LSI SCSI 320-2 User Manual

Quick Hardware Setup Guide
LSI Logic MegaRAID® SCSI 320-2 Controller
Thank you for purchasing the MegaRAID SCSI 320-2 Controller. Please take a few minutes to read this Quick Hardware Setup Guide before you install the MegaRAID controller. If you need more information about any topic covered in this guide, please refer to the other documents on your Driver and Documentation CD.
Contents of Driver and Documentation CD
The Driver and Documentation CD is packaged with the MegaRAID SCSI 320-2 Controller. The CD contains utility programs, device drivers for various operating systems, and the following documentation:
· MegaRAID SCSI 320-2 Hardware Guide
· MegaRAID Configuration Software Guide
· MegaRAID Operating System Driver Installation Guide
· Software license agreement and warranty registration card
Technical Support
If you need help installing, configuring, or running the MegaRAID SCSI 320-2 Controller, contact LSI Logic Technical Support:
Phone Support: 678-728-1250 Web Sit e: http://megaraid.lsilogic.com/support/index.html Email: MegaRAIDsupport@lsil.com
MegaRAID Controller Installation
Caution: Make a backup of your data before you change your system
configuration. Otherwise you may lose data.
Follow these steps to install the MegaRAID SCSI 320-2 Controller. Each step is explained more fully in the following text:
Step Action
8 Set SCSI termination.
9 Replace the computer cover and turn the power on. 10 Run the MegaRAID BIOS Configuration Utility. 11 Install the operating system driver.
Step 1: Unpack MegaRAID Controller
Unpack and install the MegaRAID SCSI 320-2 Controller in a static-free environment. Remove the MegaRAID controller from the anti-static bag and inspect it for damage. If it appears to be damaged, or if the Driver and Documentation CD is missing, contact LSI Logic or your MegaRAID OEM support representative.
Step 2: Prepare Computer
Turn off the computer and remove the power cord from th e back of the power supply. Remove the cover from the chassis. Make sure the computer is
disconnected from the power and from any networks before installing the controller card.
Step 3: Ch eck MegaRAID C ontroller Jumpe rs
Make sure the jumper settings on the MegaRAID controller are correct. The jumpers are set at the factory, and you probably do not need to change them. The following table lists the MegaRAID controller jumpers that you should check:
Jumper Description Type
J2 SCSI activity indicator: this can be connected to the
hard disk LED on the computer enclosure to display SCSI bus activity.
J3 Write Pending indicator: this can be connected to
an LED on the computer enclosure. The LED will be lit when data in the cache has not yet been written to the storage device.
J4, J5 SC SI Termination Control for SCSI Channels 1 (J5)
and 0 (J4): Leave at the default setting (jumper on pins 1 and 2) to allow the MegaRAID controller to automatically set its own SCSI termination.
J10 Batter y pack connector: this connector is used to
connect the backup battery pack.
J16 Enables or disables the MegaRAID onboard BIOS.
Leave the BIOS enabled (no jumper).
J17,
TermPWR Enable for SCSI Channels 0 (J17) and 1
J18
(J18): Leave at the default setting (jumper on pins 1 and 2) to allow the PCI bus to provide termination power on the two SCSI channels.
The following diagram shows the location of these jumpers and of the various connectors on the MegaRAID SCSI 320-2 Controller.
4-pin header
2-pin header
3-pin headers
3-pin header
2-pin header
2-pin headers
Step Action
1 Unpack the MegaRAID SCSI 320-2 Controller. 2 Turn off the computer, remove the power cord, and remove the cover. 3 Check the MegaRAID controller jumper settings. 4 Install the battery backup pack. 5 Install the MegaRAID controller. 6 Connect the SCSI devices to the MegaRAID controller. 7 Set the target IDs for the SCSI devices.
