LS Starvert iG5A is very competitive in its price and shows an upgraded functional strength.
User-friendly interface, extended drive ranges up to 22kW,
superb torque competence and small size of iG5A provides an optimum use environment.
Standard
compliance
Compactness
iG5A
High
performance
User-
friendliness
& Easy
maintenance
2
Compact & Powerful Drive iG5A
Contents
Overview
4
Model & Type
8
Standard Specifications
9
Wiring
11
Terminal Configurations
13
Keypad Features
15
Parameter Setting
16
Trial Run
18
Dimensions
20
Braking Resistors and Peripheral Devices
23
Function List
25
Protective Functions
42
Fault Remedy
43
Drive Starvert iG5A Series
3
iG5A
Powerful & Upgraded Performance
iG5A provides sensorless vector control, PID control,
and ground-fault protection through powerful built-in functions.
Sensorless vector control
The built-in sensorless vector control provides
the superb speed control and powerful high
torque.
Ground-fault protection
during running
The ground-fault protection of output terminal
is possible during running.
Analog control from -10V to 10V
Inputting analog signals from -10V to 10V
provides user-friendly operation.
Built-in PID control
The built-in PID function enables to control
flow-rate, oil-pressure, temperature, etc
without any extra controller.
Speed vs Torque Characteristics
Torque (%)
Sensorless Vector Control Mode: Auto tuning Measure maximum
Condition:
torque (%) at each speed (1/5/10/20/30/40/50/60Hz)
+10
-10
Forward
Reverse
PID controlPID control
Pl controlPI control
Speed (Hz)
Built-in dynamic braking circuit
The built-in dynamic braking circuit minimizes
Speed
deceleration time via braking resistors.
Built-in 485 communication
With braking resistor
Normal state
Reducing
deceleration time
Time
The built-in RS-485 communication supports
remote control and monitoring between iG5A
and other equipment.
Wide product range
iG5A consists of the product range from 0.4 to 22KW.
4
RS-485 communication
Connected to PC
RS-485 - 232C converter
Monitoring
Checking operation status
(Voltage, Current, Frequency, etc)
Checking modified parameters
Windows support
Compact & Powerful Drive iG5A
Remote Control
Convenient remote control to modify operation status
(Forward/Reverse operation, Frequency, etc)
Easy parameter setting
Available to control up to 31 Drives
RS-485, Modbus communication
Connected to XGT panel
Monitoring
Checking operation time
Automatic list-up of trip record
Language support (Korean, English, Chinese)
Remote Control
Convenient remote control to modify operation status
(Forward/Reverse operation, Frequency, etc)
Easy parameter setting
Available to control up to 31 Drives
RS-485, Modbus communication
Drive Starvert iG5A Series
5
iG5A
User-friendly Interface & Easy Maintenance
The parameter setting becomes easier by adopting the 4 directions key. And iG5A supports
easy maintenance via diagnosis and fan changeable structure.
Diagnosis of output module
Through easy parameter setting, iG5A can diagnose the
status of output module.
Easy change of fan
iG5A is designed to be the fan changeable structure in
preparation for a fan breakdown.
Cooling fan control
By controlling the cooling fan, iG5A provides a virtually
quiet environment according to the status of operation.
User-friendly interface
The 4 directions key provides easy handling and
monitoring.
External loader (Optional)
The external loader away from a panel enables to control
and monitor conveniently. And the parameters made by
external loader can be copied and applicable to other
Drives.
The compact size achieves cost-efficiency and various applications.
Same height from 0.4 to 4.0kW (128mm)
Compact & Powerful Drive iG5A
Global standard compliance
CE UL
Global standard
iG5A series complies with CE and UL standards.
PNP/NPN input
Both PNP and NPN inputs become possible and these enable to
use the outer power.
To do so, users will be given wider choices of selecting the
controller.
1) Indicate the maximum applicable motor capacity when using 4 pole LS standard motor.
2) Rated capacity is based on 220V for 200V series and 440V for 400V series.
3) Refer to 15-3 of userʼs manual when carrier frequency setting (39) is above 3kHz.
4) Max. frequency setting range is extended to 300Hz when H40 (Control mode select) is set to 3 (Sensorless vector control).
5) Max. output voltage cannot be higher than the input voltage. It can be programmable below input voltage.
6) Self-Cooling
iG5A-4
(HP)
(kW)
Capacity (kVA)
3)
FLA (A)
Max frequency
Max voltage
Rated voltage
Rated frequency
2)
004008015022037040055075110150185220
0.5
0.4
0.95
1.25
0.76
1
2
3
5
5.4
7.5
0.75
1.5
2.2
3.7
4.0
5.5
1.9
3.0
4.5
6.1
6.5
9.1
2.5
6)
0.77
4
1.12
6
8
9
12
400 [Hz]
3 phase 380~480V
3 phase 380~480 VAC (+10%, -15%)
50~60 [Hz] (±5%)
1.84
1.89
1.89
4)
Forced air cooling N/C
3.66
10
7.5
12.2
16
5)
3.66
15
20
25
11
15
18.5
18.3
22.9
29.7
24
30
39
9.0
9.0
13.3
Drive Starvert iG5A Series
30
22
34.3
45
13.3
9
iG5A
Standard Specifications
Control
Operation
Control method
Frequency setting resolution
Frequency accuracy
V/F pattern
Overload capacity
Torque boost
Dynamic
braking
Operation mode
Frequency setting
Operation features
Input
Max. braking
torque
Max. Duty
Multi-function
terminal
P1~P8
V/F, Sensorless vector control
Digital command: 0.01Hz
Analog command: 0.06Hz (Max. freq.: 60Hz)
Digital command: 0.01% of Max. output frequency
Analog command: 0.1% of Max. output frequency
Linear, Squared, User V/F
150% per 1 min.
