Lowell SEQ-8 Specifications

Heard Everywhere Since 1947
Model No.
SEQ-8
Low Voltage Sequencer
Compact low voltage 8-step sequencer combines with low voltage remote power controls and switches to provide time­delayed activation and deactivation of AC powered equipment on site or in a remote location. Sequence delay is screwdriver adjustable with .5-10 seconds between steps. Sequencing is initiated by an external remote switch (order separately).
Spec No. 1603 | Rev. 04.14.16 | pg. 1/3
Features
Eight delayed closure circuits activate in sequential order and deactivate in reverse order.
Slide switch allows selection of single or multiple switch modes.
Sequencing is initiated by a single remotely located SPST main­tined contact closure switch or multiple SPST normally open mo­mentary closure switches (order separately).
LED indicators provide visual status of each control circuit as well as power verification.
Includes auxiliary 24VDC, 300mA (max) output for remote indica­tors.
Steel chassis with black finish measures 10"L x 3.281"W x 1.687"H. Includes mounting holes and operational diagram.
UL Listed power supply with input 100-240VAC, output 24VDC, 500mA, 6 ft. cord and four plug adaptors — NEMA 1-15 for North America (factory installed) Schuko CEE 7/16 for central Europe, BS1362 for the U.K., AS3112 for Australia/New Zealand.
Made in U.S.A. with domestic and imported components
A&E Specifications
The device for sequentially activating equipment connected to remote power controls shall be Lowell Model No. SEQ-8, which shall feature bar­rier strip terminals for connection to remote power control Model No. RPC­________. Contacts shall also be available for connecting remote switches (required) for activation.
[ Applications with multiple switch actuation shall use momentary wall switch Model No. _____ or momentary rack panel switch Model No. ______. Applications with single switch actuation shall use maintained wall switch Model No. ___ or maintained rack panel switch Model No. _____. ]
Model Number Summary
Model Description Control Circuit Delay Power Actuation Switch-SPST** Power Controls
Outputs* (barrier strip) (between steps) Requirement (order separately) (order separately)
SEQ-8 Sequencer, low voltage 8 circuits + (1) 24VDC out 0.5-10 sec. 117VAC, 60Hz, 12W Single (maintained), multiple (momentary) RPC Series
* Each circuit controls up to ten RPC Series remote power controls (order separately) ** External switches (maintained or momentary) are required (order separately)
NOTE: Model No. SEQ-8 was formerly known as no. SCS-8
Lowell makes every effort to provide accurate information while reserving the right to change specifications and/or improve manufacturing methods without notification. ©2016 Lowell Manufacturing Company, 100 Integram Dr., Pacific MO 63069 | tel. 800.325.9660 | www.lowellmfg.com
Spec No. 1603 | Rev. 04.14.16 | pg. 1/3
Heard Everywhere Since 1947
System Accessories (order separately)
Remote Power Controls- ETL Listed
RPC-15 Power Control 15A 1 duplex 7.5 x 3.25 x 1.75 6 ft cd RPC-20-CD Power Control 20A 1 duplex 7.5 x 3.25 x 2.75 6 ft cd RPC-30-SHW Power Control 30A 1 twistlock 7.5 x 3.25 x 2.75 6 ft conduit RPC-20-SCD Power Control 20A 1 duplex 7.5 x 3.25 x 2.75 surge suppression 6 ft cd
Remote Switches - Maintained Closure (single switch use) - keylock also available
RPSW-P Switch SPST rocker switch with 1 LED maintained 1 gang wall plate RPSB-R Switch SPST rocker switch with 1 LED maintained 1U rack panel
Remote Switches - Momentary Closure (multiple switch use) - keylock also available
RPSW-MP Switch SPST rocker switch with 1 LED momentary 1 gang wall plate RPSW2-MP Switch SPST rocker switch with 2 LED momentary 1 ga wall plate RPSB-MR Switch SPST rocker switch with 1 LED momentary 1U rack panel RPSB2-MR Switch SPST rocker switch with 2 LED momentary 1U rack panel
Typical Wiring — Single Switch "MAINTAINED Contact" Connections
Maximum distance between switches, RPC units and SEQ-8: 22 ga –6,600 ft. or 1.25 miles; 18 ga –17,160 ft. or 3.25 miles
Lowell makes every effort to provide accurate information while reserving the right to change specifications and/or improve manufacturing methods without notification. ©2016 Lowell Manufacturing Company, 100 Integram Dr., Pacific MO 63069 | tel. 800.325.9660 | www.lowellmfg.com