Lowell 25LVC-RM Datasheet

Spec No. 1179 | Rev. 04.08.15 | pg. 1/2
Heard Everywhere Since 1947
Rackmount Volume Controls
• Rotary Knob with Adhesive Dial Scale
• 25W, 50W, or 100W power rating
Features
• Precise level adjustment of single or multiple speaker lines.
• Adhesive dial scale
• Easy-connect phoenix-style plug-in screw termina­tion strips for pre-wire convenience
• Wire capacity to 14-gauge
• Power rating 25W-100W (see chart)
• ETL Listed
• Assembled in the U.S.A.
Includes rotary knob and adhesive label.
A & E Specifications
The volume control shall be Lowell Model No. _________ which shall have a power rating of _______ (25W, 50W, 100W) and attenuation of 3dB per step with two steps of 6dB each before off. It shall include a rotary knob and adhesive label with dial scale. The control shall be ETL Listed.
Optional (order separately)
• Panel No. LVC8P-ID2: Rackmount panel provides
easy installation of multiple volume controls (LVC
PocketID™ window for paper label strip
Series). The 19" x 2U panel includes a rear lacing flange for wire management and a clear pocket window (PocketID) to hold a half-inch paper strip
Optional rackmount panel holds up to 8 volume controls (order separately)
for labeling the controls. Download a template from www.lowellmfg.com.
Model No. Summary
Power Switch Switch Attenuation *
Model No. Description Rating Type Type Positions Step / Total Style
25LVC-RM Volume Control 25W Auto-trans Rotary 10-off 3dB / 33dB Adhesive label
50LVC-RM Volume Control 50W Auto-trans Rotary 10-off 3dB / 33dB Adhesive label
100LVC-RM Volume Control 100W Auto-trans Rotary 10-off 3dB / 33dB Adhesive label
* Models have two steps of 6dB each before off
Lowell makes every effort to provide accurate information while reserving the right to change specifications and/or improve manufacturing methods without notification. ©2015 Lowell Manufacturing Company, 100 Integram Dr., Pacific MO 63069 | tel. 800.325.9660 | www.lowellmfg.com
IN OUT
Attenuator
(re ar v iew)
IN OUT
Line From
Amplifier
Output To
Speaker(s)
Com (neg.)
Plus (pos.)
Com (neg.)
Plus (pos.)
INPUT
OUTPUT
Full Volume
-3dB
-6dB
-9dB
-12dB
-15dB
-18dB
-21dB
-27dB
-33dB
Off
Speaker Line
(25V, 70V, or 100V)
From amplifier
To speaker(s)
with transformers
Attenuation:
3dB per step, last two steps 6d B
(33dB total)
Heard Everywhere Since 1947
Wiring & Schematic
Spec No. 1179 | Rev. 04.08.15 | pg. 2/2
Lowell makes every effort to provide accurate information while reserving the right to change specifications and/or improve manufacturing methods without notification. ©2015 Lowell Manufacturing Company, 100 Integram Dr., Pacific MO 63069 | tel. 800.325.9660 | www.lowellmfg.com