Models AP-2 is a non-alarming audio monitoring base stations for providing 2 audio zones. The unit has the same
amount of audio outputs (RCA) as it does for microphone inputs. Model AP-2 will accommodate two Louroe Microphones
and has two line level audio outputs. It contains a built-in speaker for producing live audio and audio playback from a
DVR. In addition, it has a selectable RCA audio output for interfacing with a DVR with only one audio input, or with a
VCR. Zone selection is by pushbutton. Contains a Mute switch that mutes the audio of the remote microphones from
being heard at unit’s speaker. All Louroe microphones are compatible with the AP-2.
2 ZONE AUDIO BASE STATION
Dual RCA Cable
AD-1 Power Supply
ContentsDescription
U
AP-2 listed 2 Zone Audio Base Station.
Used for listening to live audio
AD-1 listed AC ADAPTER.
Dual RCA CableRCA cable for connection to a
®
from microphone, as well as
audio playback from DVR’s, VCR’s
or other audio devices.
U
®
Supplies 12 Vdc to APR-1 and
Microphone.
DVR/VCR or other Audio devices
that accept line level input
(0dB @ 600W).
LOUROE ELECTRONICS 6 9 5 5 VALJEAN AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
®
website: www.louroe.com e-mail: sales@louroe.com
Page 1 of 8
(818)
AP_2_inst_2/15
INSTALLATION AND OPERATING INSTRUCTIONS
4
5
2
3
Fig. 1 Front of AP-2
DESCRIPTION AND FUNCTION OF PARTS
[1] - Play/Mute SwitchUsed when playing back audio from a recorder or mute the audio
from the microphone. No audio is heard on the Speaker[7] when
this switch is ON.
[2] - Zone Selector SwitchesSelect zone for monitoring. Press switch of desired zone to listen
to live audio. Pressing more than one zone is possible when it is
necessary to monitor more than one zone at a time, but audio
may be difficult to understand if there is audio activity at several
zones. Zone switches light blue when press indicating active
zone.
[3] - Headset JackUsed for private listening. Any stereo headset with 8 to 600W
impedance maybe used. Mutes speaker output when use.
[4] - Power IndicatorLights (green) when power is turned ON.
[5] - Power-Volume KnobRotating knob clockwise turns ON power to the unit as indicated
by the Power Indicator[4] light. Rotating further clockwise
increases the volume of the monitored audio as heard through
the Monitor Speaker[7].
1
LOUROE ELECTRONICS 6 9 5 5 VALJEAN AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
®
website: www.louroe.com e-mail: sales@louroe.com
Page 2 of 8
(818)
AP_2_inst_2/15
INSTALLATION AND OPERATING INSTRUCTIONS
7
6
9
8
Fig. 2 Rear view of AP-2
11
DESCRIPTION AND FUNCTION OF PARTS
[6] - Mic Input 3-Pin Terminal BlockConnects to remote Louroe microphones.
[7] - Monitor SpeakerProvides live audio through the 3” built-in speaker. Muted when
a headset is connected to Headset Jack[3].
[8] - Audio In Jack (RCA)Receives audio playback from DVR/VCR, etc. and is broadcast
through the built-in speaker. [7].
[9] - Audio Out Jack (RCA)Provides audio to DVR/VCR for recording or to other audio
devices accepting line level input when any of the Zone Selector
Switches[2] are activated or push in. The audio output to this
jack will be the audio selected by the Zone Selector Switches[2].
[10]- Power JackAccepts 12Vdc from external power supply (included)
10
[11] - Mic Output JackUsed for connection to a DVR with multiple audio inputs or to a
LOUROE ELECTRONICS 6 9 5 5 VALJEAN AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
®
website: www.louroe.com e-mail: sales@louroe.com
soundcard module for audio recording. May also be used for
paralleling to a second Louroe audio base station.
(818)
Page 3 of 8
AP_2_inst_2/15
INSTALLATION AND OPERATING INSTRUCTIONS
MICROPHONE CONNECTIONS TO AP-2
All Louroe Verifact Microphones contain a 3-pin terminal block marked A, B, C. All Louroe base stations contain similar
3-pin terminal blocks marked A, B, C. Refer to interconnection diagram p 5. Using sample cable:
1) Take one end of recommended cable to first microphone location and connect:
2) Run other end of cable to the AP-2 Base Station location and connect to the Mic Input 3-Pin Terminal Block
3) Repeat the same procedure for the remaining microphones using the additional terminal blocks marked zone
CONNECTING AP-2 TO A RECORDING DEVICE (DVR, ETC.)
A) If connecting to a DVR with one audio input:
®
A = 12Vdc Power (red wire)
B = Audio Output (black wire)
C = Common Ground (bare wire)
Red wire to terminal A (12Vdc)
Black wire to terminal B (Audio Output)
Bare wire to terminal C (Ground)
[6]
of the audio zone in which the remote microphone is assigned (example zone 1). Again connect Red wire to
Pin A, Black wire to Pin B and Bare wire to Pin C.
2, zone 3, etc.
1) Connect an RCA cable to the Audio Out jack [9] of AP-2 and connect other end to Audio In (or line in)
of VCR/DVR
2) To record a particular zone, press the Zone Selector Switch [2] located on front panel of base station
for the audio zone to be recorded
3) For audio playback, connect another RCA cable from Audio Out (or line out) of VCR/DVR to Audio In
[8] of AP-2.
