LTA C2N-CBD-P TEST REPORT

Page 1
Certification No. : LR500171707E
Test Report No.
:
Issue Date
:
Applicant Name
:
Product Name
:
Model Name
:
Brand
: - Serial Number
:
This laboratory is accredited by Voluntary Control Council for Interference
TEST REPORT
The tests reported herein have been performed in accordance with its terms of
and National Voluntary Laboratory Accreditation Program.
accreditation.
Applied Standard :
VCCI RULES AND REGULATIONS OF CLASS A
This test result onl y responds to the t ested sample. It is not allowed to copy this
report even partly without the allowance of the test laboratory. The report must
not be used by the client to claim product certification, approval, or
endorsement by NVLAP, NIST, or any agency of the Federal Government.
Copyright © 2017, LTA CO., LTD. Page 1 of 29
Page 2
Certification No. : LR500171707E
Text
Page
TABLE OF CONTENTS
★★★★★★★★★★★★
Contents ---------------------------------------------------------------------------------------------------------- 2
LTA Certification ----------------------------------------------------------------------------------------------- 3
General Information ----------------------------------------------------------------------------------------------- 5
Brief Information --------------------------------------------------------------------------------------------------- 6
Test site description -------------------------------------------------------------------------------------------------- 9
Test Procedure ------------------------------------------------------------------------------------------------------ 11
List of test equipment used for the test ----------------------------------------------------------------------- 14
Radiated disturbance measurement --------------------------------------------------------------------------- 15 Result & Graph
Conducted disturbance measurement ------------------------------------------------------------------------- 17 Result & Graph
Conclusions --------------------------------------------------------------------------------------------------------- 21
Photograph of the measurements ------------------------------------------------------------------------------- 22
Photograph of the EUT ------------------------------------------------------------------------------------------ 24
★★★★★★★★★★★★
Copyright © 2017, LTA CO., LTD. Page 2 of 29
Page 3
Certification No. : LR500171707E
Client / Manufacturer
Equipment Under Test (EUT)
C2N-CBD-P-A-S, C2N-CBD-P-AT,C2N-CBD-P-B-S, C2N-CBD-P-B-T,
C2N-CBD-P-W-S, C2N-CBD-P-W-T
Model Description
Test Performed
LTA Certification
Comp any name : Crestron Electronics. Inc. Address : 15 Volvo Drive, Rockleigh, NJ 07647, United S t ates Telephone / Facsimile :
+00-800-237-2041 Ext:123 45
Factory
Comp any name : Address :
Trade name : ­Product name : Model name : C2N-CBD-P
Variant model name :
Serial number : ­Intended environment : Residential area Date of receipt : June 21, 2017 EUT condition : Pre-production, not damaged Interface Ports : NET
Crestron Electronics. Inc. 15 Volvo Drive, Rockleigh, NJ 07647, United S t ates
Cameo® Keypad, Standard Mount
C2N-CBD-PBRN-S, C2N-CBD-P-DA-S, C2N-CBD-P-DSKT, C2N-CBD-P-GRY-S, C2N-CBD-P-IVR-S, C2NCBD-P-LAT-T,
Power Source : DC 24 V Crystal/Oscillator(s) : ­Firmware version : XXXX
- None
Test started & completed : July 11-Jul y 13, 2017 Location : LTA Co., Ltd.
*** To be continued next page ***
Copyright © 2017, LTA CO., LTD. Page 3 of 29
Page 4
Certification No. : LR500171707E
Test Specification
Test Results
Purpose of the test : Compliance test to the following standard
Applied standard :
Measurement Results* Test method Radiated disturbance Complies V-3/2015.04 Radiated disturbance at above 1 GHz Not Applicable V-3/2015.04 Conducted disturbance Complies V-3/2015.04 Conducted disturbances at telecommunication ports * : The compliance statement is ba s ed on nominal value only.
