Product Brief
K E Y F E A T U R E S
n
Scalable to 128 SAS and/or
Serial ATA devices
n
PCI Express x8 host interface
n
Conguration exibility with four
conguration options
– 8 internal ports
– 8 external ports
– 4 internal/four external ports
– 4 internal ports
n
SAS, SATA, and SATA II features, including
3Gb/s and NCQ
n
512MB DDR2 533 ECC protected memory
n
Simultaneous double parity generation
to maximize RAID 6 performance
n
StorSwitch™ 8th generation non-blocking
switch fabric for maximum controller
throughput
n
StreamFusion optimizes I/O accesses to
maximize application performance under
heavy workloads
n
StorSave BBU with write journaling
optimizes data protection and
performance; remote battery support
n
Low-prole form factor
n
RAID levels 0, 1, 5, 6, 10, 50, and
Single Disk
Disk #1
Disk #2
Disk #3
P1 Parity
Q1 Parity
Block 1
P2 Parity
Block 8
Block 11
Q2 Parity
P3 Parity
Block 12
Block 4
Block 7
Block 10
Striped Data with Distributed Double Parity —
RAID 6: Two sets of parity data, P + Q, are
striped across disks. RAID 6 safeguards against
data loss during rebuild mode by allowing up
to two consecutive drive failures for maximum
fault tolerance.
Disk #4
Block 2
Block 5
Q3 Parity
P4 Parity
Disk #5
Block 3
Block 6
Block 9
Q4 Parity
RAID 6
3ware® 9690SA
High-Performance Serial Attached SCSI (SAS) RAID Controller
The LSI 3ware 9690SA SAS/SATA hardware RAID controllers deliver industry-leading RAID 6 and RAID 5 performance, expanded scalability, robust
fault tolerance, and multi-terabyte capacities. A PCI Express host interface,
StorSwitch™ architecture and sophisticated SAS and SATA II features drive
this unrivaled performance.
It’s Time for SAS
3ware pioneered the way for SATA and now
capitalizes on time-proven serial storage
expertise to take users from parallel SCSI to
SAS. The 9690SA seizes the moment to enter
the market just as SAS hard drives, expanders
and backplanes are more widely available and
as enterprise infrastructures align to realize the
potential of Serial Attached SCSI. As SAS makes
inroads into the SCSI market, users will look
to SAS to provide expanded connectivity and
greater scalability and to the 3ware 9690SA for
peace of mind.
Connect, Expand, Protect with SAS
End users will enjoy conguration exibility
with four low prole PCI Express controller
options: eight internal ports, eight external
ports, four internal/four external ports, or four
internal ports. Compatibility with industry
standard SAS expanders will maximize
exibility. Each 9690SA SAS controller scales
to support 128 SAS and/or SATA devices.
Advanced 3ware RAID architecture and SAS,
SATA, and SATA II performance features, including 3Gb/s and NCQ, help rocket the 9690SA to
RAID 5 and RAID 6 performance heights. An
optional Battery Backup Unit with integrated
write journaling and remote battery mounting
capability provides added data protection in the
event of a power outage. The 9690SA supports
RAID levels 0, 1, 5, 6, 10, 50, and Single Disk.
The RAID 6 Dierence
RAID 6 eliminates the risk of data loss if a second
hard disk drive fails while the RAID array is
rebuilding. Uniquely, in the 3ware RAID 6
implementation, two sets of parity are simultaneously calculated, written, and rotated across
all the drives. This second parity calculation
enables the array to survive up to two drive
failures without losing data, signicantly
improving fault tolerance. The 3ware RAID 6
double parity algorithm maximizes RAID 6
throughput, so that the 9690SA controllers
deliver unequaled RAID 6 write performance.
Enterprise-class RAID Storage
SAS is the preferred interface for the directattach server space, SCSI’s former mainstay.
SAS is for mission critical applications that
require higher levels of availability and native
expansion. SAS is optimized for the random
performance requirements of the data
center. The 9690SA’s advanced RAID features,
SAS connectivity, and powerful 3ware
performance architecture make it the ideal
SCSI controller replacement.
