Luceco 822BELL User guide

Page 1
Nexus Moulded
100M
RANGE
80dB
6
SOUND
MODES
LED
INDICATOR
FITS
25MM
BOX
Door Chime
door chime, with push button and a 100m range
Accessories Technical Information
Double switched 13 Amp power socket with built in
Push Button
x2 Fixing Screws
x2 Rawl Plugs
Double Sided Sticky Pad
Push Button Battery (3V CR2032)
Push Button Power Socket
Push Button
LED Indicator
CR2032 Battery Included
Socket/Chime
x2 Fixing Screws
LED indicator
terminals for easy wire identification
• Push Button : IP44
• Melody Count : 6
• Sound Level : 80dB
• Range : 100M (open air)
• Wall Box Depth : 25mm
Fits 25mm
wall box
Easy to install, colour coded
Installation
1. First, identify a suitable area for the push button to be positioned. Ideally, this should be sheltered from rain or excess heat. It would be recommended that the button is fitted to the door frame itself, so you are able to screw directly into the woodwork, making the installation simple.
2. Place a small flathead screwdriver into the slotted hole and gently twist to remove push button back.
3. Offer the push button backing up to the wall and drill holes. If fitting to masonry, use a 6mm drill bit, as per the depressions and securing by using the supplied rawl plugs and screws. If fitting directly to the woodwork, use a 2mm drill bit and screw directly into frame or use the provided sticky pad.
4. Pull plastic tab from under battery to power the push button.
5. Refit the push button to the secured backing by offering up the button of the push button and gently pushing back together.
press down
fit first
Page 2
Safety Warning
For your safety, this product must be installed in accordance with local Building Regulations.If in any doubt, or where required by the law, consult a competent person who is registered with an electrical self-certification scheme. Further information is available online or from your Local Authority. Please read carefully and use in accordance with these safety wiring instructions. Before commencing any electrical work ensure the supply is switched off at the mains. Either by switching off the consumer unit or by removing the appropriate fuse or turning off MCB (trip). Wiring should be in accordance with the latest edition of the IET regulations (BS 7671). To prevent fire hazard always use cable of the correct rating & type for the application.
Warning do not exceed the load rating of this device as stated on the rear of the product.
Wire Identification – Twin & Earth Cable
Note - As from 1st April 2004 new colour codes for hard wire installations were introduced.
EARTH = Green/Yellow Sleeving NEUTRAL = Black (pre Apr 04) / Blue (after Apr 04) LIVE = Red (pre Apr 04) / Brown (after Apr 04)
Wiring Instructions
1. Power Off
Before commencing work always isolate the power at the consumer unit / fuse box. *Note – If your installation uses a four-lug metal mounting box, remove the top and bottom lugs or bend fully back.
2a. Replacing an existing accessory
1. Unscrew the accessory from the wall/mounting box.
2. Note the cable connections: The illustration shows 1 wire of each colour connected to each terminal. There should be an additional connection between the mounting box earth terminal and the accessory earth terminal.
3. Unscrew each terminal to release the wire.
2b. New installation
1. Install mounting box (metal or moulded) for either flush or surface mounting, ensuring appropriate size of product.
2. Select the most suitable entry point of the mounting box (knock-out) and route the cables through. If a metal box is used, a cable grommet should be fitted to the entry point.
3. Cables should be prepared so a sufficient conductor length reaches the terminals. Strip the ends of the individual conductors leaving an adequate length bare to enter terminals.
3. Connection
LIVE
NEUTRAL
L
NEUTRAL
N
LIVE
EARTH
EARTH
E
TO MOUNTING BOX
EARTH TERMINAL
FUNCTIONAL EARTH
1. Line up the new accessory to mounting box and take note of where each terminal is located.
2. Connect each wire to the matching terminal. An earth connection should always be made between the mounting box earth terminal and the accessory earth terminal, where fitted. All bare earth wires must be sheathed with green/yellow sleeving. When connecting the new accessory ensure that only the bare end of the wire enters the terminal and no bare wires are visible.
3. Tighten terminal screws securely. (Do not over tighten)
4. This socket is fitted with two linked terminals to provide a dual earth facility. This is for use in “clean” installations where additional earth capacity is required to comply with Regulation 607 IEE Wiring Regulations.
4. Complete Installation & Test
1. Carefully position the accessory into the mounting box, ensuring that no wires are trapped between the plate and the wall and secure with screws (do not over tighten) then insert screw covers (optional).
2. Once the installation has been completed correctly, replace the fuse/reset MCB (trip), switch the power back on at the consumer unit and test.
