T4. At T6, oof = 1 at the NT causes the NT to start pass­ing M bits transparently in the downstream direction.
M bits in the upstream direction become transparent at the NT transceiver (K2-to-U). Prior to this, the NT trans­ceiver was internally overwriting the upstream M bits to all 1s per the ANSI standard (see Table 23 and Figure 21, signal SN2).
After detecting oof = 1, the NT can set its act = 1, then wait for act = 1 from the LT. The NT is still forcing 2B+D in the upstream direction to all 1s and continues to do so until:
a) It receives act = 1 from the LT b) It receives an eoc loopback message from the LT When either of the above occurs, the NT must set
xpcy = 0, which enables 2B+D transparency in the up­stream direction.
3. At T7
At the LT, oof goes high causing 2B+D transparency from the U to the K2 interface at the LT transceiver. Be­fore T7, the LT transceiver was forcing 2B+D data on the K2 interface to all 1s. After this, the 2B+D bits on the K2 interface contain whatever is being received at the LT's U-interface on the 2B+D channels. This is all 1s ini­tially, because the NT transceiver at the far end is forc­ing transmission of all 1s on the U-interface 2B+D channels from T1 until the transparency is established (see Table 23 and Figure 21, signal SN1—SN3).
M bits in the upstream direction become transparent over the entire link. Prior to this, the LT transceiver was forcing all the M bits to 1 in the upstream (U-to-K2) di­rection, except act, which was being forced to 0. In the upstream (K2-to-U) direction at the NT, M bits are al­ready being passed transparently and have been since T6. At T7, oof = 1 at the LT causes the LT to start pass­ing M bits transparently in the U-to-K2 direction and, thus, affects full M-bit transparency in the upstream di­rection.
Since the LT is receiving M4 bits from the NT, it can de­tect when the NT has changed its act bit from 0 to 1. Af­ter getting act = 1 three consecutive times from the NT, the LT may set its xpcy = 0 and act = 1, resulting in 2B+D transparency in the downstream direction over the entire link. Prior to this, the LT transceiver was inter­nally overwriting the downstream 2B+D data to all 0s per T1.601.
3030 Lucent Technologies Inc.
Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver
Activation and the K2 Interface (continued)
the NT, the LT must set xpcy = 0. Now, transparency is established over the entire link without having set the
There is one case in which the LT never receives act = 1 from the NT. If the LT is connected to an NT1, which has no TE controlling it, the NT can never send act = 1. T1.601 (Section 6.4.6.6) states that transparency required to perform loopbacks must be provided when loopbacks are requested, even when the NT is not sending act = 1. In this case, the LT, once it has received oof = 1, must transmit the proper eoc message
act bits to 1. Upon receiving act = 1 three consecutive times from
the LT, or upon receiving an eoc loopback message as discussed above, the NT sets its xpcy = 0, affecting 2B+D transparency in the upstream direction over the entire link. Prior to this, the NT transceiver was inter­nally overwriting the upstream 2B+D data to all 1s per T1.601. The link is now fully operational.
to enable the desired remote loopback. The NT1 must set its xpcy = 0 in response to the eoc loopback message. Upon receiving the echoed message from
Table 23. Definitions of Signals During Start-Up
Signal Sync Word
(SW)
TN ±3* ±3* ±3* ±3*
Superframe
(ISW)
2B+D M Start Stop Time
SN1 Present Absent 1 1 T1 T2 — SN2 Present Absent 1 1 T5 T6 — SN3 Present Present
Normal
+
Normal T6
TL ±3* ±3* ±3* ±3*
SL1 Present Absent 1 1 T3 T4 — SL2 Present Present 0 Normal T4 T7 — SL3 Present Present
Normal
Normal T7
(Frames)
6
2
* Tones have alternating pattern of four +3s, followed by four –3s, and no SW. † See Figure 21 for start and/or stop time of this signal. ‡ Signals SN3 and SL3 continue indefinitely (or until deactivation).
Notes: TN, TL — Tones produced by NT or LT, respectively. SNx, SLx — Pulse patterns produced by NT or LT, respectively. Tx — Notation refers to transition instants defined in Figure 21. Absent — Under superframe, this notation means that only SW is transmitted, not ISW. Normal — Normal means that the M bits are transmitted onto the 2-wire line as required during normal operation (e.g., valid crc bits, eoc
Normal+— Except to perform a loopback, 2B+D bits remain in the previous state (SN2 or SL2) until both act bits indicate full transparency
bits, and indicator bits are transmitted).
of the B- and D-channels (i.e., the 2B+D bits of SN3 and SL3 must remain set to 1 and 0, respectively, until transparency is achieved at both ends of the DSL).

Priority

Priorities exist for responding to several signals as follows:
1. RESET
2. afrst
3. ILOSS
4. tone detection
5. istp
6. lpbk
Lucent Technologies Inc. 31
T7264 U-Interface 2B1Q Transceiver
Activation and the K2 Interface (continued)
AB C D
Data Sheet
April 1998
4 ms
T2
T0
FRAMES
NT NETWORK
TL
2 FRAMES
Notes: T0 Reset state.
T1 Network and NT are awake. T2 NT discontinues transmission, indicating that the NT is ready to receive signal. T3 Network responds to termination of signal and begins transmitting signal toward the NT. T4 Network begins transmitting SL2 toward the NT, indicating that the network is ready to receive SN2. T5 NT begins transmitting SN2 toward the network, indicating that NT has acquired SW frame and detected SL2. T6 NT has acquired superframe marker, and is fully operational. T7 Network has acquired superframe marker, and is fully operational.
T1
6
TN SN1
(OP-
TIONAL)
NTNETWORK
480 ms
T3
SL1 (OPTIONAL) SL2 SL3
A + C 5 s FOR COLD START A + C 150 ms FOR WARM START B + D 10 s FOR COLD START B + D 150 ms FOR WARM START
T5
SN2 SN3
T6 T7T4
5-5180

Figure 21. State Sequence for DSL Transceiver Start-Up

Applications

The T7264 is intended for use in both switch and customer premises equipment including a central office (CO), a private branch exchange (PBX), a 2-wire to 4-wire converter (NT1), and terminal equipment (TE). The physical ter­mination of the U-interface at the network end is referred to as the line termination (LT); the physical termination at the user end is referred to as the network termination (NT). Figure 22 shows a loop configuration using several U­interface devices at various locations.
The T7264 provides system access to the U loop through the K2 interface. The K2 interface is a TDM serial interface which provides access to 2B+D data, U-interface maintenance, and T7264 device control/status.
Figure 23 shows a 2-wire terminal application with the T7264 providing the U-interface. The T7270 provides the microprocessor with access to the individual octets of the K2 data stream. The B1 and B2 data could be transferred to either a codec for voice communications, such as the T7513A, or to an HDLC controller for data communications, such as the T7121. Another T7121 could provide microprocessor access to D-channel HDLC processing. The microprocessor would control initialization, activation/deactivation, D-channel processing, and maintenance func­tions.
32 Lucent Technologies Inc.
Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver
Applications (continued)
Figure 24 shows a digital pair gain application with the T7264 providing the U-interface. In this system, the U-inter­face is used as a digital pipe to multiplex two analog voice lines onto the B channels. Thus, one twisted pair can provide two analog lines. The T7270 forms the interface between the microprocessor, the K2 bus, and the codecs. The T7121 can be used for HDLC formatting on the B or D channels to provide enhanced features. The divider pro­vides the 2.048 MHz clock for the codecs, which are interfaced to the TSI via its CHI ports. The codecs and battery feeds provide the analog interface to the telephones.
2-WIRE 2B1Q U-INTERFACE
T7264
U
NT
PBX or NT1
4-WIRE S/T
2-WIRE 2B1Q U-INTERFACE
U
NT
2-WIRE 2B1Q U-INTERFACE

Figure 22. Loop Application

CHI
T7270
K2
MICRO-
PROCESSOR

Figure 23. 2-Wire Terminal Application

U
LT
SWITCH
U
LT
DB1B2
T7121
HDLC
T7121 HDLC
T7513B CODEC
DATA
5-5181
HANDSET
5-5182
U-INTERFACE
TRANSFORMER/
PROTECTION
2754H/
521A
MAINTENANCE
MONITOR TERMINAL
ASYNC DATA PORT
10.24 MHz
DIVIDER
2.048 MHz
FOR
K2 INTERFACE
2B1Q
T7264
TSI
T7270
HIFI-64
T7121
MICROPROCESSOR
RS232C
CHI
CODEC
CODEC T7513B
4TH CHI
ANALOG INTERFACE
BATTERY FEED
BATTERY FEED
LB1276AF
5-5183