LSI 3ware 9690SA

3ware 9690SA Specications
3ware 9690SA Features
n
8th-generation StorSwitch™ non-blocking switched architecture
n
On-board I/O RISC processor and RAID ooad provides true
hardware RAID
– SCSI device driver model to take advantage of
SAS or inexpensive Serial ATA drives
n
Bootable array support for greater fault tolerance of your OS
n
Variable stripe size for performance tuning
by application
n
Support for greater than 2TB volumes
n
512MB DDR2 533 memory with ECC protection
n
128 max disk drives via SAS expanders
n
Complete conguration management suite
– 3ware BIOS Manager (3BM) – easy to use BIOS conguration tool
– 3ware Disk Manager 2 – browser-based management tool
– Command Line Interface (CLI) – scriptable conguration tool
n
SNMP support
n
SMTP support for email/pager notication
n
Staggered drive spin-up support
n
Auto carving allows LUNs > 2TB to be divided into multiple units
for legacy operating systems limited to 2TB max. per LUN
n
Battery Backup Unit (BBU) with remote battery support
n
Write journaling for improved performance and data protection
against accidental drive removal
n
Multiple SAS/SATA RAID sets
n
Multiple logical unit sizes and RAID levels on one card
n
Hot-swap and hot-spare support for data availability
n
Dynamic sector repair for robust data protection
n
S.M.A.R.T. disk drive monitoring for reliability
n
Emergency Flash Recovery protects against failed
rmware upgrade
n
Drive activity LED support
n
Array/Drive Status and drive identication LED support
n
Enclosure management support for SES 2.0 via I2C or
in-band signaling
n
Drive insertion and removal notication
n
Online Capacity Expansion and RAID Level Migration
n
RoHS 6 of 6 and WEEE compliant
Operating System Support
n
Microsoft® Windows® Vista/2003/XP, Mac OSX, Red Hat Linux,
SuSE Linux, Fedora Linux, 2.4 Linux kernel, 2.6 Linux kernel,
FreeBSD; 32/64-bit driver support for Windows, Linux and
FreeBSD. For complete OS listing, go to:
www.3ware.com/support/OS-support
3ware 9690SA Specications
n
Low prole form factor
n
PCI Express x8 congurations, PCI Express 1.1 compliant
n
Serial Attached SCSI (SAS) 1.1 specication support
n
SATA 2.6 specication support
n
BIOS PnP (plug and play) and BBS
(BIOS boot specication) support
n
Operating Temperature
Controller: 0°C to 50°C
BBU: 10°C to 40°C
n
Power Requirements: 18W maximum
n
Dimensions
9690SA-8I: 7.60”L x 2.73”H (19.30cm L x 6.93cm H)
9690SA-8E: 7.80”L x 2.73”H (19.80cm L x 6.93cm H)
9690SA-4I4E: 7.25”L x 2.73”H (19.30cm L x 6.93cm H)
9690SA-4I: 7.60”L x 2.73”H (19.30cm L x 6.93cm H)
Service and Support
n
3-year warranty
n
Support via the web at www.3ware.com/support
n
For latest motherboard and hard drive compatibility listing go to:
www.3ware.com/products//sys_compatibility.asp
Accessories
n
BBU-MODULE-04 Battery Backup Unit
n
BATT-SPARE-02 Replacement battery for BBU-MODULE-04
n
CBL-SFF8087-05M (0.5m Multi-lane internal cable)
n
CBL-SFF8087-06M (0.6m Multi-lane internal cable)
n
CBL-SFF8088SAS-10M (Universal key external cable, 1m)
n
CBL-SFF8088SAS-20M (Universal key external cable, 2m)
Applications for
3ware Controllers
Servers
Security/
Surveillance
Video
Editing
Super
Computing
NAS
Video
On-Demand
Pro Audio
Disk-to-Disk
Backup
3 W A R E 9 6 9 0 S A S E R I E S S E L E C T I O N G U I D E
9690SA-8I 9690SA-8E 9690SA-4I4E 9690SA-4I
Form Factor Low prole Low prole Low prole Low prole
SAS Ports 8 Internal 8 External 4 Internal / 4 External 4 Internal
Drive Interface SATA+SAS SATA+SAS SATA+SAS SATA+SAS
PCI Express x8 x8 x8 x8
RAID Levels 0, 1, 5, 6, 10, 50,
Single Disk
Onboard Memory 512MB DDR2 533 512MB DDR2 533 512MB DDR2 533 512MB DDR2 533
Connector Type SFF-8087 mini-SAS SFF-8088 mini-SAS SFF-8087/SFF-8088 mini-SAS SFF-8087 mini-SAS
BBU with Remote Battery Support Yes Yes Yes Yes
For more information and sales oce locations, please visit the LSI web sites at:
lsi.com 3ware.com
LSI, LSI and Design logo, 3ware, StorSwitch,StorSave, MultiLane and 3DM are trademarks or registered trademarks of LSI Corporation. All other
brand and product names may be trademarks of their respective companies.
LSI Corporation reserves the right to make changes to any products and services herein at any time without notice. LSI does not assume any
responsibility or liability arising out of the application or use of any product or service described herein, except as expressly agreed to in
writing by LSI; nor does the purchase, lease, or use of a product or service from LSI convey a license under any patent rights, copyrights,
trademark rights, or any other of the intellectual property rights of LSI or of third parties.
Copyright ©2009 by LSI Corporation. All rights reserved.
July 2009
0, 1, 5, 6, 10, 50,
Single Disk
0, 1, 5, 6, 10, 50,
Single Disk
0, 1, 5, 6, 10, 50,
Single Disk