Laboratory’s Certificate
Report number : LR500171707E Issue date : July 14, 2017
This test report is issued under the authority of: The test was super vi s ed by:
VCCI RULES AND REGULATIONS OF CLASS A (V-3 / 2015.04 Normative ANNEX 1:Technical Requirements)
Not Applicable V-3/2015.04
Yong-Cheol, Wang, Manager Min gi Kang, Te s t Engineer
Copyright © 2017, LTA CO., LTD. Page 4 of 29
Page 5
Certification No. : LR500171707E
Purpose
Test Performed
Measurement uncertainty
Accredited agencies
General information’s
This document is based on the Electromagnetic Interference (EMI) tests performed on the C2N-CBD-P”. The measurements were performed according to t he measurement procedure described in VCCI RULES AND REGULATIONS OF CLASS A V-3 / 2015.04 Normative ANNEX 1:Technical Requirements)
Comp any name : LTA Co., Ltd. Address : 243, Jubug-ri,Yangji-Myeon, Cheoin-gu,Youngin-Si, Kyunggi-Do, Korea. 449-822 Telephone / Facsimile : +82-31-323-6008 / +82-31-323-6010
Radiated disturbance (30 – 1 000 MHz) : +4.52 [dB] ,-4.43 [dB] (k=2) Radiated disturbance at above 1 GHz (1 GHz – 6 GHz) +3.0 [dB] ,-3.0 [dB] (k=2) Conducted disturbance (0.15 – 30 MHz) : +0.11 [dB] ,-0.11 [dB] (k=2) Conducted disturbances at telecommunication ports
The coverage factor k=2 yields approx. a 95% level of confidence for near-normal distribution typical of most measurement results.
(0.15 – 30 MHz) : +0.11 [dB] ,-0.11 [dB] (k=2)
LTA Co., Ltd. Is approved to perform EMC testing by the following agencies:
Agency Country Accreditation No. Validity Reference
NVLAP U.S.A 200723-0 2017-09-30 ECT accredited Lab. RRA KOREA KR0049 - EMC accredited Lab. FCC U.S.A 649054 2019-04-13 FCC CAB
R-2133(10 m),
VCCI JAPAN
2017-06-21 VCCI registration
C-2307
VCCI JAPAN T-2009 2017-12-23 VCCI registration VCCI JAPAN G-847 2018-12-13 VCCI registration IC CANADA 5799A-1 2019-11-07 IC filing
Copyright © 2017, LTA CO., LTD. Page 5 of 29
Page 6
Certification No. : LR500171707E
1-1 Test Summary
1-2 Operating Mode of the EUT
1-3 Modification
Brief Information
Parameter Applied Standard
I. Emission
Radiated disturbance V-3/2015.04 Radiated disturbance at above 1 GHz V-3/2015.04 NA Conducted disturbance V-3/2015.04 Conducted disturbances at
V-3/2015.04 NA
telecommunication ports Note 1: C=Complies NC=Not Complies NT=Not Tested NA=Not Applicable * The data in this test report are traceable to the natio nal or international standards.
Frequency range to be scanned:
0.15 MHz - 30 MHz as conducted measurement 30 MHz – 1 000 MHz (1 GHz) as radiated measurement
Status (note 1)
C
C
Bandwidth: Measured by the CISPR quasi-peak function Bandwid th is 10 kHz i n the frequency 0.15 MHz to 30 MHz, 120 kHz i n the frequency 30 MHz t o 1,000 MHz.
