LSI MegaRAID SATA 8308ELP Quick Installation Manual

Page 1
®
Thank you for purchasing the MegaRAID® SATA (Serial Attached SCSI/Serial ATA II) 8308ELP (PCI Express low­profile) RAID Controller. Please take a few minutes to read this quick installation guide before you install the controller.
PCI Express x4 or greater slot.
Note: SATA II is the only type of SATA supported by the
8308ELP.
You can use the intelligent Battery Backup Unit 01 (LSIiBBU01) with the 8308ELP.
MegaRAID SATA 8308ELP RAID CONTROLLER INSTALLATION
Step 1 Unpack the MegaRAID SATA 8308ELP RAID
Controller
Unpack the controller in a static-free environment. Remove it from the antistatic bag and inspect it for damage.
If the controller appears to be damaged contact LSI Logic or your MegaRAID OEM support representative.
Step 2 Prepare the Computer
Turn off the computer and unplug the power cord(s) from the back of the power supply. Remove the cover from the computer.
Step 3 Review the Jumpers and Connectors
Figure 1 shows the location of the jumpers and
connectors on the 8308ELP. The jumpers are set at the factory and you usually do not need to change them.
Figure 1 MegaRAID SATA 8308ELP RAID
Controller Card Layout
Note: J11, the battery backup connector, is located on
the back side of the 8308ELP.
Make a backup of your data before you change your system configuration. Otherwise, you may lose data.
!
CAUTION
Make sure the computer is disconnected from the power and from any networks before installing the controller.
!
CAUTION
J3
J9
Port
J10
P1
U13
Por
t
J8
J1
J4
J5
J6
J7
J2
U14
0–3
4–7
J11
Connector Located
on Back of Board
MegaRAID
®
SATA 8308ELP
RAID Controller
Quick Installation Guide
Page 2
2 of 3
The following table describes the jumpers and connectors on the controller.
Step 4 Install the MegaRAID SATA 8308ELP RAID
Controller
Insert the 8308ELP in a PCI-E slot on the mainboard, as shown in Figure 2. Press down gently but firmly to seat the card properly in the slot. Secure the 8308ELP to the computer chassis with the bracket locking.
Note: Refer to your mainboard guide for information
about the PCI-E slot.
Figure 2 Installing the MegaRAID SATA 8308ELP
RAID Controller
Step 5 Configure and Install SATA II Devices
Configure the SATA II devices and install them in the host system computer case.
Refer to the documentation for the devices for any pre-installation configuration requirements.
Step 6 Connect the MegaRAID SATA 8308ELP RAID
Controller to the SATA II Devices
Use SAS cables to connect the 8308ELP to SATA II devices. Refer to Figure 1 to view connector locations on the controller.
Jumper/ Connector Type Description
J1
IPMI-style I2C Debug header (Intelligent Plat­form Management Interface)
3-pin connector. Used for diagnostic purposes.
J2 Individual Activity
LED header for all eight ports
16-pin (8x2) header. Provides LED interface individually
to eight SATA ports. The LED indi­cates activity on particular ports.
J3 Debugger 2-pin jumper.
Used for diagnostic purposes.
J4 Serial header for
debug use
4-pin header. Used for diagnostic purposes.
The serial port is not RS232 volt­age level compliant.
J5 Mode Select 2-pin connector.
If the firmware flashed onto the board is corrupted, you need to jumper J5 (this holds the CPU core in reset), so you can flash the firm­ware. Remove the jumper after you flash the new firmware.
No jumper: This is the setting dur­ing normal operation (Mode 3). This is the default.
Jumper: This holds the CPU core in reset (Mode 0).
Note: The card does not function as a RAID controller if this jumper is mounted.
J6 IPMI-style SMBus
(System Manage­ment) /I
2
C header
3-pin connector. Provides enclosure management
support.
J7 Cache Write
Pending LED
2-pin header. Connector for enclosure LED.
Provides a signal that indicates when the on-board cache contains data and a write from the cache to the hard drives is pending. Optional.
J8 LED Drive
Fault Connector Interface
16-pin (8x2) connector. Provides LED interface individually
to eight SATA ports. The LED indi­cates a drive fault on particular ports.
J9 SATA 8308ELP
Ports
Ports 4–7. The ports connect the cables from
the adapter to SAS or SATA II physical drives, or a port multiplier.
J10 SATA 8308ELP
Ports
Ports 0–3. The ports connect the cables from
the adapter to SAS or SATA II physical drives, or a port multiplier.
J11 Battery Backup
Connector (located on the back side of the RAID controller)
20-pin connector. Provides interface to the remote
battery pack.
