Airfusion Radar Installation Instructions
2 | Page
IMPORTANT INFORMATION – PLEASE READ PRIOR TO INSTALLATION
Congratulations on purchasing the latest in energ y saving ceiling fans. This Airf usion Radar fan runs on DC (dir ect
current) power which gives it the benefit of being super energy efficient whilst still maintaining high volume air-movement
and silent operation.
Energy saving - The DC m otor is the latest t echnology in fan design. Its high ly efficient m otor saves up to 65% more
energy than ceiling fans with traditional AC motors.
Silent operation – This DC fan motor is programmed with a stabilized current which efficiently reduces motor noise.
Low operating temperature – The DC power is managed effectively which brings down the motor operating
temperature to less than 50degs. This results in a much cooler motor than a standard AC fan and increases the longevity
of the motor.
Regular AC ceiling fans usuall y come with on ly 3 spe eds, this Airf usion Ra dar DC f an com es complete with a 6 speed
remote, which gives a greater choice of comfort levels.
SAFETY PRECAUTIONS
1) This ceiling fan is NOT intended f or use by persons (inc luding children) wit h reduced physical, s ensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
2) Children should be supervised to ensure that they do not play with the appliance.
3) An all-pole disconnection switch must be incorporated in the fixed wiring in accordance with the wiring rules.
4) Do not dispose of electrical appliances as unsorted municipal waste, use separate collection
facilities. Contact your local government for information regarding the collection systems
available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can
leak into the groundwater and get into the food chain, damaging your health and well-being.
5) The structure to which the fan is to be mounted must be capable of supporting a weight of 30kg.
6) The fan should be mounted so that the blades are at least 2.3 metres above the floor for Europe.
7) The fan should be mounted so that the blades are at least 2.1 metres above the floor for Australia.
8) This f an is suitable for indo or use only. Mounting t he fan in a situati on where it is subj ect to water or m oisture is
dangerous.
9) Only an authorized electrician should execute the installation.

Airfusion Radar Installation Instructions
3 | Page
PARTS LIST
Unpack your ceiling fan carefully. Remove all parts and hardware. Place the fan motor on a cloth or soft surface to avoid
damaging the finish.
• Do not lay the motor housing on its side – the decorative housing may become bent or damaged.
• Verify that all parts are present before starting assembly.
• Check the packaging carefully for missing parts.
Examine all parts. You should have the following:
1 Mounting bracket x 1
7 Remote transmitter with holder x 1 set
2 Fan assembly with hang ing plate, receiver, and
motor x 1
8 Extra Motor screws x 1 (not shown)
3 Motor housing x 1
9 Wooden screw x 4 (not shown)
4 Blade x 3
10 Screw for remote holder x 2 (not shown)
5 Blade bracket kit x 3
11 12V Battery for remote x 1 (not shown)
6 Bottom cover x 1
Fig. 1

Airfusion Radar Installation Instructions
4 | Page
INSTALLING THE FAN
TOOLS REQUIRED:
- Phillips / Flat head screwdriver
- Pair of pliers
- Adjustable spanner
- Step ladder
- Wire cutter
- Wiring, supply cable as required by local provincial and national wiring codes and regulations.
INSTALLING THE MOUNTING BRACKET
The ceiling fan m ust be installed in a location so that the blades are spaced 300mm from the tip of the blade to the
nearest objects or walls.
Secure the hanging br acket to the ceiling j oist or structur e that is capable of carrying a load of at least 30kg, with t wo
long screws provided. Ensure at least 30mm of the screw is threaded into the support.
NOTE: The bracket screws provided are for use with wooden structures only. For structures other than wood,
the appropriate screw type MUST be used.
ANGLED CEILING INSTALLATION
This fan hanging system DOES NOT support a degree angled ceiling installation.
Fig. 2

