File EV23684
Project 4786378208
June 09, 2014
REPORT
on
Household Refrigerator-freezer Verified for Energy Efficiency
Ningbo Hicon International Industry Co Ltd
Ningbo, China
Copyright © 2014 UL LLC
UL LLC authorizes the above named company to reproduce this Report
provided it is in its entirety.

File EV23684 Vol. 1 Sec. 36 Page 1 Issued: 2014-06-09
Corresponding Alternate Model
HC31TG42SV, HC32TW10SB, HC32TW10SV, HC31TF11SB,
HC32TG42SB, HC32TG42SW, HC32TG42SS, HC32TG63SV,
HC32TG63SB, HRC3251BL*, HRC3251AC*, FR832I-**,
FR832I-B-**,FR832I-E-**,FR834C-**,FR834I-C-**,
FR834I-E-**,FR834I-F-**,FR834IB-**,FR834IB-B-**,
RFR835-**,RFR835-B-**,RFR836-**, CCRD32*.
and Report Revised: 2022-01-21
DESCRIPTION
PRODUCT COVERED:
USEV, CNEV Compact Refrigerator-Freezer, Model BCD-90-E,
HC31TG42SV,HC32TW10SB,HC32TW10SV ,HC31TF11SB, HC32TG42SB, HC32TG42SW,
HC32TG42SS, HC32TG63SV, HC32TG63SB, HRC3251BL*, HRC3251AC*(* may be a letter
of B,W,S,V or G and so on which indicates the different color or appearance
of the products), FR832I-**,FR832I-B-**,FR832I-E-**,FR834C-**,FR834I-C**,FR834I-E-**,FR834I-F-**,FR834IB-**,FR834IB-B-**,RFR835-**,RFR835-B**,RFR836-**( ”*” means color),CCRD32*.
GENERAL:
except for the model designation.
The corresponding alternate models are identical to the basic model
All other models specified in Section 36, Volume 1 in Index are
identical to the basic model BCD-90-E except for model designation.
This product has been evaluated to determine their volume and energy
consumption.
This file authorizes the UL Energy Verification Mark. Another file, as
referenced below, authorizes the UL Listing Mark. It should be noted that
the Listing file and the Energy Verification file are independent and
compliance in one file does not indicate compliance in the other file. When
evaluating construction changes, additional consideration should be given to
how this change may effect compliance with UL 250 and the Listing file.
The nominal volume of Model BCD-90-E is 90 liters (3.2 cu. Ft.)
The unit has a fresh food compartment for storage of food at an average
temperature above 32 F (0 C) and a compartment designed for the freezing and
storage of frozen foods at temperatures of 8F (-13.3C) average or below.
The unit has partial automatic defrost. Anti-sweat heaters are not provided.
The unit employs a static condenser and a static evaporator. Freezer
compartment temperatures are adjustable by user operable controls.
TECHNICAL CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE'S USE):
*USEV – Products designated USEV have been investigated using US DOE and CEC
requirements as noted in the Test Record.
*CNEVProducts designated CNEV have been investigated using NRCAN requirements
as noted in the Test Record.
*.
CONSTRUCTION DETAILS:
The models covered in this Report are listed in File SA12695, Vol. 1, Sec.
11. Refer to this Report for descriptions of all other critical construction
features.

File EV23684 Vol. 1 Sec. 36 Page 2 Issued: 2014-06-09
(VFF)
Fresh Food
Compartment
Volume, L (ft3)
(VF)
Freezer
Compartment
Volume, L (ft3)
(VT)
Total
Refrigerated
Volume, L (ft3)
(VA)
Adjusted
Volume, L (ft3)
Annual Energy
Consumption
(kW-hr/Year) (+)
Max. Annual Energy
Consumption (kWhr/Year) (++)
Estimated Annual
Operating Cost
($/Year) (+++)
BCD-90-E
(compressor
B43C5B,L48C
5L,TK48C5)
Type 12. Compact
refrigeratorfreezers—partial
automatic defrost
Type 12. Compact
refrigeratorfreezers—partial
automatic defrost
and Report Revised: 2022-01-21
For USEV:
VOLUME:
The total Volume (VT) and Adjusted Volume (VA) of each model is tabulated below and may be for
use with the Energy-Guide Label Ratings.
VA = (VF x CRF) + VFF
CRF = dimensionless adjustment factor of 1.76 for Electric Refrigerator-Freezers (10 CFR, Part
430, Subpart B, App. A, Par. 6.1).
Note to Field Representative: See the General Instructions for Inspection of the Product in
Appendix A for advice regarding verification of a refrigerator’s volume.
ENERGY USE:
Annual Energy Consumption calculated per 10 CFR, Part 430, Subpart B, App. A.
+ - This is the energy consumption declared by the manufacturer. When
*tested per 10 CFR, Part 430, Subpart B, App. A, for this model the energy consumption was
approximately 263 kW-hr/Year with compressor B43C5B ,257 kW-hr/Year with compressor L48C5L ,
188kW-hr/Year with compressor MG1070HY and 270kW-hr/Year with compressor TK48C5.
++ – The maximum allowable energy use (kW-hr/Year) is based on the equations found in 10 CFR,
Chapter 2, Subpart C, Section 430.32 for Type 12. Compact refrigerator-freezers—partial automatic
defrost. For this model the maximum allowable energy use is calculated from the equation 5.91AV +
335.8, where AV is the total adjusted volume of the unit expressed in cubic feet. For this model
the maximum allowable energy use is 359 kW-hr/Year.
+++ - Estimated Annual Operating Cost is based on 16 CFR, Part 305, Appendix K and 10 CFR, Part
430, Par. 430.23. NOTE: The representative average unit cost of energy ($0.12/ kWhr, published
July 23, 2013) is based on information provided by the Secretary of the Department of Energy, and
may be revised annually.