®
Document Part Number: DB11-000013-00 September 2002
Quick Hardware Setup Guide
J4
External
Very-High
Density
SCSI
Connectors
J5
Channel 0
Channel 0Channel 1
J17
J18
Internal High-Density
SCSI Connectors
DIMM Socket
Channel 1
J2 J3
J10
J16
Step 4: Install Battery Backup Pack
The battery backup pack on the MegaRAID controller provides 72 hours of data retention in the event of a power failure. The MegaRAID SCSI 320-2 Controller normally includes a battery backup pack as a standard feature.
If you need to install a battery pack on the MegaRAID controller, you can screw the battery to the board through the backside of the board, using the three holes in the board. Connect the three wires from the battery pack to J10, the battery pack connector. The new battery pack must then be configured with the MegaRAID BIOS setup program. See the MegaRAID SCSI 320-2 Hardware Guide for more information.
Step 5: Install MegaRAID SCSI 320-2 Controller
Install the MegaRAID SCSI 320-2 Controller in a 3.3 V or 5 V PCI slot, as shown below. Press down gently, but firmly, to make sure that the card is properly seated in the slot. The bottom edge of the controller card must be flush with the slot. Then attach the MegaRAID controller to the computer chassis with the bracket screw.
Bracket Screw
Step 6: Connect SCSI Devices to MegaRAID Controller
Connect SCSI devices to the internal high-density 68-pin SCSI connectors and/or the external very high-density 68-pin SCSI connectors. To achieve maximum data throughput, use only Ultra320 SCSI devices. The MegaRAID SCSI 320-2 Controller supports up to 15 Ultra320 devices per channel at a maximum SCSI bus cable length of 12 m. You can also connect Ultra160 and Ultra2 SCSI devices. The MegaRAID SCSI 320-2 Hardware Guide lists the maximum number of devices and maximum cable length for each kind of SCSI device.
Disable SCSI termination on all devices that are not connected at the end of the SCSI bus. Use only high-quality ribbon SCSI cables for internal devices and high-quality round SCSI cables for external devices. If you are connecting both SCSI disk drives and other kinds of SCSI devices such as CD-ROM drives, we recommend that you connect the disk drives on one SCSI channel and the other devices on the other channel.
Step 7: Set Target IDs for SCSI Devices
Each connected SCSI device on a channel must have a unique Target ID (TID), ranging from 0 to 15 for 16-bit devices. The MegaRAID SCSI 320-2 Controller is automatically assigned TID 7, which has the highest priority. Check all SCSI devices to make sure that no two devices on the same channel are set to the same TID. Change the TIDs as needed. See the SCSI device documentation if you are not sure how to do this.
The MegaR AID SCSI 320-2 Hardware Guide shows examples of how to assign SCSI IDs to various combinations of devices.
Step 8: Set SCSI Termination
The SCSI bus, which consists of connected SCS I cables and S CSI devices, is an electrical transmission line that must be terminated properly to minimize signal reflections and prevent data loss. Disk enclosures normally handle termination for the SCSI devices in the enclosure. Refer to your enclosure documentation for more information.
SCSI termination must be set at each end of each SCSI bus (channel), as shown below. In this example, only internal SCSI devices are connected to one channel of the MegaRAID controller. The MegaRAID controller automatically terminates its end of the SCSI bus if only internal devices or only external devices are connected to that channel. It automatically disables termination if both internal and external devices are connected to that channel, because the MegaRAID controller is then in the “middle” of the bus.
32-Bit Slots (3.3 V)
64-Bit Slots (5 V)
Termination on Controller
Enabled
SCSI Devices
(Termination Disabled on Both)
For a disk array, set SCSI bus termination so that removing or adding a SCSI device does not disturb termination. To do this, connect the MegaRAID SCSI 320-2 Controller to one end of the SCSI cable and connect a SCSI terminator module at the other end of the cable. Attach SCSI devices to the connectors between the two ends, and disable termination on them.
The following example shows an external drive enclosure with seven SCSI drives. Termination is enabled at the end of the cable nearest the “last” SCSI drive, which is assigned SCSI ID6 (TID 6).
Pag e 2
SCSI Terminator
Loading...