Airfusion Radar Installation Instructions
5 | Page
HANGING THE FAN MOTOR ASSEMBLY
• Lift the fan assembly to the mounting bracket (1) and let the J-hook of the mounting bracket (4) go through the hole
of the hanging plate and hang up the fan assembly (3). Fig. 3
• Connect the male and female connector together (2). Fig. 3
• Complete the electrical wiring using the diagram below (Figure. 4).
PREPARE AND COMPLETE THE ELECTRICAL WIRING --- WIRING DIAGRAM (Fig. 4)
WARNING: FOR YOUR SAFETY, ALL ELECTRICAL CONNECTIONS MUST BE UNDERTAKEN BY A LICENSED
ELECTRICIAN.
NOTE: AN ADDITIONAL ALL POLE DISCONNECTION SWITCH MUST BE INCLUDED IN THE FIXED WIRING.
NOTE: IF TH ERE ARE TWO OR MORE DC CEILING FANS INSTALLED IN THE ONE LOC ATION, AN ISOL ATION
SWITCH IS REQUIRED FOR EACH CEILING FAN. THIS IS REQUIRED WHEN PROGRAMMING THE REMOTE AND
RECEIVER TO PAIR TOGETHER.
Fig. 4

Airfusion Radar Installation Instructions
6 | Page
INSTALL THE CANOPY COVER
• Loosen 2 screws (2) from the mounting bracket. Fig. 5
• Loosen 2 screws (1) by half thread from the mounting bracket. Fig. 5
• Lift the hanging plate of the fan assembly up to the mounting bracket and let the L-shape slot on the hanging plate
go through the screws (1) on the mounting bracket. Turn the hanging plate until it locks in place at the end section
of the L-shape slot and secure it by tightening the two screws (2). Avoid damaging the electrical wiring prepared
previously.
• Finally attach the motor housing to the hanging plate and secure it by pushing the hooks (3) into the slot holes and
turn it anti clockwise.
BLADE INSTALLATION
• Insert the blade screws through the blade assembly in the following order - bracket kit (2) and blade (1).
Attach the blade assembly to the motor and secure it by tightening the 2 screws (3). Fig. 6
• Repeat to install the other blades.
• Finally install the bottom cover (4) to the shaft of the motor by rotating it clockwise.
Fig. 6
Fig. 5

Airfusion Radar Installation Instructions
7 | Page
LIGHT KIT Installation (L ight kit - optional)
NOTE: The light kit must be installed by a licensed
electrician.
NOTE: The light kit is available for selected ceiling fan
models and as an optional light kit.
1. Remove the bottom cover from the shaft.
2. Remove the shinkable tube from the light wires
connector.
3. For light kit installation, please refer to the light kit
installation user guide.
USING YOUR CEILING FAN
Pairing Transmitter and Receiver – when 2 or more DC ceiling fans are installed in one location
When two or more ceiling fans are located near each other, you may desire to have the receiver/transmitter for each fan
set to a different code so that the operation of one fan does not affect the operation of the other fan/s.
The DIP switches for the t ransmitter (remote hand piece) are locate d in the battery compartment of the tr ansmitter.
Configuring the DIP switches will allow a unique transmission code assigned to each ceiling fan.
NOTE: Ensure that you have installed an all - pole disconnection switch in the fixed wiring for each fan, when using DIP
code function.
NOTE: Ensure power to the Receiver is ON prior to pairing the transmitter with the receiver.
Transmitter/Receiver pairing for ceiling fan 1:
• Turn off both ceiling fans 1 and 2 via the mains supply to the receiver.
• Slide the cover of the battery compartment of the transmitter to access the DIP switches. This will be transmitter 1.
• Change the position of the DIP switches in the remote transmitter 1, so that it will be different to transmitter 2. Fig. 8
• Install the 12V DC battery in the compartment. Please make sure the polarity of the battery is correct.
• Turn on the power to receiver 1. Keep t he power OFF to receiver 2. (Eac h ceiling f an must have its own i solation
switch, so that only the ceiling fan that needs to be paired with the transmitter will be ON).
• Press and hold the SET button of transmitter 1 for 6 seconds within 60 seconds of switching the p ower to the
receiver of ceiling fan 1.
• Now the transmitter should be paired with the receiver of ceiling fan 1. Turn ON/OFF or change the speed of ceiling
fan 1 by the transmitter to check the operation.
Fig. 7

