LumeLEX 2030/2031 SERIES INSTALLATION INSTRUCTIONS
Important
Warning
Product Overview
Purpose of This Sheet
THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.
To prevent electrical shock, turn off the power during installation or maintenance.
To reduce the risk of fire, keep away from combustible materials.
The LumeLEX 2030/2031 Series is a clean, elegant stem mounted LED spotlight with a discreetly hidden driver, making it appear no different than a traditional halogen source.
With independent ratings of 97CRI, the LumeLEX 2030/2031 series, based on the latest in Remote Corrected Cold Phosphor Technology by Xicato, has the highest Color Rendering Index of any LED on the market today, producing the most consistent, highest quality white light and maintaining extremely tight color control (within 2 MacAdam ellipses, vs. the NEMA standard of 7). The LumeLEX 2030/2031 series also features a snap-out cross baffle and accessory cartridge which accepts up to two optical accessories, size ‘AAA’.
See the fixture label for voltage and wattage input.
Please consult our Product Catalog or web site for available accessories.
We recommend that you first install the reflector and any accessories before installing the fixture.
The purpose of this sheet is to provide step-by-step instructions to help you:
Install the fixture with any of the following: -00E fitting on an LSI track, -BUSE fitting on an LSI
Busway, -5AE canopy.
Install accessory filters and reflectors Aim the self-locking and wrench-locking fixture Clean the optical surfaces and reflector
LumeLEX 2030 Series Spotlight
www.LightingServicesInc.com Page 1 of 6 IS-0139_A
Page 2
Changing or Installing the Reflector
Before Changing Reflector: To maintain the
fixture’s current orientation, change the reflector with the fixture in its location. If the orientation does change, refer to the “Aiming the Fixture”
section of this sheet. Refer to our Product Catalog
or web site for reflector options.
Follow steps 1, 2, 4, and 5 if you are installing the reflector for the first time.
STEP ACTION
1 Turn off all power to the fixture,
including the fixture switch on the fitting, and let the LED cool.
WARNING: LED and fixture may be hot.
2 Remove the cylinder housing by
grasping the fitting stem in one hand and the cylinder housing in the other. Pull in opposite directions while rocking the housing gently side to
side. (Fig. 1).
3 Remove the reflector by turning it
counter-clockwise, then pulling it out
of the fixture. (Fig. 2).
4 Insert the new reflector by lining up
the three tabs with the notches in the LED Adapter Ring, and rotating clockwise until it is secured in
place.(Fig 3)
Figure 1. Cylinder housing loosened and notches aligned (arrow). Pull off to expose lamp, or push onto stem to close and secure housing.
Figure 2. Rotate reflector counter-clockwise to remove it.
5 Close the fixture front by replacing the
cylinder housing. Align the stem notch to the cylinder housing notch and push the cylinder housing onto the stem notch until it clicks into place
and is secured. (Fig. 1).
6 Restore power.
WARNING: Do not look directly at the lit LED.
www.LightingServicesInc.com Page 2 of 6 IS-0139_A
Figure 3. The three notches in the LED Adapter Ring. Align the reflector tabs with these notches and rotate clockwise to secure in it.
Page 3
r
r
w
Installing the Fixture with the
-00E Fitting on an LSI Track or a
-BUSE fitting on an LSI Busway
FOR USE WITH LSI 3, 4, 5, 6, 8, AND 9 SERIES TRACK AND LSI 20 SERIES BUSWAY SYSTEMS ONLY.
INSTALLATION INSTRUCTIONS: The track or busway
must already be installed according to code requirements. When installing or using this track or busway system, basic safety precautions should always be followed, including the
following:
Read all instructions. Do not install any part of a track or busway system less
than 5 feet above the floor (8 feet for 277V).
Do not install any fixture closer than 6 inches from any
curtain or similar combustible material.
STEP ACTION
1 Flip the fitting switch off and open the fitting handle
(Fig. 4).
2
Are you using a one-circuit or two-circuit system?
If one-circuit, make sure the brass contacts that
protrude from the side of the fitting face the copper busbars inside the track or busway.
If two-circuit, inserting the fitting in one direction
connects to circuit one. Removing and reversing the direction of the fitting connects to circuit two.
3 Insert the fitting straight up into the track or busway
until fully seated (Fig. 5).
Figure 4. Fitting with switch OFF and handle OPEN.
Figure 5. Inserted fitting
Installing the Fixture with a 5AE Canopy
4
Close the handle and flip the fitting switch on (Fig 6).
WARNING: Do not look directly at lit LED.
5 To remove the fitting, hold the fixture in place, flip
the fitting switch off, open the handle, and pull the fitting straight off the track or busway.
Before Installing: Consult the code requirements for fixture
mounting. Mount the fixture to a ceiling constructed of non­combustible material, away from any flammable materials.
STEP ACTION
1 Turn off all power to the fixture mount.
2 Unscrew the 2 supplied canopy mounting screws,
and remove the crossbar from the canopy (Fig. 7).
3 Attach the canopy crossbar (Fig. 8) to a ceiling
junction box with 2 screws (supplied by others).
4 Fasten the power wires (Fig. 8) from the junction
box to the LED driver. Secure the driver inside the junction box with tape supplied, taking care not to
pinch or damage any wires. (Fig. 8)
Note: Connect green to ground, black to the circuit line, and white to neutral.
5 Attach the canopy to the ceiling with the 2 supplied
canopy mounting screws.
Figure 6. Switch ON, fitting handle closed
Figure 7. Fixture mounted on the 5AE Canopy
Crossba
Transformer/ Drive
Ground
Figure 8. Junction Box, crossbar, ground screw (green) and a transformer/driver secured.