Figure 24. Digital Pair Gain Application

Lucent Technologies Inc. 33
T7264 U-Interface 2B1Q Transceiver
Data Sheet
April 1998

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso­lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of this data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability.
Parameter Min Typ Max Unit
Storage Temperature –55 125 °C Lead Temp (soldering or bonding) 300 °C Any Pin to GND –0.5 6.5 V Power Dissipation (package limit) 700 mW

Handling Precautions

Although protection circuitry has been designed into this device, proper precautions should be taken to av oid expo­sure to electrostatic discharge (ESD) during handling and mounting. Lucent employs a human-body model (HBM) and charged-device model (CDM) for ESD-susceptibility testing and protection design evaluation. ESD voltage thresholds are dependent on the circuit parameters used to define the model. No industry-wide standard has been adopted for the CDM. However, a standard HBM (resistance = 1500 , capacitance = 100 pF) is widely used and, therefore, can be used for comparison. The HBM ESD threshold presented here was obtained by using these cir­cuit parameters:
ESD Threshold Volta ge
Device V oltage
T7264-ML >500

Recommended Operating Conditions

Parameter Symbol Test Conditions Min Typ Max Unit
Ambient Temp TA VDD = 5 V ± 5% –40 85 °C Any VDD VDD 4.75 5.0 5.25 V GND to GND VGG –10 10 mV Voltage Ref Capacitor CVR 0.08 0.1 0.2 µF Master Clock Frequency MCLK 15.36 MHz Master Clock Tolerance MCLK NT Mode
LT Mode
Master Clock Duty Cycle MCLK
* To meet ANSI T1.601 free-run line rate requirement, NT tolerance is 100 ppm. † x = tolerance of MTC.
–225*
–225 + x*
47
— —
53 %
225*
225 – x*
ppm
ppm
34 Lucent Technologies Inc.
Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver

Electrical Characteristics

All characteristics are for a 15.36 MHz crystal, 135 line load, random 2B+D data, VDD = 5 V ± 0.25 V, –40 °C to +85 °C, output capacitance = 50 pF.

Table 24. Power Consumption

Parameter Test Conditions Min Typ Max Unit
Power Consumption Operating, Random Data 275 350 mW Power Consumption Powerdown Mode 30 50 mW

Table 25. Performance Ratings

Parameter Test Conditions Min Typ Max Unit
Warm Start Time 200 ms Cold Start Time 3.5 s Error Rate over 18 kft 26 AWG cable

Table 26. Crystal Characteristics: Fundamental Mode Crystal

These are the characteristics of a crystal for meeting the ±100 ppm requirements of T1.601 for NT operation.
10
–7
Parameter Symbol Test Conditions Specifications Unit
Center Frequency FO With 25.0 pF of loading 15.36011 MHz Tolerance Including Calibration,
Temperature Stability, and Aging Drive Level DL Maximum 0.5 mW Series Resistance RS Maximum 20 Shunt Capacitance CO 3.0 ± 20% pF Motional Capacitance Cm 12 ± 20% fF
The parasitic capacitance of the PC board to which the T7264 crystal is mounted must be kept within the range
0.6 ± 0.4 pF. For LT operation or for NT applications that can tolerate a free-running frequency tolerance of up to ±150 ppm, T OL
and Cm may be relaxed as long as they satisfy the following: | TOL + (3300 ppm) x Cm (in pF) | 150 ppm using the nominal value of Cm. All other parameters are unchanged except that the shunt capacitance, CO, should
change in proportion with any change in Cm. Possible sources for 15.36 MHz crystals for use with the T7264 include:
CTS Knights MTRON* Saronix
Tom Haney at 1-704-684-0242
P/N 020-2807-0
* MTRON is a registered trademark of MTRON Industries, Inc., a wholly owned subsidiary of Lynch Corporation. (Lynch is a registered trade-
mark of Lynch Corporation.)
(Winch Sales Associates)
at 1-908-613-1515
TOL ±60 ppm
William J. Winch
P/N 4044-001
For LT applications, a relaxed specification part is avail­able where TOL = ±85 ppm and Cm = 18 fF ±20%. P/N SRX5152(–N [no vinyl coating])
Laura Derrickson at 1-800-227-8974
(in CA, 1-800-422-3355
P/N SRX5144(-N)
Lucent Technologies Inc. 35
T7264 U-Interface 2B1Q Transceiver
Data Sheet
April 1998
Electrical Characteristics (continued)

Table 27. Internal PLL Characteristics

Parameter Test Conditions Min Typ Max Unit
Total Pull Range ±250 ppm Jitter Transfer Function –3 dB point (LT)
–3 dB point (NT), 18 kft 26 AWG
Jitter Peaking at 0.15 Hz typical (LT)
at 1.5 Hz typical (NT)
* Set by digital PLL; therefore, variations track MTC (LT mode) or U-interface line rate (NT mode).

Table 28. Digital dc Characteristics (Over Operating Ranges)

Parameter Symbol Test Conditions Min Typ Max Unit
Input Leakage Current:
Low High Low High
Input Voltage:
Low High Low-to-High Threshold High-to-Low Threshold Low High
Output Leakage:
Low High
Output Leakage:
Low , TTL
High, TTL
IIL
IIH
IILpu
IIHpu
VIL
VIH VILs VIHs VILc VIHc
IOZL
IOZH
VOL
VOH
VIL = 0 (pin 1, 2)
VIH = VDD (pin 1, 2)
VIL = 0 (pins 7—11, 14—15, 24—26)
VIH = VDD (pins 7—11, 14—15, 24—26)
All Pins Except Pin 7, 10, 11, 24 All Pins Except Pin 7, 10, 11, 24
Pin 7
Pin 7 Pins 10, 11, 24 Pins 10, 11, 24
VOL = 0; Pin 26 = 0
VOH = VDD; Pin 26 = 0
IOL = 1.6 mA, Pins 3, 4, 5, 16
IOL = 3.3 mA, Pin 43
IOL = 6.5 mA, Pins 13, 23
IOH = 2.4 mA, Pins 3, 4, 5, 16
IOH = 5.1 mA, Pin 43
IOH = 10.4 mA, Pins 13, 23
— —
— —
–10
–52
2.0
VDD – 0.5
— —
0.7 VDD
10
— — —
2.4
2.4
2.4
0.45*5*— —
0.4*
1.0*
— —
— — — —
— — — — — —
— —
— — — — — —
10
–10
10
0.8 — —
0.5
0.2 VDD
–10
0.4
0.4
0.4 — — —
Hz Hz
dB dB
µA µA µA µA
V V V V V V
µA µA
V V V V V V

Loop-Range Performance Characteristics

The T7264 transceiver is designed to allow systems to meet the loop-range requirements of ANSI Standard T1.601­1992 when the transceiver is used with the proper peripheral circuitry.
The line driver provides pulses that produce the 2.5 V template required of the T1.601 specification when connected to the proper transformer and interface circuitry.
36 Lucent Technologies Inc.
Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver

Timing Characteristics

Output Capacitance = 50 pF, TA = –40 °C to +85 °C, VDD = 5 V ± 5%, GND = 0 V, crystal frequency = 15.36 MHz.

Table 29. Clock Timing (See Figures 25, 26, and 28.)