Airfusion Radar Installation Instructions
8 | Page
Setting DC Ceiling fan 2:
• Turn off both ceiling fans 1 and 2 via the mains supply to the receiver.
• Slide the cover of the battery compartment of the transmitter to access the DIP switches. This will be transmitter 2.
• Change the position of the DIP switches in the remote transmitter 2, so that it will be different to transmitter 1. Fig. 8
• Install the 12V DC battery in the compartment. Please make sure the polarity of the battery is correct.
• Turn on the power to receiver 2. Keep t he power OFF to receiver 1. (Eac h ceiling f an must have its own i solation
switch, so that only the ceiling fan that needs to be paired with the transmitter will be ON).
• Press and hold the SET button of transmitter 2 for 6 sec onds within 60 seconds of switching the power to the
receiver of ceiling fan 2.
• Now the transmitter should be paired with the rec eiver of c eiling fan 2. Turn ON/OFF or c hange the speed of the
ceiling fan 2 by the transmitter to check operation.
Note: The pairing of Transmitter and Receiver is not required if only one ceiling fan is installed. When more than
two ceiling fans are installed near each other, please refer to the instruction above.
Remote Control Buttons
○
1 - FAN SPEED CONTROL BUTTON:
There are 6 available speeds.
○
I button is for the lowest
speed, and
○
VI button is for the fastest speed.
NOTE: WHEN YOU TURN ON THE FAN FOR THE FIRST
TIME OR SWITCH THE MAIN POWER TO THE
CONTROLLER, YOU NEED TO START THE FAN ON HIGH
“
○
VI ” SPEED FIRST AND THEN CHOOSE A LOWER
SPEED. A 5 -10 SECONDS IS R EQUIRED TO ALLOW THE
DC FAN TO RESPOND TO THE REMOTE EACH SPEED
OR FAN DIRECTION SELECTIONS, AS DC FANS
INCORPORATE A SENSOR CONTROL WHICH CONTROLS
THE POWER TO THE MOTOR.
Fig. 9
Fig. 8

Airfusion Radar Installation Instructions
9 | Page
○
2 - FAN OFF BUTTON:
Press the button to turn the fan off.
○
3 - REVERSE FUNCTION BUTTON:
Press the button to activate the reverse running function. The fan must be operating to activate the reverse function.
○
4 - LIGHT CONTROL BUTTON:
Press the button to turn on/off the light.
THE RECEIVER PROVIDES THE FOLLOWING LEVEL OF PROTECTION:
• Lock position: the rece iver has a bu ilt in safety featur e to protect aga inst obstruction d uring operation . The motor
will be locked from operation and will disconnect from power after 30 seconds of interruption. Please remove
obstacles before re-starting. To reset, simply turn off the power supply to the fan motor and re-start.
• Over 80W protection: when the receiver detects power consumption which is greater than 80W, the receiver power
will be stopped and operation will immediately discontinue. Turn the receiver power on after 5 seconds to restart the
fan.
REPAIRING THE FAN RECEIVER & REMOTE PAIRING
Should the remote and receiver lose control after installation or during use, the pairing of the remote and the
receiver must be rep a ired. Bel ow are the oper ati ng sy mptoms and me thod to r epair the pairing of the DC ceiling
fan remote and receiver.
Issues:
• Loss of control - Fan is only running at high speed after installation
• Loss of control - No reverse function after installation
• Loss of control - Remote cannot communicate with receiver
Solution:
If the fan runs at the highest speed continuously, it means the wiring of the installation is correct. When the fan operates
on high s peed only or f ails to operate in reverse f unction or any other comm and/s, it is recommended to r epair the
communication pairing of the remote and receiver. Please follow the steps below:
A. Remove the battery cover of the remote, check the 434 MHz sticker area, make sure the battery is installed
correctly and the red LED light indicator will be flashing, it means the remote function is okay.