Manual/Auto torque boost
1)
20%
150% when using optional DB resistor
Keypad/ Terminal/ Communication option/ Remote keypad selectable
Analog: 0~10V, -10~10V, 0~20mA
Digital: Keypad
PID, Up-down, 3-wire
NPN/PNP selectable
FWD/REV RUN, Emergency stop, Fault reset, Jog operation, Multi-step Frequency-High, Mid, Low,
Multi-step Accel/Decel-High, Mid, Low, DC braking at stop, 2nd motor select, Frequency UP/Down,
3-wire operation, External trip A, B, PID-Drive (V/F) operation bypass,
Option-drive (V/F) operation bypass, Analog Hold, Accel/Decel stop
2)
Open collector
terminal
Output
Trip
Protective
function
Environ
ment
1) Means average braking torque during Decel to stop of a motor.
2) Refer to Chapter 16 of userʼs manual for DB resistor specification.
Alarm
Momentary power loss
Protection degree
Ambient temp
Storage temp
Humidity
Altitude/Vibration
Atmospheric pressure
Location
Multi-function relay
Analog output (AM)
Fault output and
drive status output
0~10Vdc (less than 10mA): Output freq, Output current, Output voltage, DC link selectable
Over voltage, Under voltage, Over current, Ground fault current detection, Drive overheat,
Motor overheat, Output phase open, Overload protection, Communication error,
Loss of speed command, Hardware fault, Fan trip
Stall prevention, Overload
Below 15 msec.: Continuous operation (Should be within rated input voltage, rated output power.)
Above 15 msec.: Auto restart enable
IP 20, NEMA1 (Optional)
-10℃~50℃
-20℃~65℃
Below 90% RH (No condensation)
Below 1,000m, 5.9m/sec2 (0.6G)
70~106 kPa
Protected from corrosive gas, Combustible gas, Oil mist or dust
Less than DC 24V, 50mA
(N.O., N.C.) Less than AC 250V, 1A; Less than DC 30V, 1A
10
Wiring
0.4~7.5kW
3 phase AC input
(Rated input voltage)
Compact & Powerful Drive iG5A
DB resistor
(Optional)
B1B2
Ground
R
S
T
G
24V output
24
FX (Forward run)
P1
RX (Reverse run)
P2
Input signal common
CM
BX (Emergency stop)
P3
RST (Trip reset)
P4
JOG (Jog operation)
P5
Input signal common
CM
Multi-step freq. - Low
P6
Multi-step freq. - Middle
P7
U
W
AM
CM
V
Multi-function
analog output
signal: 0~10V
A contact output
3A
A/B contact common
3C
B contact output
3B
Potentiometer
(1kohm, 1/2W)
Multi-step freq. - High
P8
10V power supply for potentiometer
VR
Freq. Setting Voltage signal input: -10~10V
V1
Freq. Current signal input: 0~20mA
I
Input signal common
CM
Multi-function open
MO
collector output
MO Common
MG
S+
RS-485 communication terminal
S-
Drive Starvert iG5A Series
11
iG5A
Wiring
11.0~22.0kW
3 phase AC input
(Rated input voltage)
Ground
DC reactor
P1(+)B1 B2N(-)
R
S
T
G
24V output
24
FX (Forward run)
P1
RX (Reverse run)
P2
Input signal common
CM
BX (Emergency stop)
P3
DB resistor
(Optional)
U
V
W
AM
CM
Multi-function
analog output
signal: 0~10V
Potentiometer
(1kohm, 1/2W)
RST (Trip reset)
P4
JOG (Jog operation)
P5
Input signal common
CM
Multi-step freq. - Low
P6
Multi-step freq. - Middle
P7
Multi-step freq. - High
P8
10V power supply for potentiometer
VR
Freq. Setting Voltage signal input: -10~10V
V1
Freq. Current signal input: 0~20mA
I
Input signal common
CM
A contact output
3A
A/B contact common
3C
B contact output
3B
Multi-function open
MO
collector output
MO Common
MG
S+
RS-485 communication terminal
S-
12
Wiring
Specifications for power terminal block wiring
•
•
0.4kW~0.75kW (1 phase)
0.4kW~1.5kW (3 phase)
•
1.5kW (1 phase)
Compact & Powerful Drive iG5A
RTB1B1
•
5.5kW~7.5kW (3 phase)
B1
SV0004iG5A-1
SV0008iG5A-1
SV0015iG5A-1
SV0004iG5A-2
SV0008iG5A-2
SV0015iG5A-2
SV0022iG5A-2
SV0037iG5A-2
SV0040iG5A-2
SV0055iG5A-2
SV0075iG5A-2
SV0110iG5A-2
SV0150iG5A-2
SV0185iG5A-2
SV0220iG5A-2
SV0004iG5A-4
SV0008iG5A-4
SV0015iG5A-4
SV0022iG5A-4
SV0037iG5A-4
SV0040iG5A-4
SV0055iG5A-4
SV0075iG5A-4
SV0110iG5A-4
SV0150iG5A-4
SV0185iG5A-4
SV0220iG5A-4
B2
B2B2
UU
U
WW
VV
W
V
R, S, T wireU, V, W wireGround wire
2
mm
2
2
2
2
2
2
2
3.5
3.5
5.5
8
14
22
30
38
2
2
2
2
2
2
3.5
3.5
5.5
14
14
22
R
AWGmm
14
14
14
14
14
14
14
12
12
10
8
6
4
2
2
14
14
14
14
14
14
12
12
10
6
6
4
2
2
2
2
2
2
2
3.5
3.5
5.5
8
14
22
30
30
2
2
2
2
2
2
2
3.5
5.5
8
8
14
T
2
•
11~22kW (3 phase)
(L1) S(L2)T(L3) P1(+)N(-)
AWGmm
14
14
14
14
14
14
14
12
12
10
8
6
4
2
2
14
14
14
14
14
14
14
12
10
8
8
6
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
5.5
5.5
14
14
22
22
2
2
2
2
2
2
3.5
3.5
8
8
