Module for auxiliary contacts mounting on the side of the
switch mechanism.
GMX3 3 For GMF..030 types 1 0.060
GMX3 4 For GMF...60 to GMF...800 types 1 0.065
Terminal covers.
GMX8 00 3-piece set, each covers 1 pole 1 0.080
for GMF J100 C03
GMX8 01 3-piece set, each covers 1 pole 1 0.090
for GMF J200 C03
GMX8 02 1-piece set, covers 3 poles for 1 0.080
for GMF J400 C03
GMX8 03 1-piece set, covers 3 poles for 1 0.080
for GMF J600 C03
GMX8 04 1-piece set, covers 3 poles for 1 0.080
for GMF L800 C03
Terminal clamp sets for rigid and flexible cables.
GMX5 00 6-piece set for GMF J100 C03 1 0.200
GMX5 01 6-piece set for GMF J200 C03 1 0.200
GMX5 02 6-piece set for GMF J400 C03 1 0.500
GMX5 03 6-piece set for GMF J400 C03 1 1.000
GMX5 04 6-piece set for GMF J600 C03 1 1.600
and GMF L800 C03
Fuse monitor modules .
GMXF M1 Rated voltage 120...240V 1 0.145
GMXF M2 Rated voltage 380...600V 1 0.140
Crimp terminals for fuse monitor GMXF.... cables.
GMX5 05 6-piece set. Terminal size 1 0.004
2.8-0.8mm/0.11-0.03in.
Command
pole
per
position
pkg
Central
1 0.700
Central
Central
1 1.135
Left
1 1.135
Left
1 1.815
Left
1 3.000
Left
1 6.800
Left
1 13.00
Left
1 13.00
rating at
600VAC
Qty Wt
1 0.700
[class]
General characteristics
– General purpose current according to UL98:
30A to 800A
– Compact dimensions
– Available versions: direct operating and door coupling
– Screw or 35mm DIN rail fixing for GMF...030 types
– Possibility to adjust the position of the clips for fixing
screw on plate for GMF..060 to GMFL800 types.
Operational characteristics
– IEC rated insulation voltage Ui: 1000V
– UL max operating voltage: 600V
– IEC rated impulse withstand Uimp: 12kV
– Mechanical life:
• 10,000 cycles for GMF..030 and GMF..060
• 8,000 cycles for GMF J100 C03 and GMF J200 C03
• 5,000 cycles for GMF J400 C03 and GMF J600 C03
• 3,000 cycles for GMF L800 C03.
Certifications and compliance
Certifications obtained: cULus according to UL98 /
CSA C22.2 n°4.
Compliant with standards: IEC/EN 60947-3, IEC/EN 60947-1.
GMF...C12 type
Central command pole
ON
O
F
F
Operational characteristics of auxiliary contacts GMX10 11
– IEC conventional free air thermal current Ith: 10A
– IEC rated insulation voltage: 400V
– Conductivity: 12V, 25mA
– Tightening torque: 0.8Nm/7.1lb.in
– Maximum 6 contacts for GMF..030 disconnect switches.
Operational characteristics of auxiliary contacts GMX10 10/01
– IEC/UL conventional free air thermal current Ith: 16A/10A
– IEC/UL rated insulation voltage: 690V/600V
– Conductivity: 24V, 10mA
– UL/CSA and IEC/EN 60947-5-1 designation: A600 R300
– Tightening torque: 0.8Nm/7.1lb.in
– Maximum 8 contacts for GMF...060 to GMF L800
disconnect switches.
Operational characteristics for terminal clamps
– Minimum and maximum conductor cross section:
• GMX5 00: 2.5...70mm
• GMX5 01: 25...150mm
• GMX5 02: 35...300mm
• GMX5 03: (2)x 35...600mm
• GMX5 04: (2)x 35...600mm
– Tightening torque:
• GMX5 00: 5.5Nm / 50lb.in.