A sample calculation: COR. F (correction factor)= Antenna factor + Cable loss- Amp.gain- Distance correction Emission Level= meter reading + COR.F
The tests have been conducted with the following operational mode(s) of the EUT. Name of mode in the report Description Operating mode : -
- None
Copyright © 2017, LTA CO., LTD. Page 6 of 29
Page 7
1-4 List of EUT and accessory
Cameo® Keypad, Standa r d
Mount
Dual-Technology Occup ancy
Sensor with C resnet®
DIN Rail Cresnet®
Distribution Hub
DIN Rail 60 Watt Cresnet®
Power Supply
1-5 Cable List
Remarks
From
to
DIN Rail Cresnet®
Distribution Hub
DIN Rail 60 Watt Cresnet®
Power Supply
DIN Rail 60 Watt Cresnet®
Power Supply
Dual-Technology Occupancy
Sensor with C resnet®
EUT
Certification No. : LR500171707E
Category Model Name Serial No. Manufacturer Remarks
ACCESSORY
Category Model Name Serial No. Manufacturer Remarks
Cable List
Cable Type Length (m)
C2N-CBD-P
GLS-ODT-C-CN N/A Crestron Electronics. Inc. -
DIN-HUB N/A Crestron Electronics. Inc. -
DIN-PWS60 N/A Crestron Electronics. Inc. -
1.5 NO/NO NET C NET
1.0 NO/NO NET NET HOST
1.5 NO/NO NET INPUT
1.0 NO/NO NET NE T C
N/A
Shielding
(Cable/backshell)
Crestron E l ect ronics. Inc. -
AC Power Source 1.2 NO/NO 3 Pin AC Line AC IN
Copyright © 2017, LTA CO., LTD. Page 7 of 29
Page 8
Certification No. : LR500171707E
1-6 Block diagram of the EUT test / Operating mode
NET
3 Pin AC Line
2 Pin AC Line
DIN Rail 60 Watt
Note) refer to the Test setup photograph.
Cresnet® P ower Supply
DIN Rail Cresnet®
Distribution Hub
Dual-Technology
Occupancy Sensor with
EUT
Copyright © 2017, LTA CO., LTD. Page 8 of 29
Page 9
Certification No. : LR500171707E
2- Test Site Description
1-Facility
All the testing facilities are periodically serviced as a daily check for equipment and cables systems, an every 6
telecommunication ports CONDUCTED EMISSIONS TESTING
2-1 Radiated Disturbance Measurement
2-2 Conducted Disturbance Measurement
EUT
Turn Table
Metal Ground Plane Size(7.2mx16m~7.2mx40m)
Antenna to ground
distance 1m t o 4m
Antenna to EUT Distance
Amplifier
EMI Receiver
Biconical Antenna
Log Antenna
or Double Ridged Guide Antenna
EUT Room
change the Antenna with each frequency
0.8m
Horizontal ground Plane
Pulse limitor
EMI Receiver
AMN
Bonded
to
horizontal
ground plane
connectio ns for equipment
EUT
0.8m
Vertical ground Plane
0.4m
months facility check for the facilities and a monthly check and annual calibration for testing equipment according to ISO/IEC 17025. All the testing facilities are used as the same specifications shown below. There are descriptions both for radiated disturbance measurement and conducted di s t urbance mea surement conformed by VCCI RULES AND REGULATIONS OF CLASS B (V-3 / 2015.04 Normative ANNEX1:Technical Requiremen ts)
10m/3m
-periodic
Copyright © 2017, LTA CO., LTD. Page 9 of 29
Page 10
Certification No. : LR500171707E
2-3 Conducted Disturbances at telecommunication ports
Antenna to ground
Diagram 3 : Telecom Port Conducted Emissions Test Setup
EUT
40cm
Current probe
CDN/ISN
AE
2)
10cm 80cm
No restriction on length
AE = Assoclated equipment EUT
(if applied)
1)
2-4 Radiated Disturbance at above 1 GHz
dista nce 1m t o 2m by size of EUT
= Equipment under test
Copyright © 2017, LTA CO., LTD. Page 10 of 29
Page 11
Certification No. : LR500171707E
3- Test Procedure
3-1 Radiated Disturbance Measurements
Test site is met the requirements of VCCI RULES AND REGULATIONS OF CLASS A
(V-3 / 2015.04 Normative ANNEX1:Technical Requirements) and the distance between the EUT
and the antenna is adjusted 3 m or 10m.