14
14
•
2.2~4.0kW (3 phase)
RRSS
2
AWG
12
12
12
12
12
12
12
12
12
10
10
6
6
4
4
14
14
14
14
14
14
12
12
8
8
6
6
B1
T
B1
T
B1R
B2
Terminal
Screw Size
M3.5
M3.5
M4
M3.5
M3.5
M3.5
M4
M4
M4
M5
M5
M6
M6
M8
M8
M3.5
M3.5
M4
M4
M4
M4
M5
M5
M5
M5
M6
M6
B2
B2
U
V
U
V
U
V
Screw Torque
(kgf.cm) / lb-in
10/8.7
10/8.7
15/13
10/8.7
10/8.7
10/8.7
15/13
15/13
15/13
32/28
32/28
30.7/26.6
30.7/26.6
30.5/26.5
30.5/26.5
10/8.7
10/8.7
15/13
15/13
15/13
15/13
32/28
32/28
30.7/26.6
30.7/26.6
30.5/26.5
30.5/26.5
W
W
W
Drive Starvert iG5A Series
13
iG5A
Terminal Configuration
Control terminal specifications
MO MG24P1P2CMP3P4S-S
3A3B3CP5 CMP6P7P8VRV1IAM
Terminal
P1~P8
CM
VR
V1
I
AM
MO
MG
24
3A
3B
3C
1) Use the recommended tightening torque when securing terminal screws.
※ When you use external power supply (24V) for multi-function input terminal (P1~P8), apply voltage higher than 12V to activate.
※ Tie the control wires more than 15cm away from the control terminals. Otherwise, it interferes front cover reinstallation.
1) 4 LEDs above are set to blink when a fault occurs.
Right key
Left key
Enter key
Forward run
Reverse run
Run key
Setting
Dimensions
2-Φ4.5
Term
Run command
STOP
:
RESET
Used to scroll through codes or increase parameter value
Used to scroll through codes or decrease parameter value
Used to jump to other parameter groups or move a cursor to
the right to change the parameter value
Used to jump to other parameter groups or move a cursor to
the left to change the parameter value
Used to set the parameter value or save the changed parameter value
Lit during forward run
Lit during reverse run
Lit during operation
Lit during parameter setting
95
83
70
C
L
SETFWD
RUN
RUN
ENT
REV
RESET
Description
Stop command during operation,
:
Reset command when a fault occurs.
36.2
STOP
72.4
3.4
65.6
513.9
2.123.1
Drive Starvert iG5A Series
15
iG5A
Moving to Other Groups
Parameter groups
There are 4 different parameter groups in iG5A series as shown below.
Parameter group
Drive group
Function group 1
Function group 2
I/O (Input/Output) group
Moving to other groups
Moving to other groups using the Right (
Description
Basic parameters necessary for the drive to run. Parameters such as Target frequency, Accel/Decel time settable.
Basic function parameters to adjust output frequency and voltage.
Advanced function parameters to set parameters for such as PID Operation and second motor operation.
Parameters necessary to make up a sequence using multi-function input/output terminal.
▶
) keyMoving to other groups using the Left (◀) key
1)1)
1) Target frequency can be set at 0.0 (the 1st code of drive group). Even though the preset value is 0.0, it is user-settable.
The changed frequency will be displayed after it is changed.
16
When changing ACC time from 5.0 sec to 16.0 sec
Compact & Powerful Drive iG5A
1
•
In the first code “0.00”, press the Up (▲) key once to go to the second code.
•
2
3
4
5
6
7
8
1) Pressing the Left (◀)/Right (▶)/Up (▲)/Down (▼) key while a cursor is blinking will cancel the parameter value change.
Pressing the Ent (●) key in this status will enter the value into memory.
※ In step 7, pressing the Left (◀) or Right (▶) key while 16.0 is blinking will disable the setting.
ACC [Accel time] is displayed.
•
Press the Ent (●) key once.
•
Preset value is 5.0, and the cursor is in the digit 0.
•
Press the Left (◀) key once to move the cursor to the left.
•
The digit 5 in 5.0 is active. Then press the Up (▲) key once.
•
The value is increased to 6.0
•
Press the Left (◀) key to move the cursor to the left.
•
0.60 is displayed. The first 0 in 0.60 is active.
•
Press the Up (▲) key once.
•
16.0 is set.
•
Press the Ent (●) key once.
•
16.0 is blinking.
•
Press the Ent (●) key once again to return to the parameter name.
•
ACC is displayed. Accel time is changed from 5.0 to 16.0 sec.
1)
Code change in Drive group
•
1
2
3
4
5
•
Use Down (▼) key for the opposite order.
In the 1st code in Drive group “0.00”,
press the Up (▲) key once.
•
The 2nd code in Drive group “ACC”is displayed.
•
Press the Up (▲) key once.
•
The 3rd code “dEC” in Drive group is displayed.
•
Keep pressing the Up (▲) key until the last code appears.
•
The last code in Drive group “drC” is displayed.
•
Press the Up (▲) key again.
•
Return to the first code of Drive group.