Symbol Parameter Min Typ Max Unit
F 8 kHz Duty Cycle 49.8 50.2 % C 512 kHz Duty Cycle 46 54 %
RCLKEN 80 kHz Duty Cycle 48 52 %
CKOUT Duty Cycle:
In 7.68 MHz Mode In 15.36 MHz Mode
45
40 Pulse Width (high) In 10.24 MHz Mode
23*
tR1, tF1 Rise or Fall Time 30 ns
tCHFH, tFHCH Clock (C) High to Frame Sync (F) –15 15 ns
tRCHRCH CKOUT Clock to RCLKEN Clock Enable 25 ns
tCOLFH CKOUT Clock to Frame Sync (F) 50 ns
tDIVCL, tCLDIZ Receive Data (DI) Setup & Hold Time 50 ns
tCHDOV Clock (C) High to Data (DO) Valid 50 ns
tR2, tF2 CKOUT Clock Rise or Fall 15 ns
tCHOSV Clock (C) High to Out of Sync OSYNC Valid 60 ns
*Includes the effect of phase steps generated by the digital phase-locked loop.
— —
55 60
52*
% %
%
CKOUT
RCLKEN
DO
OSYNC
F
C
F
C
DI
tCHDOV
tCHFH
tFHCH
tCOLFH
tRCHRCH
tDIVCL
tF1 tR1
tF2tR2
tF1 tR1

Figure 25. Timing Diagram Referenced to F

tCLDIZ
BIT 1
BIT 1 OF B1 DATA
tCHOSV
tDIVCL

Figure 26. Timing Diagram Referenced to C

tF1
5-5184
tCLDIZ
BIT 2
BIT 2 OF B1 DATA
5-5185
Lucent Technologies Inc. 37
T7264 U-Interface 2B1Q Transceiver
Data Sheet
April 1998
Timing Characteristics (continued)
Table 30. MTC Requirements and Characteristics* (LT Mode)
Parameter Min Typ Max Unit
MTC Clock Period 125 – 32 ppm 125 125 + 32 ppm µs MTC High/Low Time 8 MCLKs MTC Rise/Fall Time 60 ns MTC Jitter 0.259
* To meet ANSI T1.601-1992, see note for Recommended Operating Conditions.
One UI = 12.5 µs.

Table 31. RESET Timing (See Figures 27 and 28.)

Symbol Parameter Min Max Unit
tRSLFL, tFLRSH RESET Setup and Hold Time 60 ns
tRSLRSH RESET Low Time:
From Idle Mode or Normal Operation From Power On
3
1.5
— —
UI
K2 frames
ms
F
tRSLFL
RESET
(RS)

Figure 27. RESET Timing Diagram

Switching Test Input/Output Waveform

2.4 V
0.4 V
2.0 V
0.8 V

Figure 28. Switching Test Waveform

tFLRSH
tRSLRSH
5-5186
2.4 V
2.0 V
TEST POINTS
0.8 V
0.4 V
5-5187
38 Lucent Technologies Inc.
Data Sheet April 1998

Outline Diagram

Dimensions are in millimeters.
T7264 U-Interface 2B1Q Transceiver
17.65 MAX
16.66 MAX
PIN #1 IDENTIFIER
7
17
18 28
ZONE
1640
39
16.66 MAX
17.65 MAX
29
4.57 MAX
SEATING PLANE
0.10
5-2506
1.27 TYP
Notes: Meets all JEDEC standards.
Pin 1 index mark may be a dimple or numeric located in zones indicated.
0.53 MAX
0.51 MIN TYP

Ordering Information

Code Package Temperature Comcode
T7264A- -ML-D 44-pin PLCC –40 °C to +85 °C 107890170
T7264A- -ML-DT 44-pin PLCC –40 °C to +85 °C 107997124
Lucent Technologies Inc. 39
T7264 U-Interface 2B1Q Transceiver
Data Sheet
April 1998

Appendix A. Questions and Answers

Introduction

The questions and answers are divided into three cate­gories: U-interface, K2 interface, and miscellaneous.
For detailed application information, also refer to the application notes Implementation of an ANSI Standard ISDN NT1 Using the Lucent T7262A/63, T7252A, T7270, and an 8-Bit Microcontroller and Performance Factors in Line-Powered 2B1Q Applications.