Airfusion Radar Installation Instructions
10 | Page
B. Turn of f the main supply to receiver more than 30 seconds and turn on the main supply to receiver again. Press and
hold the SET button of remote for 6 seconds within 60 seconds of turning turn the power to the receiver.
C. Press the buttons on the r emote to r un the fan. In general, p erforming po int A, B, and C shoul d repair the rem ote
and receiver, and will allow full control of the fan. If not, please do the next step.
D. The DIP switches of fans are set up at the factory in all up. And we can change DIP switch at any location in 16
options. (Ex. up-up-down-down).
E. Please repeat the (A)-(C) steps to check the function.
If the issues still persist after follo wing point (A) t o (D) and t here is stil l no control , then pleas e contact the lo cal retailer
for a new remote or transmitter.

Airfusion Radar Installation Instructions
11 | Page
NOTE: For your safety, a new receiver must be installed by a licensed electrician.
NOTE: While repairing the DC ceiling fan remote and receiver i s in process, t he fan operates at high est speed
with REVERSE mo de automatically fo r 90 seconds and then operates with FORWARD mode for 90 seconds.
During the paring process, do not press any key on the remote.
CARE & CLEANING
• Periodic cleaning of your ceiling fan is the only maintenance r equired. Use a soft br ush or lint free cloth to avoid
scratching the paint/plated finish. Please make sure the fan is not operating when cleaning.
• Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility
of an electrical shock.
WARRANTY S ERVICE
The manufacturer warrant y covers actual faults that may develop, but NOT minor complaints, e.g. noise from motor
run—ALL ELECTRIC MOTORS ARE AUDIBLE TO SOME EXTENT.
AUSTRALIAN/NEW ZEALAND CUSTOMERS – Please refer to the separate WARRANTY STATEMENT.
EUROPEAN CUSTOMER – Please contact the retail outlet where the fan was purchased for a warranty service.
WOBBLE
• Ceiling fans ten d t o move during operation due to the fact that they are not generally rigidly mounted. If they were,
they could generate excessive ceiling vibration and stress on their mountings.
• Movement of a couple of centimetres is quite acceptable and does not suggest that the fan will fall down.
• Ceiling fans are m ounted very securely on steel bra ckets with rubber cushioning or w ith ball-joints to allow free
movement.
• Please note that not all ceiling fans are the sam e, even in the sam e model—som e may move mor e or less than
others.
NORMAL WEAR AND TEAR
Threaded components work ing slightl y loose or blade carrier s even slig htl y bent due to v igorous cleani ng or bum ping
can cause extra wobble and n oise. TH IS IS NOT COV ERED UN DER WARRANTY, but a little care and maintenance
can reduce or prevent this problem.
BUMP IN THE NIGHT
This is the biggest cause f o r s er vice c alls , which are o utside t he manufacturer’s warranty. If a fan has a fault, it will be
noticeable at all tim es. Naturally, when everything is quiet at night, you will be m ore inclined to hear sm all noises,
which may not be noticeable at other times. Even slight power fluctuations and mains frequency signals superimposed
in your electricity supply for off-peak hot water control may cause a change in fan motor noise. This is normal.
FAN LIGHT
Except for actual faults in the manufacture, which are extremely rare, FAN LIGHTS AND GLOBES ARE NOT
COVERED UNDER YOUR FAN WARRANTY. Noises and vibration etc. are often more accentuated when a fan light is
fitted. F or instance a f an light glass that has not been tightened or has worked lo ose can cause a rattle. Ag ain, care
and maintenance will reduce this. Glass of all kinds is warranty to the retailers’ door and subject to the retailer
checking it on delivery.

