For GE0500 - GE0630 - GE0800 - GE0500 T4 - GE0630 DT4 - GE0630 T4 - GE0800 DT4 - GE0800 T4
Direct operating version with handle GEX67ND Door coupling version with handle GEX67N - GEX67NB
30
(1.18”)
5
(0.20”)
11
190 (7.48”)
(0.98”)
max 470 (18.50”)121 (4.76”)
25
60 (2.36”)
6.5 (0.25”)
Ø
M10
Drilling
40 (1.57”)
Type A B C
GE0500 190 220 25
(7.48”) (8.66”) (0.98”)
GE0630 205 235 30
(8.07”) (9.25”) (1.18”)
GE0800 205 235 30
(8.07”) (9.25”) (1.18”)
GE0500 T4 190 220 25
(7.48”) (8.66”) (0.98”)
GE0630 DT4 205 235 30
(8.07”) (9.25”) (1.18”)
GE0630 T4 205 235 30
(8.07”) (9.25”) (1.18”)
GE0800 DT4 205 235 30
(8.07”) (9.25”) (1.18”)
GE0800 T4 205 235 30
(8.07”) (9.25”) (1.18”)
28 (1.10”)
Ø5.5
(0.22”)
143 (5.63”)
With terminal covers and auxiliary contact
200 (7.87”)
0
N
290 (11.42”)
GEX8121
(2 pcs/set)
(line)
GEX10 11
GEX8121
(2 pcs/set)
(load)
GEX7195N
GEX7345N
GEX7535N
14 (0.6”)
65 (2.56”)
42 (1.65”)
1...4
(0.04”....0.16”)
34 (1.34”)
11-32
Page 4
Switch disconnectors
0
0
0
Dimensions [mm (in)]
GE1000 - GE1250
325 (12.79”)
140 (5.51”)
75 (2.95”)75 (2.95”)
175 (6.89”)
30
(1.18”)
40
(1.57”)
6.5 (0.25”)
Ø
M14
250 (9.84”)
190 (7.48”)
290 (11.42”)
150 (5.90”)
For GE1000 - GE1250 - GE1000 T4 - GE1250 DT4 - GE1250 T4
Direct operating version with handle GEX68ND
GE1000 T4 - GE1250 T4
GE1250 DT4
150 (5.90”)175 (6.89”)
40
(1.57”)
N
250 (9.84”)
190 (7.48”)
290 (11.42”)
75 (2.95”)75 (2.95”)75 (2.95”)
325 (12.79”)
140 (5.51”)
30
(1.18”)
6.5 (0.25”)
Ø
M14
Not indicated on GE... DT4 type.
11
396 (15.59”)
Door coupling version with handle GEX68N - GEX68NB
30
(1.18”)
190 (7.48”)
8
(0.31”)
GEX7 195
GEX7 345
GEX7 535
14 (0.6”)
max 470 (18.50”)137 (5.39”)
42 (1.65”)
1...4
(0.04”....0.16”)
60 (2.36”)
With terminal covers and auxiliary contact
300 (11.81”)
0
GEX8131
(2 pcs/kit)
(line)
GEX10 11
Drilling
40 (1.57”)
28 (1.10”)
34 (1.34”)
Ø5.5
(0.22”)
75 (2,95”)
N
340 (13.38”)
GEX8131
(2 pcs/kit)
(load)
11-33
Page 5
Switch disconnectors
Dimensions [mm (in)]
GE1600GE1600 T4
209 (8.23”)232 (9.13”)
255 (10.04”)
441 (17.36”)
”)
Ø14.1
(0.55
Ø11 (0.43”)
O
36
100 (3.94”)100 (3.94”)
(1.42”)
60
(2.36”)
40
(1.57”)
Direct operating version with handle
GEX68ND
11
200 (7.87”)
209 (8.23”)
60
(2.36”)
4”)
Ø16.2
(0.6
381 (15”)
330 (12.99”)
255 (10.04”)
N
Door coupling version with handle
GEX68N - GEX68NB
50
(1.97”)
162 (6.38”)
10
(0.39”)
441 (17.36”)
O
100 (3.94”)100 (3.94”)
max 483 (19.01”)
Ø14.1
232 (9.13”)
5”)
(0.5
36
(1.42”)
Ø11 (0.43”)
60
(2.36”)
40
(1.57”)
330 (12.99”)
441 (17.36”)
396 (15.59”)
With terminal covers and auxiliary contact
410 (16.14”)
O
N
255 (10.04”)
472 (18.58”)
60
(2.36”)
GEX81 31
(2 pcs/kit)
(line)
GEX10 11
240 (9.45”)
GEX7 239N
GEX7 485N
14 (0.6”)
104 (4.09”)
(1.65”)
1...4
(0.04”...0.16”)
42
60
(2.36”)
Drilling
40 (1.57”)
28 (1.10”)
34 (1.34”)
Ø5.5
(0.22”)
11-34
GEX81 31
(2 pcs/kit)
(load)
Page 6
Switch disconnectors
Dimensions [mm (in)]
GE SERIES - 50A TO 800A SWITCH DISCONNECTORS WITH FUSE HOLDER
GE0050 F with auxiliary contact
5.4 (0.21”)
GEX10 11N