U-Interface

Q1: Is the line interf ace for the T7264 the same as the
T7262A/63?
A1: The interface is different in that the T7262A/63
uses a Lucent 2754G transformer (2.5:1 turns ratio), and the T7264 uses a Lucent 2754H trans­former (1.5:1 turns ratio).
Other changes to the line interface include device-side resistors of 16.9 ± 1% and line-side resistors of 16.9 ± 7%. Part of the line-side resistance will likely be a PTC in those applica­tions requiring power cross protection.
The T7264 device-side protection is unchanged (521A diodes), and the dc blocking capacitor is unchanged (Illinois Capacitor* 1.0 µF ± 5%).
Line-side protection must be tailored to individual system needs.
Q2: Why is a higher transformer magnetizing
inductance used (as compared to other vendors)?
Q3: Can the T7264 be used with a transformer that
has a magnetizing inductance of 20 mH?
A3: The echo canceler and tail canceler are
optimized for a transformer inductance of approx­imately 80 mH and will not work with a value this low.
Q4: Are the Lucent U-interf ace transf ormers av ailable
as surface-mount components?
A4: Not at this time. Q5: Are there any future plans to make a smaller
height 2-wire transformer?
A5: Due to the rigid design specifications for the
transformer, vendors have found it difficult to make the transformer any smaller. We are con­tinuing to work with transformer vendors to see if we can come up with a smaller solution.
Q6: The line interface components’ specifications
require 16.9 resistors on the line side of the transformer. We would like to change this value for our application. Can the U-interface line-side circuit be redesigned to change the value of the line-side resistors?
A6: Yes. For example, the line-side resistances can
be reflected back to the device side of the trans­former so that, instead of having 16.9 on each side of the transformer, there are no resistors on the line side of the transformer and 24.4 resis­tors on the device side (16.9 + 16.9/N2, where N is the turns ratio of the transformer). However, there may be some performance penalty in this case since the on-chip hybrid network is opti­mized for 16.9 of resistance on the device side of the transformer.
A2: It has been determined that a higher inductance
provides better linearity . Furthermore, it has been found that a higher inductance at the far end pro­vides better receiver performance at the near end and better probability of start-up at long loop lengths.
* Illinois Capacitor is a registered trademark of Illinois Capacitor Inc.
4040 Lucent Technologies Inc.
Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver
Appendix A. Questions and Answers
(continued)
Q7: Why are the line-side resistors (16.9 ) rated at
7% tolerance in Figure 4 of the data sheet?
A7: This tolerance was determined based on
analysis of the output voltage tolerance of the T7262A/63 solution as compared to the T7264 solution, taking into account the tolerances of the transformer, resistors, etc. It is not a standard resistor tolerance, such as 5%, because as much flexibility as possible was desired. The 16.9 resistor is often a combination of a resistor and a positive temperature coefficient (PTC) surge­protection resistor, and PTCs generally have wider tolerances.
Some 2B1Q manufacturers try to match the PTCs in such a way that their variations from the nominal value are in the same direction. How­ever, it is important to use as tight a tolerance as possible for the following reasons:
The 16.9 resistor is also part of the termina-
tion impedance looking into Tip/Ring. ANSI specifies this impedance at 135 nominal, and the impedance template over the specified frequencies is derived from the return loss requirement (T1.601, Sections 7.1, 7.2, and Figure 19). A tighter tolerance on the 16.9 resistors allows more margin on the return loss template.
If resistors are unmatched, longitudinal balance
(described in T1.601, Section 7.3) may be affected. Designers can experimentally deter­mine the maximum tolerance allowed in their system by varying the 16.9 resistors slightly and observing the effect on the parameters mentioned above.
Q9: The application diagram in the data sheet shows
the loopback relay on the line side of the trans­former. Why is it not shown on the device side?
A9: The relay can be located on the device side
between the 521A surge protector and the trans­former, and the local loopback will function prop­erly. It is shown on the line side because in many applications the relay is a DPDT type and is also used for metallic access to some line testing equipment (at an LT, for example).
Q10: If the relay is on the line side, what type should it
be?
A10: Relay type is application-dependent. An e xample
of a relay which would work in most cases is an Aromat* DS Series 2 A relay.
Q11: Clarify the meaning of the note concerning the
3000 pF capacitors in the U-line interface figure (Figure 4).
A11: The capacitors are not absolutely required. The
ANSI T1.601 specification contains no require­ments on longitudinal noise immunity. Therefore, these capacitors are not required in order to meet the specification. However, there are guidelines in IEC 801-6 which suggest a noise immunity of up to 10 Vrms between 150 kHz and 250 MHz. At these levels, the 10 kHz tone detector in the T7264 may be desensitized such that tone detec­tion is not guaranteed on long loops. The 3000 pF was selected to provide attenuation of this common-mode noise so that tone detector sensitivity is not adversely affected. Since the 3000 pF capacitor was selected based only on guidelines, it is not mandatory, but it is recom­mended in applications which may be susceptible to high levels of common-mode noise. The final decision depends on the specific application.
Q8: The dc bloc king capacitor specified is 1 µF. Can it
be increased to at least 2 µF?
A8: Yes. This value can be increased without any det-
rimental effect.
* Aromat is a registered trademark of Aromat Corporation.
Lucent Technologies Inc. 41
T7264 U-Interface 2B1Q Transceiver
Data Sheet
April 1998
Appendix A. Questions and Answers
(continued)
Q12: Why must secondary protection, such as the
521A protection diode, be used?
A12: The purpose of the 521A is to protect against
metallic surges below the breakdown level of the primary protector.
Such metallic surges will be coupled through the transformer and could cause device damage if the currents are high. The 521A does not provide absolute protection for the device, but rather works in conjunction with the built-in protection on the device leads.
The breakdown voltage level for secondary pro-
tection devices must be chosen to be above the normal working voltage of the signal and typically below the breakdown voltage level of the next stage of protection. The 521A has a minimum breakdown voltage level of 6.95 V and a maxi­mum breakdown voltage of 8.0 V.
The chip pins which the 521A protects are
pins 36 (HP), 31 (HN), 32 (LOP), and 35 (LON). The 16.9 resistors will help to protect pins 32 and 35, but pins 31 and 36 will be directly exposed to the voltage across the 521A. The on­chip protection on these pins consists of output diodes and a pair of polysilicon resistors. These pins have been thoroughly tested to ensure that an 8 V level will not damage them; therefore, no third level of protection is needed between the 521A and the HP and HN pins.
The 521A has a maximum reverse surge voltage level of 10 V at 50 A. Sustained currents this large are not a concern in this application, since it is assumed that some form of primary protection is being used, such as the Teccor* P2103AA SIDACtor*. Thus, there should never be more than 8.0 V across the 521A, except for possibly an ESD or lightning hit. In these cases , the T7264 is able to withstand at least ±500 V (human-body model) on its pins.
Another consideration is the capacitive loading that the protection device presents to the target device. This is generally required to be negligible at the operating frequency.
From a practical point of view, the device is chosen to meet not only voltage, current, and capacitance requirements, but also to meet price, availability, manufacturing, and second­sourcing requirements. The 521A device is a general-purpose device that meets system requirements for voltage, current, capacitance, price, etc., for some of Lucent’ s customers. Other devices which may be acceptable alternates are as follows: Motorola† SA6.0C (through-hole and surface-mount), Microsemi SMSJ6.0C-SMB (sur­face-mount), and SGS-Thomson‡ SM6T6V8C (surface-mount).
Q13: Bellcore TR-TSY-000078, Section 3.2.4.1, prohib-
its using silver metallization, but the 521A protec­tion diodes have silver-plated leads. Does this indicate an incompatibility problem?
A13: Bellcore TR-TSY-000078, Section 3.2.4.1 prohib-
its silver “. . . when electromig r ation is a problem.” The 521A diodes are only used as secondary protection, and, therefore, almost ne ver carry any current. Electromigration occurs only when there is a high current flow for an extended period of time. Since the diodes are ne v er subjected to this condition, electromigration is not a problem, and the silver plating is acceptable.
Q14: Where can information be obtained on lightning
and surge protection requirements for 2B1Q products?
A14: ANSI T1.601, Appendix B, provides a list of
applicable specifications to which you may refer. Also, there are many manufacturers of overvolt­age protection devices who are familiar with the specifications and would be willing to assist in surge protection design. The ITU-T K series recommendations are also a good source of information on protection, especially Recommen­dation K.11, “Principles of Protection Against Overvoltages and Overcurrents,” which presents an overview of protection principles.
* Teccor and SIDACtor are trademarks of Teccor, Inc. † Motorola is a registered trademark of Motorola, Inc. ‡ SGS-Thomson is a registered trademark of SGS-Thomson
Microelectronics, Inc.
4242 Lucent Technologies Inc.
Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver
Appendix A. Questions and Answers
(continued)
Q15: ITU-T specification K.21 describes a lightning
surge test for NT1s (see Figure 1/K.21 and Table 1/K.21, Test #1) in which both Tip and Ring are connected to the source and a 1.5 kV voltage surge is applied between this point and the GND of the NT1. What are the protection consid­erations for this test? Are the HP and HN pins susceptible to damage?
A15: The critical component in this test is the trans-
former since its breakdown voltage must be greater than 1.5 kV. Assuming this is the case, the only voltage that will make it through to the secondary side of the transformer will be prima­rily due to the interwinding capacitance of the transformer coils.
This capacitance will look like an impedance to the common-mode surge and will therefore limit current on the device side of the transformer . The device-side voltage will be clamped by the 521A device. The maximum breakdown voltage of the 521A is 8 V. The 16.9 resistors will help protect the LOP and LON pins on the T7264 from this voltage. However, this voltage will be seen directly on pins 36 and 31 (HP and HN) on the T7264. The on-chip protection on these pins con­sists of output diodes and a pair of polysilicon resistors. These pins have been thoroughly tested to ensure that an 8 V lev el will not damage them; therefore, no third level of protection is needed between the 521A and the HP and HN pins.
