Louroe ASK-4 # 101-C Installation And Operating Insctruction Manual

ASK-4® # 101-C
AUDIO MONITORING SYSTEM
INSTALLATION AND OPERATING INSTRUCTIONS
ASK-4® # 101-C - (LE-362)
The ASK-4® 101-C is a single zone audio monitoring system designed to interface with a DVR, VCR or other recording devices that accept line level input. The APR-1 Audio Base Station contains a built-in 3” speaker and volume control for producing live audio and audio playback. The
Verifact™ “C” is an omnidirectional pre-amplied microphone that produces line level output. The microphone is extended 3’ long designed for
mounting in special or customized housing.
KIT CONTENT
PRODUCT NAME DESCRIPTION
APR-1
(LE-146)
Verifact™ “C” Mic
(LE-072)
AD-1
(LE-242)
Dual RCA Cable RCA cable for connection to a DVR/VCR or other Audio devices that accept line level input.
listed Audio Base Station. Used for listening to live audio from microphone, as well as
audio playback from DVR’s, VCR’s or other audio devices.
Line Level, Electret condenser microphone with preamp. Picks up normal sounds within 30’ circle. May be located Up to 1000’ from APR-1 Base Station.
listed AC ADAPTER. Supplies 12 Vdc to APR-1 and Microphone.
PART DESCRIPTION
[1] Power-Volume
[2] Power Indicator
[3] Mute Indicator
[4] Playback
Indicator
[5] Overload
Indicator
[6] Mute Switch
[7] Push for play-
back
[8] Headphone
Jack
[9] Speaker (3”)
[10] Power Jack
[11] Audio in Jack
(RCA)
[12] Audio Out Jack
(RCA)
[13] Audio Terminal
Block
Turns “ON” power to the unit and controls the audio volume through the
Speaker[9]
.
Lights (green) when the power is present to the unit.
Lights (orange) when Mute
Switch[6]
is pushed in.
Audio is muted.
Lights (yellow) when Push for
Playback[7]
is
pushed in to “ON” position.
Flashes (red) when there is a short in the power sup-
Used to mute the audio on both live and playback
Used for DVR/VCR playback. May also be used to listen to audio from an external source. Press switch to listen to playback. Switch must be “OUT” or “OFF” when monitoring and recording, otherwise live audio is muted
Used for private listening. Any 3.5mm stereo
headphone with 8Ω to 600Ω impedance can be
used.
Provides live audio. Muted when a headphone is connected to Headphone Jack [8].
Accepts 12Vdc power from Model AD-1 Power Sup­ply (included with APR-1 Audio Base Station).
Accepts audio playback from an external source
(DVR/VCR). Audio playback is produced through
the speaker. The Push for Playback
[7]
must be “IN”
during audio playback and “OUT” when not used for
Provides audio output and connection to a DVR, VCR, etc.
A 3-pin terminal block marked A, B, C. Accepts wiring
from the remote Louroe™ Microphone.
A is 12Vdc
B is Audio
C is Ground
[1] Power-Volume [2] Power Indicator
[3] Mute
[4] Playback Indicator
[5] Overload Indicator
[10] Power Jack [12] Audio Out Jack (RCA)
PWR
MUTE
APR-1
PLAYBACK
MUTE
OVERLOAD
SINGLE ZONE AUDIO BASE STATION
[6] Mute Switch
[7] Push for Playback
MIC INPUT
INPUT+12Vdc
[11] Audio In Jack
PUSH FOR PLAYBACK
[8] Headphone Jack
OUTPUT
APR-1 (LE-146)
[9] Speaker
MIC INPUT
A B C
[13] Audio Terminal Block
6955 VALJEAN AVE. VAN NUYS, CA 91406 PH: 818-994-6489 | FAX: 818-994-6485 | TECHSUPPORT@LOUROE.COM | WWW.LOUROE.COM
INTERCONNECTION DIAGRAM
VERIFACT™ “C” MICROPHONE TO APR-1 BASE STATION TO DVR, ETC..
WIRING REQUIREMENTS
Both the Verifact™ “C” Microphone and APR-1 Audio Base Station contain a 3-pin terminal block marked A, B, C
2 Conductor shielded cable, 22 gauge with a 24 gauge drain wire.
NOTE: Unshielded cable is not satisfactory for audio systems
NOTE: If DVR’s audio input and output are 3.5mm (mini jack) type, use
the appropriate adapter at one end of RCA patch cable for connection.
Check with manufacturer’s specications to determine id 3.5, audio
input/output is mono or stereo.