・The turntable can be rotated 360 degrees. ・The antenna can be adjusted between 1m and 4m in height above the ground. ・The EUT is placed on the non-conducti ng t able with 0.8m height on the turntable. ・Measurements are carried out using a spectrum analyzer with peak detectors (100kHz bandwidth) and
an EMI receiver with quasi-peak detectors(120 kHz bandwidt h).
・Refer to the list of test equipment used for the test. ・Biconical antenna and logperiodic antenna are used as wideband antenna. ・The Biconical antenna is used in the frequency range of 30 MHz to 300 MHz and the Logperiodic antenna
is used in the frequency range of 300 MHz to 1 GHz.
・A variable attenuator is used for verifying amplifier’s linearity. ・Rotating the turntable and adjusting the height of the antenna are carried o ut by control buttons on the console. ・Refer to "Brief Information"(page 6-9) about details of the EUT and configuration of the cables.
Measurement is carried out by a LTA operator as manual operation.
–searchin g for some of H igh disturbance frequency points than the other points with the following settings; bandwidth 100 kHz, frequency range 10 MHz between 30 MHz and 300 MHz and frequency range 50 MHz between 300 MHz and 1 GHz. –searching the worst direction with the maximum level of the disturbance wave in rotating the turntable 360 degrees at each searched frequency point. –setting the height of t he antenna with the maximum level of the disturbance wa ve from 1m to 4 m. –reading the disturbance level by the EMI receiver with quasi-peak detectors (120 kHz band width) according to VCCI RULES AND REGULATIONS OF CLASS A
(V-3 / 2015.04 Normative ANNEX1:Technical Requirements) –measuring to vertical and horizo ntal polarization. –calculating the measurement result with the following for mula or equation: (Measurement result= measured value + antenna factor + antenna cable loss)
Copyright © 2017, LTA CO., LTD. Page 11 of 29
Page 12
Certification No. : LR500171707E
3-2 Conducted Disturbance Measurements
・The measurement is carried out on an open site with horizontal and metallic ground plane. ・An AMN(Artificial Mains Network) with a nominal impedance (50 Ω/50 μH) as defined
in VCCI RULES AND REGULATIONS OF CLASS A (V-3 / 2015.04 Normative ANNEX1:Technical
Requirements). shall be utilized .
The AMN is grounded on a horizontal metal ground plane. Measurement is carried out using a spectrum analyzer with peak detectors (10kHz bandwidth) and
an EMI receiver with quasi-peak detectors and average detector. (Refer to the List of test equipment used for the test.)
The shortest distance between the EUT and the AMN is 0.8 m. The EUT is placed on the non-conducti ng t able with 0.8 m height. A remote switch is used for changing phases between Li ne (L) and Neutral (N).Refer to "Brief Information"(page 6-9) ab o ut details of the EUT and configuration of the cables.
Measurement is carried out as manual operation.
–detecting the maximized emission level using the maxhold function after setting the spectrum
analyzer bandwidth 1MHz and the frequency range from 150 kHz to 1 MHz , 1 MHz to 5 MHz and 5 MHz to 30 MHz.
–searchin g the maximum frequenc y point of the disturbance wave in ea ch frequency range . –reading the disturbance level of quasi-peak, average and Line (L) and Neutral (N) in 10 kHz bandwidth by the EMI receiver. –calculating the measurement result with the following for mula or equation. (Result = Reading + Cor.F.) (Margin = Limit- Result)
Copyright © 2017, LTA CO., LTD. Page 12 of 29
Page 13
Certification No. : LR500171707E
3-3 Conducted Disturbances at telecommunication ports Measurements
3-4 Radiated Disturbance at above 1 GHz
In the range of 0.15 MHz to 30 MHz, the conducted disturbance was measured and set-up was made accordance with VCCI V -3/2015.04, CLASS A ITE. The EUT is placed on a non-conducting table, which is: 0.8 meters above an earth-grounded floor; 0.4 meters away from a vertical ground plane (i.e. the chamber wall); and 0.8 meter away from all other metal objects. For cables where there is no appropriate CDN / ISN available, measurement was done using a combination of current probe and capacitive voltage probe.