Q16: How is it possible to guarantee the ±0.35 dB
power spectrum tolerance on the U-interface?
A16: By trimming to ±0.1 dB; the rest of the variation is
for power supply, temperature, and aging.
Q17: Is the ±100 ppm free-run frequency (NT mode)
recommendation met in the T7264?
A17: In the free-run mode, the output frequency is
primarily dependent upon the crystal, not the sili­con design. For low-cost crystals, initial toler­ance, temperature, and aging effects may account for two-thirds of this budget, and just a couple of pF of variation in load capacitance will use up the rest. Thus, the ±100 ppm goal can be met if the crystal parameters are well controlled. See the Crystal Characteristics information in the data sheet (Table 26).
Q18: It has been noted in some other designs that the
crystal has a capacitor from each pin to ground. Changing these capacitances allows the fre­quency to be adjusted to compensate for board parasitics. Can this be done with the T7264 crys­tal? Also, can we use a crystal from our own manufacturer?
A18: The crystal for the T7264 is tuned to a particular
load capacitance that does not include external capacitors. The advantage to this is that no exter­nal components are required. The disadvantage is that board parasitics must be very small. The data sheet notes that the board parasitics must be within the range of 0.6 pF ± 0.4 pF. Lucent does not require that a particular crystal be used, but we strongly recommend adhering to the crys­tal parameters specified in the data sheet. A crystal which deviates from these parameters can work under most conditions, but we cannot guarantee that it will start up and/or meet the ±100 ppm requirement under all operating condi­tions.
Q19: Is there a test pin availab le f or generating a +3/–3
sequence so that pulse templates can be measured easily?
A19: There is no such pin. But a sequence of four +3s,
followed by four –3s (and so on) is the 10 kHz wakeup tone (TN, TL in ANSI T1.601, Figure 17) that each transceiver outputs when initiating a start-up. This tone is produced when the K2 bit, istp in the dc octet, is asserted. At the NT, this tone lasts for 9 ms (90 pulses), and at the LT, it lasts for 3 ms (30 pulses). This should be long enough to capture the data on a digitizer or stor­age scope for analysis.
Q20: What are the average cold start and warm start
times?
A20: Lab measurements have shown the average cold
start time to be about 3.3 s—4.2 s over all loop lengths, and the average warm start time to be around 125 ms—190 ms over all loop lengths.
Q21: What is the U-interface’s response time to an
incoming wakeup tone from the LT?
A21: Response time is about 1 ms. Q22: What is the minimum time for a U-interface
reframe after a momentary (<480 ms) loss of synchronization?
A22: Five superframes (60 ms).
Lucent Technologies Inc. 43
T7264 U-Interface 2B1Q Transceiver
Data Sheet
April 1998
Appendix A. Questions and Answers
(continued)
Q23: Can the range of the T7264 on the U-interf ace be
specified in terms of loss? What is the range for over straight 24 AWG wire?
there may be shorter loops which could cause start-up problems if the transceiver algorithm is not robust. The T7264 has been tested on all of the ANSI loops per the T1.601 standard and passes them all successfully. Two loops com­monly used in the lab to evaluate the perfor­mance of the T7264 silicon are as follows:
A23: ANSI Standard T1.601, Section 5.1, states that
transceivers meeting the U-interface standard are intended to operate over cables up to the limits of 18 kft (5.5 km) 1300 resistance design. Resis­tance design rules specify that a loop (of single­or mixed-gauge cable; e.g., 22 AWG, 24 AWG, and 26 AWG) should have a maximum dc resis­tance of 1300 , a maximum working length of 18 kft, and a maximum total bridged tap length of
Loop Config­uration
18 kft
26 AWG
15 kft
26 AWG
Bridge Taps
(BT)
None 38.7 49.5
2 at near end,
each 3 kft,
22 AWG
Loss @
20 kHz
(dB)
37.1 46.5
Loss @
40 kHz
(dB)
6 kft.
The standard states that, in terms of loss, this is equivalent to a maximum insertion loss of 42 dB @ 40 kHz. Lucent has found that, for assessing the condition of actual loops in the field in a 2B1Q system, specifying insertion loss as
33.4 dB @ 20 kHz more closely models ANSI circuit operation. This is equivalent to a straight 26 AWG cable with 1300 Ω dc resistance (~15.6 kft).
The above goals are for actual loops in the out­side loop plant. These loops may be subjected to noise and jitter. In addition, as mentioned above, there may be bridge taps at various points on the loop. The T1.601 standard defines 15 loops, plus the null, or 0 length loop, which are intended to represent a generic cross section of the actual loop plant.
A 2B1Q system must perform over all these loops in the presence of impairments with an error rate of <1e–7. Loop #1 (18 kft, where 16.5 kft is 26 AWG cable and 1.5 kft is 24 AWG cable) is the longest, and so has the most loss (37.6 dB @ 20 kHz and 47.5 dB @ 40 kHz). Note that this is more loss than discussed in the preceding para­graph. The difference is based on test require­ments vs. field deployment. The test requirements are somewhat more stringent than the field goal in order to provide some margin against severe impairments, complex bridged taps, etc.
If a transceiver can operate over Loop #1 error­free, it should have adequate range to meet all the other loops specified in T1.601. Loop #1 has no bridged taps, so passing Loop #1 does not guarantee that a transceiver will successfully
The T7264 is able to start up and operate error­free on both of these loops. Neither of these loops is specified in the ANSI standard, but both are useful for evaluation purposes. The first loop is used because it is simple to construct and easy to emulate using a lumped parameter cable model, and it is very similar to ANSI Loop #1, but slightly worse. Thus, if a transceiver can start up on this loop and operate error-free, its range will be adequate to meet the longest ANSI loop.
The second loop is used because, due to its diffi­cult bridge tap structure and its length, it stresses the transceiver start-up algorithms more than any of the ANSI-defined loops. Thus, if a transceiver can start up on this loop, it should be able to meet any of the ANSI-defined loops which have bridge taps. Also, on a straight 26 AWG loop, the T7264 can successfully start up at lengths up to 21 kft. This fact, combined with reliable start-up on the 15 kft 2BT loop above, illustrates that the T7264 provides ample start-up sensitivity, loop range, and robustness on all ANSI loops.
Another parameter of interest is pulse height loss (PHL). PHL can be defined as the loss in dB of the peak of a 2B1Q pulse relative to a 0 length loop. For an 18 kft 26 AWG loop, the PHL is about 36 dB, which is 2 dB worse than on ANSI Loop #1. A signal-to-noise ratio (SNR) measure­ment can be performed on the received signal after all the signal processing is complete (i.e., at the input to the slicer in the decision feedback equalizer). This is a measure of the ratio of the recovered 2B1Q pulse height vs. the noise remaining on the signal. The SNR must be greater than 22 dB in order to operate with a bit
error rate of <1e–7. start up on every loop. Also, due to the complex nature of 2B1Q transceiver start-up algorithms,
4444 Lucent Technologies Inc.
Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver
Appendix A. Questions and Answers
(continued)
A23: (continued)
With no impairments, the T7264 SNR is typically 32 dB on the 18 kft 26 AWG loop. When all ANSI­specified impairments are added, the SNR is about 22.7 dB, still leaving adequate margin to guarantee error-free operation over all ANSI loops.
Finally, to estimate range over straight 24 AWG cable, the 18 kft loop loss can be used as a limit (since the T7264 can operate successfully with that amount of loss), and the following calcula­tions can be made:
Loss of 18 kft 26 AWG loop @ 20 kHz 38.7 dB Loss per kft of 24 AWG cable @ 20 kHz 1.6 dB
38.7 dB
---------------------------
1.6 dB/kft
Therefore, the operating range over 24 AWG cable is expected to be about 24 kft.
Q24: What cable simulator is used for evaluating the
T7264?
A24: The original version of the transceiver was tested
using real cable for ANSI loop performance mea­surements. However, currently, the Lucent Tech­nologies Microelectronics Group laboratory uses the TAS2200A* Cable Emulator for evaluation purposes.
Q25: The data sheet states that the T7264 meets the
ANSI T1.601-1992 standard. Is there detailed evaluation data available on loops 1 and 4?
A25: The results shown in the following table for some
typical devices have been obtained in laboratory testing. Loops 1 and 4 are the most difficult cases.
ANSI
Loop #
Q26: What does the energy spectrum of a 2B1Q signal
look like?
= 24 kft
1992 ANSI
Configuration
1 LT 1.9 4 LT 7.6
XTALK Margin
(dB)
Q27: Does the return loss measurement described in
ANSI T1.601, Section 7, require that the T7264 terminate a metallic cable with 135 during powerdown?
A27: No. ANSI and ETSI specifications do not require
this. They require that the device be placed in an active mode with the transmitter producing 0 V (same as quiet mode) while performing the return loss measurements. The T7264 is placed in this mode by pulling the RESET pin low.
Q28: How is the T7264 set to quiet mode? A28: The device is placed in the quiet mode by pulling
RESET pin low . In this mode , the transmitter is
the on, but is producing 0 V.
Q29: Please clarify the meaning of ANSI Standard
T1.601, Section 7.4.2, Jitter Requirement #3.
A29: The intent of this requirement is to ensure that
after a deactivation and subsequent activation attempt (warm start), the phase of the receive and transmit signals at the NT will be within the specified limits relative to what they were prior to deactivation. This is needed so that the LT, upon a warm-start attempt, can make an accurate assumption about the phase of the incoming NT signal with respect to its transmit signal. Note that the T7264 meets this requirement by design because the NT phase offset from transmit to receive is always fixed.
Q30: How can proprietary messages be passed across
the U-interface?
A30: The embedded operations channel (eoc)
provides one way of doing this. ANSI defines 64 8-bit messages which can be used for non­standard applications. They range in value from binary 00010000 to 01000000.
There is also a provision for sending bulk data
over the eoc. Setting the data/message indicator bit to 0 indicates the current 8-bit eoc word con­tains data that is to be passed transparently with­out being acted on. Note that there is no response time requirement placed on the NT in this case (i.e., the NT does not have to echo the message back to the LT). Also note that as of 1993 this is only an ANSI provision and is not an ANSI requirement. The T7264 does support this provision.
A26: Figure A1 (curve P1) in the ANSI T1.601
standard gives a good idea of what this spectrum looks like.
Lucent Technologies Inc. 45
* TAS2200A is a trademark of Telecom Analysis Systems Incorpo-
rated.
T7264 U-Interface 2B1Q Transceiver
Data Sheet
April 1998
Appendix A. Questions and Answers
(continued)