ASK-4® # 101-C
AUDIO MONITORING SYSTEM
INSTALLATION AND OPERATING INSTRUCTIONS
VERIFACT “C” (LE-072)
A B C
Terminal block Identier
for Microphone
(A) Red - 12Vdc power (B) Black - Audio Output (C) Bare - Ground
AD-1 AC Adapter (LE-242)
+12Vdc
[10]
APR-1 (LE-146)
(Back Panel)
MIC INPUT
OUTPUT
INPUT
[12]
[11]
“Audio IN” of APR-1 Connects to “Audio OUT” of DVR or other receiving device
A B C
[13]
“Audio OUT” of APR-1 connects to “Audio IN” for DVR or other receiving device
6955 VALJEAN AVE. VAN NUYS, CA 91406 PH: 818-994-6489 | FAX: 818-994-6485 | TECHSUPPORT@LOUROE.COM | WWW.LOUROE.COM
Audio IN Audio
Rear Panel of DVR with RCA Type Aduio Input
ASK-4® # 101-C
AUDIO MONITORING SYSTEM
INSTALLATION AND OPERATING INSTRUCTIONS
SENSITIVITY SWITCH OF VERIFACT™ “C” MICROPHONE
For special installations that require less microphone sensitivity or where there is background noise, a sensitivity switch is mounted to the microphone pre-amp (PC Board) and has two positions, N and L:
• N represents normal sensitivity (0dB ouput into 1kΩ)
• L represents low sensitivity (-6dB output into 1kΩ)
Louroe VERIFACT™ microphones are always shipped with the sensitivity switch in normal (N) position. Do not change unless necessary. To change the sensitiv­ity setting, use a small screwdriver and move slide switch from N to L position. The switch is mounted on the back side of the microphone housing.
NOTE REGARDING INTERFACING ASK-4 KIT #101 WITH A DVR OR PC SOUNDCARD
The APR-1 Audio Base Station of ASK-4 Kit #101 is compatible with all commercial
DVR’s and PC Soundcards that accept line level input (0dB@600Ω). An RCA cable is included with the kit for connecting Audio Out to Audio In of DVR. If DVR’s audio input is a 3.5mm jack, an RCA to 3.5mm adapter (not supplied) must be attached to the plug that connects to DVR’s Audio Input. Check with DVR’s specications to
determine if the audio input requires a stereo or mono 3.5mm plug.
PC soundcards contain a standard 3.5mm stereo Audio Input or Line Input. Do not
use Mic Input of soundcard. Louroe microphones are line level (0dB@600Ω) and will
overdrive the Mic Input. Use “Audio Input” or Line Input” of the soundcard.
WIRING CONNECTIONS AND TEST
1. Starting with the microphone, connect RED wire to Pin A, BLACK wire to Pin B and BARE wire to Pin C. Connect other end of cable to Terminal Block on back panel of APR-1 Base Station matching RED wire to Pin A, BLACK wire to Pin B and BARE wire to Pin C. Refer to drawing on page 2.
2. Plug AD-1 power supply (AC Adapter) into the Power Jack[10] located
on back panel of APR-1 rst. Then connect 2- prong block into standard
110/120 AC wall receptacle or power strip.
3. Turn “ON” power to APR-1 by rotating the wise. The green PWR[2] LED will illuminate. Adjust volume of audio by rotat- ing the knob either clockwise to increase or counterclockwise to decrease. Locate microphone so as not to create feedback with the APR-1. The further the microphone is from the APR-1 the less feedback it generates. System works best if there is an acoustical barrier between the microphone and the APR-1, such as a wall or room divider. If there is no wall or barrier, microphone should be mounted at least 25 ft. from the APR-1 Base Station.
4. Plug headphone into the Headphone Jack[8]. Speaker[9] output is muted and sound is transmitted through the headphone.
5. Using the dual RCA cable (supplied), connect DVR/VCR’s AUDIO OUT jack to APR-1’s AUDIO IN
6. Connect DVR/VCR’s AUDIO IN jack to APR-1’s AUDIO OUT
7. Press “REC” on the recording device and record live audio for several minutes.
8. Press Push for Playback LED[4] will illuminate yellow.
9. Press “PLAY” on the DVR/VCR to playback recorded audio from the APR-1.
Jack[11].
Switch[7]
Power-Volume
to “ON” position. Playback
Knob[1] clock-
Jack[12]
Indicator
INSTALLATION TIPS
1. Use overall shielded audio cable only. West Penn 452, Belden 8451 or equivalent. UNSHIELDED CABLE IS NOT SATISFACTORY FOR SOUND SYSTEMS.
