Lovibond EC 2000 Gardner Operator's Instruction Manual

Page 1
1
EC 2000 Gardner
LM162020 Version 1.1
Lovibond® Water Testing and Colour Measurement
Page 2
2
Table of Contents
Environment: ................................................................................................ 4
Introduction: ................................................................................................ 5
Keypad:......................................................................................................... 6
Display Icons:................................................................................................ 6
Power- USB: ................................................................................................. 6
Power- Battery: ............................................................................................ 6
Firmware and Version Number: ................................................................... 7
Settings ......................................................................................................... 8
Instrument Diagnostics ............................................................................ 8
Instrument Settings .................................................................................. 9
Information ............................................................................................ 11
Power Saving Settings ............................................................................ 11
Regional Settings .................................................................................... 12
Date and Time ........................................................................................ 12
Projects: ..................................................................................................... 13
New Projects .......................................................................................... 13
Set Tolerances ........................................................................................ 14
Averaging and Automatic Log (automatic saving) ................................. 15
Edit a Project .......................................................................................... 16
Delete a Project ...................................................................................... 16
Make a Project Default .......................................................................... 17
Make a Project Current .......................................................................... 18
View the Measurements ........................................................................ 18
Delete a Measurement .......................................................................... 18
Page 3
3
Save a Measurement (manual saving) ................................................... 19
Error Warnings: .......................................................................................... 20
Updating the firmware: .............................................................................. 21
EC 2000 Kit Contents - Gardner: ................................................................ 23
EC 2000 Technical Data - Gardner ............................................................. 24
Performing a Zero – Gardner: .................................................................... 26
Performing a Test - Gardner: ..................................................................... 28
Performing a Liquid Instrument Validation–Gardner ................................ 30
Performing an Instrument Validation using a Glass Standard – Gardner .. 33
Sales Offices ............................................................................................... 35
Page 4
4
Environment:
This appliance is marked according to the European Directive 2002/95/EC on the waste of Electrical and Electronic Equipment (WEEE). By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product.
Page 5
5
Introduction:
The Lovibond® EComparator Series provides an easy way to transition from subjective visual measurement to a non-subjective, accurate electronic measurement.
Colour graders who are used to the traditional comparator series sometimes find the upgrade or transition to an electronic system daunting. The assurance of relying on physical colour difference is diminished.
With the EComparator Series, users can view the colour in two different ways:
On-Screen Numerical Display
On-Screen Colour Display of sample and nearest colour scale standards
Touch screen technology allows the EComparator Series to show simple, specific and intuitive menus on screen. Users can set language, date and time, view preferences and create projects with individual tolerance settings. An on-screen warning system of: Within Tolerance = Green; Outside Tolerance = Red; On Border of Tolerance = Amber provides the user with immediate information on the sample.
The user friendly ergonomics and intuitive interface guarantee new users can be quickly trained and easily supported. Large data storage (> 20,000 readings), USB connectivity ensure readings can be stored and shared easily and quickly. Flexibility is further enhanced with software packages for Windows®, IOS® and Android
TM
with multiple language support on-screen.
Page 6
6
Keypad:
Display Icons:
Power- USB:
Power- Battery:
Icon
Function
Battery Low
Powered by Battery
Powered by USB
SD Card OK
Warning
Test
Zero
Power
The USB port can be accessed by sliding the panel at the rear of the instrument.
The batteries can be replaced by removing the 4 x screws at the back of the instrument and removing the battery cover.
Ensure the cable connector is inserted into the socket in the correct orientation. The symbol on the USB connector should be facing down.
Top of Connector
Top of Instrument
Page 7
7
Firmware and Version Number:
The Firmware and Version Number will be displayed when the instrument is switched on.
(Please Note: “Scale Name” will be replaced by the Scale your EComparator measures).
Page 8
8
Settings
1 - To enter the settings menu, press the settings icon at the bottom tool bar.
1a -The settings display will show.
Instrument Diagnostics
2 - For Instrument Diagnostics, press the Diagnostics Icon.
2a - The instrument will perform diagnostics on the Memory, SD Card, LED and Light Sensor.
2b - Any errors will be shown in red.