Measure current with a current probe.
Measure voltage with a capacitive probe
Compare the measured voltage wit h the vo lta ge limit.
Compare the measured current with the current limit.
The EUT shall meet both the voltage and current limits.
Test site is met the requirements of V CCI V-3/2015.04 and the distance between the EUT and the antenna is adjusted 3 m. The turntable can be rotated 360 degrees. The antenna can be adjusted between 1m in height above the ground. The EUT is placed on the non-conductin g table with 1m height on the turntable. Measurements are carried out using a EMI test receiver with peak detectors (1 MHz bandwidth) and an EMI receiver with peak and average detectors(1 MHz bandwidt h). Refer to the list of test equipment used for the test. HORN antenna are used as wideband antenna. The HORN antenna is used in the frequency range of 1 GHz to 18 GHz. A variable attenuator is used for verifying amplifier’s linear ity. Rotating the turntab l e and adjusting the height of the antenna are carried out by contro l buttons on the console . Refer to "Brief Information"(page 6-9) about details of the EUT and configuration of the cables. Measurement is carried out by a LTA operator as manual operation. –searching the worst direction with the maximum level of the disturbance wave in rotating the turntable 360 degrees at each searched frequency point. –setting the height of the antenna wit h the maximum level of the disturbance wave from 1m –reading the disturbanc e level by the EMI receiver with peak and average detectors (1 MHz bandwidth) according to ANSI C 63.4:2003. –measuring to vertical and horizo ntal p olarization. –calculating the measurement result with the following for mula or eq uation: (Measurement result= measured value + antenna factor + antenna cable loss)
Copyright © 2017, LTA CO., LTD. Page 13 of 29
Page 14
Certification No. : LR500171707E
DIGITA L THERMO HYGROMETER
DIGITA L THERMO HYGROMETER
Spectrum Analyzer (~ 26.5 ㎓)
4- List of Equipment Used For the Tests
1
EMI TEST Receiver
2
Pulse Limiter
3
4
DTV Signal Gene rator
5
Color TV Pattern Generator
6
LISN
7
LISN(main)
8
LISN(sub)
9
ISN
10
ISN
11
CURRENT PROBE
12
LISN
13
EMI TEST Receiver
14
Amplifier (25 ㏈)
15
Description Model No. Serial No. Manufacturer Interval
LAST Cal.
ESR 101499 Rohde & Schwarz 1 year Jul-17
ESH3-Z2 100710 Rohde & Schwarz 1 year Mar-17
TH-611 NONE BODYCOM 1 year Sep-16
MFG-100 15M2002 MFLO 1 year Mar-17
PM-5518-TX LO5333 Philips - -
ESH3-Z6 100378 Rohde & Schwarz 1 year Sep-16 ESH3-Z5 893045/017 Rohde & Schwarz 1 year Mar-17
ENV216 100408 Rohde & Schwarz 1 year Sep-16
ISN T800 27109 TESEQ 1 year Jan-17
ENY81-CA6 101565 Rohde & Schwarz 1 year Jan-17
EZ-17 100508 Rohde & Schwarz 1 year Jan-17
ESH3-Z6 100378 Rohde & Schwarz 1 year Sep-16
ESCI7 100772 Rohde & Schwarz 1 year Sep-16 8447D 2944A07974 HP 1 year Sep-16
TESTEK-303A TAEGUANG - 1 year Mar-17
16
Log.-Per. Antenna
17
Biconical Antenna