File EV23684 Vol. 1 Sec. 36 Page 2A Issued: 2014-06-09
Annual Energy
Consumption
(kW-hr/Year)
(#)
Annual Energy
Consumption
Base Allowance
(kW-hr/Year)
(##)
Estimated Annual
Operating Cost
($/Year) (###)
BCD-90-E
(compressor
B43C5B,
L48C5L
,TK48C5
)
Type 12.
Compact
refrigeratorfreezers—
partial
automatic
defrost
BCD-90-E
(compressor
MG1070HY)
Type 12.
Compact
refrigeratorfreezers—
partial
automatic
defrost
and Report Revised: 2022-01-21
ENERGY USE:
# - This is the energy consumption declared by the manufacturer. When
*tested per 10 CFR, Part 430, Subpart B, App. A, for this model the energy
consumption was approximately 263 kW-hr/Year with compressor B43C5B , 257 kWhr/Year with compressor L48C5L ,188kW-hr/Year with compressor MG1070HY, and
270kW-hr/Year with compressor TK48C5.
*## – Annual Energy Consumption Base Allowance(kW-hr/Year) is based on the
equations found in ENERGY STAR Program Requirements Product Specification for
Residential Refrigerators and Freezers Eligibility Criteria Version 5.1-Table
1 for Type 12. Compact refrigerator-freezers—partial automatic defrost. For
this model Annual Energy Consumption Base Allowance is calculated from the
equation 5.32 * AV + 302.2, where AV is the total adjusted volume of the unit
expressed in cubic feet. For this model Annual Energy Consumption Base
Allowance is 323 kW-hr/Year.
### - Estimated Annual Operating Cost is based on 16 CFR, Part 305, Appendix
K and 10 CFR, Part 430, Par. 430.23. NOTE: The representative average unit
cost of energy ($0.12/ kWhr, published July 23, 2013) is based on information
provided by the Secretary of the Department of Energy, and may be revised
annually.

File EV23684 Vol. 1 Sec. 36 Page 3 Issued: 2014-06-09
(VFF)
Fresh Food
Compartment
Volume, L
(ft3)
(VF)
Freezer
Compartment
Volume, L
(ft3)
(VT)
Total
Refrigerated
Volume, L
(ft3)
(AV)
Adjusted
Volume, L
(ft3)
Annual Energy
Consumption
(kW-hr/Year) (+)
Max. Annual
Energy
Consumption (kWhr/Year) (++)
BCD-90-E
(compressor
B43C5B,L48C5L,
TK48C5)
Type 12 Compact
refrigeratorfreezers with
partial automatic
defrost
BCD-90-E
(compressor
B43C5B,L48C5L,
TK48C5
)
Type 12 Compact
refrigeratorfreezers with
partial automatic
defrost
BCD-90-E
(compressor
MG1070HY)
Type 12 Compact
refrigeratorfreezers with
partial automatic
defrost
and Report Revised: 2022-01-21
For CNEV:
VOLUME:
The total Volume (VT) and Adjusted Volume (AV) of each model is tabulated
below and may be for use with the Energy-Guide Label Ratings.
AV = Vfresh food + (Vfreezer × AF), VT = VFF + VF,AF=1.76 for refrigeratorfreezers.(CSA C300-15, Par. 8.5.2).
Note to Field Representative: See the General Instructions for Inspection of
the Product in Appendix A for advice regarding verification of a
refrigerator’s volume.
ENERGY USE:
+ - This is the energy consumption declared by the manufacturer. When
*tested per CAN/CSA C300-15, for this model the energy consumption was
approximately 224 kW-hr/Year with compressor B43C5B, 218kW-hr/Year with
compressor L48C5L , 188kW-hr/Year with compressor MG1070HY and 270kW-hr/Year with
compressor TK48C5.
*++ – The maximum allowable energy use (kW-hr/Year) is based on the equations
found in CAN/CSA C300-15, Table 2 for Type 12 Compact refrigerator-freezers
with partial automatic defrost. For this model the maximum allowable energy
use is calculated from the equation 5.91 AV + 335.8 , where AV is the total
adjusted volume of the unit expressed in cubic feet. For this model the
maximum allowable energy use is 359 kW-hr/Year.

File EV23684 Vol. 1 Sec. 36 Page 4 Issued: 2014-06-09
Range of Estimated Annual
Operating Costs
(Dollars/Year)
and Report
ADDITIONAL INFORMATION FOR ENERGYGUIDE LABEL USE:
Comments: This page is reserved for future use