Drive Starvert iG5A Series
17
iG5A
Trial Run
Multi-step operation + Run/Stop via FX/RX + Max. frequency change
Operation condition
Operation command:
Run/Stop via FX/RX
Wiring
Frequency command:
Multi-step operation [Low (20), Middle (30), High (80)]
Max. frequency change:
From 60Hz to 80Hz
S1
S2
S3
S4
S5
1. Please make sure that R, S, T are connected to 3 phase AC input, and
U, V, W are also motor connection terminals.
2. After supplying the power, please set the frequency of multi-step among
Low, Middle, and High.
3. If P1 (FX) turns on, the motor operates in forward. And after turning off,
it stops according to the deceleration time.
4. If P2 (RX) turns on, the motor operates in reverse. And after turning off,
it stops according to the deceleration time.
P1 (Forward)
P2 (Reverse)
3 phase
AC input
P6 (Low)
P7 (Middle)
P8 (High)
CM
S / W
R
S
T
G
P1 (Forward)
P2 (Reverse)
P6 (Low)
P7 (Middle)
P8 (High)
CM
VR
V1
CM
U
V
W
Parameter setting
StepCommandAfter changeDefault
1
Max. frequency change (FU1)
2
Multi-step frequency (DRV)
3
Multi-step frequency (DRV)
4
Multi-step frequency (I/O)
5
Forward run (P1: FX)
6
Reverse run (P2: RX)
Code
F21
st1
st2
I30
I17
I18
Change Max. frequency.
Set ‛Low’ step.
Set ‛Middle’ step.
Set ‛High’ step.
The default is FX. This value may change.
The default is RX. This value may change.
18
Description
60Hz
10Hz
20Hz
30Hz
FX
RX
80Hz
20Hz
30Hz
80Hz
FX
RX
Potentiometer (Volume) + Run/Stop via FX/RX + Accel/Decel time change
Operation condition
Operation command:
Run/Stop via FX/RX
Frequency command:
0~60Hz analog input via potentiometer
Accel/Decel time:
Accel-10sec, Decel-20sec
Wiring
Potentiometer 1~5kohm, 1/2W
3
0~60Hz
2
1
VR
V1
CM
3 phase
AC input
R
S
T
G
P1 (FX) Forward
P2 (RX) Reverse
Compact & Powerful Drive iG5A
Motor
U
V
W
1. Please make sure that R, S, T are connected to 3 phase AC input,
and U, V, W are also motor connection terminals.
2. After supplying the power, please set the frequency of multi-step
among Low, Middle, and High.
3. If P1 (FX) turns on, the motor operates in forward. And after
turning off, it stops according to the deceleration time.
4. If P2 (RX) turns on, the motor operates in reverse. And after
turning off, it stops according to the deceleration time.
This parameter selects the parameter to be displayed on the
keypad when the input power is first applied.
0 Frequency command
1 Accel time
2 Decel time
3 Drive mode
4 Frequency mode
5 Multi-Step frequency 1
6 Multi-Step frequency 2
7 Multi-Step frequency 3
8 Output current
9 Motor rpm
10 Drive DC link voltage
11 User display select (H73)
12 Fault display
13 Direction of motor rotation select
14 Output current 2
15 Motor rpm 2
16 Drive DC link voltage 2
17 User display select 2
One of the following can be monitored via vOL - [User display
select].
0 Output voltage [V]
1 Output power [kW]
2 Torque [kgf,m]
This parameter is used to change the motor rotating speed (r/
min) to mechanical speed (m/mi) and display it.
0 Unlimited
1 Use DB resistor for the H76 set time.
Set the percent of DB resistor operating rate to be activated
during one sequence of operation.
0 Always ON
Keeps ON when its temp is higher than drive protection
1
limit temp. Activated only during operation when its temp
is below that of drive protection limit.
0 Continuous operation when cooling fan malfunctions.
1 Operation stopped when cooling fan malfunctions.
This parameter displays the drive software version.
Description
Factory
defaults
1 O
0 O
0 O
100 O
1 O
10 O
0 O
0 O
1.0 X
Adj.
during run
34
Function group 2
Compact & Powerful Drive iG5A
LED
display
H81
H82
H83
H84
H85
H86
H87
H88
Address for
communication
1)
Accel time] 0 ~ 6000
A352
Decel time]
A353
base frequency] [Hz]
A354
V/F pattern]
A355
torque boost] 0 ~ 15
A356
torque boost]
A347
prevention level] [%]
[2nd motor
A351
[2nd motor [sec]
[2nd motor 30 ~ 400
[2nd motor
[2nd motor forward
[2nd motor reverse [%]
[2nd motor stall 30~150
Parameter
name
Min/Max
[2nd motor
A358 Electronic thermal
level for 1 min]
range
0 ~ 2
50~200
[%]
This parameter actives when the selected terminal is ON after
I17-I24 is set to 12 {2nd motor select}.
[2nd motor
H89
thermal level for [%]
Electronic 50~150
A359
continuous]
H90
rated current] [A]
2)
A35B [Parameter read] 0 ~ 1
H91
A35C [Parameter write] 0 ~ 1
H92
[2nd motor 0.1~100
A35A
Copy the parameters from drive and save them into remote
loader.
Copy the parameters from remote loader and save them into
drive.
This parameter is used to initialize parameters back to the
factory default value.
0 -
A35D
H93
[Parameter
initialize]
0 ~ 5
1
2 Only Drive group is initialized.
3 Only Function group 1 is initialized.
4 Only Function group 2 is initialized.
H94
register]
[Password
A35E
A35F [Parameter lock] 0 ~ FFFF
H95
0 ~ FFFF
5 Only I/O group is initialized.
Password for H95-[Parameter lock].
Set as Hexa value.
This parameter is able to lock or unlock parameters by typing
password registered in H94.
UL (Unlock) Parameter change enable
L (Lock) Parameter change disable
1) It is indicated when choosing I17~I24 as a 12 (2nd motor select).
