Lowell SEQR-8 Specifications

Heard Everywhere Since 1947
Model No's.
SEQR-8, SEQR-8K
8-step Rackmount Sequencers
Eight step rackmount sequencer in 1U chassis provides time delayed ac­tivation and deactivation of equipment with full or alternate sequence mode (ASM). Typically used in conjunction with Lowell’s Remote Power Controls (RPC Series) and switches (RPS Series).
Spec No. 1605 | Rev. 06.09.16 | pg. 1/3
Features
• Sequential power control allows connected equipment to be turned on/off in time delayed order up to 8 steps.
• Rear programmable dip switch for Alternate Sequence Mode opera­tion
• Alternate Sequence Mode allows selected outputs to be by­passed for partial system operation (eg. rehearsals). Set ‘Se­quence Step Bypass’ termination block on or off for each of the eight steps. Install separate ASM style remote switch to activate alternate sequence operation (order separately). Note: The dry
contact may also be activated using devices by others. Switches to control full sequence and alternate sequence operations may be installed side by side in Decora-style wall plates or rackmount device panels.
• Alarm Interface: Integral override facilitates use in life safety ap­plications where fire code mandates an alarm interface.
• LEDs provide visual status of connected equipment
• Front adjustable delay allows .5-10 seconds between steps.
• Steel chassis: 19"W x 1.75"H x 9"D. Black.
• Eight barrier strip control outputs
• Each of the eight control outputs includes switch contacts for con­nection to remote power control-activated equipment and auxiliary dry contacts for the sequential activation of accessory systems such as projector screens, etc. To sequentially activate RPC connected equipment, each switch output contact (common, switched relay) is connected via 2 conductors to an RPC Series remote power control (order separately) and then to the equipment to be sequentially acti­vated. Note: Each output can be connected to one remote power con­trol with a single piece of equipment or up to ten remote power controls, in daisy chain format, with multiple pieces of equipment each. To sequentially activate accessory systems and/or indicator devices, each control output includes auxiliary contacts (normally closed, common, normally open) with a rating of 5A for connection to peripheral devices.
SEQR-8
SEQR-8K
• UL Listed power supply with input 100-240VAC, output 24VDC, 500mA, 6 ft. cord and four plug adaptors — NEMA 1-15 for North America (factory installed) Schuko CEE 7/16 for central Europe, BS1362 for the U.K., AS3112 for Australia/New Zealand.
• Choose rocker or key switch activation.
A&E Specifications
The device for sequentially activating equipment shall be Lowell rackmount Model No. ________ which shall feature a _____ (key, rocker) activation switch, LEDs and front accessible trim pot for delay adjustment of sequence operation. Rear panel shall fea­ture eight barrier strip terminals for remote power control units plus dry auxiliary contacts for accessory devices. It shall have a separate alarm interface connection and dip switch settings to bypass selected outputs.
Equipment to be controlled shall be connected to the sequencer using 2-conductor wire and Lowell's Remote Power Control __________ (RPC Series required, order separately). Rear panel shall include contacts to connect momentary switch ________ (RPSW-M, RPSB-M Series optional, order separately) for remote full sequence operation of sequencer and contacts for maintained style ASM switch ________ (RPSW-KP-ASM. RPSB-KP-ASM op­tional, order separately) to control alternate sequence operation.
Lowell makes every effort to provide accurate information while reserving the right to change specifications and/or improve manufacturing methods without notification. ©2015 Lowell Manufacturing Company, 100 Integram Dr., Pacific MO 63069 | tel. 800.325.9660 | www.lowellmfg.com
Heard Everywhere Since 1947
FLASHING = Down cycle in progress.
STEADY ON = Down cycle completed (system off).
Red LED
Green LED
FLASHING = Up cycle in progress. STEADY ON = Up cycle completed (system on).
Spec No. 1605 | Rev. 06.09.16 | pg. 2/3
Yellow LED- Alternate Sequence Mode activated
Actuation Switch
Starts sequence up or down. Activation in in mid-cycle reverses direction of cycle. Switch Style: Rocker = SEQR-8, Key = SEQR-8K
8 Auxiliary Dry Contacts*
Normally Closed
Common
Normally Open
* May be used to control other systems
(projector screens, lighting, blinds, etc) or
indicators. contact rating is 5A max.
Includes UL Listed Power Supply 24 VDC 500 mA
Alarm System
Interface
If required by local building code, facility usage, or the Fire Marshal; the system switches can be overridden and the system controlled by
contact closures provided the fire alarm panel or other similarly in­stalled device. A maintained contact between the ‘com’ terminal and any of the terminals shown will provide the following functions.
Lock Off
: A maintained contact between the ‘com’ terminal and the ‘lock off’ terminal will turn the system off and keep it off regardless of other switch activations. If the system is al­ready off, it will be kept off.
Lock On
: A maintained contact between the ‘com’ terminal and the ‘lock on’ terminal will turn the system on and keep it on regardless of other switch activations. If the system is al­ready on, it will be kept on.
Switch Lock
: A maintained contact between the ‘com’ terminal and the ‘switch lock’ termi­nal will lock the system in its current state, ei­ther on or off, regardless of any other switch activations. Note: Switch lock function is over-
ridden by External Trigger voltage.
Caution: Do not allow alarm system to make more than one of the above described contacts at the same time. Controller board damage may result.
Green LED's- Indicate progress of UP and DOWN sequence Delay - Recessed trim pot with screwdriver adjust.
8 Switch Contacts for Remote Power Controls*
Common Switched Relay
*Up to 10 Remote Power Controls (RPC) units can be controlled by each sequencer step. Note: common connections from multiple remote RPC
units (controlled by different sequence steps) can be consolidated into one conductor and connected to any common terminal at the sequencer.
Remote Switch(es)
Optional - up to 8 momentary switches
may be connected in parallel.
Flashing LED = cycle in progress Steady on LED = cycle finished
Momentary Switches with 2 LED’s
Wallplate Series RPSW2-MP (white), RPSB2-MP
(black), 1RU panel Model RPSB2-MR
Flashing LED = cycle in progress Steady on LED = cycle finished
Wallplate Series RPSW-MP (white), RPSB-MP (black),
Momentary Switches with 1 LED
1RU panel Model RPSB-MR
Maximum wire distances
24ga: 20,000 ft (aprox. 3.5 miles), 22ga.: 31,200 ft.
(aprox. 5.5 miles), 18ga.: 76,800 ft. (aprox 13.5 miles)
Alternate Sequence
Mode (ASM)
V+
Maintained ASM Switch with 1 LED (yellow)
Wallplate Series RPSW-KP-ASM (white),
Sequence Step
Bypass
RPSB-KP-ASM (black),
Com Sw
Alternate Sequence Mode (ASM) allows for the bypassing of selected outputs for partial system operation (rehearsals, small events, etc.).
The easy-to-use bypass on the rear of the unit is a programmable DIP switch (See Sequence Step Bypass above). Choose steps to be by­passed and set the corresponding DIP switches. When contact closure is applied between ‘Com’ and ‘Sw’ the chosen steps will be skipped.
Remote switching in Alternate Sequence Mode requires a special keystyle switch Model RPSW­KP-ASP (white) or RPSB-KP-ASP (black).
Systems can include both an ASM switch and a standard re­mote switch mounted separately or side by side.
Note:
Lowell makes every effort to provide accurate information while reserving the right to change specifications and/or improve manufacturing methods without notification. ©2015 Lowell Manufacturing Company, 100 Integram Dr., Pacific MO 63069 | tel. 800.325.9660 | www.lowellmfg.com