32-bit Slots
64-bit Slots
(3.3 V)
(3.3 V)
Edge of
Mainboard
Bracket Screw
Press Here
Press Here
Page 3
PN: 80-00111-01 Rev. A DB11-000071-01, Version 2.0, February 2006 Find a list of LSI Logic Corporation’s U.S. distributors, international distributors,
sales offices, and design resource centers on the LSI Logic web site at:
http://www.lsilogic.com/contacts/index.html
LSI Logic, the LSI Logic logo design, and MegaRAID are registered trademarks of LSI Logic Corporation. All other brand and product names may be trademarks of their respective companies.
®
Copyright © 2005-2006 by LSI Logic Corporation. All rights reserved. LSI Logic products are not intended for use in life-support appliances, devices, or
systems. Use of any LSI Logic product in such applications without written consent of the appropriate LSI Logic officer is prohibited.
Purchase of I2C components of LSI Logic Corporation, or one of its sublicensed Associated Companies, conveys a license under the Philips I2C Patent Rights to use these components in an I
2
C system, provided that the system conforms to the
I
2
C standard Specification as defined by Philips.
LSI Logic Corporation reserves the right to make changes to any products and services herein at any time without notice. LSI Logic does not assume any responsibility or liability arising out of the application or use of any product or service described herein, except as expressly agreed to in writing by LSI Logic; nor does the purchase, lease, or use of a product or service from LSI Logic convey a license under any patent rights, copyrights, trademark rights, or any other of the intellectual property rights of LSI Logic or of third parties.
Step 7 Power-Up the Computer
Replace the computer cover and reconnect the power cord(s). Turn on power to the computer. Ensure that the SATA II devices are powered up before or at the same time as the host computer. If the computer is powered up before the devices, the devices might not be recognized.
During boot, a MegaRAID BIOS message similar to the following displays:
LSI LOGIC MEGARAID BIOS VERSION xxxx [date]
Copyright(c) 2005, LSI Logic Corp.
HA-1 (Bus x Dev y) LSI MegaRAID SATA 8308ELP PCI-E
Standard FW xxxx DRAM=xxx MB(SDRAM)
The firmware takes several seconds to initialize. During this time the adapter scans the ports.
Step 8 Run the WebBIOS Configuration Utility
Run the WebBIOS Configuration Utility to configure the physical arrays and logical drives. When the message Press <Ctrl><H> for WebBIOS displays on the screen, press CTRL+H immediately to run the utility.
Note: Refer to the MegaRAID SAS Software User’s
Guide for detailed steps on configuring physical
arrays and logical drives.
Step 9 Install the Operating System Driver
The 8308ELP can operate under various operating systems. To operate under these operating systems, you must install software drivers.
Refer to the MegaRAID SAS Device Driver Installation User’s Guide for details on installing the driver. Be sure to use the latest Service Packs provided by the operating system manufacturer and review the readme file that accompanies the driver.
SUPPORTED RAID LEVELS
The 8308ELP supports disk arrays using the following RAID levels:
RAID 0 (Data striping): Data is striped across all disks
in the array, enabling very fast data throughput. There is no data redundancy. All data is lost if any disk fails.
RAID 1 (Disk mirroring): Data is written simultaneously
to two disks, providing complete data redundancy if one disk fails. The maximum array capacity is equal to the available size of the smaller of the two hard drives.
RAID 5 (Disk striping with distributed parity): Data is
striped across all disks in the array. Part of the capacity of each disk stores parity information that reconstructs data if a disk fails. Provides good data throughput for applications with high read request rates.
RAID 10 (RAID 1 and RAID 0 in spanned arrays): Uses
mirrored pairs of disks to provide complete data redundancy. Provides high data throughput rates.
RAID 50 (RAID 5 and RAID 0 in spanned arrays): Uses
both parity and disk striping across multiple disks to provide complete data redundancy. Provides high data throughput rates.
TECHNICAL SUPPORT
For assistance installing, configuring, or running the 8308ELP, contact Technical Support:
Web Site:
http://www.fujitsu-siemens.com/support/
Phone Support:
For your country’s support phone number please refer to:
http://www.fujitsu-siemens.com/support/helpdesk.html
Page 4
Information on this document
On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu­ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So­lutions.
This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.
Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions.
Contact and support addresses will now be offered by Fujitsu Technology So­lutions and have the format …@ts.fujitsu.com.
The Internet pages of Fujitsu Technology Solutions are available at
http://ts.fujitsu.com/...
and the user documentation at http://manuals.ts.fujits u.com. Copyright Fujitsu Technology Solutions, 2009
Hinweise zum vorliegenden Dokument
Zum 1. April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen. Diese neue Tochtergesellschaft von Fujitsu trägt seit­dem den Namen Fujitsu Technology Solutions.
Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion.
Bitte beachten Sie, dass alle Firmenbezüge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions übergegangen sind.
Kontakt- und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Form …@ts.fujitsu.com.
Die Internetseiten von Fujitsu Technology Solutions finden Sie unter
http://de.ts.fujitsu.com/..., und unter http://manuals.ts.fujitsu.com finden Sie die
Benutzerdokumentation. Copyright Fujitsu Technology Solutions, 2009
Loading...