2) H91,H92 parameters are displayed when Remote option is installed.
Description
All parameter groups are initialized to factory default
value.
Factory
defaults
Adj.
during run
5.0 O
10.0 O
60.00 X
0 X
5 X
5 X
150 X
150 O
100 O
26.3 X
0 X
0 X
0 X
0 O
0 O
Drive Starvert iG5A Series
35
iG5A
Function List
Input/output group
LED
display
I 0
I 2
I 3
I 4
I 5
I 6
I 7
I 8
I 9
I10
I11
I12
I13
I14
I15
I16
I17
I18
I19
I20
* See °∞Chapter 14 Troubleshooting and maintenance°± for External trip A/B contact.
* Each multi-function input terminal must be set differently.
Address for
communication
A400 [Jump code] 0 ~ 87
Min voltage] [V]
A403
A404
Max voltage] [V]
A405
A406
for V1 input]
A407
voltage] [V]
A408
A409
voltage] [V]
A40A
A40B
A40C
current] [mA]
A40D
A40E
current] [mA]
A40F
[Criteria for
A410 Analog Input 0 ~ 2
Signal loss]
[Multi-function
A411 input terminal
P1 define]
[Multi-function
A412 input terminal
P2 define]
[Multi-function
A413 input terminal
P3 define]
[Multi-function
A414 input terminal
P4 define]
[NV input 0 ~ -10
A402
[Frequency 0 ~ 400
[NV input 0 ~ -10
[Frequency 0 ~ 400
[V1 input Min 0 ~ 10
[Frequency 0 ~ 400
[V1 input Max 0 ~ 10
[Frequency 0 ~ 400
[Filter time
[I input Min 0 ~ 20
[Frequency 0 ~ 400
[I input Max 0 ~ 20
[Frequency 0 ~ 400
Parameter
name
corresponding to I 2] [Hz]
corresponding to I 4]
[Filter time constant
corresponding to I 7]
corresponding to I 9]
constant for I input]
corresponding to I 12]
corresponding to I 14]
Min/Max
range
[Hz]
0 ~ 9999
[Hz]
[Hz]
0 ~ 9999
[Hz]
[Hz]
0 ~ 27
Sets the code number to jump.
Sets the minimum voltage of the NV (-10V~0V) input.
Sets the drive output minimum frequency at minimum voltage of
the NV input.
Sets the maximum voltage of the NV input.
Sets the drive output maximum frequency at maximum voltage of
the NV input.
Adjusts the responsiveness of V1 input (0 ~ +10V).
Sets the minimum voltage of the V1 input.
Sets the drive output minimum frequency at minimum voltage of
the V1 input.
Sets the maximum voltage of the V1 input.
Sets the drive output maximum frequency at maximum voltage of
the V1 input.
Sets the input sectionʼs internal filter constant for I input.
Sets the minimum current of I input.
Sets the drive output minimum frequency at minimum current of I
input.
Sets the Maximum current of I input.
Sets the drive output maximum frequency at maximum current of
I input.
0 Disabled
1 activated below half of set value.
2 activated below set value.
0 Forward run command
1 Reverse run command
2 Emergency Stop Trip
3 Reset when a fault occurs {RST}
4 Jog operation command
5 Multi-Step freq - Low
6 Multi-Step freq - Mid
7 Multi-Step freq - High
Description
Factory
defaults
1 O
0.00 O
0.00 O
10.0 O
60.00 O
10 O
0 O
0.00 O
10 O
60.00 O
10 O
4.00 O
0.00 O
20.00 O
60.00 O
0 O
0 O
1 O
2 O
3 O
Adj.
during run
36
Input/output group
Compact & Powerful Drive iG5A
LED
display
I21
I22
I23
I24
I25
I26
I27
I30
I31
I32
I33
I34
I35
I36
Address for
communication
[Multi-function
A415 input terminal
P5 define]
[Multi-function
A416 input terminal
P6 define]
[Multi-function
A417 input terminal
P7 define]
0 ~ 27
[Multi-function
A418 input terminal
P8 define]
status display]
A41A
status display]
[Filtering time
A41B
Multi-function
Input terminal]
frequency 4]
A41F
frequency 5] 0 ~ 400
A420
frequency 6]
A421
frequency 7]
A422
time 1]
A423
time 1] [sec]
A424
time 2]
[Input terminal
A419
[Output terminal
constant for
[Multi-Step
A41E
[Multi-Step
[Multi-Step [Hz]
[Multi-Step
[Multi-Accel
[Multi-Decel 0~ 6000
[Multi-Accel
Parameter
name
Min/Max
range
1 ~ 15
Description
8 Multi Accel/Decel - Low
9 Multi Accel/Decel - Mid
10 Multi Accel/Decel - High
11 DC brake during stop
12 2nd motor select
13 -Reserved-
14 -Reserved 15
Up-down
16 Frequency decrease command (DOWN)
17 3-wire operation
18 External trip: A Contact (EtA)
19 External trip: B Contact (EtB)
20 Self-diagnostic function
21 Change from PID operation to V/F operation
22 2nd Source
23 Analog Hold
24 Accel/Decel Disable
25 Up/Down Save Freq. Initialization
26 JOG-FX
27 JOG-RX
BIT7 BIT6 BIT5 BIT4 BIT3 BIT2 BIT1 BIT0
P8 P7 P6 P5 P4 P3 P2 P1
BIT1 BIT0
3AC MO
If the value is set higher, the responsiveness of the Input terminal
is getting slower.
It cannot be set greater than F21 - [Max frequency].