Airfusion Radar Installation Instructions
12 | Page
TROUBLE SHOOTING CHECKLIST
Always check the “Trouble Shooting Checklist” included in this booklet before calling for service. Unnecessary calls are
inconvenient for all and can attract a service charge.
WARNING: THE CEILING FAN MUST BE SWITCHED OFF BEFORE TROUBLE SHOOTING IS PERFORMED.
NOTES TO INSTALLER
• All electric motors, including fans make some noise and may feel hot if touched—this is not a fault.
• Some fans wobble more than others—even in the same model.
• Fan lights can rattle, but are not covered under warranty.
• Fan wall controllers make a slight buzz and get warm especially on lower settings.
These occurrences are not covered by the manufacturer’s warranty.
TROUBLE PROBABLE CAUSES SUGGESTED REMEDY
ceiling
fan must be switched
and the assistance
of a licensed electr ician
A. Fuse or circuit breaker blown.
Check main and branch circuit fuses or
circuit breakers.
B. Loose power connections to
ormally occur during
installation.)
Check power connections to fan. Must be
performed be a licensed electrician.
C. No response from the remote
- Battery is low. Replace batteries.
Check if correct remote transmitter is paired
with the receiver.
D. Switch the Fan ON via the
mains switch.
Check if there is power to the fan.
2. Fan Wobbles
(Refer
to Wobble
section of the manual
for further information).
A. Fan blades are not horizontal
Refer to “wobbling fixing” section of manual.
The blade may require adjustment at the
blade mounting screws;
- The blade is out of shape, thus
causing
wobbling. New blades set will require to
be replaced. Contact retailer for further
details.
B. Blade screws are loose.
Make sure all screws are securely fastened.
C. Blade/s are out of shape.
Remove blade and la y on a fl at su rfac e to check
shape. Contact retailer for
further details.
A. Top canopy touching ceiling.
Lower canopy from ceiling to ensure minimum 3
mm clearance.
B. Loose fan blade screws.
Re-tighten all screws on fan blades but never
over-tighten.
C. Ceiling fan not secured
against ceiling.
tighten all screws in the hanging bracket or
plate.
D. Incorrect speed controller. Change the controller to the one supplied.
(Must be performed by a licensed electrician.)
4. Mechanical Noise.
A. Allow at least for 8 hours
settling-in period.
5. Light will not turn
ON (Optional light kit
ONLY).
The globe/lamp has failed. Replace globe/lamp.

Airfusion Radar Installation Instructions
13 | Page
TECHNICAL INFORMATION
WARRANTY CONDITIONS
IN AUSTRALIA / NEW ZEALAND – Please refer to the separated WARRANTY STATEMENT.
IN EUROPE – If you are a E uropean customer please contact the retail outlet where the fan was purch ased for a
warranty service.
This product is guaranteed against electrical defec ts in material or manufactur ing workmanship for faults when under
normal domestic/residential conditions for a certain period of time from the date of purchase. This warranty covers parts
and labour costs for the motor subject to the following conditions:
1. Installation being perform ed by a qualified licensed electrician.
This warranty will not apply if the ceiling fan is installed by anyone other than a licensed electrician. Problems arising
from incorrect installation are not cov ered by warran ty. The cost of repairs and/or service c alls w here the def ect is
due to the installation and not due to faulty material or workmanship, in accordance with wholesaler and their
authorized agent, will be payable at time of repair.
2. The correct controller being fitted to the fan.
Only use the controller supplied with the fan or a genuine replacement. Using solid-state dimmer type or non-genuine
controllers will void the warranty. Use of non-genuine controllers may cause the fan to operate with a loud hum and at
altered speeds. Where controllers are supplied complete with light switch – do not use this switch to operate the fan.
Fans connected using this switch to turn the fan on/off, will not be covered by warranty.
3. Repair work being carried o ut by a licensed electric ia n only after authorization b y t he wholesaler or their authorized
agent to complete the repair and is subject to the supply of dated proof of purchase and installing electricians
details.
4. The exclusion from warranty of any chang es to ceiling fan bla des or motor, plated and/or painted f inishes due to
climatic conditions (moisture, salt air etc.) or after 6 months from the date of purchase or other circumstances
deemed to be beyond the control of wholesaler or their authorized agents.
5. The warranty service does not cover:
a. Transportation and in-transit insurance costs, if the product or parts thereof have to be returned for repair or
replacement to the retailer or their authorized agent.
b. Repair of defects caused by accident, fire, misuse, alterations modification, negligence, incorrect or
incomplete installation/op eration, any unauthorized person attem pting to repair the ceiling fan, or acts of
God.
c. Claims or damage to furniture, carpet, wall, ceiling foundations or any other consequential loss either direct
or indirectly resulting from a faulty ceiling fan.
6. Except in the case of pre-packed integrated light m odels, light fittings attached to the f an are not covered by this
AIRFUSION
RADAR SERIES
Rated Voltage
Rated power
(motor)
Battery for remote