K2 Interface

Q31: How are powerdown and w arm start performed in
the T7264?
A31: The powerdown/warmstart sequence is as fol-
lows:
At the LT, the series of events begins with the
assertion of ldea = 1. This causes the device to begin the automatic deactivation sequence. As long as the device control bits (istp, lpbk, and afrst) and the RESET and ILOSS pins remain inactive during this time, the LT device con­cludes deactivation by entering the powerdown state. From this condition, the loop can be reactivated by using a warm start.
At the NT, the device receives at least three
consecutive ldea = 0 bits from the LT during deactivation. These bits must be read from the K2 interface and interpreted to indicate that a deactivation is occurring. Once this condition is detected, the external controller must set ldea = 1 at the NT, causing the device to freeze its signal processor coefficients and power down when a loss of signal from the LT is detected. During this time, the device control bits (istp, Ipbk, afrst, etc.) and the RESET and
ILOSS pins must remain inactive at the NT.
From this condition, the loop can be reactivated with a warm start.
Q32: Does the device automatically reset and attempt
a cold start if out of frame (oof) occurs after a warm start?
A32: When an oof condition occurs, the device enters
a reframing algorithm and attempts to regain syn­chronization. During this time, the device is still active. If, after 480 ms, the device has not regained synchronization, it goes into the deac­tive state, from which the next start-up attempt will result in a cold start. This conforms to the state tables shown in Appendix C of ANSI T1.601.
Q33: What is the purpose of the sksi bit in the device
control (DC) octet?
A33: Its primary use is to detect a “stuck at one” condi-
tion on the K2 interface. It is reflected back onto the K2 interface as rsksi in the DS octet. Setting
sksi to 0 will guarantee that at least one bit (rsksi)
will be zero on the received K2 interface.
Q34: What should the state of the other bits in the DC
octet be during a local U-loopback?
A34: T o perform a loopback, the following sequence of
bits are set in the DC octet, where 1 resets the
device and puts it into a known state, 2 asserts
the loopback, and 3 resets the chip again and
removes the loopback. The other DC bits should
be kept in their inactive state:
1. afrst = 1, Ipbk = x, istp = 1, xpcy = x [loopbac k = inactive]
2. afrst = 0, Ipbk = 0, istp = 1, xpcy = x [loopbac k = active]
3. afrst = 1, Ipbk = 1, istp = 1, xpcy = x [loopbac k = inactive]
Q35: What is the state of the DO bits when OSYNC
goes low momentarily after the link is up?
A35: The 2B+D data and U-overhead bits are passed
transparently from the U-interface to the K2 interface. Since this U-information is likely to be invalid during this time, the system should recog­nize this and disregard the data and overhead bits during this time. Note that this situation is dif­ferent than when OSYNC is low prior to a start­up. In the latter case, the 2B+D and o verhead bits are internally overwritten by the transceiver to default values until synchronization is achieved (see the data sheet for these values). In either case, the DS bits are always valid.
Q36: ANSI requires 0.75 ms to process the eoc mes-
sage at the NT before echoing it. The T7264 data sheet, however, states that the time from when an incoming message becomes available and the next message goes out is 1.75 ms. How can the T7264 meet the standard?
A36: The 0.75 ms in the ANSI requirement refers to
the delay between the start of the received U frame and the start of the transmitted U frame. In the eoc bit locations, there are SW/ISW plus 12 2B+D blocks of data between the last bit of one eoc message and the first bit of the next one. This provides an additional 1.46 ms of processing time or a total of 2.21 ms. Of course, some of this time is consumed by the T7264 in moving data between the U and K2 interfaces. After these delays are taken into consideration, 1.75 ms remain to process data.
4646 Lucent Technologies Inc.
Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver
Appendix A. Questions and Answers
(continued)
Q37: What are the requirements on the transmission
and reception of eoc data on the K2 interface?
A37: This is described on page 24, Figure 18, of this
data sheet. To summarize, the received eoc data changes at K2 frames 47 and 95 (where frame 0 is marked by the rising edge of RSF). The most recent eoc data is continuously available on the K2 bus in the intervals between frames 47 and
95. The eoc data to be transmitted must be present on the K2 interface at outgoing K2 frames 11 and 59 (where frame 0 is marked by the rising edge of TSF). Since it is sampled only at those times, it does not matter what is present in those bit positions in the intervals between frames K11 and K59.
For an LT, normally it will not matter in which K2 frames the eoc data is written and read, as long the read/writes are done at 6 ms intervals (i.e., every 48 K2 frames). This is because there is no critical timing involved between the reception of an eoc message and its response, as there is at an NT.
For an NT, ANSI T1.601, Section 8.3.2, specifies that the eoc response must occur in the next available outgoing eoc fr ame. This means that the system has 13 K2 frames between the reception of a new eoc message at frame K95 (relative to RSF) and the transmission of the response to that message. Thus, the eoc timing at the NT should be referenced to RSF. Because of well­defined timing between RSF and TSF at the NT, there is no reason to use TSF for eoc timing.
Q38: The data sheet states that adea = 0 and Idea = 1
should not be used at the same time; why not?
A38: This mode is not recommended because it could
result in a system-level problem. Consider a typi­cal deactivation sequence for a network having a remote NT1 (i.e., an LT-to-NT connection with at least one intermediate element, as shown in ANSI T1.601, Figure E1) shows the events at the NT and LT when the LT initiates a deactivation. The LT uses adea in the
. The following table
case of an intermediate element to propagate the deactivation bit downstream without shutting itself down (as it would do if ldea were set instead):
LT
State
Normal
Operation
Downstream
Deactivate
After an appropriate amount of time to allow the message to propagate and the NT to react.
LT Deactivates ldea = 1
* This stores the coefficients and prepares the transceiver for
deactivation. Deactivation will occur on loss of signal from the intermediate element.
† Stores the coefficients and deactivates the LT transmitter
(stops transmitting).
LT K2
Data In
adea = 1
ldea = 0
adea = 0
ldea = 0
adea = 1
NT K2
Data Out
dea = 1
dea = 0 Set Idea = 1
x Detects loss
NT Action
upon third consecutive dea = 0*
of signal and deactivates
Notice that adea = 0 and ldea = 1 are permitted at the last step. This is because the NT has already stored its coefficients; however, if Idea = 1 were set earlier (for example, in step 2), the LT might deactivate before the downstream elements had stored their coefficients, and a clean deactivation would not occur. Therefore, to help avoid turning off the LT before all the down­stream elements store their coefficients, this state was defined as invalid.
Also, note that Idea = 1 will cause a chip set in the LT mode to store coefficients and deactivate, but it only causes a chip set in the NT mode to store coefficients. Deactivation at the NT only occurs upon loss of the U-interface signal.
Note: The preceding deactivation procedure is
only an illustration. In a nonrepeater envi­ronment, step 2 could be adea = ldea = 1, which would cause the LT to automatically save its coefficients and, within three or four K2 frames, deactivate. This case assumes that the NT has properly detected dea = 0 and then stored its coeffi­cients within those three or four frames.
Lucent Technologies Inc. 47
T7264 U-Interface 2B1Q Transceiver
Data Sheet
April 1998
Appendix A. Questions and Answers
(continued)
Q39: What is the relationship between istp and ldea? A39: The istp bit should be set to 1 before or at the
same time as ldea is set to 1. Once the chip set is deactivated, setting istp to 0 for at least three K2 frames will initiate start-up. However, it is neces­sary for ldea to be 0 before time T7 (see ANSI Table 5, Figure 16) for the start-up process to be successfully completed.
Q40: When should nebes and febes be counted? A40: During activation, nebes and febes will occur at
each end of the link between the time framing is initially achieved and the time the link is fully operational at each end. These nebe/febe occurrences are normal and are of no interest. Therefore, nebe/f ebe counters should be reset to zero after the link is fully operational. This is most easily achieved by delaying about 500 ms after getting oof = 1 and then resetting the nebe/febe counters.
Q41: How is the D+ channel for 3-DS0 TDM applica-
tions generated (Bellcore TR-TSY-000397)?
A41: Since the crc bits are not passed to the K2 inter-
face, the D+ channel cannot be formed directly; those bits must be generated externally. Also, a recent standard ballot addressed this issue by noting that, in general, the form of the D+ channel is application-dependent, so a broad standard is not being developed.
Q42: How does RSF behave during a reframe?
Q43: Does the K2 F clock do anything strange when a
RESET is asserted? This clock is being used to
initialize an elastic store, and it seems to be pro­ducing some strange glitches.
A43: There are two ways to reset the chip:
1. Assert the RESET pin low.
2. Assert the K2 afrst bit (DC octet) high. The difference between these two resets is that
#1 resets the entire chip, including the on-chip PLL, while #2 resets everything except the PLL. Therefore, for both resets, the counter which con­trols the frequency gets loaded to its initial value, but the counter which controls the phase only gets reset when the RESET pin is asserted.
In the case described, this means that with either reset #1 or #2, the frequency counter controlling F will be reinitialized, which could cause a strange duty cycle on F for one clock period. But once this initialization occurs, the F clock immedi­ately starts behaving normally, even if the RESET control remains active (also, in the case of reset #1, the PLL starts to acquire). From a system standpoint, you can always count on F behaving predictably when RESET is released because reset #1 or #2 must be asserted for at least 3 K2 frames, and the F clock duty cycle will stabilize after one K2 frame. So any logic for an elastic store which uses F should initialize upon exit from the reset state. However, be sure to consider the effect the shift in F may ha ve on other parts of the system.
Q44: What is the phase relationship between MTC and
F at the LT?
A42: RSF behavior is transparent to the oof (out-of-
frame) condition. Whenever the chip thinks it has found an ISW, it forces RSF high. RSF stays high for 12 K2 frames, at which point it goes low until the occurrence of the next ISW.
4848 Lucent Technologies Inc.
A44: F is phase-locked to MTC by a second-order PLL
that has a –3 dB frequency of approximately
0.5 Hz and has about 0.4 dB of peaking.
Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver
Appendix A. Questions and Answers
(continued)