Frequency increase (UP) command
Factory
defaults
4 O
5 O
6 O
7 O
0 O
0 O
4 O
30.00 O
25.00 O
20.00 O
15.00 O
3.0 O
3.0
4.0
Adj.
during run
Drive Starvert iG5A Series
37
iG5A
Function List
Input/output group
LED
display
I37
I38
I39
I40
I41
I42
I43
I44
I45
I46
I47
I50
I51
I52
I53
I54
I55
Address for
communication
time 2]
time 3]
A427
time 3]
A428
time 4]
A429
time 4]
A42A
time 5] [sec]
A42B
time 5]
A42C
time 6]
A42D
time 6]
A42E
time 7]
A42F
time 7]
item select]
level adjustment] [%]
A434
detection level]
[Frequency
A435 detection
bandwidth]
[Multi-function
A436 output terminal
select]
A437
[Multi-Decel
A425
[Multi-Accel
A426
[Multi-Decel
[Multi-Accel
[Multi-Decel
[Multi-Accel 0~ 6000
[Multi-Decel
[Multi-Accel
[Multi-Decel
[Multi-Accel
[Multi-Decel
[Analog output
A432
[Analog output 10~200
A433
[Frequency
Parameter
name
[Multi-function
relay select]
Min/Max
range
0 ~ 3
0 ~ 400
[Hz]
0 ~ 19
Description
Output item
200V 400V
0 Output freq. Max frequency
1 Output current 150 %
2 Output voltage AC 282V AC 564V
3 Drive DC link voltage DC 400V DC 800V
Based on 10V.
Used when I54 or I55 is set to 0-4.
Cannot be set higher than F21.
0 FDT-1
1 FDT-2
2 FDT-3
3 FDT-4
4 FDT-5
5 Overload (OLt)
6 Drive Overload (IOLt)
7 Motor stall (STALL)
8 Over voltage trip (Ovt)
9 Low voltage trip (Lvt)
Output to 10[V]
Factory
defaults
4.0
5.0
5.0
6.0
6.0
7.0
7.0
8.0
8.0
9.0
9.0
0 O
100 O
30.00 O
10.00 O
12
17
Adj.
during run
O
38
Input/output group
Compact & Powerful Drive iG5A
LED
display
I55
I56
I57
I59
I60
I61
I62
Address for
communication
A437
relay select]
A438 [Fault relay output] 0 ~ 7
[Output terminal
communication
error occurs]
A43B [Communication 0 ~ 1
protocol select]
A43C [Drive number] 1 ~ 250
A43D [Baud rate] 0 ~ 4
[Drive mode
A43E
of frequency
command]
[Multi-function
select when
A439
select after loss
Parameter
name
Min/Max
range
0 ~ 19
0 ~ 3
0 ~ 2
Description
10 Drive Overheat (OHt)
11 Command loss
12 During Run
13 During Stop
14 During constant run
15 During speed searching
16 Wait time for run signal input
17 Multi-function relay select
18 Warning for cooling fan trip
19 Brake signal select
When setting the When the trip When the
H26 - [Number of other than low low voltage trip
auto restart try] voltage trip occurs
occurs
Bit 2 Bit 1 Bit 0
0 - - -
1 - -
2 - -
3 -
4 - -
5 -
6 -
7
Multi-function relay
Bit 1 Bit 0
0 - -
1 -
2 -
3
Set communication protocol.
0 Modbus RTU
1 LS BUS
Set for RS485 communication
Select the Baud rate of the RS485.
0 1200 [bps]
1 2400 [bps]
2 4800 [bps]
3 9600 [bps]
4 19200 [bps]
It is used when freq command is given via V1 /I terminal or
RS485.
Continuous operation at the frequency before its
0
command is lost.
1 Free Run stop (Output cut-off)
2 Decel to stop
Multi-function output terminal
Factory
defaults
17 O
2 O
0 O
0 X
1 O
3 O
0 O
Adj.
during run
Drive Starvert iG5A Series
39
iG5A
Function List
Input/output group
LED
display
I63
I64
I65
I66
I67
I68
I69
I70
I71
I72
I73
I74
I75
I76
I77
I78
I79
I80
I81
182
1) It is indicated when choosing I54~I55 as a 19 (Brake signal).
Address for
communication
[Wait time after
A43F loss of frequency
time setting] [ms]
A441
register 1]
register 2]
register 3]
A445
register 4]
A446
register 5]
A447
register 6]
A448
register 7]
A449
register 8]
A44A
register 1]
A44B
register 2]
A44C
register 3]
A44D
register 4]
A44E
register 5]
A44F
register 6]
A450
register 7]
A451
register 8]
1)
A452
current] [%]
[Communication 2 ~ 100
A440
[Read address
A442
[Read address
A443
[Read address
A444
[Read address
[Read address
[Read address
[Read address
[Read address
[Write address
[Write address
[Write address
[Write address
[Write address
[Write address
[Write address
[Write address
[Brake open 0~180
Parameter
name
setting]
[sec]
command]
[Parity/stop bit
0.1 ~ 120
0~3
Min/Max
range
0~42239
0~42239
Description
This is the time drive determines whether there is the input
frequency command or not. If there is no frequency command
input during this time, drive starts operation via the mode
selected at I62.
Frame communication time
When the protocol is set, the communication format can be set.
0 Parity: None, Stop Bit: 1
1 Parity: None, Stop Bit: 2
2 Parity: Even, Stop Bit: 1
3 Parity: Odd, Stop Bit: 1
The user can register up to 8 discontinuous addresses and read
them all with one Read command.
The user can register up to 8 discontinuous addresses and write
them all with one Write command
Sets current level to open the brake.