Scre
www.LightingServicesInc.com Page 3 of 6 IS-0139_A
Page 4
Installing Accessory Filters and Reflectors
Before Installing:
removable accessory cartridge that holds size-AAA LSI filters and accessories, as well as other reflectors. The LumeLEX 2030/2031 package includes accessory cartridges and a
reflector. Consult our Product Catalog or web site for
accessory recommendations.
STEP ACTION
The LumeLEX 2030/2031 has a
1 Turn off all power to the fixture, including
the fixture switch on the fitting, and let the lamp cool.
WARNING: LED and fixture may be hot.
2 Remove the cross-baffle cartridge
assembly by pulling it out of the cylinder
housing (Fig. 9) .
3 Insert any double combination of size-AAA
filters and accessories into the Accessory
Cartridge Clips (Fig. 10)(LX-2030) or (Fig 11)(LX-2031).
Alternatively, the Accessory Cartridge will accept a single or combination of size-AAA gels, which are secured with the included
Backer Ring (Fig. 10). Insert the gel into
the Accessory Cartridge, taking care to orient non-symmetrical gels properly (refer to instruction sheet for LX2031 for specific gel orientation) and having the dull side facing in towards the LED. Secure the gels by inserting the backer ring on top and seating it firmly in the cartridge.
4 Reinsert Accessory Cartridge into the
cylinder housing by pushing in the Retension Tabs on the sides of the
cartridge (Fig. 10).
Ensure that the cartridge is pushed all the way in, with the Cross-Baffle being flush or
below the front edge of the housing (Fig.9).
For LX-2031, ensure that the top of the Kicker Reflector Bracket is aligned with the slot in the LX-2031 front. Push until the top of the Kicker Reflector Bracket is bottomed
out in the slot. (Fig 11)
Figure 9. Remove Cross-Baffle cartridge assembly by pulling it out of the cylinder housing. Cross-Baffle should be flush or below front edge of housing when installed.
Accessory Clips
Backer Ring
Retension Tabs
Figure 10(LX-2030). Accessory Clips, Retension Tabs, Backer Ring.
Accessory Clips
Slot
Top of Bracket
5 Restore power.
WARNING: Do not look directly at the lit
www.LightingServicesInc.com Page 4 of 6 IS-0139_A
LED.
Kicker Reflector Bracket
Figure 11(LX-2031). Accessory Clips, Tabs, Kicker Reflector Bracket
Page 5
e
Aiming the Self­Locking and Wrench­Locking Fixtures
Before Aiming: For self-locking, you do not need
an external locking device to set the horizontal and vertical focus. For wrench locking, use the supplied Allen key (3/32 inches) to set and lock the horizontal and vertical focus.
STEP ACTION
1 Turn off all power to the fixture,
including the fixture switch on the fitting, and let the lamp cool.
WARNING: LED and fixture may be hot.
2 Do you want to aim the fixture
horizontally or vertically?
For horizontal aiming, hold the
lamp housing and turn it left or right until you achieve your desired
orientation (Fig. 12).
For vertical aiming, hold the lamp
housing and angle it up and down until you achieve your desired
orientation (Fig. 13).
For wrench locking: After aiming,
insert the Allen key into the horizontal or vertical focus lock
(Fig. 14), and turn it clockwise to
tighten.
Note: Allen key is supplied for track
and busway fixtures. It is stored in
fitting handle (Fig. 15).
Figure 12. Turn fixture left or right to set the horizontal focus.
Figure 13. Angle fixture up or down to set the vertical focus.
3 Restore power.
WARNING: Do not look directly at the lit LED.
Pull to remove
Push to stor
Figure 14. Horizontal focus lock (L). Vertical focus lock (R).
Figure 15. Allen key storage in fitting.
Push in to secure the key.
www.LightingServicesInc.com Page 5 of 6 IS-0139_A
Page 6
Important
Cleaning the Reflector
CLEANING INSTRUCTIONS for
LumeLEX 2000 REFLECTORS
FOLLOW THESE INSTRUCTIONS SO TO PREVENT DAMAGE TO YOUR REFLECTOR. NOT CLEANING THE REFLECTOR CORRECTLY CAN REDUCE THE EFFICIENCY OF THE OPTICAL SURFACE. DO NOT TOUCH THE SURFACE OF THE REFLECTOR WITH YOUR BARE SKIN, AS HUMAN SKIN OIL WILL DEGRADE THE OPTICAL SURFACE.
INSTRUCTIONS: Follow instructions from the specific
fixture and reflector for removal and assembly of the reflector to that fixture. Wear blue nitrile gloves during this process to ensure not to touch the optical surface of the reflector with your bare skin.
MATERIALS REQUIRED:
De-ionized water
Blue Nitrile Gloves
Dish soap (such as Dawn
Can of clean compressed air OR Air Bulb (aka suction bulb)
Lens Tissue (such as Kemwipes
®
) OR ● Isopropyl Alcohol
®
) OR Terry Cloth
STEP ACTION
1
2 Using either a can of clean compressed
3 Apply a generous amount of either
4 While wearing nitrile gloves, gently
5 Allow optic to dry prior to reinstalling
Remove the reflector from the fixture
air or a bulb, blow clean air across to remove any surface dust or debris.
De-ionized water combined with a small amount of dish soap, or Isopropyl Alcohol, to a lens tissue or terry cloth.
clean the inside of the reflector with the
wet lens tissue or terry cloth.
onto the fixture.
www.LightingServicesInc.com Page 6 of 6 IS-0139_A
Loading...