• GMX5 01: 8Nm / 72lb.in
• GMX5 02: 27Nm / 240lb.in
• GMX5 03: 8Nm / 72lb.in
• GMX5 04: 54Nm / 480lb.in
Operational characteristics for terminal covers
– Snap on mounting.
Certifications and compliance
Certifications obtained: cULus for GMX10 10, GMX10 01,
GMXF M1 and GMXF M2.
Compliant with standards: IEC/EN 60947-3, IEC/EN 60947-1.
GMF...C03 type
Left command pole
O
F
F
2
/ 14-2AWG
2
/ 4-300Kcmil
2
/ 2-600Kcmil
2
/ (2x) 4-300Kcmil
2
/ (2x) 2-600Kcmil
ON
2
Dimensions
page 4 and 5
Wiring diagrams
page 5
Technical characteristics
page 6
Page 3
Fusible disconnect switches (UL98)
I
I
I
I
I
I
I
I
I
I
GM series 30A to 800A
Accessories
Handles and shafts
GMX62 DB
GMX62
GLX00
GMX7...S06
new
new
new
new
new
Order Characteristics Qty Wt
code per
pkg
n° [kg]
Direct operating handles.
GMX61 DB For GMF...030. Black 1 0.050
GMX62 DB
Black
GMX63 DB For GMF J400. Black 1 0.350
GMX64 DB
NEMA 4, 4X. Black
Flexible connection cables for GMX61 NFPA.
GMXC L36 Cable length 914mm/36in. 1 0.400
GMXC L48 Cable length 1220mm/48in. 1 0.500
GMXC L60 Cable length 1520mm/60in. 1 0.550
GMXC L72 Cable length 1828mm/72in. 1 0.650
Support and operating mechanism for GMX61 NFPA.
GMX3 0 For GMF...030 1 0.830
GMX3 1 For GMF J060 C12 1 1.180
GMX3 2 For GMF...060...GMF J200 1 1.520
Dimensions
page 4 and 5
Wiring diagrams
page 5
General characteristics for NFPA handle
The GMX61 NFPA lever handle complies with the
requirements of the North American NFPA79 standard.
This standard requires that the switch disconnector can be
operated without accessories or tools whether the door is
closed or open. In case of operation with an open door, a
device is integrated into the GMX61 NFPA handle to prevent
it from being activated unless a voluntary action is taken to
unlock it.
Certifications and compliance
Certifications obtained: cURus for GMX61 NFPA.
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-3.
Technical characteristics
page 6
3
Page 4
Fusible disconnect switches (UL98)
B
GM series 30A to 800A
Dimensions [mm(in)]
GMF...030 C12
38 (1.5”)
14.3
(0.56”)
30.8 (1.21”)
106 (4.17”)
GMF J060 C12
91.5 (3.60”)
55.5
(2.18”)
ON
O
F
F
71.5 (2.81”)
147.5 (5.81”)
GMF J100 C03
17.5
(0.69”)
95.5 (3.76”)
46
(1.81”)
ON
O
F
F
4.5 (0.18”)
36
(1.42”)
53.3
(2.10”)
(1.09”)
35
(1.38”)
27.6
8.5
(0.33”)
75...80
(2.95”...3.15”)
M5
33.4
(1.31”)
20
(0.79”)
35
(1.38”)
97 (3.82”)
85 (3.35”)
113 (4.45)”)
GMF J060 C03
(1.87”)
17.5
(0.69”)
57 (2.44”)
ON
O
F
F
100 (3.94”)
M5
11 (0.43”)
220 (8.66”)
172 (6.77”)
47.5
36
(1.42”)
46