Page 3
Unique Code Selection
The door chime and push button will be paired straight out of the box, with 1 out of 1 million unique codes to prevent interference with another door chime. If the door chime does not sound, please refer to the 'Pairing Additional Push Buttons & Door Chimes' section.
Setup Door Chime
Volume Selection
Chime Selection
Chime Selection
Single press the chime button on the left of the door chime socket to filter through the six different options – 4 x ‘Ding-dong’ and 2 x ‘Westmin­ster’ chimes.
Volume Selection
1. Single press the right side volume selection button to filter through the four different volumes settings. Options include – No sound, low, mid and high volume.
2. The LED flasher will always flash for 10 seconds on each press of the button.
Pairing Additional Push Buttons & Door Chimes
Press and hold the chime button until the LED illuminates, then release. Push the button on the ‘Push Button’, once the door chime socket will ring, then the units are paired. Repeat the process to pair additional push buttons to the door chime. (A maximum of 16 push buttons can be paired).
Reset Door Chime
Press and hold the chime button for 10 seconds or until you hear a triple ‘beep’ to reset the door chime.
Door Chime Not Working?
1. Ensure the battery in the push button is new.
2. Objects and materials, such as walls, doors, ceilings and furniture, are blocking the signal. Try moving the chime closer to the push button.
3. Wireless interference can be caused by external wireless devices, such as alarms and adaptors. It is recommend not to plug-in such devices in the door chime socket, or have in the close vicinity.
4. Door chime and push button are not paired – please refer to the ‘Pairing Additional Push Buttons’ section.
5. Ensure wired connections are made good, MCB is on and power is being made to the socket.
Maximum distance is based on an open area environment. Any walls, doors or ceilings may reduce the operating range. Door chime is to be used indoors only.
EU Directives
Radio Equipment Directive (RED)
2014/53/EU
2011/65/EU and its amendment
2015/863/EU
2009/125/EC ERP
(ROHS)
Article 3.1(a) Safety: EN62368-1:2014+A11:2017
Article 3.1 EN62479:2010
Article 3.1(b) EMC: Draft EN 301 489-1 V2.2.0 EN 301 489-3 V2.1.1 (2019-03)
Article 3.2 Radio: EN 300 220-1 V3.1.1 EN 300 220 2 V3.1.1 (2017-02)
ROHS 2011/65/EU and its amendment 2015/863/EU
ERP: EN 50564:2011
Conformas to
(a) Health
(2017-03)
(2017-02)
This product belongs to receiver category 2 : Caution Push Button This product contains a coin/button cell battery and if ingested can cause severe chemical burns. If the battery has been ingested, please seek medical advice immediately. In just 2 hours a digested battery can lead to death. Keep new and used batteries away from children. If the battery compartment does not close securely, please stop using the product.
Page 4
EU Declaration of Conformity
Applicant: Luceco PLC Address: Luceco Distribution Centre, Stafford Park 1, Telford Shropshire, United Kingdom (EU) Luceco SEC/Bobinadora 1-5 08302 Mataró SPAIN Description: 13A Socket with Door Chime Model: 822BELL We (Luceco PLC) declare under our sole responsibility that the products above are in conformity with the essential requirements of the following: Signed for and on behalf of: David Cleaver Senior Product Manager
Place of Issue: Stafford Park 1,Telford Shropshire, United Kingdom Date of Issue: 16/Mar/2020
Indoor use only Door Chime Socket only
Conformity with all relevant EC Directive requirements
IMPORTANT
This product does not consist of any serviceable parts and should not be repaired. The device should not be operated by persons who have a lack of experience or knowledge in using such products. People who have a reduced physical, sensory or mental capability should be supervised or given instruction when operating. Children should be supervised, so that they do not play with the device.
Environmental Protection
This symbol is known as the “Crossed-out Wheelie Bin Symbol”. When this symbol is marked on a product or battery, it means that it should not be disposed of with your general household waste. Some chemicals contained within electrical/electronic products or batteries can be harmful to health and the environment. Only dispose of electrical/electronic/battery items in separate collection schemes, which cater for the recovery and recycling of materials contained within. Your co-operation is vital to ensure the success of these schemes and for the protection of the environment.
Batch Code explanation
yyWxx Manufacturing date code, year of manufacture (yy) and week of manufacture (Wxx)
Luceco Help Line
Supplied by
Luceco PLC
Luceco PLC Stafford Park 1 Telford TF3 3BD ENGLAND
(EU) Luceco SEC/Bobinadora 1-5 08302 Mataró SPAIN
Visit our website at
www.bgelectrical.uk
Loading...