18
TRILOG Antenna
19
TRILOG Antenna
20
Amplifier (25 ㏈)
21
22
HORN ANTENNA
23
HORN ANTENNA
24
TRILOG Antenna
25
HORN ANTENNA
VULP 9118 9118 A 401 SCHWARZBECK 2 year Apr-17
VHA 9103 VHA 9103-2315 SCHWARZBECK 2 year Apr-17 VULB9160 9160-3237 SCHWARZBECK 2 year May-17 VULB9160 9160-3242 SCHWARZBECK 2 year Jul-16
8449B 3008A00337 HP 1 year Mar-17
E4407B MY45108946 Agilent 1 year Mar-17
3115 114105 ETS 2 year May-16 3115 114105 ETS 2 year Jul-16
VULB9268 775 SCHWARZBECK 2 year Mar-17
3115 000550005 ETS 2 year May-17
Copyright © 2017, LTA CO., LTD. Page 14 of 29
Page 15
Certification No. : LR500171707E
5-1 Radiated Disturbance Measurements (Below 1GHz) / V
TEST EQUIPMENT USED: 13, 14, 15, 18
Copyright © 2017, LTA CO., LTD. Page 15 of 29
Page 16
(Below 1GHz) / H
-Continue
Certification No. : LR500171707E
Copyright © 2017, LTA CO., LTD. Page 16 of 29
Page 17
Certification No. : LR500171707E
(LINE) / 50
5-2 Conducted disturbance Measurements
TEST EQUIPMENT USED: 01, 02, 03, 07
Copyright © 2017, LTA CO., LTD. Page 17 of 29
Page 18
(NEUTRAL) / 50
-Continue
Certification No. : LR500171707E
Copyright © 2017, LTA CO., LTD. Page 18 of 29
Page 19
Certification No. : LR500171707E
(LINE) / 60
5-2 Conducted disturbance Measurements
TEST EQUIPMENT USED: 01, 02, 03, 07
Copyright © 2017, LTA CO., LTD. Page 19 of 29
Page 20
(NEUTRAL) / 60
-Continue
Certification No. : LR500171707E
Copyright © 2017, LTA CO., LTD. Page 20 of 29
Page 21
Certification No. : LR500171707E
Conclusions
Product models " C2N-CBD-P " meets all of the CLASS A requirements of the VCCI RULES AND REGULATIONS OF CLASS A (V-3 / 2015.04 Normative ANNEX1:Technical Requirements) (Limits of radio disturbance characteristics of ITE). ( Refer to Test Specification and Test Results in the "LTA certification", page 4 and 5.)
Copyright © 2017, LTA CO., LTD. Page 21 of 29
Page 22
Certification No. : LR500171707E
Photograph of the Radiated Disturbance Measurements (Below 1GHz)
Copyright © 2017, LTA CO., LTD. Page 22 of 29
Page 23
Certification No. : LR500171707E
Photograph of the Conducted disturbance Measurements (Maximum emission configuration)
Copyright © 2017, LTA CO., LTD. Page 23 of 29
Page 24
Certification No. : LR500171707E
Photograph of the Equipment Under Test
Copyright © 2017, LTA CO., LTD. Page 24 of 29
Page 25
Certification No. : LR500171707E
Photograph of the Equipment Under Test
Copyright © 2017, LTA CO., LTD. Page 25 of 29
Page 26
Certification No. : LR500171707E
Photograph of the Equipment Under Test
Copyright © 2017, LTA CO., LTD. Page 26 of 29
Page 27
Certification No. : LR500171707E
Photograph of the Equipment Under Test
Copyright © 2017, LTA CO., LTD. Page 27 of 29
Page 28
Certification No. : LR500171707E
Photograph of the Equipment Under Test
Copyright © 2017, LTA CO., LTD. Page 28 of 29
Page 29
Certification No. : LR500171707E
Photograph of the Equipment Under Test
Copyright © 2017, LTA CO., LTD. Page 29 of 29
Loading...