(1.81”)
60 (2.36”)
36 (1.42”)
93 (3.66”)
95 (3.74”)
104 (4.09”)
35
(1.38”)
145 (5.71”)
81 (3.19”)
69 (2.72”)
287...437 (11.30”...17.20”)
min. 14 (0.55”)
112 (4.41”)
287...437 (11.30”...17.20”)
2.5 (0.10”)
GMX7...S06
min. 14 (0.55”)
287...437 (11.30”...17.20”)
118 (4.6 4”)
125.5 (4.94”)
138.5 (5.45”)
65 (2.56”)
GAX66N-GAX66NB
100 ((3.94”)
65 (2.56”)
GAX66N-GAX66NB
M5
GMF J200 C03
20
(0.79”)
(1.57”)
M5
ON
72 (2.83”)
O
F
F
126 (4.96”)
33.5
(1.32”)
48.5
(1.91”)
4
(1.81”)
40
46
(1.38”)
146.5 (5.77”)
8.6
(0.34”)
46
(1.81”)
181.5 (7.14”)
35
20
(0.79”)
8.4
(0.33”)
10 (0.39”)
164.5 (6.48”)
110
(4.33”)
5.5
3
(0.12”)
218 (8.58”)
36.5
(0.22”)
(1.44”)
198.5 (7.81”)
(1.93”)
38
(1.50”)
59 (2.32”)
49
104.5 (4.11”)
75 (2.95”)
40.5
(1.59”)
(0.12”)
132 (5.20”)
min. 14 (0.55”)
3
GAX66N-GAX66NB
min. 14
(0.55”)
287...437 (11.30”...17.20”)
65 (2.56”)
GAX66N-GAX66N
159 (6.26”)
65 (2.56”)
Page 5
Fusible disconnect switches (UL98)
GM series 30A to 800A
Dimensions [mm(in)]
GMF J400 C03
82 (3.23”)
(2.30”)
11.5
(0.45”)
75.5
(2.97)
58.5
64
(2.52”)
255 (10”)
7.5
28
(1.10”)
M5
140 (5.51”)
GMF J600 C03 - GMF L800 C03
13.5 (0.53”)
6
(0.24”)
36.5
(1.44”)
M8
(0.29”)
20
(0.79”)
10.8
(0.42”)
25
(0.98”)
193 (7.60”)
39
(1.53”)
55.8 (2.20”)
5
(0.20”)
230 (9.05”)
43.5
(1.71”)
81 (3.19”)
(0.20”)
5
40
(1.57”)
176 (6.93”)
min 20 (0.79”)
265...415 (10.43”...16.34”)
142 (5.59”)
48.4
(1.90”)
5
(0.20”)
6
(0.24”)
50
GMX61-GMX61B
(1.97”)
194 7.64”)
125 (4.92”)
GMX62-GMX62B
77.5 (3.05”)
95 (3.74”)
Wiring diagrams
GM..030 .. GMF L800
LINE
L2
L1
T1 T2L3T3
LOAD
88 (3.46”)
343 (13.50”)
254 (10”)
230 (9.05”)
266 (10.47”)
306 (12.04”)
13
(0.51”)
233 (9.17”)
290...640 (11.42”...25.20”)
min 20 (0.79”)
Auxiliary contacts
GMX10 10GMX10 01GMX10 11
3
4
1
2
175 (6.89”)
32
1
5
Page 6
Fusible disconnect switches (UL98)
GM series 30A to 800A
Technical characteristics
TECHNICAL DATA ACCORDING TO IEC/EN 60947
TYPE 3-pole GMF...030… GMFJ060… GMFJ100C03 GMFJ200C03 GMFJ400C03 GMFJ600C03 GMFL800C03
CONTACT CHARACTERISTICS
IEC conventional free air A 32 63 160 200 400 630 800
thermal current Ith (≤40°C)
IEC rated insulation voltage V 1000
Ui
IEC rated impulse voltage kV 12
withstand Uimp
IEC rated operational current Ie
AC21A 400V A 32 63 160 200 400 630 800
500V A 32 63 160 200 400 630 800
690V A 32 63 160 200 400 630 800
AC22A 400V A 32 63 160 200 400 630 800
500V A 32 63 160 200 400 630 800
690V A 32 63 160 200 400 630 800
AC23A 400V A 32 63 160 200 400 630 800
500V A 32 63 160 200 400 630 800
690V A 32 63 160 200 400 630 800