Airfusion Radar Installation Instructions
14 | Page
warranty. Where the fan is pre-pack ed c omplete with a light, t he l ight f itt ing will be c ov ered by warranty to el e c tric al
defect. Tarnishing caused by climatic conditions and br eak age of glasses is not cover ed by warranty. Globes/lamps
are also not covered by warranty. All light fitt ings attached to the fan mus t be installed by a licensed elec trician
ensuring such attachments are complete and do not affect the fan’s performance. Light fittings will often accentuate
noises and vibrations, whic h can be trace d to l oose glass or fittings and are not covere d b y warr ant y. Broken glass
as supplied in the pre-packed light complete m odels is not considered a n item requiring a warrant y service call.
Notification within 48 hours of installation is required where glasses have found to be broken on unpacking.
7. The warranty applies to actual faults which may develop. Minor running noises are not covered. All electrical motors
have some audible nois e. Allow at least eight hours of operation to allow the bearin gs to properly seat. The fan,
especially when set on low, may feel warm to touch – this is not a fault. If excessive heat is generated a service call
may be required. Fan noises can vary due t o slight power fluctuations and mains f requency signals for off-peak
controlled appliances. These changes are most noticeable in the quiet of night, mains frequency signals which come
across as an intermittent hum (mostly at night) are out of control of the manufacturer. In these cases your electricity
provider should be contacted, or an electrician to fit a suitable noise filter.
8. Threaded components such as blade nuts can work slightly loose during normal operation. These should be
tightened regularl y to ensure the f an doesn’t develop operation noises. If noises do develop, check this a spect
before requesting service. This is not covered by warranty.
9. Minor variation of speed m ay be e vident bet ween different f ans, even in the sam e m odel and is not a pr oduct f ault
and not covered by warranty.
10. Blades are not covered by warranty agains t def ec t in material. The rep lacement of the blades is n ot c o vere d by the
in home warrant y service call , notificat ion withi n 48 hours of installation is require d where b lades hav e found to be
broken on unpacking, contact the retailer or the ir authorized agent who will send you a new set of blades. Each
blade set is balanced so it is important to replace all blades. Blades affected by climatic conditions and by
maintenance are not covered by this warranty .
This warranty applies only to Austr alian states; its m ainland territor ies and New Z ealand. The be nefits of this warranty
are in addition to any benefits offered under state or territory law.
For under warranty ser vice, contact the hotline number in this b ooklet and advise: the model num ber and style, the
nature of the fault, date and place of purchase. Service cannot be arranged without this information.
Prior to requesting service, please consult the trouble-shooting checklist that is printed in this manual.
• All electric motors, including fans, make some noise and may feel hot to touch – this is not a fault.
• Some fans wobble more than others – even in the same model.
• Blades are weighed to be within tolerance to minimize wobbling. In multiple installations, do not mix blades from
fans.
• Fanlights can rattle and are not covered by warranty.
• Finish to the fan, including blades and light complete models, are covered by 2 years warranty.
• Blade and glass replacements are not covered by in home servicing.