Miscellaneous

Q45: Does the T7264 have a second source? A45: It is manufactured at multiple Lucent ME loca-
tions, but no second source outside Lucent is currently available.
Q46: Are digital I/Os TTL or CMOS compatible? A46: Both. All I/Os are CMOS. They are specified at
TTL because the current requirement makes this more difficult to meet. At higher output voltages, the current will be less, perhaps 100 mA at 3.5 V.
Q47: What is the current sinking capability of OSYNC? A47: The OSYNC lead supports a standard TTL load
and will sink (or source) 1.6 mA.
Q48: What are the tolerances of the various discrete
components around the chip set?
A48: Discrete components and their tolerances are as
follows:
Line-Side Resistors 16.9 ± 7% dc Blocking Capacitor 1.0 µF ± 5% Device-Side Resistors 16.9 ± 1% Bypass Capacitors 0.1 µF ± 10% Bypass Capacitors 1.0 µF ± 10%
Q49: If a switching power regulator is used in the
system, is there a frequency to which it should be set?
A49: A switching frequency of 80 kHz or higher
multiples, synchronous to the 2B1Q band clock, would be optimal. An 80 kHz clock is available at pin 43 that is synchronous with the 2B1Q signals.
Q50: Please explain how to use the
and its purpose.
A50: The FFC pin can be used in applications where
the MTC clock is switched from one source to another and may hav e glitches during the switch. One example of this is in DLC applications when the system switches to a protection clock board, and a new MTC clock is used. Before the protec­tion switch, FFC should be brought low to freeze the internal states of the timing recovery circuitry. After the new clock has stabilized, FFC can be
FFC pin in detail
brought high again and the T7264 circuitry will lock to the new clock without dropping the U­interface. Without the face might be dropped while the new clock is being applied.
Q51: What is the meaning of free-running and phase-
locked in Table 3 of this data sheet?
A51: In Table 3, CKOUT is defined to be either
3-stated, 15.36 MHz free-running, 7.68 MHz free­running, or 10.24 MHz phase-locked. Free-run­ning means that the CKOUT clock is directly derived from the 15.36 MHz crystal oscillator clock that is not synchronous with the U-interface line rate. Phase-locked means that the
10.24 MHz CKOUT clock is synchronous with the U-interface line rate. This clock does not have 50% duty cycle, and will experience occasional duty-cycle adjustments (i.e., phase steps) to keep it synchronous with the U-interface. (See the note at the bottom of Table 3 in the data sheet.)
Q52: What are the filter characteristics of the PLL at
the NT?
A52: The –3 dB frequency is approximately 5 Hz;
peaking is about 1.2 dB.
Q53: Is it possible to get a T7264-based LT to operate
properly with a NT without supplying an MTC clock?
A53: Yes. Tying MTC to +5 V will yield a ±100 ppm
MTC, which a Lucent NT will be able to lock to in most cases. This configuration should be used f or laboratory purposes only. For all serious perfor­mance testing, a ±32 ppm (or better) MTC should be used.
Q54: If there are several NT-mode T7264s on a board,
can only one crystal be used to run them?
A54: Yes. The following is an explanation of how this is
accomplished (refer to Table 3 on page 6 of this data sheet). First, connect a crystal in the normal fashion to one T7264; the V CKSEL pins should be set per the first entry in Table 3 (+5/0/0). Now set the VDDO, MCLK, and CKSEL pins on all the other T7264s as per the last entry in Table 3 (0/15.36/1), and use the
15.36 MHz signal coming from CKOUT (pin 23) of the first T7264 to provide the 15.36 MHz input to MCLK (pin 24) on the others.
FFC function, the U-inter-
DDO, MCLK, and
Lucent Technologies Inc. 49
T7264 U-Interface 2B1Q Transceiver
Data Sheet
April 1998
Appendix A. Questions and Answers
(continued)
Q55: Will the T7264 run in NT mode with the K2 clock
slaved to an external backplane?
A55: The T7264 does not support this mode. F or those
applications where this is an issue, systems designers have generally provided some elastic store on the K2-to-backplane ASIC. The elastic store must be sized according to the amount of jitter which can be introduced into a system and the amount of jitter gain in the system APLLs.
For example, assume that the backplane clock is derived from a recovered T1 clock. The worst­case jitter for a T1 line is 0.259 UI at frequencies of 0.001 Hz—10 Hz. Considering that an LT­mode T7264 APLL has jitter peaking of 0.4 dB at
0.15 Hz, the 0.259 UI of jitter could be amplified to 0.271 UI. Since 0.271 UI of 80 kHz is 3.39 µs, this is how much elastic store is required.
Note that this is a simplified example: there may be other APLLs in the system (for example, the T1-to-backplane clock APLL), and their peaking must be factored in also. In addition, it is desirable to design in some margin.
Q56: Is there a recommended method for powering the
T7264? For example, is it desirable to separate the power supplies, etc.?
A56: The T7264 is not extremely sensitive to power
supply schemes. Following standard practices of decoupling power supplies close to the chip and, if power and ground planes are not used, keeping power traces away from high-frequency signals, etc., should yield acceptable results. Separating the T7264 analog power supplies from the digital power supplies near the chip can yield a small improvement, and the same holds true for using power and ground planes vs. discrete traces.
Note: If analog and digital power supplies are
separated, the XTAL power supply (VDDO) should be tied to the digital supplies (VDDD).
Q57: What is the effect of ramping down the power
supply voltage on the device? When will it provide a valid reset? This condition can occur when a line-powered NT1’s line cord is repeatedly plugged in and removed and plugged in again before the power supply has had enough time to fully ramp up.
A57: The device’s reset is more dependent on the
RESET pin than the power supply to the device.
As long as the proper input conditions on the
RESET pin (see Table 32) are met, the device will
have a valid reset. Note that this input is a Schmitt-trigger input.
Q58: Does the output jitter of the 9 kHz F clock on an
NT-mode T7264 meet the 5% peak-to-peak jitter requirement described in ITU-T I.430, Section
8.3, assuming the S/T transceiver is the T7252A?
A58: Yes, the 5% requirement applies to high-
frequency jitter (>50 Hz) at the NT. The T7264 produces approximately 100 ns of high-frequency jitter in the NT mode on F, and the T7252A can accept up to 160 ns of high-frequency jitter on its input clock and still meet the I.430 requirement.
Q59: What should be known before having a T7264-
based product conformance tested at Bellcore?
A59: A copy of the Bellcore Test Bed Interface Specifi-
cation should be obtained from Bellcore to get the latest requirements.
The Bellcore specification, when last reviewed b y Lucent, required that a unit under test provide access to the following signals or state indicators. (The T7264 pin name in upper case, or K2 bit name, lower case, which corresponds to the Bellcore-required signal, is enclosed in braces.)
Transceiver Status Signals:
Fully operational state indicator {oof or OSYNC} Full reset state indicator {xact} Loss-of-frame alignment (opt) {oof or OSYNC} RX crc check indicator (opt) {nebe}
Transceiver Control Signals:
Transceiver full reset {RESET} Transceiver activation {istp} LT transceiver deactivation {ldea} Transmit M1—M4 bit control {K2 access} Transmit 2B+D payload gating {received act} Continuous scrambled output {ILOSS at NT} test mode {Ipbk at LT}
Intertransceiver Signals (LT only):
Superframe timing {conditioned tsf}
2.56 MHz clock {CKOUT/4} Note: T7264 must be optioned for a 10.24 MHz
CKOUT.
2B+D Test Access
18-bit bursted clock and corresponding 2B+D
serial data stream must be accessible in both transmit and receive directions.
5050 Lucent Technologies Inc.
Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver
Appendix A. Questions and Answers
(continued)
Q60: In the idle mode, when afrst or RESET is active,
the current increases from 6 mA (powerdown mode) to 40 mA—50 mA (normal mode). Is this proper behavior for the T7264? Also, is this a cor­rect interpretation of the data sheet description of idle mode (page 10, third paragraph)?
A60: This behavior is proper for the T7264. The reason
more current is needed in the reset state (i.e.,
RESET pin or afrst bit active) is that much of the
analog circuitry (line driver, band gap voltage ref­erences, A/D, and D/A) is powered down during the idle state, but is active during the reset state. Notice that idle and reset are two different states: reset state overrides idle when the RESET afrst is active. The reset state is normally a tran­sient state which only lasts a short time, unless the reset function is being constantly asserted. This means that RESET should not be used indis­criminately as part of a general start-up proce­dure. The meaning of the third paragraph on page 10 in the data sheet is that at the end of a
RESET condition, the transceiver will change to
the idle state (only momentarily if a start-up request is being made via the istp bit or a far-end wakeup tone). In this way, the data sheet is con­sistent with these results.
Q61: Can you provide detailed information on the
active power consumption of the T7264?
A61: When discussing active power measurement
figures, it is important to note that the conditions under which power measurements are made are not always completely stated by 2B1Q integ rated circuit vendors. For example, loop length is not typically mentioned in regard to power dissipa­tion, yet power dissipation on a short loop is noticeably greater than on a long loop. There are two reasons for the increased power dissipation at shorter loop lengths:
1. The overall loop impedance is smaller, requir­ing a higher current to drive the loop.
2. The far-end transceiv er is closer, requiring the near-end transceiver to sink more far-end cur­rent in order to maintain virtual ground at its transmitter outputs.
pin or
The lab measurements in the following table pro­vide examples of how power dissipation varies with loop length for a specific T7264 with its
15.36 MHz CKOUT output enabled and driving 40 pF (see the next table below f or inf ormation on CKOUT). Note that power dissipation with a zero length loop (the worst-case loop) is about 35 mW higher than a loop of >3 kft length. Thus, loop length needs to be considered when determining worst-case power numbers.
Loop Configuration Power (mW)
18 kft/26 AWG 273
6 kft/26 AWG 273 3 kft/26 AWG 277 2 kft/26 AWG 280 1 kft/26 AWG 288
0.5 kft/26 AWG 296 0 kft 308
135 load, ILOSS or lpbk
active, no far-end transceiver*
* This is the configuration used in Method B discussed on the
next page.
Also, in the case of the T7264, the use of the out­put clock CKOUT (pin 23) must be considered since its influence on power dissipation is signifi­cant. Some applications may make use of this clock, while others may leave it 3-stated. The power dissipation of CKOUT is as follows:
CKOUT
Frequency
(MHz)
15.36 21.3 11.0
10.24 17.7 9.1
7.68 12.6 6.6
The methods used to evaluate typical and worst­case power consumption are based on Lucent’s commitment to provide its customers with accu­rate and reliable data. Measurements are per­formed as part of the factory test procedure using automated test equipment. Bench top tests are performed in actual ISDN systems to correlate the automated test data with a typical implemen­tation. A conservativ e margin is then added to the test results for publication in the data sheets.
Power Due to
CKOUT 40 pF
Load (mW)
281.5
Power Due to
CKOUT No Load (mW)
Lucent Technologies Inc. 51
T7264 U-Interface 2B1Q Transceiver
Data Sheet
April 1998
Appendix A. Questions and Answers
(continued)
A61: (continued)
The following tables provide power consumption
data in several formats to allow customers to compare transceiver solutions.
The three test condition categories reflected in
the tables have been designated Method A, which reflects T7264 data sheet measurements; Method B, which reflects data obtained with a method used by other vendors; and Method C, which details revised T7264 measurements.
Method A
Test Condition Value
Loop Configuration 0 kft*
Temperature 25 °C
Pow er Supply Voltage 5 V
CKOUT 15.36 MHz
Max. Power Consumption 350 mW
* This is the worst-case loop. † 3 mW should be added for 85 °C.
The test conditions reflected in Method B repre-
sent a configuration used by other silicon vendors which eliminates the far-end transceiver from the network. This configuration should not be used to determine a system's total power requirements, but it can be used for comparison purposes among silicon solutions.
Method B
Test Condition Value
Loop Configuration 135 load only*
Temperature 25 °C
Pow er Supply Voltage 5 V
CKOUT 3-stated
Max. Power Consumption 275 mW
* The transceiver under test must be in a local U-loopback
mode. † 3 mW should be added for 85 °C. ‡ Anticipated customer configuration.
The conditions and test results in Method C are
the product of recent investigations into the device's mature test data. They can be used to reliably determine system-level power consump­tion requirements.
Method C
Test Condition Value
Loop Configuration 0 kft*
Temperature 25 °C
Pow er Supply Voltage 5 V
CKOUT 3-stated
Max. Power Consumption 300 mW
* This is the worst-case loop. † 3 mW should be added for 85 °C. ‡ Anticipated customer configuration.
5252 Lucent Technologies Inc.
Data Sheet April 1998
T7264 U-Interface 2B1Q Transceiver
Appendix B. Differences Between the T-7264- - -ML, T-7264- - -ML2, and T-7264A- -ML Devices