To view detailed information select Report.
Please contact you local service centre for help.
www.lovibondcolour.com/ServiceCenter
Page 9
9
2c - The instrument will display the report. When finished, select Done.
Instrument Settings
3 - For Instrument Settings, press the Instrument Icon
3a – To set the integration time, ensure the sample chamber is empty, and then press Set.
(This will set the optimum time for taking a measurement).
3b– The instrument will advise to check the Sample Chamber. Press OK when empty.
3c – The instrument will determine the integration time, a series of numbers will appear on the screen.
Page 10
10
3d – Click OK when complete.
3e - To save the settings, press Save.
3f - To cancel the settings, press Cancel.
3g – To exit without saving, press Yes, or press No to continue.
Page 11
11
Information
4a – The information screen will be displayed. Press the back arrow to return to the results screen.
(Please Note: “Scale Name” will be
replaced by the Scale your EComparator measures).
Power Saving Settings
5 - For Power Saving Settings, press the Power Icon.
5a – Press the up and down arrows to adjust the time interval before the display goes to sleep in minute increments.
5b – Press the up and down arrows to set the time interbal before the instrument shuts down after being inactive.
To restart the instrument, press the power button.
5c - To save the settings, press Save, or to cancel the changes, press Cancel.
5d- If screen starts to dim, press anywhere on the screen to turn backlight on.
Page 12
12
Regional Settings
6 - For Regional Settings, press the Regional Icon.
6a - Select the language that you would like the instrument to display.
The instrument will return to the settings screen.
Date and Time
7 - To set the Date and Time, press the Clock Icon.
The current time shown is the time the screen was opened, and does not continuously update.
7a – Use the up and down arrows to set the date and time.
7b - To save the settings, press Save, or to cancel the changes, press Cancel.
Page 13
13
Projects:
1 - To enter the projects menu, press the Projects Icon on the bottom tool bar.
2 – The projects screen will be displayed. The Project named at the top is the current project.
3 – To view, or manage projects, click on View Projects.
New Projects
4 – This will bring up a list of the current projects. To create a New Project, click on New.
5 – To change the name, select the name box.
Page 14
14
6 – Enter the new project name using the keypad, then select Return.
Set Tolerances
7 – The instrument will display the Project Settings Screen, to set the Tolerances, select Tolerance.
8 – To apply the tolerance limits, select the Tolerance checkbox.
9 – To change the tolerance values, use the appropriate up and down arrows. Select Done when complete.
Page 15
15
Averaging and Automatic Log (automatic saving)
10 – To change the Averaging and Automatic Log (automatic saving), select Measurements.
11 – To change the Averaging, use the up and down arrows
(This will set the number of measurements taken per test then take an average of those measurements).
12 – To set the automatic logging, select the Automatic Log checkbox. This will save every measurement that is taken. Select Done when complete.
Page 16
16
13 – To save all the settings, select Save.
NOTE: Until save is selected, neither Tolerance nor Measurements are saved.
Edit a Project
14 – To edit a project, go to the projects list. Highlight the project by clicking on it, and then select Edit.
15 – This will bring you to the Project Settings Screen. To make changes follow steps 6-12.
Delete a Project
16 – To delete the project, select Delete.
Page 17
17
17 – The following prompt will appear. Select Yes to confirm.
Make a Project Default
18 – To make a project Default, go to the projects list (this will highlight the project that is current when the instrument is switched on). Highlight the project and select Edit.
19 – Select Default.
20 – The following prompt will appear. Select Yes to confirm.
NOTE: The first project (ID 1) can not be deleted, but can be re­named.
Page 18
18
Make a Project Current
21 – To make a project current, go to the project list, highlight the project required then press Select. All readings will be saved into the current project.
View the Measurements
22 – To view the measurements of a project, go to the projects list, highlight the project required then press Meas.
23 – This will bring up a list of the measurements stored for this project. If the tolerance limits are switched on (step 7), the results will be displayed as in the tolerance column (see page 15)
Delete a Measurement
24 – To delete a measurement, highlight the measurement then select Delete.
Page 19
19
25 – The following prompt will appear. Select Yes to confirm.