2. When used in cashier’s booth, microphon should be installed
closer to the customer rather than the cash register, as the drawer sound may dominate the recording. It should be installed clos­est to the area that needs to be monitored and documented.
3. Avoid installing microphone near air vents, air conditioner, fans and
other equipment that generate high sound and air pressure.
4. If using a VCR, it may have both intermittent and constant speed
playback. See VCR’s manual on how to select constant speed.
5. The APR-1 and microphone should have a barrier or solid wall between
them in order to avoid audio feedback, especially when they are in close proximity to each other up to 25’ (7.6 m). WIRING CONNEC-
TIONS AND TEST
SPECIFICATIONS
VERIFACT™ “C” (LE-072)
Type
Output Line Level 0 dB @ 1KΩ,
Frequency Response 40 Hz to 15 kHz ± 1 dB
Current Drain
Supply voltage 12Vdc
Dimensions 4”Dia x 1 ½”H
APR-1 (LE-146)
Input sensitivity (mic)
Monitor output power
Audio line output impedance
Audio input impedance
Freq. response 100 Hz to 10 kHz
Headphone impedance 8 to 600Ω
Universal power supply 12 Vdc, 500 mA
Dimensions
Weight (shipping)
Electrect Condenser
unbalanced
4 mA
0.78V
1W@8Ω
600Ω or higher
10K
8 ¼”L x 5 ¾”W x 1 ⅜”H
4 lbs. (1.8)Kg
10. Press Mute LED[3] will light and no audio can be heard on the speaker on both live and playback audio. When Mute will not light even when the Push for Playback the audio is muted.
Switch[6]
to mute audio heard on the speaker. Mute
Switch[6]
is ON Playback
Switch[7]
Indicator
Indicator
is pushed in and
LED[4]
ASK-4® # 101-C
AUDIO MONITORING SYSTEM
INSTALLATION AND OPERATING INSTRUCTIONS
WARRANTY
LOUROE ELECTRONICS® warrants that at the time of shipment products manufactured by LOUROE ELECTRONICS® to be free of defects in material and workmanship. Should a defect appear within one year (12 months) from date of shipment, LOUROE ELECTRONICS will, at its sole discretion, repair or replace the defective equipment. This equipment shall not be accepted for
repair or return without prior notication by LOUROE ELECTRONICS®.
This warranty does not extend to any Louroe product that has been subjected to improper or incorrect installation, misuse, accident, or in violation of instal­lation instructions provided by LOUROE ELECTRONICS®.
Returned shipments to LOUROE ELECTRONICS® shall be at customer’s expense. LOUROE ELECTRONICS® will return the equipment prepaid via best way.
ABOUT LOUROE ELECTRONICS
Located in Van Nuys, California and 32 years young, Louroe Electron­ics™ has been the world leading Audio Manufacturer. Our continued growth has resulted from providing innovative products, receiving high customer satisfaction, maintaining strict devotion to quality standards and following the law in Federal, State and Municipal Jurisdiction.
Our “Verifact” line of amplified microphones, complementing base sta­tions, and communication accessories, provide line level output to inter­face with various digital electronics. Our products are compatible with a wide range of digital video recorders, video cassette recorder, Internet Protocol Network video systems, video servers and computer based re­corders.
We are recognized worldwide for our variety of audio monitoring technol­ogy. Our products are used in over twenty countries and are utilized in both the private sector and government applications. We currently serve the needs of law enforcement, security, health care, entertainment, hos­pitality and retail industries and many more. At Louroe Electronics we maintain rigorous standards to ensure our products provide reliability, durability and excellent performance for our customers’ needs. We are proud to continue designing, engineering and manufacturing at our headquarters base in Van Nuys, California.
IMPORTANT NOTICE
When this equipment is used as part of an audio moni­toring system, the law requires that the public be given notice of AUDIO MONITORING ON THE PREMISES. A decal notice is included with each microphone shipped.
FEDERAL LAW REFERENCES: Federal Regulations, US Code, Title 18. Crime and Criminal Procedure, Sec 2510.
MADE IN U.S.A
WORLD LEADER IN AUDIO MONITORING TECHNOLOGY
6955 VALJEAN AVE. VAN NUYS, CA 91406 PH: 818-994-6489 | FAX: 818-994-6485|
TECHSUPPORT@LOUROE.COM | WWW.LOUROE.COM
Loading...