Lowell ACSPR-SEQ6-2009 Specifications

pec No. 1609 | Rev. 09.16.15 | pg. 1/2
S
Heard Everywhere Since 1947
Model No.
ACSPR-SEQ6-2009
Rackmount panel with 9 outlets, sequencer, surge suppression
Features
• Delay between sequenced steps (0.5-10 seconds) is screwdriver adjustable
• Power rating of 120VAC, 60Hz/20A with EMI/RFI fil­tering. Each receptacle rated 15A.
• Rear termination blocks accommodate remote switches, external triggers and an alarm system in­terface for use where mandated by fire code.
• Includes two dry contact closures (steps 5 and 6) for triggering remote power control units (RPC se­ries, order separately).
• Actuation Switch: front panel rocker switch with mo-
mentary contacts (normally open SPST) plus rear barrier strip termination blocks for momentary (nor­mally open) remote switches.
• Alarm Interface: lock on, lock off and switch lock
functions for alarm system or master control panel applications.
• External Control Connections: plug-in barrier strip
terminal blocks
• EMI/RFI Filter: 19dB@500kHz, 42dB@30MHz
• Termination via 9 ft. attached cord with NEMA 5-20P plug.
• Dimensions: 19"W x 1.75"H (1U) x 9"D
• Made in the U.S.A.
• ETL-listed in the U.S. and Canada to UL Standard 60065
UL1449-2 adjunct results: 1000 surges, 6000 volts, 3000A, C1 and B3 waveforms (IEEE C62.41), no fail­ures.
– LEDs indicate status: if one section of the surge
suppressor has reduced protection, there are two additional sections available to safeguard equip-
ment. – Initial Clamping Voltage: 205V, UL rating 330V – Endurance: IEEE C62.41-1991, B3 (C1), Pulses
(lifetime): 1kv≥1,000,000; 3kv≥100,000; 6kv≥5000
– Transient Noise Reduction: 25dB@100kHz,
50dB@1MHz – Response Time: less than 5 nanoseconds – Applicable Standards: IEEE standard 587-80 A & B,
IEEE standard C62.41-1991, IEC 1000-4-5-1995 (IEC
801-5). – Protection Mode: line to neutral, zero ground leakage.
A & E Specifications
The sequential AC rackmount power panel shall be Lowell Model No. ACSPR-SEQ6-2009. It shall be ETL listed and have a power rating of 120VAC, 60Hz/20A with EMI/RFI fil­tering and a total of 9 outlets (6 switched, 3 unswitched) and 2 steps providing contact closures to sequentially ac­tivate/deactivate equipment (4-6 steps) with a sequence delay of 0.5 to 10 seconds. It shall be housed in a 1U steel rackmount chassis measuring 19"W x 1.75"H x 9"D and having color-coded LEDs. Activation shall be via a rocker switch on the front panel. The panel shall also include surge suppression
Note: Formerly Model No. ACSPR-SCS4-2009-RT2
Lowell makes every effort to provide accurate information while reserving the right to change specifications and/or improve manufacturing methods without notification. ©2015 Lowell Manufacturing Company, 100 Integram Dr., Pacific MO 63069 | tel. 800.325.9660 | www.lowellmfg.com
pec No. 1609 | Rev. 09.16.15 | pg. 2/2
S
FLASHING = Down cycle in progress.
Red LED
STEADY ON = Down cycle completed (system off).
Rocker switch
activation
Includes 9-ft. attached cord with NEMA 5-20P plug.
Green LED
FLASHING = Up cycle in progress. STEADY ON = Up cycle completed (system on).
Green LEDs – Indicate
Delay – recessed trim
pot with screwdriver
progress of UP and DOWN sequence
adjust
Circuit Breaker
Surge Suppression & Ground Protection
Green LEDs – Verified, Full Protection Red LED – Reduced Protection
Rear view
ALARM SYSTEM INTERFACE
If required by local building code, facility usage, or the Fire Marshal; the system switches can be overridden and the system controlled by contact closures provided by the fire alarm panel or other control system. A maintained contact between the “com” terminal and any of the terminals shown here will provide the fol­lowing functions.
Lock Off: A maintained contact between the “COM” terminal and the “LOCK-OFF” terminal will turn the system off and keep it off regard­less of other switch activations. If the system is already off, it will be kept off.
Lock On: A maintained contact between the “COM” terminal and the “LOCK-ON” terminal will turn the system on and keep it on regard­less of other switch activations. If the system is already on, it will be kept on.
Switch Lock: A maintained contact between the “COM” terminal and the “SWITCH-LOCK” terminal will lock the system in its current state, either on or off, regardless of any other switch activations.
Caution: Do not allow alarm system to make more than one of the contacts described above at the same time. Controller board damage may result.
Maximum wire distances
24ga: 20,000 ft (approx. 3.5 miles), 22ga.: 31,200 ft.
(approx. 5.5 miles), 18ga.: 76,800 ft. (approx. 13.5 miles)
RPC TRIGGER CONNECTIONS REMOTE SWITCH CONNECTIONS
Multiple RPC series remote power control units can be connected to outputs 5 and 6 (60
Connect a maximum of 5 remote MOMENTARY
switches. Order switches separately.* max. each, dependent upon limits of electrical panel). Order RPC units separately.
RPC series remote power controls.
* See MOMENTARY switches:
with 2 LEDs: RPSB2-MP, RPSB2-MKP, RPSW2-MP, RPSW2-
with 1 LED: RPSB-MP, RPSB-MKP, RPSW-MP, RPSW-MKP,
Four conductors (2 LED switch).
Three conductors (1 LED switch).
MKP, RPSB2-MR, RPSB2-MKR
RPSB-MR, RPSB-MKR
Lowell makes every effort to provide accurate information while reserving the right to change specifications and/or improve manufacturing methods without notification. ©2015 Lowell Manufacturing Company, 100 Integram Dr., Pacific MO 63069 | tel. 800.325.9660 | www.lowellmfg.com