26 – To view the measurements from the main project screen for the current project (named at the top of the screen), select View Measurements.
Save a Measurement (manual saving)
27 – If automatic saving is not enabled, you can save every measurement taken by selecting Projects.
28 – On the main projects screen, select Save Measurement. This will save to the current project.
Page 20
20
Error Warnings:
Warning
Description
Error 1
SD Card Error
Error 2
Light Level Too High
Error 3
Light Level Too Low
Error 4
Sensor Error
Error 5
File System Error
Error 6
Communication Error
Error 7
Keypad Error
Error 10
Non Volatile Memory Error
Please contact you local Service Centre for help:
www.lovibondcolour.com/ServiceCentre
Page 21
21
Updating the firmware:
The latest version of the EC 2000 and EC 3000 firmware can be obtained from the internet, www.lovibondcolour.com
1 - Ensure that the EComparator Instrument is connected to a Computer running a Microsoft® Operating System (XP,7,8).
NOTE: This update cannot be
performed on an Apple Mac or Linux® system
2 – Switch off the instrument.
3 – Press and hold down the test key on the keypad whilst switching on the EComparator Series instrument.
4 – A drive named “EC_UPDATE” will appear on your PC.
Page 22
22
5 - Open the drive “EC_UPDATE” the contents of the drive will show a file named “firmware.bin”.
6 - Delete the file “firmware.bin”
7 - Now copy the Update File onto this drive.
8 - Switch OFF the Instrument and then switch back it ON. The instrument will restart with the updated firmware.
Page 23
23
EC 2000 Kit Contents - Gardner:
Item
Included
Instrument Type
EC 2000
Power Supply
USB Cable
Screwdriver
Pot of 4x AA Batteries
Liquid Reference Standard 1
Glass Cell
1x W100 OG 10 mm
Plastic Cell
3x W100 10 mm
Glass Reference Standard 1
Spare Cell Divider
= Available in the kit
EC 2000 Series Instrument
USB Power Supply
4 x AA Batteries
EComparator Reference Solution
EComparator Reference Solution
Glass and Plastic Cells
USB Cable
Mini Screwdriver
Cell Divider
Glass Reference Standards
Page 24
24
EC 2000 Technical Data - Gardner
The Gardner Colour scale as specified in ASTM D1544 is a single number, one dimensional, colour scale for grading the colour of similarly coloured liquids such as resins, varnishes, lacquers, drying oils, fatty acids, lecithin's, sunflower oil and linseed oil.
The scale ranges from a pale yellow to a red in shade and is described in terms of the values 1-18. To comply with specifications, a 10mm path length must be used.
The light yellow Gardner colour numbers (1 to 8) are based on potassium chloroplatinate solutions, numbers 9 to 18 on solutions of ferric chloride, cobaltous chloride and hydrochloric acid.
Guaranteed Agreement with International Standards; for many product types, a characteristic set of standards was agreed and adopted to aid colour control and the communication of colour specifications worldwide; the result is a selection of colour grading scales that have been adopted as international industry standards.
The EComparators are fully equivalent to the appropriate Visual International Standards and fully compliant with Automatic International Standards detailed below:
EC 2000 Gardner (ASTM D1544, D6166, ISO 4630-2) because in section “Significance and use” of ASTM D6166 section 4.1, “This test method
provides a more precise way of measuring Gardner Colour than described in Test Method D1544.” In the Scope of ISO 4630-2 it states “The method
described provides a more precise way of measuring Gardner colour than that described in ISO 4630-1”.
Page 25
25
Parameter
Details
Colour Scales
Gardner
Range
0 to 18
Resolution
0.1
Repeatability
± 0.2
Page 26
26
Performing a Zero – Gardner:
1 – Once initiated, the instrument will display.
2 - Ensure there is no cell in the sample chamber.
3 - Insert the cell divider in the groove in the sample chamber as shown. 4 - Close the sample lid and press the zero key on the keypad or the display.
5 - While performing a zero, the instrument will display:
Page 27
27
6 - When complete, the instrument will display:
Page 28
28
Performing a Test - Gardner:
Note: Ensure that the sample being measured is free from turbidity; if
necessary, filter the sample through a 0.45 micron filter paper.
