LSI BPM Installation Instructions Manual

Important
THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.
Warning
This product must be installed in accordance with National Electrical Codes and all other local codes by a person familiar with the construction and operation of the product and the hazards involved.
To prevent electrical shock, turn off the power during installation or maintenance. To reduce the risk of fire, keep away from combustible materials.
Product Overview
Congratulations on your purchase of LSI’s BPM series beam projector! This innovative design will afford you high-end LED based performance coupled with simplistic aiming, image projection, and focusing. Due to our stringent optical train design, you will find your projections to be sharper than any other competitor’s products.
The innovative optical train coupled with Cree’s High Density LED Array allows the BPM to outperform equivalent Halogen projectors while providing a fixture that is efficient, cool to the touch, and provides the superior color control available only to LED fixtures.
See the fixture label for voltage and wattage input.
Please consult our Product Catalog or web site for available accessories.
We recommend that you first install the lens train and any gobos before installing the fixture.
BPM Series Beam Projector
Purpose of This Sheet
The purpose of this sheet is to provide step-by-step instructions to help you:
Install alternate lens trains, gobos, and accessory gels. Install the fixture with any of the following: -00 fitting on an LSI track, -BUS fitting on an LSI
Busway, 5A canopy, -2G universal flange fitting, or -3G C-Clamp fitting.
Aim the self-locking and wrench-locking fixture. Service the 50,000 hour LED driver.
Dimming
BPM SERIES INSTALLATION INSTRUCTIONS
www.LightingServicesInc.com Page 1 of 8 IS-0201_A
The BPM is fully dimmable using compatible various dimmers and control schemes.  Please review dimming application guide for detailed information and a list of compatible
dimmers.
Accessory Cartridge Overview
Installing Patterns
Changing Orientation
The BPM series fixture contains an accessory cartridge capable of holding industry standard “E size (not ETC “D” size) Gobo’s. The BPM has been designed to accept any metal or glass pattern or dichroic color filters sized from 1.102” (28mm) to
1.476” (37.5mm) overall diameter, with a maximum image diameter of 1.102” (28mm) and a maximum edge thickness of 0.150 (3.8mm). The fixture also comes with Wide (20°-30°) and Narrow (30° - 55°) lens assemblies. Spread Gels and Screens should be placed at the front of the fixture to avoid imaging the media.
STEP
ACTION
1
Remove accessory cartridge by squeezing the tabs together and pulling the cartridge out (Fig. 1).
2
Remove the locking clip by sliding it out of the cartridge (Fig. 2).
3
Insert the pattern and/or color filter under the ring, making sure it is centered. Thicker media such as glass can be accommodated by inverting the locking clip (Fig. 3).
4
Replace the locking clip by aligning the tabs with the slots and inserting until tight. Firmly push cartridge back into the fixture until it is fully seated and flush.
STEP
ACTION
1
Loosen the image rotation thumb screw on the top of the fixture (Fig.4).
2
Turn the fixture on and spin optical assembly until the image is in the required orientation.
3
Lock the rotation locking thumb screw. No tools are required; hand tight only to avoid damage (Fig.4).
Figure 1. Remove accessory cartridge by squeezing the tabs.
Figure 2. Remove the locking ring by pulling it out of the holder. Replace and press in until the click to lock.
Figure 3. Reverse the locking clip to accommodate thicker media.
Figure 4. Loosen image rotation locking thumb screw to adjust image orientation. Tighten to lock.
www.LightingServicesInc.com Page 2 of 8 IS-0201_A
Changing Lenses
Image Enhancing Ring / Front Gel Holder Overview
Installing Media in the Front Gate
STEP
ACTION
1
Use the included allen wrench to remove the locking set screw. (Fig.5).
2
Rotate the lens assembly to align the take-down notches. The lens will come free.
3
To replace the lens, align the shoulder screws and take-down notch. Rotate the lens train clockwise until it seats fully. Tighten the locking set screw to secure in place.
The BPM allows for additional media to be discreetly placed at the front gate of the fixture. Spread gels and screens should be attached to the front of the fixture to ensure that the texture of the media does not interfere with the projected image.
STEP
ACTION
1
Grasp the front of the lens train using the finger notches.
2
Pull to reveal the media slot.
3
Insert the media. Holder will accommodate several layers of gels and screens. (Fig. 6).
4
Release the front of the lens train and allow the spring action to hold the media in place (Fig. 7).
Figure 5. Remove the locking set screw and rotate the lens train to remove. Align take­down notches to attach/remove the lens.
Figure 5. Grasp the front of the lens train and pull to reveal the media slot.
Figure 6. Insert media and
release the front of the lens,
allowing the spring action hold
media in place.
www.LightingServicesInc.com Page 3 of 8 IS-0201_A