It is set according to H33ʼs (motor rated current) size
Factory
defaults
1.0 O
5 O
O O
5
6
7
8
O
9
10
11
12
5
6
7
8
O
5
6
7
8
50.0 O
Adj.
during run
40
Input/output group
Compact & Powerful Drive iG5A
LED
display
183
184
185
186
187
Address for
communication
A453
delay time] [s]
A454
frequency] [Hz]
A455
` frequency] [Hz]
A456
delay time] [s]
A457
frequency [Hz]
[Brake open 0~10
[Brake open FX 0~400
[Brake open RX 0~400
[Brake close 0~19
[Brake close 0~400
Parameter
name
Min/Max
range
Description
Sets Brake open dely time.
Sets FX frequency to open the brake
Sets RX frequency to open the brake
Sets delay time to close the brake
Sets frequency to close the brake
Factory
defaults
1.00 X
1.00 X
1.00 X
1.00 X
2.00 X
Adj.
during run
Drive Starvert iG5A Series
41
iG5A
Protective Functions
Protective functions
DescriptionsKeypad display
The drive turns off its output when the output current of the drive flows more than 200% of the drive rated
current.
The drive turns off its output when a ground fault occurs and the ground fault current is more than the internal
setting value of the drive.
The drive turns off its output when the output current of the drive flows more than the rated level (150% for 1
minute).
The drive turns off its output if the output current of the drive flows at 150% of the drive rated current for more
than the current limit time (1min).
The drive turns off its output if the heat sink overheats due to a damaged cooling fan or an alien substance in
the cooling fan by detecting the temperature of the heat sink.
The drive turns off its output when the one or more of the output (U, V, W) phase is open. The drive detects
the output current to check the phase loss of the output.
The drive turns off its output if the DC voltage of the main circuit increases higher than 400V when the motor
decelerates. This fault can also occur due to a surge voltage generated at the power supply system.
The drive turns off its output if the DC voltage is below 180V because insufficient torque or overheating of the
motor can occur when the input voltage of the drive drops.
The internal electronic thermal of the drive determines the overheating of the motor. If the motor is overloaded, the drive turns off
the output. The drive cannot protect the motor when driving a motor having more than 4 poles or multi motors.
Drive output is blocked when one of R, S, T is open or the electrolytic capacitor needs to be replaced.
Displayed when IGBT damage, output phase short, output phase ground fault or output phase open occurs.
Displayed when user-setting parameters fails to be entered into memory.
Displayed when an error occurs in the control circuitry of the drive.
Displayed when the drive cannot communicate with the keypad.
Displayed when the drive and the remote keypad do not communicate with each other.
It does not stop drive operation.
Displayed after the drive resets the keypad when
a keypad error occurs and this ....
Displayed when a fault condition occurs in the drive cooling fan.
Used for the emergency stop of the drive. The drive instantly turns off the output when the EST terminal is turned on.
Caution:
The drive starts to regular operation when turning off the EST terminal while FX or RX terminal is ON.
When multi-function input terminal (I20-I24) is set to 19
{External fault signal input A: (Normal Open Contact)}, the drive turns off the output.
When multi-function input terminal (I20-I24) is set to 19
{External fault signal input B: (Normal Close Contact)}, the drive turns off the output.
When drive operation is set via analog input (0-10V or 0-20mA input) or option (RS-485) and no signal is applied,
operation is done according to the method set in I62 (Operating method when the frequency reference is lost).
42
Fault Remedy
Overcurrent
Compact & Powerful Drive iG5A
RemedyKeypad displayCause
Caution: When an overcurrent fault occurs, operation must be started after the cause is removed
to avoid damage to IGBT inside the drive.
2
Accel/Decel time is too short compared to the GD
the load.
Load is greater than the drive rating.
Drive output is issued when the motor is free running.
Output short circuit or ground fault has occurred.
Mechanical brake of the motor is operating too fast.
→ Increase the Accel/Decel time.
of
→ Replace the drive with appropriate capacity.
→ Resume operation after stopping the motor or use
H22 (Speed search).
→ Check output wiring.
→ Check the mechanical brake.
Ground fault current
Drive overload
Overload trip
Heat sink overheat
Output Phase loss
Cooling fan fault
Over voltage
Low voltage
Electronic thermal
Ground fault has occurred at the output wiring of the drive.
The insulation of the motor is damaged due to heat.
Load is greater than the drive rating.
Torque boost scale is set too large.
Cooling system has faults.
An old cooling fan is not replaced with a new one.
Ambient temperature is too high.
Faulty contact of magnetic switch at output.
Faulty output wiring.
An alien substance is clogged in a ventilating slot.
Drive has been in use without changing a cooling fan.
2
Decel time is too short compared to the GD
Regenerative load is at the drive output.
Line voltage is too high.
Line voltage is low.
Load larger than line capacity is connected to line
(ex: welding machine, motor with high starting current
connected to the commercial line).
Faulty magnetic switch at the input side of the drive.
Motor has overheated.
Load is greater than drive rating.
ETH level is set too low.
Drive capacity is incorrectly selected.
Drive has been operated at low speed for too long.
of the load.
→ Check the wiring of the output terminal.
→ Replace the motor.
→ Upgrade the capacity of motor and drive or reduce
the load weight.
→ Reduce torque boost scale.
→ Check for alien substances clogged in the heat sink.
→ Replace the old cooling fan with a new one.
→ Keep ambient temperature under 50°C.
→ Make connection of magnetic switch
at output of the drive securely.
→ Check output wiring.
→ Check the ventilating slot and remove
the clogged substances.
→ Replace the cooling fan.
→ Increase the Decel time.
→ Use Dynamic Brake Unit.
→ Check whether line voltage exceeds its rating.
→ Check whether line voltage is below its rating.
→ Check the incoming AC line.