Technology

The T-7264- - -ML device is a 0.9 µm CMOS technology device, while the T -7264- - -ML2 and the T-7264A- -ML are
0.6 µm CMOS technology devices.

Standard

In 1996, the European Telecommunications Standards Institute (ETSI) added a microinterruption immunity require­ment to ETR 080 (Sections 5.4.5 and 6.2.5).
Section 5.4.5 in ETSI ETR 080 states the following:
A microinterruption is a temporary line interruption due to external mechanical activity on the copper wires con-
stituting the transmission path.
The effect of a microinterruption on the transmission system can be a failure of the digital transmission link.
The objective of this requirement is that the presence of a microinterruption of specified maximum length shall
not deactivate the system, and the system shall activate if it has deactivated due to longer interruption.
Section 6.2.5 in ETSI ETR 080 states the following:
A system shall tolerate a microinterruption up to t = 5 ms, when simulated with a repetition interval of t = 5 ms.
Since this is a new requirement, implementers were allowed until the end of 1997 to adhere to this requirement. The T7264 device was upgraded to fully comply with this standard and the device was given an A suffix (T7264A).
A proposal was added to the Living List (which is intended to collect issues and observations for a possible future update of ETSI ETR 080) to change the value of the microinterruption requirement from 5 ms to 10 ms. The current T7264A device from Lucent Technologies Microelectronics Group meets and exceeds this new requirement.
The above change to the transceiver has been fully verified, and test reports are available upon request.
Lucent Technologies Inc. 53
For additional information, contact your Microelectronics Group Account Manager or the following:
INTERNET: http://www.lucent.com/micro E-MAIL: docmaster@micro.lucent.com N. AMERICA: Microelectronics Group, Lucent Technologies Inc., 555 Union Boulevard, Room 30L-15P-BA, Allentown, PA 18103
ASIA PACIFIC:Microelectronics Group, Lucent Technologies Singapore Pte. Ltd., 77 Science Park Drive, #03-18 Cintech III, Singapore 118256 CHINA: Microelectronics Group, Lucent Technologies (China) Co., Ltd., A-F2, 23/F, Zao Fong Universe Building, 1800 Zhong Shan Xi Road, JAPAN: Microelectronics Group, Lucent Technologies Japan Ltd., 7-18, Higashi-Gotanda 2-chome, Shinagawa-ku, Tokyo 141, Japan EUROPE: Data Requests: MICROELECTRONICS GROUP DATALINE: Tel. (44) 1189 324 299, FAX (44) 1189 328 148
Lucent Technologies Inc. reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Copyright © 1998 Lucent Technologies Inc. All Rights Reserved
April 1998 DS97-413ISDN (Replaces DS90-184SMOS, AY93-032TCOM, and TN93-003TCOM)
1-800-372-2447, FAX 610-712-4106 (In CANADA: 1-800-553-2448, FAX 610-712-4106) Tel. (65) 778 8833, FAX (65) 777 7495 Shanghai 200233 P. R. China Tel. (86) 21 6440 0468, ext. 316, FAX (86) 21 6440 0652 Tel. (81) 3 5421 1600, FAX (81) 3 5421 1700
Technical Inquiries:GERMANY: (49) 89 95086 0 (Munich), UNITED KINGDOM: (44) 1344 865 900 (Bracknell),
FRANCE: (33) 1 41 45 77 00 (Paris), SWEDEN: (46) 8 600 7070 (Stockholm), FINLAND: (358) 9 4354 2800 (Helsinki), ITALY: (39) 2 6601 1800 (Milan), SPAIN: (34) 1 807 1441 (Madrid)
Loading...