GE0050 FT4 with auxiliary contact
5.4 (0.21”)
GEX10 11N
GEX10 11N
76 (2.99”)
124 (4.88”)
104 (4.09”)
31 (1.22”) 31 (1.22”)
52 (2.05”)
114 (4.49”)
GE0125 F with auxiliary contact
104 (4.09”)
145 (5.71”)
132 (5.20”)
5.4 (0.21”)
37
(1.46”)37(1.46”)
58 (2.28”)
GEX10 11N
For GE0050 F - GE0050 FT4 - GE125 F - GE125 FT4
Direct operating version with handle GEX61D
49 (1.93”)
N
124 (4.88”)
104 (4.09”)
31 (1.22”)31 (1.22”)
GE0125 FT4 with auxiliary contact
N
104 (4.09”)
145 (5.71”)
37
(1.46”)37(1.46”)37(1.46”)
184 (7.24”)
31 (1.22”)
145 (5.71”)
169 (6.65”)
5.4 (0.21”)
52 (2.05”)
58 (2.28”)
GEX10 11N
GEX10 11N
121 (4.76”)
131 (5.16”)
28
(1.10”)
28
(1.10”)
(0.24”)
(0.24”)
130 (5.12”)
6
76 (2.99”)
150 (5.90”)
11
6
GEX6 1D
95 (3.74”)
For GE0050 F - GE0050 FT4 - GE125 F - GE125 FT4
Door coupling version with handle GEX61N - GEX61NB
49 (1.93”)
26.5
(1.04”)
84.5 (3.33”)95 (3.74”)
22.5
(0.88”)
GEX61N
GEX61NB
Drilling
56 (2.20”)
28 (1.10”)
34 (1.34”)
34
(1.34”)
Ø5.5
(0.22”)
45
(1.77”)
(1.06”)
27
GEX61N
GEX61NB
13
(0.51”)
max 281
(11.06”)
max 402 (15.83”)
GEX7162N
GEX7250N
GEX7387N
7 (0.3”)
34
(1.34”)
11-35
Page 7
Switch disconnectors
(
)
Dimensions [mm (in)]
GE0160 N with auxiliary contact
152 (5.98”)
5.4 (0.21”)
170 (6.69”)
147 (5.79”)
104 (4.09”)
37
37
(1.46”)
(1.46”)
For GE0160 N - GE0160 NT4
Direct operating version with handle GEX61D
GEX10 11N
49 (1.93”)
11
58 (2.28”)
GEX6 1D
GEX10 11N
GE0160 NT4 with auxiliary contact
N
170 (6.69”)
147 (5.79”)
104 (4.09”)
37
37
(1.46”)
(1.46”)
184 (7.24”)
GEX10 11N
169 (6.65”)
5.4 (0.21”)
(1.46”)
76 (2.99”)
170 (6.69”)
GEX10 11N
37
58 (2.28”)
GEX10 11N
131 (5.16”)
34
(1.34”)
76 (2.99”)
6.69”
170
95 (3.74”)
For GE0160 N - GE0160 NT4
Door coupling version with handle GEX6 1 - GEX6 1B
49 (1.93”)
26.5
(1.04”)
Terminal covers GEX82 01 for GE0160 N
(1.38”)
22.5
(0.88”)
95 (3.74”)84.5 (3.33”)
GEX61N
GEX61NB
Terminal covers GEX82 03 for GE0160 NT4
35
GEX82 01
(line)
Drilling
56 (2.20”)
28 (1.10”)
34 (1.34”)
35
(1.38”)
34
(1.34”)
Ø5.5
(0.22”)
GEX82 03
(line)
GEX61N
GEX61NB
45
(1.77”)
(1.06”)
GEX82 01
GEX82 03
(line)
max 402 (15.83”)
GEX7162N
GEX7250N
GEX7387N
7 (0.3”)
max. 271
27
(10.67”)
34
(1.34”)
55 (1.38”)
11-36
N
GEX82 01
(load)
GEX82 03
(load)
GEX82 01
GEX82 03
(load)
299 (11.77”)
Page 8
Switch disconnectors
Dimensions [mm (in)]
GE0161 N
with terminal covers and auxiliary contact
C
D
42
(1.65”)
200 (7.87”)
88 (3.46”)
GEX10 11
M8
117.5 (4.62”)
25
(0.98”)
22
82.5 (3.25”)
(0.87”)
For GE0161 N - GE0161 NT4
Direct operating version with handle GEX62D
133 (4.13”)
5.5
Ø
18
(0.71”)
45 (1.77”)
(0.22”)
131 (5.16”)
150 (5.90”)
168 (6.61”)
192 (7.56”)
GE0161 NT4
with terminal covers and auxiliary contact
239 (9.41”)
45
88 (3.46”)
GEX10 11
M8
117.5 (4.62”)
25
(0.98”)
45 (1.77”)
18
(0.71”)
Ø5.
5
(0.22”)
22
(0.87”)
C
N
D
42 (1.65”)
121.5 (4.78”)
(1.77”)
Door coupling version with handle GEX66N - GEX66NB
and terminal covers
39
(1.53”)
3 (0.12”)
131 (5.16”)
150 (5.90”)
168 (6.61”)
192 (7.56”)
11
105 (4.13”)
TYPE C (line) D (load)