Adjust the line capacity corresponding to the load.
→ Change a magnetic switch.
→ Reduce load weight and operating duty.
→ Change drive with higher capacity.
→ Adjust ETH level to an appropriate level.
→ Select correct drive capacity.
→ Install a cooling fan with a separate power supply.
External fault A
contact input
External fault B
contact input
Operating method
when the frequency
command is lost
Remote keypad
communication error
The terminal set to “18 (External fault- A)" or
“19 (External fault-B)” in I20-I24 in I/O group is ON.
No frequency command is applied to V1 and I.
Communication error between drive
keypad and remote keypad.
- EEP: Parameter save error
- HWT: Hardware fault
- Err: Communication Error
- COM: Keypad error
→ Eliminate the cause of fault at circuit connected to
external fault terminal or cause of external fault input.
→ Check the wiring of V1 and I and frequency
reference level.
→ Check for connection of communication line and
connector.
→ Contact your LSIS sales distributor.
Drive Starvert iG5A Series
43
Safety Instructions
•
For your safety, please read user's manual thoroughly before operating.
•
Contact the nearest authorized service facility for examination, repair, or adjustment.
•
Please contact a qualified service technician when you need maintenance.
Do not disassemble or repair by yourself!
•
Any maintenance and inspection shall be performed by the personnel having expertise concerned.
HEAD OFFICE
■
LS Tower, 127, LS-ro, Dongan-gu, Anyang-si, Gyeonggi-do, Korea
■
Europe & Middle East
■
Africa
+82-2-2034-4967 / sjleeq@lsis.com
■
Asia Pacific +82-2-2034-4620 / mswoo@lsis.com
Overseas Subsidiaries
●
LSIS(Dalian) Co., Ltd._Dalian, China
No. 15, Liaohexi 3-Road, Economic and Technical Development Zone, Dalian 116600, China
Tel : 86-411-8730-7510 / Fax : 86-411-8730-7560
●
LSIS(Wuxi) Co., Ltd._Wuxi, China
No. 1, Lexing Road, Wuxi National High &New Tech Industrial Development Area, Wuxi214028, Jiangsu, P.T.China
Tel : 86-510-8534-6666-8005 / Fax : 86-510-8534-4078
●
LS Hukai Electric(Hubei) Co., Ltd._ Hubei, China
No. 100, Tanjiahe Road, Dianjun District, Yichang City, Hubei Province, 443004, China
Tel : 86-717-667-7339 / Fax : 86-717-667-7559
●
LS-VINA Industrial Systems Co., Ltd._Hanoi, Vietnam
32nd Floor, International Corporate City, No.3000 NorthZhongshan Road, Putuo District, Shanghai, China, 200063
Tel : 86-21-5237-9977 / Fax : 86-21-5237-7189
●
LSIS Beijing Office, China
Room 2306, Building B Landgent Center, No.24 Middle Road, East 3rd Ring Road, Chaoyang District, Beijing, P.R. China
Tel : 86-10-5761-3127 / Fax : 86-10-5761-3128
●
LSIS Guangzhou Office, China
Room 1818-1820, Xinyuan Building,NO.898 Tianhe North Road, Tianhe District, Guangzhou, P.R China
Tel : 86-20-8326-6784 / Fax : 86-20-8326-6287
●
LSIS Qingdao Office, China
Room 2001, Galaxy Building, 29 ShanDong Road, ShiNan District, QingDao, ShanDong, P.R. China
Tel : 86-532-8501-6058 / Fax : 86-532-8501-6057
●
LSIS Chengdu Office, China
Room1710, 17/F Huamin Empire Plaza, NO.1 Fuxin Road, Chengdu, P.R. China
Tel : 86-28-8670-3200 / Fax : 86-28-8670-3203
●
LSIS ShenYang Office, China
Room 803, Hongyuan Building, 52 South Nanjing Road, Heping District, Shenyang, P.R. China
Tel : 86-24-2321-9050 / Fax : 86-24-8386-7210
●
LSIS Jinan Office, China
Room 317, Chuangzhan Center, No. 201, Shanda Road, Lixia District, Jinan, Shandong, P. R. China
Tel : 86-531-8699-7826 / Fax : 86-531-8697-7628
●
LSIS Co., Ltd. Tokyo Office, Japan
Tokyo Club Building 13F, 2-6, Kasumigaseki 3-chome, Chiyoda-ku, Tokyo, 100-0013
Tel : 81-3-6268-8241 / Fax : 81-3-6268-8240
●
LSIS Co., Ltd. Rep. Office, Vietnam
Gema Dept Tower 18F, 6 Le Thanh Ton, District 1, HCM, Vietnam
Tel : 84-8-3823-7890
●
LSIS Detroit Office, U.S.A.
5700 Crooks Rd, Suite 211, Troy, MI 48098, USA
Tel : 1-248-792-2637~8 / Fax : 1-248-792-2642
●
LSIS Co., Ltd. India Office, India
109 First Floor, Park Central, Sector-30, Gurgaon- 122 002, Haryana, India
Tel : 91-1244-930-077 / Fax : 91-1244-930-066
●
LSIS Moscow Office, Russia
123610, Krasnopresnenskaya, nab., 12, building 1, office №1005, Moscow, Russia
Tel : 7-495-258-1466/1467 / Fax : 7-495-258-1466/1467
●
LSIS U.K. Office, United Kingdom
G17 Bedford I-Lab, Stannard Way, Priory Business Park, Bedford, MK44 3RZ, U.K.
Tel : 44-012-3483-4774 / Fax : 44-012-3483-4775
2014. 10
STARVERT iG5A (E) 2005. 05/(22) 2014. 06 Printed in Korea Pacomkorea