4) Press in the Mute/Playback button[1] of front panel
5) Press the play or playback button on VCR/DVR to start audio playback. Playback will be broadcast
through the base station’s built-in Monitor Speaker[7]. As an alternate, playback may be channeled
through a CCTV monitor with amplifier or through DVR’s speaker system
2) If connecting to a DVR with multiple audio inputs or to a soundcard module:
AP-2 has 4 line level RCA Mic Output Jacks [11]
1) Connect RCA cables between the Mic Output Jacks [11] and Audio Inputs of DVR matching zone 1 to
channel 1 of the DVR audio inputs.
2) For audio playback from base station, press in the Play/Mute Switch[1] located on base station’s front
panel. Playback may also be channeled through other audio sources
APPLYING POWER TO THE AP-2
A 12Vdc power supply is included with the above units. First connect the small end with the 90° plug to the above
units Power Jack[10] and connect large end to a standard 120Vac outlet or power strip.
Maximum distance between AP-2, etc. and Louroe microphones is 1,000 ft. (305m)
LOUROE ELECTRONICS 6 9 5 5 VALJEAN AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
®
website: www.louroe.com e-mail: sales@louroe.com
Page 4 of 8
(818)
AP_2_inst_2/15
INSTALLATION AND OPERATING INSTRUCTIONS
INTERCONNECTION DIAGRAM FOR VERIFACT A MICROPHONE
®
AND AP-2 BASE STATION
CBA
N
VERIFACT A MICROPHONE
®
A B C
L
Red(A)
Black(B)
Red(A)
Bare(C)
Black(B)
WIRING REQUIREMENTS
2 Cond Shielded Cable
22 Gauge with a 24 Gauge
Drain wire.
Bare(C)
REAR OF AP-2 BASE STATION
Red(A)
SELECTABLE
AUDIO OUTPUT
Use for audio playback
from recording device
Black(B)
Bare(C)
A
C
A
C
B
1
B
2
Use if recording device
has only one Audio Input
INOUT
12Vdc
LOUROE ELECTRONICS 6 9 5 5 VALJEAN AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
website: www.louroe.com e-mail: sales@louroe.com
Page 5 of 8
(818)
AP_2_inst_2/15
INSTALLATION AND OPERATING INSTRUCTIONS
OPERATION AND TEST
After microphones and power supply are connected, proceed as follows:
1)Turn on power to the unit by rotating the Power-Volume Knob[5] clockwise to “ON” position. The green LED
[4] will illuminate, indicating power to the unit. Rotate Power-Volume Knob[5] further clockwise to increase
the volume of monitored audio.
2)Press Zone Selector Switch[2] marked zone 1. Audio from zone 1 should be present at the Monitor
Speaker[7]. The switch blue light should be ON indicating that zone is activated. If there is no audio, remove
wires connected to Mic Input 3-Pin Terminal Block[6] for zone 1 at the rear of the unit. With a DC voltmeter,
check that 12 Vdc is present at terminals “A” and “C”. If voltage is not present, unit has defective power
supply. If voltage is present, check to assure that wires are connected properly to the right terminals.
Otherwise microphone is defective. Call factory for assistance.
3)Repeat step 2 for the remainder of the zones.
4)When a recorder is connected to the unit, press Play/Mute Switch[1]. The Play/Mute Switch[1] will light. The
audio from the remote microphones are muted. Press DVR playback switch to listen to recorded audio on the
unit’s speaker. The Play/Mute Switch[1] must be depressed or in the “OUT” position to hear live audio again
on the Monitor Speaker[7].
LOUROE ELECTRONICS 6 9 5 5 VALJEAN AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
®
website: www.louroe.com e-mail: sales@louroe.com
Page 6 of 8
(818)
AP_2_inst_2/15
INSTALLATION AND OPERATING INSTRUCTIONS
SPECIFICATIONS (AP-2)
Monitor power output1W @ 8
Audio output impedance
1K?
Audio input impedance10k
Freq. response 100 Hz to 10kHz
Headphone impedance
Current Drain
8 to 600
200mA
Power input12 Vdc, 500mA
Dimensions6 5/8"W x 8 5/8 x 2 1/8"H"L
Weight1lb 5 oz
Shipping Weight
3 lbs
LOUROE ELECTRONICS 6 9 5 5 VALJEAN AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
®
website: www.louroe.com e-mail: sales@louroe.com
Page 7 of 8
(818)
AP_2_inst_2/15
MANUFACTURED
IN THE
IMPORTANT NOTICE
When this equipment is used as part of an
audio monitoring system, the law requires
that the public be given notice of AUDIO
MONITORING ON THE PREMISES. A
deca l notice is in cluded with each
microphone shipped.
Federal Law References:
Federal Regulations, US Code, Title 18.
Crime and Criminal Procedure, Sec 2510.
AUDIO
MONITORING
On
These Premises
®
LOUROE ELECTRONICS warrants that at the time of shipment products manufactured by LOUROE ELECTRONICS to be free of defects in material and workmanship.
Should a defect appear within one year (12 months) from date of shipment, LOUROE ELECTRONICS will, at its sole discretion, repair or replace the defective equipment.
This equipment shall not be accepted for repair or return without prior notification by LOUROE ELECTRONICS .
This warranty does not extend to any Louroe product that has been subjected to improper or incorrect installation, misuse, accident, or in violation of installation
instructions provided by LOUROE ELECTRONICS.
Returned shipments to LOUROE ELECTRONICS shall be at customer’s expense. LOUROE ELECTRONICS will return the equipment prepaid via best way.
LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
®
®
®
®
website: www.louroe.com e-mail: sales@louroe.com
WARRANTY
Page 8 of 8
®
®
®
(818)
AP_2_inst_2/15
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.