1 - Insert the cell divider in the groove in the sample chamber as shown.
2 – Fill a clean Cell 2/3 full with the sample.
3 - Place the cell in the sample chamber of the EC2000 Gardner, on the left hand side of the cell divider.
4 - Close the sample lid and press the test key on the keypad or the display.
5 - While performing a test, the instrument will display:
Page 29
29
6 – If averaging is set the instrument will display:
7 - The instrument will display the result as:
8 - Press the result button on the display to change between numeric and comparator mode
9 - Press the up and down arrows to view the stages / steps as they would be on the visual disc.
Page 30
30
Performing a Liquid Instrument Validation–
Gardner
The EC 2000 Gardner is supplied with one bottle of Validation Liquid.
This liquid is used to validate that the instrument is measuring within the specified tolerances
1 –Select the bottle of validation liquid and ensure that the selected validation liquid is within its expiry date.
2 – Ensure the sample chamber is empty.
3 - Insert the cell divider in the groove in the sample chamber as shown. 4 - Close the sample lid and press the Zero key.
Page 31
31
5 - While performing a zero, the instrument will display:
6 – Fill the supplied 10 mm cell 2/3 with the reference solution.
7 - Place the cell in the sample chamber of the EC2000 Gardner.
8 - Close the sample lid and press the test key on the keypad or the display.
9 - While performing a test, the instrument will display:
Page 32
32
10 - The instrument will display the result.
11 - Compare the result from the instrument to the value on the label of the validation liquid, to check it is within the specified tolerances.
Page 33
33
Performing an Instrument Validation using a
Glass Standard – Gardner
1 –Ensure the sample chamber is empty
2 - Insert the cell divider in the groove in the sample chamber as shown, and close the lid 3 – Press the zero key
4 - While performing a zero, the instrument will display:
5– Place the selected standard in the sample chamber on the right hand side.
Page 34
34
6– Press the test key on the keypad.
7 - While performing a test, the instrument will display:
8– The result will be displayed on the screen. Compare these results to those on the label of the standard.
9 - Press the back arrow on the display to change between numeric and comparator mode.
Page 35
35
Sales Offices
Germany
Tintometer GmbH Lovibond® Water Testing Schleefstraße 8-12 44287 Dortmund Germany
Tel: +49 (0)231/94510-0 Fax: +49 (0)231/94510-20 Email: sales@tintometer.de
United Kingdom The Tintometer Ltd Lovibond House Solar Way Solstice Park Amesbury SP4 7SZ
Tel: +44(0)1980 664800 Fax: +44(0) 1980 625412 Email: sales@tintometer.com
North America Tintometer Inc 6456 Parkland Drive Sarasota Florida 34243 USA Tel: +1 941 758 8671 Fax: +1 941 727 9654 Email: sales@tintometer.us
South East Asia Tintometer South East Asia Unit B-3-12-BBT One Boulevard, Lebuh Baku Nilam 2, Bandar Bukit Tinggi, Klang, 41200, Selangor D.E MALAYSIA. Tel: +60 (0) 3 3325 2285/6 Fax: +60 (0) 3 3325 2287 Email: lovibond.asia@tintometer.com
Switzerland Tintometer AG Hauptstraße 2 5212 Hausen AG Switzerland
Tel: +41 (0)56/4422829 Fax: +41 (0)56/4424121 Email: info@tintometer.ch
China Tintometer China Room 1001, China Life Tower, 16 Chaoyangmenwai Avenue Beijing 100020 China Tel: +89 10 85251111 ext.330 Fax: +86 10 85251001 Email: chinaoffice@tintometer.com
India
Tintometer India Pvt. Ltd. B-91, A.P.I.E. Sanath Nagar, Hyderabad 500018 India Tel: +91 (0) 40 4647 9911 Toll Free: 1 800 102 3891 Email: indiaoffice@tintometer.com
Page 36
36
www.lovibond.com
Lovibond® and Tintometer® are registered trademarks of The Tintometer Ltd. Amesbury, UK. All translations and transliterations of Lovibond® and Tintometer® are asserted as trademarks of The Tintometer® Group.